102 resultados para Reconstructive dosimetry


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Through the widespread use of postmortem computed tomography, inner livores of the lungs have become a frequently observed phenomenon in the field of forensic medicine. Yet their time-dependent development, notably in comparison with the widely studied external livores, remains poorly understood. We present a unique homicide case where the victim was discovered in supine position with correspondent external livores fixed exclusively on the rear side. Yet upon postmortem computed tomography, the victim presented pronounced inner livores within the depending dorsal areas of both lungs but also vertical sedimentation levels solely within the right lung, suggesting an initial right-hand side position and a postmortem re-positioning of the body. Interestingly, this was consistent with tangible hints of postmortem manipulation on-site. It is likely that this repositioning occurred sometime during the early postmortem interval (<6 h) as the external livores have completely rearranged to the final supine position. The presented case suggests different development patterns of inner and outer livores, highlighting the necessity for controlled studies that explore the formation and fixation processes of livor mortis in internal organs. A better understanding of these issues can prove useful in forensic examinations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Congenital pseudarthrosis of the tibia (CPT) is caused by an ill-defined, segmental disturbance of periosteal bone formation leading to spontaneous bowing, followed by fracture and subsequent pseudarthrosis in the first 2 years of life. The results of conventional treatment modalities (e.g., bracing, internal and external fixation and bone grafting) are associated with high failure rates in terms of persisting pseudarthrosis, malunion and impaired growth. As a more promising alternative, a more aggressive approach, including wide resection of the affected bone, reconstruction with free vascularised fibula grafts from the healthy contralateral leg and stable external fixation at a very early stage has been suggested. Between 1995 and 2007, 10 children (age 12-31 months, median 20 months) suffering from CPT were treated at our institutions according to this principle. Two patients were treated before a fracture had occurred. The length of the fibula graft was 7-9cm. End-to-end anastomoses were performed at the level of the distal tibia stump. The follow-up was 80 months (median, range 12 months to 12 years). Radiologic examination at 6 weeks postoperatively showed normal bone density and structure of the transplanted fibula in all cases and osseous consolidation at 19 of the 20 graft/tibia junctions. One nonunion was sucessfully treated with bone grafting and plate osteosynthesis. Pin-tract infection occurred in three patients. Five children sustained graft fractures that were successfully treated with internal or external fixation. Two patients developed diminished growth of the affected limb or foot; all others had equal limb length and shoe size. At long-term follow-up, tibialisation of the transplant had occurred, and normal gait and physical activities were possible in all children. We conclude that in spite of a relatively high complication rate and the reluctance to perform free flap surgery in infants at this young age, the present concept may successfully prevent the imminent severe sequelae associated with CPT.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Immediate breast reconstruction (IBR) has become an established procedure for women necessitating mastectomy. Traditionally, the nipple-areola complex (NAC) is resected during this procedure. The NAC, in turn, is a principal factor determining aesthetic outcome after breast reconstruction, and due to its particular texture and shape, a natural-looking NAC can barely be reconstructed with other tissues. The aim of this study was to assess the oncological safety as well as morbidity and aesthetic outcome after replantation of the NAC some days after IBR. Retrospective analysis of 85 patients receiving 88 mastectomies and IBR between 1998 and 2007 was conducted. NAC (n=29) or the nipple alone (n=23) were replanted 7 days (median, range 2-10 days) after IBR in 49 patients, provided the subareolar tissue was histologically negative for tumour infiltration. Local recurrence rate was assessed after 49 months (median, range 6-120 months). Aesthetic outcome was evaluated by clinical assessment during routine follow-up at least 12 months after the last intervention. Malignant involvement of the subareolar tissue was found in eight cases (9.1%). Patients qualifying for NAC replantation were in stage 0 in 29%, stage I in 15%, stage IIa in 31%, stage IIb in 17% and stage III in 8%. Total or partial necrosis occurred in 69% and 26% if the entire NAC or only the nipple were replanted, respectively (P<0.01). Depigmentation was seen in 52% and corrective surgery was done in 11 out of 52 NAC or nipple replantations. Local recurrence and isolated regional lymph node metastasis were observed in one single case each. Another 5.8% of the patients showed distant metastases. We conclude that the replantation of the NAC in IBR is oncologically safe, provided the subareolar tissue is free of tumour. However, the long-term aesthetic outcome of NAC replantation is not satisfying, which advocates replanting the nipple alone.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To date, obesity affects a substantial population in industrialised countries. Due to the increased awareness of obesity-related morbidity, efficient dietary regimens and the recent successes with bariatric surgery, there is now a high demand for body contouring surgery to correct skin abundancies after massive weight loss. The known risks for this type of surgery are mainly wound-healing complications, and, more rarely, thromboembolic or respiratory complications. We present two female patients (23 and 39 years of age) who, in spite of standard positioning and precautions, developed sciatic neuropathy after combined body contouring procedures, including abdominoplasty and inner thigh lift. Complete functional loss of the sciatic nerve was found by clinical and electroneurographic examination on the left side in patient one and bilaterally in patient two. Full nerve conductance recovery was obtained after 6 months in both patients. Although the occurrence of spontaneous neuropathies after heavy weight loss is well documented, this is the first report describing the appearance of such a phenomenon following body contouring surgery. One theoretical explanation may be the compression of the nerve during the semirecumbent positioning combined with hip flexion and abduction, which was required for abdominal closure and simultaneous access to the inner thighs. We advise to avoid this positioning and to include the risk of sciatic neuropathy in the routine preoperative information of patients scheduled for body contouring surgery after heavy weight loss.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Owing to its optimal nuclear properties, ready availability, low cost and favourable dosimetry, (99m)Tc continues to be the ideal radioisotope for medical-imaging applications. Bifunctional chelators based on a tetraamine framework exhibit facile complexation with Tc(V)O(2) to form monocationic species with high in vivo stability and significant hydrophilicity, which leads to favourable pharmacokinetics. The synthesis of a series of 1,4,8,11-tetraazaundecane derivatives (01-06) containing different functional groups at the 6-position for the conjugation of biomolecules and subsequent labelling with (99m)Tc is described herein. The chelator 01 was used as a starting material for the facile synthesis of chelators functionalised with OH (02), N(3) (04) and O-succinyl ester (05) groups. A straightforward and easy synthesis of carboxyl-functionalised tetraamine-based chelator 06 was achieved by using inexpensive and commercially available starting materials. Conjugation of 06 to a potent bombesin-antagonist peptide and subsequent labelling with (99m)Tc afforded the radiotracer (99m)Tc-N4-BB-ANT, with radiolabelling yields of >97% at a specific activity of 37 GBq micromol(-1). An IC(50) value of (3.7+/-1.3) nM was obtained, which confirmed the high affinity of the conjugate to the gastrin-releasing-peptide receptor (GRPr). Immunofluorescence and calcium mobilisation assays confirmed the strong antagonist properties of the conjugate. In vivo pharmacokinetic studies of (99m)Tc-N4-BB-ANT showed high and specific uptake in PC3 xenografts and in other GRPr-positive organs. The tumour uptake was (22.5+/-2.6)% injected activity per gram (% IA g(-1)) at 1 h post injection (p.i.). and increased to (29.9+/-4.0)% IA g(-1) at 4 h p.i. The SPECT/computed tomography (CT) images showed high tumour uptake, clear background and negligible radioactivity in the abdomen. The promising preclinical results of (99m)Tc-N4-BB-ANT warrant its potential candidature for clinical translation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study was to evaluate the treatment dosimetry, efficacy and toxicity of intensity modulated radiation therapy (IMRT) and fractionated stereotactic radiotherapy (FSRT) in the management of infratentorial ependymoma. Between 1999 and 2007, seven children (median age, 3.1 years) with infratentorial ependymoma were planned with either IMRT (3 patients) or SFRT (4 patients), the latter after conventional posterior fossa irradiation. Two children underwent gross total resection. Median prescribed dose was 59.4 Gy (range, 55.8-60). The median follow-up for surviving patients was 4.8 years (range, 1.3-8). IMRT (median dose, 59.4 Gy) and FSRT (median dose, 55.8 Gy) achieved similar optimal target coverage. Percentages of maximum doses delivered to the cochleae (59.5 vs 85.0% Gy; P = 0.05) were significantly inferior with IMRT, when compared to FSRT planning. Percentages of maximum doses administered to the pituitary gland (38.2 vs 20.1%; P = 0.05) and optic chiasm (38.1 vs 14.1%; P = 0.001) were, however, significantly higher with IMRT, when compared to FSRT planning. No recurrences were observed at the last follow-up. The estimated 3-year progression-free survival and overall survival were 87.5 and 100%, respectively. No grade >1 acute toxicity was observed. Two patients presented late adverse events (grade 2 hypoacousia) during follow-up, without cognitive impairment. IMRT or FSRT for infratentorial ependymomas is effective and associated with a tolerable toxicity level. Both treatment techniques were able to capitalize their intrinsic conformal ability to deliver high-dose radiation. Larger series of patients treated with these two modalities will be necessary to more fully evaluate these delivery techniques.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Protective patient equipment for CT examinations is not routinely provided. The aim of this study was to determine whether, and if so what, specific protective equipment is beneficial during CT scans. The absorbed organ doses and the effective doses for thorax, abdomen/pelvis and brain CT investigation with and without the use of protective patient equipment have been determined and compared. All measurements were carried out on modern multislice CT scanner using an anthropomorphic phantom and thermoluminescence dosemeters. The measurements show that protective equipment reduces the dose within the scattered beam area. The highest organ dose reduction was found in organs that protrude from the trunk like the testes or the female breasts that can largely be covered by the protective equipment. The most reduction of the effective dose was found in the male abdomen/pelvis examination (0.32 mSv), followed by the brain (0.11 mSv) and the thorax (0.06 mSv). It is concluded that the use of protective equipment can reduce the applied dose to the patient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Major efforts have been undertaken to reduce donor-site morbidity after abdominal flaps, which eventually culminated in the introduction of the deep inferior epigastric perforator (DIEP) flap. However, due to anatomical variations (absence of dominant perforators) and the risk of ischaemic complications, the selection of patients qualifying for a DIEP flap is limited. Furthermore, DIEP flaps can only be used as free flaps. We present our long-term experience with a dissection technique of rectus abdominis myocutaneous (RAM) flaps that was developed to circumvent these drawbacks. The dissection is characterised by preventing to sacrifice any perforators nourishing the flap and by fully preserving the anterior rectus sheath, but not the muscle. The study comprises a consecutive series of prospectively assessed patients, treated between February 2000 and April 2008. A total of 100 fascia-sparing RAM flaps were operated on 97 patients (age 22-84 years, median 64 years). Free flaps were mainly used for breast reconstruction (47 flaps/24 patients), and cranially (34) or caudally (19) pedicled flaps for soft-tissue coverage after sternectomy, urogenital tumour resection or rectum amputation. Eighty patients had a total of 213 risk factors, such as cardiovascular diseases, obesity, hyperlipidaemia, diabetes mellitus, smoking or steroid medication. Partial tissue loss (skin or fat necrosis) occurred in 13 flaps, out of which seven required surgical revision. The ischaemic complications were evenly distributed between the patient subsets. At a follow-up of 2-89 months (median 20 months), one patient showed a flap harvest-related abdominal bulge after bilateral-free transverse rectus abdominis myocutaneous (TRAM) flap. We conclude that the present dissection technique provides maximal perforator-related perfusion and minimal donor-site morbidity even in pedicled flaps and high-risk patients. In free flaps, it may, therefore, be recommended as an alternative to the DIEP flap.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ablative procedures that are used for the improvement of a degenerative process that leads to a loss of skin elasticity and integrity, injure or destroy the epidermis and its basement membrane and lead to fibrosis of the papillary dermis. It was recently shown in clinical and laboratory trials that percutaneous collagen induction (PCI) by multiple needle application is a method for safely treating wrinkles and scars and smoothening the skin without the risk of dyspigmentation. In our study, we describe the effect of PCI on epidermal thickness and the induction of genes relevant for regenerative processes in the skin in a small animal model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Refinement in microvascular reconstructive techniques over the last 30 years has enabled an increasing number of patients to be rehabilitated for both functional and aesthetic reasons. The purpose of this study was to evaluate different microsurgical practice, including perioperative management, in Germany, Austria, and Switzerland. The DÖSAK collaborative group for Microsurgical Reconstruction developed a detailed questionnaire which was circulated to units in the three countries. The current practice of the departments was evaluated. Thirty-eight questionnaires were completed resulting in a 47.5% response rate. A considerable variation in the number of microsurgical reconstructions per year was noted. In relation to the timing of bony reconstruction, 10 hospitals did reconstructions primarily (26.3%), 19 secondarily (50%) and 9 (23.7%) hospitals used both concepts. In the postoperative course, 15.8% of hospitals use inhibitors of platelet aggregation, most hospitals use low molecular heparin (52.6%) or other heparin products (44.7%). This survey shows variation in the performance, management, and care of microsurgical reconstructions of patients. This is due in part to the microvascular surgeons available in the unit but it is also due to different types of hospitals where various types of care can be performed in these patients needing special perioperative care.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As lipofilling of the female breast is becoming more popular in plastic surgery, the use of MRI to assess breast volume has been employed to control postoperative results. Therefore, we sought to evaluate the accuracy of magnetic resonance imaging (MRI)-based breast volumetry software tools by comparing the measurements of silicone implant augmented breasts with the actual implant volume specified by the manufacturer. MRI-based volume analysis was performed in eight bilaterally augmented patients (46 ± 9 years) with three different software programs (Brainlab© I plan 2.6 neuronavigation software; mass analysis, version 5.3, Medis©; and OsiriX© v.3.0.2. 32-bit). The implant volumes analysed by the BrainLab© software had a mean deviation of 2.2 ± 1.7% (r?=?0.99) relative to the implanted prosthesis. OsiriX© software analysis resulted in a mean deviation of 2.8 ± 3.0% (r?=?0.99) and the Medis© software had a mean deviation of 3.1 ± 3.0% (r?=?0.99). Overall, the volumes of all analysed breast implants correlated very well with the real implant volumes. Processing time was 10 min per breast with each system and 30 s (OsiriX©) to 5 min (BrainLab© and Medis©) per silicone implant. MRI-based volumetry is a powerful tool to calculate both native breast and silicone implant volume in situ. All software solutions performed well and the measurements were close to the actual implant sizes. The use of MRI breast volumetry may be helpful in: (1) planning reconstructive and aesthetic surgery of asymmetric breasts, (2) calculating implant size in patients with missing documentation of a previously implanted device and (3) assessing post-operative results objectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The intensive use of nano-sized titanium dioxide (TiO2) particles in many different applications necessitates studies on their risk assessment as there are still open questions on their safe handling and utilization. For reliable risk assessment, the interaction of TiO2 nanoparticles (NP) with biological systems ideally needs to be investigated using physico-chemically uniform and well-characterized NP. In this article, we describe the reproducible production of TiO2 NP aerosols using spark ignition technology. Because currently no data are available on inhaled NP in the 10–50 nm diameter range, the emphasis was to generate NP as small as 20 nm for inhalation studies in rodents. For anticipated in vivo dosimetry analyses, TiO2 NP were radiolabeled with 48V by proton irradiation of the titanium electrodes of the spark generator. The dissolution rate of the 48V label was about 1% within the first day. The highly concentrated, polydisperse TiO2 NP aerosol (3–6 × 106 cm−3) proved to be constant over several hours in terms of its count median mobility diameter, its geometric standard deviation, and number concentration. Extensive characterization of NP chemical composition, physical structure, morphology, and specific surface area was performed. The originally generated amorphous TiO2 NP were converted into crystalline anatase TiO2 NP by thermal annealing at 950 °C. Both crystalline and amorphous 20-nm TiO2 NP were chain agglomerated/aggregated, consisting of primary particles in the range of 5 nm. Disintegration of the deposited TiO2 NP in lung tissue was not detectable within 24 h.