80 resultados para Remote diagnostics


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Institute of Applied Physics observes middle atmospheric trace gases, such as ozone and water vapour, by microwave radiometry. We report on the comparison of measurements using a novel digital Fast Fourier Transform and accousto optical spectrometers. First tests made on ground are presented as well as first experience about the use of such spectrometers under aircraft conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As holoprosencephaly and Chiari II malformation differ considerably, both in pathogenesis and in phenotypic localization, the coincidence of both entities is extremely rare. The case presented is, to our knowledge, the first published report comprising a combination of a semilobar holoprosencephaly associated with a Chiari II malformation and a myelomeningocele diagnosed prenatally and confirmed by postmortem neuropathologic evaluation. These findings indicate that in the case of pre- and postnatal detection of a myelomeningocele and/or Chiari II malformation, possible additional intracranial malformation, such as a semilobar holoprosencephaly, should also be taken into account and vice versa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two years ago, CE certified interferon-gamma release assays (IGRA) were launched on the German market (QuantiFERON-TB Gold In-Tube and T-SPOT-TB). Since this time, a multitude of studies have analysed these assays. Guidelines have been elaborated by national expert committees of England, the USA and Switzerland. However, standards of tuberculosis diagnostics and management may vary from country to country. This statement provides practice relevant recommendations for indications, pre-analytics and the interpretation of IGRA test results under different clinical conditions. The IGRA are integrated into existing guidelines for the management of tuberculosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Digital imaging methods are a centrepiece for diagnosis and management of macular disease. A recently developed imaging device is composed of simultaneous confocal scanning laser ophthalmoscopy (SLO) and optical coherence tomography (OCT). By means of clinical samples the benefit of this technique concerning diagnostic and therapeutic follow-up will be assessed. METHODS: The combined OCT-SLO-System (Ophthalmic Technologies Inc., Toronto, Canada) allows for confocal en-face fundus imaging and high resolution OCT scanning at the same time. OCT images are obtained from transversal line scans. One light source and the identical scanning rate yield a pixel-to-pixel correspondence of images. Three-dimensional thickness maps are derived from C-scan stacking. RESULTS: We followed-up patients with cystoid macular edema, pigment epithelium detachment, macular hole, venous branch occlusion, and vitreoretinal tractions during their course of therapy. The new imaging method illustrates the reduction of cystoid volume, e.g. after intravitreal injections of either angiostatic drugs or steroids. C-scans are used for appreciation of lesion diameters, visualisation of pathologies involving the vitreoretinal interface, and quantification of retinal thickness change. CONCLUSION: The combined OCT-SLO system creates both topographic and tomographic images of the retina. New therapeutic options can be followed-up closely by observing changes in lesion thickness and cyst volumes. For clinical use further studies are needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Complete correction of Tetralogy of Fallot, the most common cyanotic congenital heart defect, has now become routine. However, late residual lesions, primarily chronic pulmonary valve insufficiency, may have a negative impact on right-ventricular function, leading to the need for reoperation to insert a competent valve at the right-ventricular outflow. The diagnostic modalities pertaining to the failing right ventricle, the timing for eventual reintervention and the various surgical reconstruction possibilities of the right-ventricular outflow tract are still controversial and evolving, and are reviewed with a brief overview on current trends and future outlooks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this single-center study was to report our initial experience with an implantable remote pressure sensor for aneurysm sac pressure measurement in patients post-endovascular aneurysm repair (EVAR) including short-term follow-up. A pressure sensor (EndoSure, Atlanta, GA) was implanted in 12 patients treated with different commercially available aortic endografts for EVAR. Pressure was read pre- and post-EVAR in the operating room. One-month follow-up (30 days +/- 6 days) was performed including sac pressure readings and IV contrast CT scans. Variables were compared using the paired Student's t test. An intraprocedure type-I endoleak and a type-III endoleak were successfully treated resulting in decreasing sac pressures. In all patients, post-EVAR systolic sac pressure decreased by an average of 33% (P Remote sac pressure measurement may provide important information in addition to imaging and may help to reduce the number of follow-up CT scans.

Relevância:

20.00% 20.00%

Publicador: