24 resultados para Reorientation
Resumo:
Background Acetabular anatomy on AP pelvic radiographsdepends on pelvic orientation during radiograph acquisition. However, not all parameters may change to a clinically relevant degree with differences in pelvic orientation. This issue may influence the diagnosis of acetabular pathologies and planning of corrective acetabular surgery (reorientation or rim trimming). However, to this point, it has not been well characterized. Questions/purposes We asked (1) which radiographic parameters change in a clinical setting when normalized to neutral pelvic orientation; (2) which parameters do not change in an experimental setting when the pelvis is experimentally rotated/tilted; and (3) which of these changes are ‘‘ultimately’’ relevant based on a prespecified definition of relevance. Methods In a clinical setup, 11 hip parameters were evaluated in 101 patients (126 hips) by two observers and the interobserver difference was calculated. All parameters were normalized to an anatomically defined neutral pelvic orientation with the help of a lateral pelvic radiograph and specific software. Differences between nonnormalized and normalized values were calculated (effect of normalization). In an experimental setup involving 20 cadaver pelves (40 hips), the maximum range for each parameter was computed with the pelvis rotated (range, −12° to 12°) and tilted (range, −24° to 24°). ‘‘Ultimately’’ relevant changes existed if the effect of normalization exceeded the interobserver difference (eg, 37% versus 6% for prevalence of a positive crossover sign) and/or the maximum experimental range exceeded 1 SD of interobserver difference (eg, 27% versus 6% for anterior acetabular coverage). Results In the clinical setup, all parameters except the ACM angle and craniocaudal acetabular coverage changed when being normalized, eg, effect of normalization for lateral center-edge angle, acetabular index, and sharp angle ranged from −5° to 4° (p values < 0.029). In the experimental setup, five parameters showed no major changes, whereas six parameters did change (all p values < 0.001). Ultimately relevant changes were found for anteroposterior acetabular coverage, retroversion index, and prevalence of a positive crossover or posterior wall sign. Conclusions Lateral center-edge angle, ACM angle, Sharp angle, acetabular and extrusion index, and craniocaudal acetabular coverage showed no relevant changes with varying pelvic orientation and can therefore be acquired independent from individual pelvic tilt and rotation in clinical practice. In contrast, anteroposterior acetabular coverage, crossover and posterior wall sign, and retroversion index call for specific efforts that address individual pelvic orientation such as computer-assisted evaluation of radiographs. Level of Evidence Level III, diagnostic study. See the Guidelines for Authors for a complete description of levels of evidence.
Resumo:
The momentary, global functional state of the brain is reflected by its electric field configuration. Cluster analytical approaches consistently extracted four head-surface brain electric field configurations that optimally explain the variance of their changes across time in spontaneous EEG recordings. These four configurations are referred to as EEG microstate classes A, B, C, and D and have been associated with verbal/phonological, visual, attention reorientation, and subjective interoceptive-autonomic processing, respectively. The present study tested these associations via an intra-individual and inter-individual analysis approach. The intra-individual approach tested the effect of task-induced increased modality-specific processing on EEG microstate parameters. The inter-individual approach tested the effect of personal modality-specific parameters on EEG microstate parameters. We obtained multichannel EEG from 61 healthy, right-handed, male students during four eyes-closed conditions: object-visualization, spatial-visualization, verbalization (6 runs each), and resting (7 runs). After each run, we assessed participants' degrees of object-visual, spatial-visual, and verbal thinking using subjective reports. Before and after the recording, we assessed modality-specific cognitive abilities and styles using nine cognitive tests and two questionnaires. The EEG of all participants, conditions, and runs was clustered into four classes of EEG microstates (A, B, C, and D). RMANOVAs, ANOVAs and post-hoc paired t-tests compared microstate parameters between conditions. TANOVAs compared microstate class topographies between conditions. Differences were localized using eLORETA. Pearson correlations assessed interrelationships between personal modality-specific parameters and EEG microstate parameters during no-task resting. As hypothesized, verbal as opposed to visual conditions consistently affected the duration, occurrence, and coverage of microstate classes A and B. Contrary to associations suggested by previous reports, parameters were increased for class A during visualization, and class B during verbalization. In line with previous reports, microstate D parameters were increased during no-task resting compared to the three internal, goal-directed tasks. Topographic differences between conditions concerned particular sub-regions of components of the metabolic default mode network. Modality-specific personal parameters did not consistently correlate with microstate parameters except verbal cognitive style which correlated negatively with microstate class A duration and positively with class C occurrence. This is the first study that aimed to induce EEG microstate class parameter changes based on their hypothesized functional significance. Beyond, the associations of microstate classes A and B with visual and verbal processing, respectively and microstate class D with interoceptive-autonomic processing, our results suggest that a finely-tuned interplay between all four EEG microstate classes is necessary for the continuous formation of visual and verbal thoughts, as well as interoceptive-autonomic processing. Our results point to the possibility that the EEG microstate classes may represent the head-surface measured activity of intra-cortical sources primarily exhibiting inhibitory functions. However, additional studies are needed to verify and elaborate on this hypothesis.
Resumo:
Pelvic osteotomies improve containment of the femoral head in cases of developmental dysplasia of the hip or in femoroacetabular impingement due to acetabular retroversion. In the evolution of osteotomies, the Ganz Periacetabular Osteotomy (PAO) is among the complex reorientation osteotomies and allows for complete mobilization of the acetabulum without compromising the integrity of the pelvic ring. For the complex reorientation osteotomies, preoperative planning of the required acetabular correction is an important step, due to the need to comprehend the three-dimensional (3D) relationship between acetabulum and femur. Traditionally, planning was performed using conventional radiographs in different projections, reducing the 3D problem to a two-dimensional one. Known disturbance variables, mainly tilt and rotation of the pelvis make assessment by these means approximate at the most. The advent of modern enhanced computation skills and new imaging techniques gave room for more sophisticated means of preoperative planning. Apart from analysis of acetabular geometry on conventional x-rays by sophisticated software applications, more accurate assessment of coverage and congruency and thus amount of correction necessary can be performed on multiplanar CT images. With further evolution of computer-assisted orthopaedic surgery, especially the ability to generate 3D models from the CT data, examiners were enabled to simulate the in vivo situation in a virtual in vitro setting. Based on this ability, different techniques have been described. They basically all employ virtual definition of an acetabular fragment. Subsequently reorientation can be simulated using either 3D calculation of standard parameters of femoroacetabular morphology, or joint contact pressures, or a combination of both. Other techniques employ patient specific implants, templates or cutting guides to achieve the goal of safe periacetabular osteotomies. This chapter will give an overview of the available techniques for planning of periacetabular osteotomy.
Resumo:
In this chapter a low-cost surgical navigation solution for periacetabular osteotomy (PAO) surgery is described. Two commercial inertial measurement units (IMU, Xsens Technologies, The Netherlands), are attached to a patient’s pelvis and to the acetabular fragment, respectively. Registration of the patient with a pre-operatively acquired computer model is done by recording the orientation of the patient’s anterior pelvic plane (APP) using one IMU. A custom-designed device is used to record the orientation of the APP in the reference coordinate system of the IMU. After registration, the two sensors are mounted to the patient’s pelvis and acetabular fragment, respectively. Once the initial position is recorded, the orientation is measured and displayed on a computer screen. A patient-specific computer model generated from a pre-operatively acquired computed tomography (CT) scan is used to visualize the updated orientation of the acetabular fragment. Experiments with plastic bones (7 hip joints) performed in an operating room comparing a previously developed optical navigation system with our inertial-based navigation system showed no statistical difference on the measurement of acetabular component reorientation (anteversion and inclination). In six out of seven hip joints the mean absolute difference was below five degrees for both anteversion and inclination.
Resumo:
BACKGROUND Residual acetabular dysplasia is seen in combination with femoral pathomorphologies including an aspherical femoral head and valgus neck-shaft angle with high antetorsion. It is unclear how these femoral pathomorphologies affect range of motion (ROM) and impingement zones after periacetabular osteotomy. QUESTIONS/PURPOSES (1) Does periacetabular osteotomy (PAO) restore the typically excessive ROM in dysplastic hips compared with normal hips; (2) how do impingement locations differ in dysplastic hips before and after PAO compared with normal hips; (3) does a concomitant cam-type morphology adversely affect internal rotation; and (4) does a concomitant varus-derotation intertrochanteric osteotomy (IO) affect external rotation? METHODS Between January 1999 and March 2002, we performed 200 PAOs for dysplasia; of those, 27 hips (14%) met prespecified study inclusion criteria, including availability of a pre- and postoperative CT scan that included the hip and the distal femur. In general, we obtained those scans to evaluate the pre- and postoperative acetabular and femoral morphology, the degree of acetabular reorientation, and healing of the osteotomies. Three-dimensional surface models based on CT scans of 27 hips before and after PAO and 19 normal hips were created. Normal hips were obtained from a population of CT-based computer-assisted THAs using the contralateral hip after exclusion of symptomatic hips or hips with abnormal radiographic anatomy. Using validated and computerized methods, we then determined ROM (flexion/extension, internal- [IR]/external rotation [ER], adduction/abduction) and two motion patterns including the anterior (IR in flexion) and posterior (ER in extension) impingement tests. The computed impingement locations were assigned to anatomical locations of the pelvis and the femur. ROM was calculated separately for hips with (n = 13) and without (n = 14) a cam-type morphology and PAOs with (n = 9) and without (n = 18) a concomitant IO. A post hoc power analysis based on the primary research question with an alpha of 0.05 and a beta error of 0.20 revealed a minimal detectable difference of 4.6° of flexion. RESULTS After PAO, flexion, IR, and adduction/abduction did not differ from the nondysplastic control hips with the numbers available (p ranging from 0.061 to 0.867). Extension was decreased (19° ± 15°; range, -18° to 30° versus 28° ± 3°; range, 19°-30°; p = 0.017) and ER in 0° flexion was increased (25° ± 18°; range, -10° to 41° versus 38° ± 7°; range, 17°-41°; p = 0.002). Dysplastic hips had a higher prevalence of extraarticular impingement at the anteroinferior iliac spine compared with normal hips (48% [13 of 27 hips] versus 5% [one of 19 hips], p = 0.002). A PAO increased the prevalence of impingement for the femoral head from 30% (eight of 27 hips) preoperatively to 59% (16 of 27 hips) postoperatively (p = 0.027). IR in flexion was decreased in hips with a cam-type deformity compared with those with a spherical femoral head (p values from 0.002 to 0.047 for 95°-120° of flexion). A concomitant IO led to a normalization of ER in extension (eg, 37° ± 7° [range, 21°-41°] of ER in 0° of flexion in hips with concomitant IO compared with 38° ± 7° [range, 17°-41°] in nondysplastic control hips; p = 0.777). CONCLUSIONS Using computer simulation of hip ROM, we could show that the PAO has the potential to restore the typically excessive ROM in dysplastic hips. However, a PAO can increase the prevalence of secondary intraarticular impingement of the aspherical femoral head and extraarticular impingement of the anteroinferior iliac spines in flexion and internal rotation. A cam-type morphology can result in anterior impingement with restriction of IR. Additionally, a valgus hip with high antetorsion can result in posterior impingement with decreased ER in extension, which can be normalized with a varus derotation IO of the femur. However, indication of an additional IO needs to be weighed against its inherent morbidity and possible complications. The results are based on a limited number of hips with a pre- and postoperative CT scan after PAO. Future prospective studies are needed to verify the current results based on computer simulation and to test their clinical importance.
Resumo:
Severe pincer impingement (acetabular protrusio) is an established cause of hip pain and osteoarthritis. The proposed underlying pathomechanism is a dynamic pathological contact of the prominent acetabular rim with the femoral head-neck junction. However, this cannot explain the classically described medial osteoarthritis in these hips. We therefore asked: (1) Does an overload exist in the medial aspect of the protrusio joint? and (2) What is the influence of three contemporary joint-preserving procedures on load distribution in protrusio hips? In vivo force and motion data for walking and standing to sitting were applied to six 3D finite element models (normal, dysplasia, protrusio, acetabular rim trimming, acetabular reorientation, and combined reorientation/rim trimming). Compared with dysplasia, the protrusio joint resulted in opposite patterns of von Mises stress and contact pressure during walking. In protrusio hips, we found an overload at the medial margin of the lunate surface (54% higher than normal). Isolated rim trimming further increased the medial overload (up to 28% higher than protrusio), whereas acetabular reorientation with/without rim trimming reduced stresses by up to 25%. Our results can be used as an adjunct for surgical decision making in the treatment of acetabular protrusio.
Resumo:
BACKGROUND As access to antiretroviral therapy (ART) expands, increasing numbers of older patients will start treatment and need specialised long-term care. However, the effect of age in ART programmes in resource-constrained settings is poorly understood. The HIV epidemic is ageing rapidly and South Africa has one of the highest HIV population prevalences worldwide. We explored the effect of age on mortality of patients on ART in South Africa and whether this effect is mediated by baseline immunological status. METHODS In this retrospective cohort analysis, we studied HIV-positive patients aged 16-80 years who started ART for the first time in six large South African cohorts of the International Epidemiologic Databases to Evaluate AIDS-Southern Africa collaboration, in KwaZulu-Natal, Gauteng, and Western Cape (two primary care clinics, three hospitals, and a large rural cohort). The primary outcome was mortality. We ascertained patients' vital status through linkage to the National Population Register. We used inverse probability weighting to correct mortality for loss to follow-up. We estimated mortality using Cox's proportional hazards and competing risks regression. We tested the interaction between baseline CD4 cell count and age. FINDINGS Between Jan 1, 2004, and Dec 31, 2013, 84,078 eligible adults started ART. Of these, we followed up 83,566 patients for 174,640 patient-years. 8% (1817 of 23,258) of patients aged 16-29 years died compared with 19% (93 of 492) of patients aged 65 years or older. The age adjusted mortality hazard ratio was 2·52 (95% CI 2·01-3·17) for people aged 65 years or older compared with those 16-29 years of age. In patients starting ART with a CD4 count of less than 50 cells per μL, the adjusted mortality hazard ratio was 2·52 (2·04-3·11) for people aged 50 years or older compared with those 16-39 years old. Mortality was highest in patients with CD4 counts of less than 50 cells per μL, and 15% (1103 of 7295) of all patients aged 50 years or older starting ART were in this group. The proportion of patients aged 50 years or older enrolling in ART increased with successive years, from 6% (290 of 4999) in 2004 to 10% (961 of 9657) in 2012-13, comprising 9% of total enrolment (7295 of 83 566). At the end of the study, 6304 (14%) of 44,909 patients still alive and in care were aged 50 years or older. INTERPRETATION Health services need reorientation towards HIV diagnosis and starting of ART in older individuals. Policies are needed for long-term care of older people with HIV. FUNDING National Institutes of Health (National Institute of Allergy and Infectious Diseases), US Agency for International Development, and South African Centre for Epidemiological Modelling and Analysis.
Resumo:
PURPOSE To evaluate a low-cost, inertial sensor-based surgical navigation solution for periacetabular osteotomy (PAO) surgery without the line-of-sight impediment. METHODS Two commercial inertial measurement units (IMU, Xsens Technologies, The Netherlands), are attached to a patient's pelvis and to the acetabular fragment, respectively. Registration of the patient with a pre-operatively acquired computer model is done by recording the orientation of the patient's anterior pelvic plane (APP) using one IMU. A custom-designed device is used to record the orientation of the APP in the reference coordinate system of the IMU. After registration, the two sensors are mounted to the patient's pelvis and acetabular fragment, respectively. Once the initial position is recorded, the orientation is measured and displayed on a computer screen. A patient-specific computer model generated from a pre-operatively acquired computed tomography scan is used to visualize the updated orientation of the acetabular fragment. RESULTS Experiments with plastic bones (eight hip joints) performed in an operating room comparing a previously developed optical navigation system with our inertial-based navigation system showed no statistically significant difference on the measurement of acetabular component reorientation. In all eight hip joints the mean absolute difference was below four degrees. CONCLUSION Using two commercially available inertial measurement units we show that it is possible to accurately measure the orientation (inclination and anteversion) of the acetabular fragment during PAO surgery and therefore to successfully eliminate the line-of-sight impediment that optical navigation systems have.
Resumo:
Acetabular retroversion is the result of an externally rotated hemipelvis rather than a focal overgrowth of the anterior wall and/or hypoplasia of the posterior wall. Acetabular retroversion is a cause of pincer impingement which, if left untreated, can lead to hip pain and osteoarthritis. The causal surgical treatment in hips with acetabular retroversion is acetabular reorientation with a reverse periacetabular osteotomy (PAO). Indication is based on a positive correlation among symptoms (typically groin pain), physical findings on examination (positive anterior impingement test and decreased flexion and internal rotation), and radiographic signs for acetabular retroversion. These include a positive crossover, posterior wall, and ischial spine sign. A reverse PAO is performed with four osteotomies and a controlled fracture. Unlike reorientation of the acetabular fragment in dysplastic hips, correction for acetabular retroversion is achieved by a combined extension and internal rotation of the acetabular fragment. Typically, a small supra-acetabular wedge resection is required to allow sufficient extension of the fragment. The quality of acetabular reorientation is evaluated by intraoperative AP pelvic radiographs. In addition, intraoperative testing of range of motion following acetabular reorientation is mandatory. An arthrotomy and offset correction of the femoral head-neck area is indicated in hips with decreased internal rotation following acetabular reorientation. In a 10-year follow-up study of reverse PAO, a favorable outcome with preservation of all native joints was found. Correct acetabular orientation and, if necessary, a concomitant offset correction were the keys of successful outcome.