135 resultados para Right Operator


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reconstruction of the right ventricular outflow tract plays a major role in congenital cardiac surgery. With the advent of the Contegra bovine jugular vein graft and the Shelhigh pulmonic xenograft, hopes were high that the lack of availability of homografts would be overcome. The present study evaluated both grafts and investigated the influence of known risk factors for premature graft failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Right axillary artery (RAA) cannulation is increasingly used in cardiac surgery. Little is known about resulting flow patterns in the aorta. Therefore, flow was visualized and analyzed. A mock circulatory circuit was assembled based on a compliant transparent anatomical silicon aortic model. A RAA cannula was connected to a continuous flow rotary blood pump (RBP), pulsatile heart action was provided by a pneumatic ventricular assist device (PVAD). Peripheral vascular resistance, regional flow and vascular compliance were adjusted to obtain physiological flow and pressure waveforms. Colorants were injected automatically for flow visualization. Five flow distributions with a total flow of 4 l/min were tested (%PVAD:%RBP): 100:0, 75:25, 50:50, 25:75, 0:100. Colorant distribution was assessed using quantitative 2D image processing. Continuous flow from the RAA divided in a retrograde and an antegrade portion. Retro- to antegrade flow ratio increased with increasing RAA-flow. At full RBP support flow was stagnant in the ascending aorta. There were distinct flow patterns between the right- and left-sided supra-aortic branches. At full RBP support retrograde flow was demonstrated in the right carotid and right vertebral arteries. Further studies are needed to confirm and evaluate the described flow patterns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Right ventricular (RV) systolic function is prognostically important, but its assessment by echocardiography remains challenging, in part because of the multitude of available measurement methods. The purpose of this prospective study was to rank these methods against the reference of RV ejection fraction (EF) as obtained in a broad clinical population by magnetic resonance imaging (MRI).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Improvements of language production in aphasic patients have been reported following repeated 1-Hz transcranial magnetic stimulation over the nondamaged right hemisphere. Most studies examined aphasic patients in the chronic phase. The effect of transcranial magnetic stimulation application in acute or subacute patients has not been systematically studied. We aimed to evaluate whether continuous theta burst stimulation, an inhibitory protocol with a shorter application time than the common 1-Hz protocol, is able to improve naming performance in aphasic patients in different poststroke phases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 7 year old male mongrel dog was presented with a 3 weeks history of gait disturbance in the pelvic limbs more pronounced on the left side associated with pain in the lumbar spine. At presentation neurologic deficits consisted of mild bilateral proprioceptive deficits and nerve root signature in the left pelvic limb. A large intervertebral disc herniation L3-L4 located in a right ventrolateral area of the spinal canal was diagnosed by magnetic resonance imaging. The herniated disc was removed through right hemilaminectomy and fenestration. The dog recovered quickly and returned to the owners 4 days after surgery with a slight lameness in the left pelvic limb. On the follow-up examination 2 months later the dog showed normal gait and normal neurological examination. Nerve root signature is not always indicative for the side of the lesion in case of lateralized intervertebral disc herniation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Dogs experimentally inoculated with Angiostrongylus vasorum develop severe pulmonary parenchymal lesions and arterial thrombosis at the time of patency. HYPOTHESIS: A. vasorum-induced thrombosis results in arterial hypoxemia, pulmonary hypertension (PH), and altered cardiac morphology and function. ANIMALS: Six healthy Beagles experimentally inoculated with A. vasorum. METHODS: Thoracic radiographs and arterial blood gas analyses were performed 8 and 13 weeks postinoculation (wpi) and 9 weeks posttherapy (wpt). Echocardiography was done before and 2, 5, 8, 13 wpi and 9 wpt. Invasive pulmonary artery pressure (PAP) measurements were obtained 8 wpi. Two untreated dogs were necropsied 13 wpi and 4 treated dogs 9 wpt. RESULTS: All dogs had patent infections at 7 wpi and clinical respiratory signs at 8 wpi. Moderate hypoxemia (median PaO2 of 73 and 74 mmHg) present at 8 and 13 wpi had resolved by 9 wpt. Echocardiographically, no evidence of PH and no abnormalities in cardiac size and function were discernible at any time point. PAP invasively measured at 8 wpi was not different from that of control dogs. Severe radiographic pulmonary parenchymal and suspected thrombotic lesions at 13 wpi were corroborated by necropsy. Most histopathologic changes had resolved at 9 wpt, but focal inflammatory, thrombotic, and fibrotic changes still were present in all dogs. CONCLUSION: In experimentally infected Beagles, pulmonary and vascular changes induced by A. vasorum are reflected by marked radiographic changes and arterial hypoxemia. These did not result in PH and echocardiographic changes in cardiac size and function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to test the hypothesis that ear oximetry immediately after the release of a sustained Valsalva maneuver accurately detects patent foramen ovale (PFO). One hundred sixty-five scuba divers underwent transesophageal echocardiography (TEE; reference method) for PFO assessment. Ear oximetry of the right earlobe was performed in a different room within a time frame of 2 hours before or after TEE. The subject and the oximetry operator were unaware of the results of TEE. Oxygen saturation (SO(2)) measurements were obtained at baseline and during the release phase of 4 Valsalva maneuvers within 10 minutes, and the average SO(2) change (SO(2) at baseline minus SO(2) at Valsalva release) was determined as the primary study end point. One hundred seventeen divers had no PFO, and 48 (29%) had PFO by TEE (mean age 39 ± 8 years). The average SO(2) change was 0.79 ± 1.13% (i.e., a slight absolute SO(2) decrease in response to the Valsalva maneuver) in the group without PFO and 1.67 ± 1.19% in the PFO group (p <0.0001). Using receiver-operating characteristic curve analysis, a PFO as defined by TEE could be detected at a threshold of a Valsalva-induced decrease in SO(2) of ≥0.825 percentage points in comparison to baseline (sensitivity 0.756, specificity 0.706, area under the receiver-operating characteristic curve 0.763, p <0.0001, negative predictive value 0.882). In conclusion, the entirely noninvasive method of ear oximetry in response to repetitive Valsalva maneuvers is accurate and useful as a screening method for the detection of a PFO, as shown in this study of divers.