82 resultados para Return of results


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Recent studies have shown that a low clinical pretest probability may be adequate for excluding heparin-induced thrombocytopenia. However, for patients with intermediate or high pretest probability, laboratory testing is essential for confirming or refuting the diagnosis. Rapid assessment of anti-PF4/heparin-antibodies may assist clinical decision-making. OBJECTIVES: To evaluate the performance of rapid ID-H/PF4-PaGIA. In particular, we verified reproducibility of results between plasma and serum specimens, between fresh and frozen samples, and between different ID-H/PF4-polymer lots (polystyrene beads coated with heparin/PF4-complexes). PATIENTS/METHODS: The samples studied were 1376 plasma and 914 corresponding serum samples from patients investigated for suspected heparin-induced thrombocytopenia between January 2000 and October 2008. Anti-PF4/heparin-antibodies were assessed by ID-H/PF4-PaGIA, commercially available ELISAs and heparin-induced platelet aggregation test. RESULTS: Among 914 paired plasma/serum samples we noted discordant results (negative vs. low-titre positive) in nine instances (1%; 95%CI, 0.4-1.6%). Overall, agreement between titres assessed in plasma vs. serum was highly significant (Spearman correlation coefficient, 0.975; P < 0.0001). Forty-seven samples tested both fresh and after freezing/thawing showed a good agreement, with one discordant positive/negative result (Spearman correlation coefficient, 0.970; P < 0.0001). Among 1376 plasma samples we noted a strikingly variable incidence of false negative results (none - 82%; 95%CI, 66-98%), depending on the employed ID-H/PF4-polymer lot. Faulty lots can be recognized by titrating commercial positive controls and stored samples of HIT-patients. CONCLUSION: Laboratories performing the assay should implement stringent internal quality controls in order to recognize potentially faulty ID-H/PF4-polymer lots, thus avoiding false negative results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To determine whether standard or increased doses of atropine improve the return of spontaneous circulation (ROSC) rate in a canine model of pulseless electrical activity (PEA). METHODS A prospective, controlled, blinded laboratory investigation was performed using an asphyxial canine cardiac arrest model. After the production of asphyxial PEA, 75 dogs remained in untreated PEA for 10 minutes and then were randomized to receive placebo (group 1) or one of four doses of atropine (group 2, 0.04 mg/kg; group 3, 0.1 mg/kg; group 4, 0.2 mg/kg; group 5, 0.4 mg/kg). All the animals received mechanical external CPR and epinephrine (0.02 mg/kg every 3 minutes) throughout resuscitation. RESULTS The ROSC rates were not significantly different between the groups (group 1, 73%; group 2, 67%; group 3, 40%; group 4, 47%; group 5, 27%; p = 0.06). The heart rates and hemodynamics during resuscitation were not significantly different between the groups. CONCLUSION In this canine model of asphyxial PEA cardiac arrest, standard-dose atropine did not improve ROSC rates, compared with placebo. Increasing doses of atropine tended to decrease ROSC rates, compared with placebo and standard-dose atropine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Intravenous anaesthetic drugs are the primary means for producing general anaesthesia in equine practice. The ideal drug for intravenous anaesthesia has high reliability and pharmacokinetic properties indicating short elimination and lack of accumulation when administered for prolonged periods. Induction of general anaesthesia with racemic ketamine preceded by profound sedation has already an established place in the equine field anaesthesia. Due to potential advantages over racemic ketamine, S-ketamine has been employed in horses to induce general anaesthesia, but its optimal dose remains under investigation. The objective of this study was to evaluate whether 2.5 mg/kg S-ketamine could be used as a single intravenous bolus to provide short-term surgical anaesthesia in colts undergoing surgical castration, and to report its pharmacokinetic profile. RESULTS After premedication with romifidine and L-methadone, the combination of S-ketamine and diazepam allowed reaching surgical anaesthesia in the 28 colts. Induction of anaesthesia as well as recovery were good to excellent in the majority (n = 22 and 24, respectively) of the colts. Seven horses required additional administration of S-ketamine to prolong the duration of surgical anaesthesia. Redosing did not compromise recovery quality. Plasma concentration of S-ketamine decreased rapidly after administration, following a two-compartmental model, leading to the hypothesis of a consistent unchanged elimination of the parent compound into the urine beside its conversion to S-norketamine. The observed plasma concentrations of S-ketamine at the time of first movement were various and did not support the definition of a clear cut-off value to predict the termination of the drug effect. CONCLUSIONS The administration of 2.5 mg/kg IV S-ketamine after adequate premedication provided good quality of induction and recovery and a duration of action similar to what has been reported for racemic ketamine at the dose of 2.2 mg/kg. Until further investigations will be provided, close monitoring to adapt drug delivery is mandatory, particularly once the first 10 minutes after injection are elapsed. Taking into account rapid elimination of S-ketamine, significant inter-individual variability and rapid loss of effect over a narrow range of concentrations a sudden return of consciousness has to be foreseen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Evidence suggests that EMS-physician-guided cardiopulmonary resuscitation (CPR) in out-of-hospital cardiac arrest (OOHCA) may be associated with improved outcomes, yet randomized controlled trials are not available. The goal of this meta-analysis was to determine the association between EMS-physician- versus paramedic-guided CPR and survival after OOHCA. METHODS AND RESULTS Studies that compared EMS-physician- versus paramedic-guided CPR in OOHCA published until June 2014 were systematically searched in MEDLINE, EMBASE and Cochrane databases. All studies were required to contain survival data. Data on study characteristics, methods, and as well as survival outcomes were extracted. A random-effects model was used for the meta-analysis due to a high degree of heterogeneity among the studies (I (2)  = 44 %). Return of spontaneous circulation [ROSC], survival to hospital admission, and survival to hospital discharge were the outcome measures. Out of 3,385 potentially eligible studies, 14 met the inclusion criteria. In the pooled analysis (n = 126,829), EMS-physician-guided CPR was associated with significantly improved outcomes compared to paramedic-guided CPR: ROSC 36.2 % (95 % confidence interval [CI] 31.0 - 41.7 %) vs. 23.4 % (95 % CI 18.5 - 29.2 %) (pooled odds ratio [OR] 1.89, 95 % CI 1.36 - 2.63, p < 0.001); survival to hospital admission 30.1 % (95 % CI 24.2 - 36.7 %) vs. 19.2 % (95 % CI 12.7 - 28.1 %) (pooled OR 1.78, 95 % CI 0.97 - 3.28, p = 0.06); and survival to discharge 15.1 % (95 % CI 14.6 - 15.7 %) vs. 8.4 % (95 % CI 8.2 - 8.5 %) (pooled OR 2.03, 95 % CI 1.48 - 2.79, p < 0.001). CONCLUSIONS This systematic review suggests that EMS-physician-guided CPR in out-of-hospital cardiac arrest is associated with improved survival outcomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Multiple True-False-Items (MTF-Items) might offer some advantages compared to one-best-answer-questions (TypeA) as they allow more than one correct answer and may better represent clinical decisions. However, in medical education assessment MTF-Items are seldom used. Summary of Work: With this literature review existing findings on MTF-items and on TypeA were compared along the Ottawa Criteria for Good Assessment, i.e. (1) reproducibility, (2) feasibility, (3) validity, (4) acceptance, (5) educational effect, (6) catalytic effects, and (7) equivalence. We conducted a literature research on ERIC and Google Scholar including papers from the years 1935 to 2014. We used the search terms “multiple true-false”, “true-false”, “true/false”, and “Kprim” combined with “exam”, “test”, and “assessment”. Summary of Results: We included 29 out of 33 studies. Four of them were carried out in the medical field Compared to TypeA, MTF-Items are associated with (1) higher reproducibility (2) lower feasibility (3) similar validity (4) higher acceptance (5) higher educational effect (6) no studies on catalytic effects or (7) equivalence. Discussion and Conclusions: While studies show overall good characteristics of MTF items according to the Ottawa criteria, this type of question seems to be rather seldom used. One reason might be the reported lower feasibility. Overall the literature base is still weak. Furthermore, only 14 % of literature is from the medical domain. Further studies to better understand the characteristics of MTF-Items in the medical domain are warranted. Take-home messages: Overall the literature base is weak and therefore further studies are needed. Existing studies show that: MTF-Items show higher reliability, acceptance and educational effect; MTF-Items are more difficult to produce

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Current guidelines limit the use of high oxygen tension after return of spontaneous circulation after cardiac arrest, focusing on neurological outcome and mortality. Little is known about the impact of hyperoxia on the ischemic heart. Oxygen is frequently administered and is generally expected to be beneficial. This study seeks to assess the effects of hyperoxia on myocardia oxygenation in the presence of severe coronary artery stenosis in swine. METHODS AND RESULTS In 22 healthy pigs, we surgically attached a magnetic resonance compatible flow probe to the left anterior descending coronary artery (LAD). In 11 pigs, a hydraulic occluder was inflated distal to the flow probe. After increasing PaO2 to >300 mm Hg, LAD flow decreased in all animals. In 8 stenosed animals with a mean fractional flow reserve of 0.64±0.02, hyperoxia resulted in a significant decrease of myocardial signal intensity in oxygenation-sensitive cardiovascular magnetic resonance images of the midapical segments of the LAD territory. This was not seen in remote myocardium or in the other 8 healthy animals. The decreased signal intensity was accompanied by a decrease in circumferential strain in the same segments. Furthermore, ejection fraction, cardiac output, and oxygen extraction ratio declined in these animals. Changing PaCO2 levels did not have a significant effect on any of the parameters; however, hypercapnia seemed to nonsignificantly attenuate the hyperoxia-induced changes. CONCLUSIONS Ventilation-induced hyperoxia may decrease myocardial oxygenation and lead to ischemia in myocardium subject to severe coronary artery stenosis.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE: To evaluate the use of covered stent-grafts in the endovascular treatment (ET) of popliteal artery aneurysms (PAAs). MATERIALS AND METHODS: A retrospective analysis was conducted over a period of 52 months in 18 consecutive patients (17 men; mean age +/- SD, 70 years +/- 11) undergoing ET of PAAs with the Viabahn endograft in a single center. Patient symptoms, aneurysm characteristics, technical outcomes, complications, and follow-up were assessed. RESULTS: Aneurysm diameters ranged from 12 to 51 mm with a mean of 30 mm (+/-11). Thirteen aneurysms (72.2%) were partially thrombosed and 12 patients (66.6%) had symptoms of lower limb ischemia at presentation (11 chronic and one acute). The technical success rate was 94%. Intraprocedural emboli and endoleak occurred in one and two patients, respectively. Fourteen patients were available for follow-up after successful treatment, with a mean follow-up time of 15 months (range, 7-37 months). All stent-grafts were patent after 1 month, with no mortality or limb loss. The primary patency rate with complete exclusion of the aneurysm at 6 months was 86%. Pre- and postprocedural noninvasive arterial studies were available in 10 patients, demonstrating improvement of the ankle-brachial index from 0.96 +/- 0.41 to 1.17 +/- 0.18, respectively (P = .06). CONCLUSIONS: Endovascular stent-graft repair of PAAs is a feasible treatment option. However, further follow-up studies regarding the durability of results are required.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The classic Goldmann applanation tonometer (GAT) has been further developed by Haag-Streit International. The applanation principle has been retained, while the internal force transmission and the pressure gauging have been optimised, the display of results digitised. The authors compared the GAT standard with the new GAT digital.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

STEPanizer is an easy-to-use computer-based software tool for the stereological assessment of digitally captured images from all kinds of microscopical (LM, TEM, LSM) and macroscopical (radiology, tomography) imaging modalities. The program design focuses on providing the user a defined workflow adapted to most basic stereological tasks. The software is compact, that is user friendly without being bulky. STEPanizer comprises the creation of test systems, the appropriate display of digital images with superimposed test systems, a scaling facility, a counting module and an export function for the transfer of results to spreadsheet programs. Here we describe the major workflow of the tool illustrating the application on two examples from transmission electron microscopy and light microscopy, respectively.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Since the first description of spinal and epidural anaesthesia, postdural puncture headache (PDPH) is a well known complication. Its prophylaxis and treatment has been studied and discussed for more than 100 years, but the evidence is still limited. Due to relatively low prevalence of PDPH, prospective RCTs are often missing, and the frequently self-limiting character of PDPH impedes an adequate interpretation of results from studies without a control group. Taking side effects and complications into account, a prophylactic treatment of PDPH cannot be recommended. In case of PDPH, non-opioid analgesics are the first choice treatment. The epidural blood patch remains the mainstay of severe PDPH therapy. Noninvasive therapies like theophylline, sumatriptan and ACTH can be an alternative. However, an evidence-based recommendation is lacking. The development of standard operating procedures for accidental dural punctures and PDPH is recommended.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objectives Appropriate reporting is central to the application of findings from research to clinical practice. The Strengthening the Reporting of Observational Studies in Epidemiology (STROBE) recommendations consist of a checklist of 22 items that provide guidance on the reporting of cohort, case-control and cross-sectional studies, in order to facilitate critical appraisal and interpretation of results. STROBE was published in October 2007 in several journals including The Lancet, BMJ, Annals of Internal Medicine and PLoS Medicine. Within the framework of the revision of the STROBE recommendations, the authors examined the context and circumstances in which the STROBE statement was used in the past. Design The authors searched the Web of Science database in August 2010 for articles which cited STROBE and examined a random sample of 100 articles using a standardised, piloted data extraction form. The use of STROBE in observational studies and systematic reviews (including meta-analyses) was classified as appropriate or inappropriate. The use of STROBE to guide the reporting of observational studies was considered appropriate. Inappropriate uses included the use of STROBE as a tool to assess the methodological quality of studies or as a guideline on how to design and conduct studies. Results The authors identified 640 articles that cited STROBE. In the random sample of 100 articles, about half were observational studies (32%) or systematic reviews (19%). Comments, editorials and letters accounted for 15%, methodological articles for 8%, and recommendations and narrative reviews for 26% of articles. Of the 32 observational studies, 26 (81%) made appropriate use of STROBE, and three uses (10%) were considered inappropriate. Among 19 systematic reviews, 10 (53%) used STROBE inappropriately as a tool to assess study quality. Conclusions The STROBE reporting recommendations are frequently used inappropriately in systematic reviews and meta-analyses as an instrument to assess the methodological quality of observational studies.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Patients' reports of safety-related events and perceptions of safety can be a valuable source for hospitals. Patients of eight acute care hospitals in Switzerland were surveyed for safety-related events and concerns for safety. In workshops with hospitals areas for improvement were analyzed and priorities for change identified. To evaluate the benefit of the approach, semi-structured interviews were conducted with hospital risk managers. 3,983 patients returned the survey (55% response rate). 21.4% reported at least one definite safety event, and the mean number of 'definite' incidents per patient was 0.31 (95% CI=0.29 to 0.34). 3.2% were very concerned and 14.7% were somewhat concerned about medical errors and safety. Having experienced a safety-related event, younger age, length of stay, poor health and a poor education increased the probability of reporting concerns. With some exceptions, results confirmed the hospitals' a priori expectations regarding the strengths and weaknesses of their institutions. Risk managers emphasized the usability of results for their work and the special value of referring to the patient's perspective at their home institutions. A considerable fraction of patients subjectively experiences safety-related events and is concerned about safety. Patient-generated data introduced a new quality into the discussion of safety issues within hospitals, and some expected that patients' experiences and concerns could affect patient volumes. Though the study is limited by the short time horizon and the lack of follow-up, the results suggest that the described approach is feasible and can serve as a supplemental tool for risk identification and management.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The objective of this study was to develop a criteria catalogue serving as a guideline for authors to improve quality of reporting experiments in basic research in homeopathy. A Delphi Process was initiated including three rounds of adjusting and phrasing plus two consensus conferences. European researchers who published experimental work within the last 5 years were involved. A checklist for authors provide a catalogue with 23 criteria. The “Introduction” should focus on underlying hypotheses, the homeopathic principle investigated and state if experiments are exploratory or confirmatory. “Materials and methods” should comprise information on object of investigation, experimental setup, parameters, intervention and statistical methods. A more detailed description on the homeopathic substances, for example, manufacture, dilution method, starting point of dilution is required. A further result of the Delphi process is to raise scientists' awareness of reporting blinding, allocation, replication, quality control and system performance controls. The part “Results” should provide the exact number of treated units per setting which were included in each analysis and state missing samples and drop outs. Results presented in tables and figures are as important as appropriate measures of effect size, uncertainty and probability. “Discussion” in a report should depict more than a general interpretation of results in the context of current evidence but also limitations and an appraisal of aptitude for the chosen experimental model. Authors of homeopathic basic research publications are encouraged to apply our checklist when preparing their manuscripts. Feedback is encouraged on applicability, strength and limitations of the list to enable future revisions.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We present results from the international field campaign DAURE (Detn. of the sources of atm. Aerosols in Urban and Rural Environments in the Western Mediterranean), with the objective of apportioning the sources of fine carbonaceous aerosols. Submicron fine particulate matter (PM1) samples were collected during Feb.-March 2009 and July 2009 at an urban background site in Barcelona (BCN) and at a forested regional background site in Montseny (MSY). We present radiocarbon (14C) anal. for elemental and org. carbon (EC and OC) and source apportionment for these data. We combine the results with those from component anal. of aerosol mass spectrometer (AMS) measurements, and compare to levoglucosan-based ests. of biomass burning OC, source apportionment of filter data with inorg. compn. + EC + OC, submicron bulk potassium (K) concns., and gaseous acetonitrile concns. At BCN, 87 % and 91 % of the EC on av., in winter and summer, resp., had a fossil origin, whereas at MSY these fractions were 66 % and 79 %. The contribution of fossil sources to org. carbon (OC) at BCN was 40 % and 48 %, in winter and summer, resp., and 31 % and 25 % at MSY. The combination of results obtained using the 14C technique, AMS data, and the correlations between fossil OC and fossil EC imply that the fossil OC at Barcelona is ∼47 % primary whereas at MSY the fossil OC is mainly secondary (∼85 %). Day-to-day variation in total carbonaceous aerosol loading and the relative contributions of different sources predominantly depended on the meteorol. transport conditions. The estd. biogenic secondary OC at MSY only increased by ∼40 % compared to the order-of-magnitude increase obsd. for biogenic volatile org. compds. (VOCs) between winter and summer, which highlights the uncertainties in the estn. of that component. Biomass burning contributions estd. using the 14C technique ranged from similar to slightly higher than when estd. using other techniques, and the different estns. were highly or moderately correlated. Differences can be explained by the contribution of secondary org. matter (not included in the primary biomass burning source ests.), and/or by an over-estn. of the biomass burning OC contribution by the 14C technique if the estd. biomass burning EC/OC ratio used for the calcns. is too high for this region. Acetonitrile concns. correlate well with the biomass burning EC detd. by 14C. K is a noisy tracer for biomass burning. [on SciFinder(R)]

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The effectiveness of specialised nursing in breast cancer has received limited attention. This systematic literature review aims at (i) presenting and discussing role models of specialised nursing in the area of breast cancer and (ii) suggesting avenues for future research in this field. The ten studies included in the review differ with respect to the roles of specialised nurses as well as the measured outcome variables; thus, the comparability and generalisability of results are limited. Nevertheless, the review indicates that specialised nursing in breast cancer may contribute to improved physical and psycho-social well-being. In view of the limited comparability, the authors call for (i) a more uniform definition of models of specialised nursing in breast cancer care, as well as (ii) rigorous confirmatory studies to evaluate their effectiveness. These two aspects are pivotal in providing a reliable basis for future health care strategies.