31 resultados para RENAL INSUFFICIENCY


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The "weekend effect" is defined as increased morbidity and mortality for patients admitted on weekends compared with weekdays. It has been observed for several diseases, including myocardial infarction and renal insufficiency; however, it has not yet been investigated for laparoscopic appendectomy in acute appendicitis-one of the most prevalent surgical diagnoses.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Falsely high ankle-brachial index (ABI) values are associated with an adverse clinical outcome in diabetes mellitus. The aim of the present study was to verify whether such an association also exists in patients with chronic critical limb ischemia (CLI) with and without diabetes. A total of 229 patients (74 +/- 11 years, 136 males, 244 limbs with CLI) were followed for 262 +/- 136 days. Incompressibility of lower limb arteries (ABI > 1.3) was found in 45 patients, and was associated with diabetes mellitus (p = 0.01) and renal insufficiency (p = 0.035). Limbs with incompressible ankle arteries had a higher rate of major amputation (p = 0.002 by log-rank). This association was confirmed by multivariate Cox regression analysis (relative risk [RR] 2.67; 95% CI 1.27-5.64, p = 0.01). The relationship between ABI > 1.3 and amputation rate persisted after subjects with diabetes and renal insufficiency had been removed from the analysis (RR 3.85; 95% CI 1.25-11.79, p = 0.018). Dividing limbs with measurable ankle pressure according to tertiles of ABI, the group in the second tertile (0.323 < or = ABI < or = 0.469) had the lowest amputation rate (4/64, 6.2%), and a U-shaped association between the occurrence of major amputation and ABI was evident. No association was found between ABI and mortality. In conclusion, this study demonstrates that falsely high ABI is an independent predictor of major amputation in patients with CLI.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The systemic capillary leak syndrome (SCLS), also known as Clarkson's disease, is a rare disorder characterized by paroxysmal capillary hyperpermeability with a shift of plasma fluid from the intravascular to the interstitial space. A 35-year-old previously healthy woman was admitted with rapidly developing hypovolemic shock syndrome, rhabdomyolysis, and diffuse edema. Laboratory analysis revealed a severe hemoconcentration, renal insufficiency, and paraproteinemia. After exclusion of infection, allergy, burning or drug-induced conditions, the clinical presentation was consistent with the diagnosis of SCLS. Though this is a rare entity, the substantial morbidity and mortality associated with it necessitate the physician's awareness in order to provide timely therapy. This report is meant to enhance awareness of SCLS.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Colchicine is a highly active alkaloid used in the treatment of acute inflammatory syndromes such as Mediterranean fever, M. Behçet or gouty arthritis. The two cases we present here illustrate exemplarily the pros and contras of colchicine therapy. In the first case, colchicine was successfully given for recurrent febrile attacks due to acute rheumatic fever. The second patient unfortunately had a fatal colchicine intoxication. The pharmacology of colchicine, the clinical features associated with overdose and the options for treatment are discussed. Colchicine should not be given in combination with macrolides, especially in patients with renal insufficiency.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Familial hypomagnesemia with hypercalciuria and nephrocalcinosis is an autosomal recessive renal tubular disorder characterized by renal magnesium wasting, hypercalciuria, advanced nephrocalcinosis and progressive renal failure. Mutations in the paracellin-1 (CLDN16) gene have been defined as the underlying genetic defect. The tubular disorders and progression in renal failure are usually resistant to magnesium substitution and hydrochlorothiazide therapy, but hypomagnesemia may improve with advanced renal insufficiency. We present a patient with a homozygous truncating CLDN16 gene mutation (W237X) who had early onset of renal insufficiency despite early diagnosis at 2 months. He also had additional abnormalities including horseshoe kidney, neonatal teeth, atypical face, cardiac abnormalities including coarctation of the aorta associated with atrial and ventricular septal defects, umbilical hernia and hypertrichosis. To the best of our knowledge, this is the youngest case diagnosed as familial hypomagnesemia with hypercalciuria and nephrocalcinosis and the first case having such additional congenital abnormalities independent of the disease itself.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

With prenatal detection of hydronephrosis and technological advances in surgical equipment, the management of lower urinary tract obstruction has evolved to include prenatal surgical intervention. Surgical intervention, was based upon the rationale that restoring amniotic fluid to normal levels by shunting fetal urine from the obstructed urinary system to the amniotic space would prevent lung hypoplasia and, thus, improve neonatal survival. Inaddition, relief of the obstruction would also reduce back pressure and reduce injury to the developing nephron, thus improving long-term renal function postnatally. However, this remains investigational, and the vast majority of affected infants are treated soon after birth. We have experience since 1991 with prenatal treatment of megacystis. In 23 cases of 50 detected megacystis with oligohydramnion in male and without other abnormalities a prenatal intervention by bladderpunction and in 12 cases additional vesicoamniotic shunt placement was performed. The prognosis of megacystis with oligohydramnion is stated with a survival rate of 10-30%. In our group 54% (13 children) survived. Also we want present 56 cases of urethral valves with a postnatal transurethral intervention. With a follow up time from 8.6 (3 to 15) years we attend 34 children (60%) with normal renal function, 21% (12) with mild or moderate renal insufficiency and there was a kidney transplantation in 6 cases necessary. With our multidisciplinary presentation we want to discuss the indication, interdisciplinary aspects,risks and the follow up of pre- and postnatal intervention in such cases.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND Peak levels of troponin T (TnT) reliably predict morbidity and mortality after cardiac surgery. However, the therapeutic window to manage CABG-related in-hospital complications may close before the peak is reached. We investigated whether early TnT levels correlate as well with complications after coronary artery bypass grafting (CABG) surgery. METHODS A 12 month consecutive series of patients undergoing elective isolated CABG procedures (mini-extra-corporeal circuit, Cardioplegic arrest) was analyzed. Logistic regression modeling was used to investigate whether TnT levels 6 to 8 hours after surgery were independently associated with in-hospital complications (either post-operative myocardial infarction, stroke, new-onset renal insufficiency, intensive care unit (ICU) readmission, prolonged ICU stay (>48 hours), prolonged need for vasopressors (>24 hours), resuscitation or death). RESULTS A total of 290 patients, including 36 patients with complications, was analyzed. Early TnT levels (odds ratio (OR): 6.8, 95% confidence interval (CI): 2.2-21.4, P=.001), logistic EuroSCORE (OR: 1.2, 95%CI: 1.0-1.3, P=.007) and the need for vasopressors during the first 6 postoperative hours (OR: 2.7, 95%CI: 1.0-7.1, P=.05) were independently associated with the risk of complications. With consideration of vasopressor use during the first 6 postoperative hours, the sum of specificity (0.958) and sensitivity (0.417) of TnT for subsequent complications was highest at a TnT cut-off value of 0.8 ng/mL. CONCLUSION Early TnT levels may be useful to guide ICU management of CABG patients. They predict clinically relevant complications within a potential therapeutic window, particularly in patients requiring vasopressors during the first postoperative hours, although with only moderate sensitivity.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To systematically investigate putative causes of non-coronary high-sensitive troponin elevations in patients presenting to a tertiary care emergency department. In this cross-sectional analysis, patients who received serial measurements of high-sensitive troponin T between 1 August 2010 and 31 October 2012 at the Department of Emergency Medicine were included. The following putative causes were considered to be associated with non-acute coronary syndrome-related increases in high-sensitive troponin T: acute pulmonary embolism, renal insufficiency, aortic dissection, heart failure, peri-/myocarditis, strenuous exercise, rhabdomyolysis, cardiotoxic chemotherapy, high-frequency ablation therapy, defibrillator shocks, cardiac infiltrative disorders (e.g., amyloidosis), chest trauma, sepsis, shock, exacerbation of chronic obstructive pulmonary disease, and diabetic ketoacidosis. During the study period a total of 1,573 patients received serial measurements of high-sensitive troponin T. Of these, 175 patients were found to have acute coronary syndrome leaving 1,398 patients for inclusion in the study. In 222 (30 %) of patients, no putative cause described in the literature could be attributed to the elevation in high-sensitive troponin T observed. The most commonly encountered mechanism underlying the troponin T elevation was renal insufficiency that was present in 286 patients (57 %), followed by cerebral ischemia in 95 patients (19 %), trauma in 75 patients (15 %) and heart failure in 41 patients (8 %). Non-acute coronary syndrome-associated elevation of high-sensitive troponin T levels is commonly observed in the emergency department. Renal insufficiency and acute cerebral events are the most common conditions associated with high-sensitive troponin T elevation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

AIMS Cystatin C is a well established marker of kidney function. There is evidence that cystatin C concentrations are also associated with mortality. The present analysis prospectively evaluated the associations of cystatin C with all-cause and cardiovascular (CV) mortality in a well-characterized cohort of persons undergoing angiography, but without overt renal insufficiency. METHODS Cystatin C was available in 2998 persons (mean age: 62.7 ± 10.5 years; 30.3% women). Of those 2346 suffered from coronary artery disease (CAD) and 652 (controls) did not. Creatinine (mean ± SD: 83.1 ± 47.8 vs. 74.1 ± 24.7 μmol/L, p = 0.036) but not Cystatin C (mean ± SD: 1.02 ± 0.44 vs. 0.92 ± 0.26 mg/L, p = 0.065) was significantly higher in patients with CAD. After a median follow-up of 9.9 years, in total 898 (30%) deaths occurred, 554 (18.5%) due to CV disease and 326 (10.9%) due to non-CV causes. Multivariable-adjusted Cox analysis (adjusting for eGFR and established cardiovascular risk factors, lipid lowering therapy, angiographic coronary artery disease, and C-reactive protein) revealed that patients in the highest cystatin C quartile were at an increased risk for all-cause (hazard ratio (HR) 1.93, 95% CI 1.50-2.48) and CV mortality (HR 2.05 95% CI 1.48-2.84) compared to those in the lowest quartile. The addition of cystatin C to a model consisting of established cardiovascular risk factors increased the area under the receiver-operating characteristic curve for CV and all-cause mortality, but the difference was statistically not significant. However, reclassification analysis revealed significant improvement by addition of cystatin C for CV and all-cause mortality (p < 0.001), respectively. CONCLUSION The concentration of cystatin C is strongly associated with long-term all-cause and cardiovascular mortality in patients referred to coronary angiography, irrespective of creatinine-based renal function.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND Stroke is a major cause of morbidity and mortality during open-heart surgery. Up to 60% of intraoperative cerebral events are emboli induced. This randomized, controlled, multicenter trial is the first human study evaluating the safety and efficacy of a novel aortic cannula producing simultaneous forward flow and backward suction for extracting solid and gaseous emboli from the ascending aorta and aortic arch upon their intraoperative release. METHODS Sixty-six patients (25 females; 68±10 years) undergoing elective aortic valve replacement surgery, with or without coronary artery bypass graft surgery, were randomized to the use of the CardioGard (CardioGard Medical, Or-Yehuda, Israel) Emboli Protection cannula ("treatment") or a standard ("control") aortic cannula. The primary endpoint was the volume of new brain lesions measured by diffusion-weighted magnetic resonance imaging (DW-MRI), performed preoperatively and postoperatively. Device safety was investigated by comparisons of complications rate, namely neurologic events, stroke, renal insufficiency and death. RESULTS Of 66 patients (34 in the treatment group), 51 completed the presurgery and postsurgery MRI (27 in the treatment group). The volume of new brain lesion for the treatment group was (mean±standard error of the mean) 44.00±64.00 versus 126.56±28.74 mm3 in the control group (p=0.004). Of the treatment group, 41% demonstrated new postoperative lesions versus 66% in the control group (p=0.03). The complication rate was comparable in both groups. CONCLUSIONS The CardioGard cannula is safe and efficient in use during open-heart surgery. Efficacy was demonstrated by the removal of a substantial amount of emboli, a significant reduction in the volume of new brain lesions, and the percentage of patients experiencing new brain lesions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We report the case of a 79 year old woman presenting with progressive confusion and drowsiness. Renal insufficiency with hyperkalemia as well as hypercalcemia and severe hyperphosphatemia were diagnosed. Renal insufficiency improved with treatment. However, hyperphosphatemia persisted without apparent explanation. We discuss possible causes of hyper- and pseudohyperphosphatemia. Specifically, phosphate analysis may be disturbed by the paraproteins in patients with multiple myeloma, resulting in pseudohyperphosphatemia. We review the standard laboratory phosphate measurement and the mechanisms of interference with paraproteins.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUCTION Native-MR angiography (N-MRA) is considered an imaging alternative to contrast enhanced MR angiography (CE-MRA) for patients with renal insufficiency. Lower intraluminal contrast in N-MRA often leads to failure of the segmentation process in commercial algorithms. This study introduces an in-house 3D model-based segmentation approach used to compare both sequences by automatic 3D lumen segmentation, allowing for evaluation of differences of aortic lumen diameters as well as differences in length comparing both acquisition techniques at every possible location. METHODS AND MATERIALS Sixteen healthy volunteers underwent 1.5-T-MR Angiography (MRA). For each volunteer, two different MR sequences were performed, CE-MRA: gradient echo Turbo FLASH sequence and N-MRA: respiratory-and-cardiac-gated, T2-weighted 3D SSFP. Datasets were segmented using a 3D model-based ellipse-fitting approach with a single seed point placed manually above the celiac trunk. The segmented volumes were manually cropped from left subclavian artery to celiac trunk to avoid error due to side branches. Diameters, volumes and centerline length were computed for intraindividual comparison. For statistical analysis the Wilcoxon-Signed-Ranked-Test was used. RESULTS Average centerline length obtained based on N-MRA was 239.0±23.4 mm compared to 238.6±23.5 mm for CE-MRA without significant difference (P=0.877). Average maximum diameter obtained based on N-MRA was 25.7±3.3 mm compared to 24.1±3.2 mm for CE-MRA (P<0.001). In agreement with the difference in diameters, volumes obtained based on N-MRA (100.1±35.4 cm(3)) were consistently and significantly larger compared to CE-MRA (89.2±30.0 cm(3)) (P<0.001). CONCLUSIONS 3D morphometry shows highly similar centerline lengths for N-MRA and CE-MRA, but systematically higher diameters and volumes for N-MRA.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVE The development of peripheral artery disease is affected by the presence of cardiovascular risk factors. It is unclear, whether particular risk factors are leading to different clinical stages of peripheral artery disease. The aim of this retrospective cross-sectional study was to assess the association of cardiovascular risk factors with the presence of critical limb ischaemia. METHODS The study cohort was derived from a consecutive registry of patients undergoing endovascular therapy in a tertiary referral centre between January 2000 and April 2014. Patients undergoing first-time endovascular intervention for chronic peripheral artery disease of the lower extremities were included. Univariate and multivariate logistic regression models were used to assess the association of age, sex, diabetes mellitus, hypertension, dyslipidaemia, smoking, and renal insufficiency with critical limb ischaemia vs. intermittent claudication. RESULTS A total of 3406 patients were included in the study (mean age 71.7 ± 11.8 years, 2075 [61%] male). There was a significant association of age (OR 1.67, 95%-CI 1.53-1.82, p < 0.001), male gender (OR 1.23, 95%-CI 1.04-1.47, p = 0.016), diabetes (OR 1.99, 95%-CI 1.68-2.36, p < 0.001) and renal insufficiency (OR 1.62, 95%-CI 1.35-1.96, p < 0.001) with the likelihood of critical limb ischaemia. Smoking was associated with intermittent claudication rather than critical limb ischaemia (OR 0.78, 95%-CI 0.65-0.94, p = 0.010), while hypertension and dyslipidaemia did not show an association with critical limb ischaemia. CONCLUSIONS In peripheral artery disease patients undergoing first-time endovascular treatment, age, male gender, diabetes, and renal insufficiency were the strongest predictors for the presence of critical limb ischaemia.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES The SOURCE XT Registry (Edwards SAPIEN XT Aortic Bioprosthesis Multi-Region Outcome Registry) assessed the use and clinical outcomes with the SAPIEN XT (Edwards Lifesciences, Irvine, California) valve in the real-world setting. BACKGROUND Transcatheter aortic valve replacement is an established treatment for high-risk/inoperable patients with severe aortic stenosis. The SAPIEN XT is a balloon-expandable valve with enhanced features allowing delivery via a lower profile sheath. METHODS The SOURCE XT Registry is a prospective, multicenter, post-approval study. Data from 2,688 patients at 99 sites were analyzed. The main outcome measures were all-cause mortality, stroke, major vascular complications, bleeding, and pacemaker implantations at 30-days and 1 year post-procedure. RESULTS The mean age was 81.4 ± 6.6 years, 42.3% were male, and the mean logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) was 20.4 ± 12.4%. Patients had a high burden of coronary disease (44.2%), diabetes (29.4%), renal insufficiency (28.9%), atrial fibrillation (25.6%), and peripheral vascular disease (21.2%). Survival was 93.7% at 30 days and 80.6% at 1 year. At 30-day follow-up, the stroke rate was 3.6%, the rate of major vascular complications was 6.5%, the rate of life-threatening bleeding was 5.5%, the rate of new pacemakers was 9.5%, and the rate of moderate/severe paravalvular leak was 5.5%. Multivariable analysis identified nontransfemoral approach (hazard ratio [HR]: 1.84; p < 0.0001), renal insufficiency (HR: 1.53; p < 0.0001), liver disease (HR: 1.67; p = 0.0453), moderate/severe tricuspid regurgitation (HR: 1.47; p = 0.0019), porcelain aorta (HR: 1.47; p = 0.0352), and atrial fibrillation (HR: 1.41; p = 0.0014), with the highest HRs for 1-year mortality. Major vascular complications and major/life-threatening bleeding were the most frequently seen complications associated with a significant increase in 1-year mortality. CONCLUSIONS The SOURCE XT Registry demonstrated appropriate use of the SAPIEN XT THV in the first year post-commercialization in Europe. The safety profile is sustained, and clinical benefits have been established in the real-world setting. (SOURCE XT Registry; NCT01238497).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dent disease is a rare X-linked tubulopathy characterized by low molecular weight proteinuria, hypercalciuria, nephrocalcinosis and/or nephrolithiasis, progressive renal failure, and variable manifestations of other proximal tubule dysfunctions. It often progresses over a few decades to chronic renal insufficiency, and therefore molecular characterization is important to allow appropriate genetic counseling. Two genetic subtypes have been described to date: Dent disease 1 is caused by mutations of the CLCN5 gene, coding for the chloride/proton exchanger ClC-5; and Dent disease 2 by mutations of the OCRL gene, coding for the inositol polyphosphate 5-phosphatase OCRL-1. Herein, we review previously reported mutations (n = 192) and their associated phenotype in 377 male patients with Dent disease 1 and describe phenotype and novel (n = 42) and recurrent mutations (n = 24) in a large cohort of 117 Dent disease 1 patients belonging to 90 families. The novel missense and in-frame mutations described were mapped onto a three-dimensional homology model of the ClC-5 protein. This analysis suggests that these mutations affect the dimerization process, helix stability, or transport. The phenotype of our cohort patients supports and extends the phenotype that has been reported in smaller studies.