21 resultados para Robotic navigation systems


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Computer-aided microscopic surgery of the lateral skull base is a rare intervention in daily practice. It is often a delicate and difficult minimally invasive intervention, since orientation between the petrous bone and the petrous bone apex is often challenging. In the case of aural atresia or tumors the normal anatomical landmarks are often absent, making orientation more difficult. Navigation support, together with imaging techniques such as CT, MR and angiography, enable the surgeon in such cases to perform the operation more accurately and, in some cases, also in a shorter time. However, there are no internationally standardised indications for navigated surgery on the lateral skull base. Miniaturised robotic systems are still in the initial validation phase.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The application of image-guided systems with or without support by surgical robots relies on the accuracy of the navigation process, including patient-to-image registration. The surgeon must carry out the procedure based on the information provided by the navigation system, usually without being able to verify its correctness beyond visual inspection. Misleading surrogate parameters such as the fiducial registration error are often used to describe the success of the registration process, while a lack of methods describing the effects of navigation errors, such as those caused by tracking or calibration, may prevent the application of image guidance in certain accuracy-critical interventions. During minimally invasive mastoidectomy for cochlear implantation, a direct tunnel is drilled from the outside of the mastoid to a target on the cochlea based on registration using landmarks solely on the surface of the skull. Using this methodology, it is impossible to detect if the drill is advancing in the correct direction and that injury of the facial nerve will be avoided. To overcome this problem, a tool localization method based on drilling process information is proposed. The algorithm estimates the pose of a robot-guided surgical tool during a drilling task based on the correlation of the observed axial drilling force and the heterogeneous bone density in the mastoid extracted from 3-D image data. We present here one possible implementation of this method tested on ten tunnels drilled into three human cadaver specimens where an average tool localization accuracy of 0.29 mm was observed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND Stereotactic navigation technology can enhance guidance during surgery and enable the precise reproduction of planned surgical strategies. Currently, specific systems (such as the CAS-One system) are available for instrument guidance in open liver surgery. This study aims to evaluate the implementation of such a system for the targeting of hepatic tumors during robotic liver surgery. MATERIAL AND METHODS Optical tracking references were attached to one of the robotic instruments and to the robotic endoscopic camera. After instrument and video calibration and patient-to-image registration, a virtual model of the tracked instrument and the available three-dimensional images of the liver were displayed directly within the robotic console, superimposed onto the endoscopic video image. An additional superimposed targeting viewer allowed for the visualization of the target tumor, relative to the tip of the instrument, for an assessment of the distance between the tumor and the tool for the realization of safe resection margins. RESULTS Two cirrhotic patients underwent robotic navigated atypical hepatic resections for hepatocellular carcinoma. The augmented endoscopic view allowed for the definition of an accurate resection margin around the tumor. The overlay of reconstructed three-dimensional models was also used during parenchymal transection for the identification of vascular and biliary structures. Operative times were 240 min in the first case and 300 min in the second. There were no intraoperative complications. CONCLUSIONS The da Vinci Surgical System provided an excellent platform for image-guided liver surgery with a stable optic and instrumentation. Robotic image guidance might improve the surgeon's orientation during the operation and increase accuracy in tumor resection. Further developments of this technological combination are needed to deal with organ deformation during surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Keyboards, mice, and touch screens are a potential source of infection or contamination in operating rooms, intensive care units, and autopsy suites. The authors present a low-cost prototype of a system, which allows for touch-free control of a medical image viewer. This touch-free navigation system consists of a computer system (IMac, OS X 10.6 Apple, USA) with a medical image viewer (OsiriX, OsiriX foundation, Switzerland) and a depth camera (Kinect, Microsoft, USA). They implemented software that translates the data delivered by the camera and a voice recognition software into keyboard and mouse commands, which are then passed to OsiriX. In this feasibility study, the authors introduced 10 medical professionals to the system and asked them to re-create 12 images from a CT data set. They evaluated response times and usability of the system compared with standard mouse/keyboard control. Users felt comfortable with the system after approximately 10 minutes. Response time was 120 ms. Users required 1.4 times more time to re-create an image with gesture control. Users with OsiriX experience were significantly faster using the mouse/keyboard and faster than users without prior experience. They rated the system 3.4 out of 5 for ease of use in comparison to the mouse/keyboard. The touch-free, gesture-controlled system performs favorably and removes a potential vector for infection, protecting both patients and staff. Because the camera can be quickly and easily integrated into existing systems, requires no calibration, and is low cost, the barriers to using this technology are low.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A total knee arthroplasty performed with navigation results in more accurate component positioning with fewer outliers. It is not known whether image-based or image-free-systems are preferable and if navigation for only one component leads to equal accuracy in leg alignment than navigation of both components. We evaluated the results of total knee arthroplasties performed with femoral navigation. We studied 90 knees in 88 patients who had conventional total knee arthroplasties, image-based total knee arthroplasties, or total knee arthroplasties with image-free navigation. We compared patients' perioperative times, component alignment accuracy, and short-term outcomes. The total surgical time was longer in the image-based total knee arthroplasty group (109 +/- 7 minutes) compared with the image-free (101 +/- 17 minutes) and conventional total knee arthroplasty groups (87 +/- 20 minutes). The mechanical axis of the leg was within 3 degrees of neutral alignment, although the conventional total knee arthroplasty group showed more (10.6 degrees ) variance than the navigated groups (5.8 degrees and 6.4 degrees , respectively). We found a positive correlation between femoral component malalignment and the total mechanical axis in the conventional group. Our results suggest image-based navigation is not necessary, and image-free femoral navigation may be sufficient for accurate component alignment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work addresses the evolution of an artificial neural network (ANN) to assist in the problem of indoor robotic localization. We investigate the design and building of an autonomous localization system based on information gathered from wireless networks (WN). The article focuses on the evolved ANN, which provides the position of a robot in a space, as in a Cartesian coordinate system, corroborating with the evolutionary robotic research area and showing its practical viability. The proposed system was tested in several experiments, evaluating not only the impact of different evolutionary computation parameters but also the role of the transfer functions on the evolution of the ANN. Results show that slight variations in the parameters lead to significant differences on the evolution process and, therefore, in the accuracy of the robot position.