31 resultados para Quality criteria


Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND Retinal optical coherence tomography (OCT) permits quantification of retinal layer atrophy relevant to assessment of neurodegeneration in multiple sclerosis (MS). Measurement artefacts may limit the use of OCT to MS research. OBJECTIVE An expert task force convened with the aim to provide guidance on the use of validated quality control (QC) criteria for the use of OCT in MS research and clinical trials. METHODS A prospective multi-centre (n = 13) study. Peripapillary ring scan QC rating of an OCT training set (n = 50) was followed by a test set (n = 50). Inter-rater agreement was calculated using kappa statistics. Results were discussed at a round table after the assessment had taken place. RESULTS The inter-rater QC agreement was substantial (kappa = 0.7). Disagreement was found highest for judging signal strength (kappa = 0.40). Future steps to resolve these issues were discussed. CONCLUSION Substantial agreement for QC assessment was achieved with aid of the OSCAR-IB criteria. The task force has developed a website for free online training and QC certification. The criteria may prove useful for future research and trials in MS using OCT as a secondary outcome measure in a multi-centre setting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Objectives: To assess the reporting quality of Cochrane and non-Cochrane systematic reviews (SR) in orthodontics and to compare the reporting quality (PRISMA score) with methodological quality (AMSTAR criteria). Materials and Methods: Systematic reviews (n  =  109) published between January 2000 and July 2011 in five leading orthodontic journals were identified and included. The quality of reporting of the included reviews was assessed by two authors in accordance with the PRISMA guidelines. Each article was assigned a cumulative grade based on fulfillment of the applicable criteria, and an overall percentage score was assigned. Descriptive statistics and simple and multiple linear regression analyses were undertaken. Results: The mean overall PRISMA score was 64.1% (95% confidence interval [CI], 62%-65%). The quality of reporting was considerably better in reviews published in the Cochrane Database of Systematic Reviews (P < .001) than in non-Cochrane reviews. Both multivariable and univariable analysis indicated that journal of publication and number of authors was significantly associated with the PRISMA score. The association between AMSTAR score and modified PRISMA score was also found to be highly statistically significant. Conclusion: Compliance of orthodontic SRs published in orthodontic journals with PRISMA guidelines was deficient in several areas. The quality of reporting assessed using PRISMA guidelines was significantly better in orthodontic SRs published in the Cochrane Database of Systematic Reviews.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Severe Ménière's disease (MD) may be debilitating and compromising, despite intensive medical treatment. Vestibular neurectomy (VN) is considered an effective surgical treatment for disabling MD. Our aim was to analyse the medium- to long-term outcome after retrosigmoid VN with special regard to vertigo, quality of life (American Academy of Otolaryngology-Head and Neck Surgery criteria), and pure tone average (PTA).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

GOALS OF WORK: The aim of this study was to evaluate pain intensity and the application of the WHO guidelines for cancer pain treatment in patients with prostate cancer treated at Swiss cancer centers. MATERIALS AND METHODS: We analyzed a series of five multicenter phase II clinical trials which examined the palliative effect of different chemotherapies in patients with advanced hormone-refractory prostate carcinoma. Of 170 patients, 1,018 visits were evaluable for our purpose, including ratings of pain intensity by patients and prescribed analgesics. MAIN RESULTS: No or mild pain was indicated by patients in 36 to 55% of the visits, more than mild pain in 30 to 46%. In 21% of the visits, the WHO pain treatment criteria (treatment according to one of the three steps; oral, rectal or transdermal application of the main dose; administration on a regular schedule) were fulfilled, and the Cleeland index was positive according to all recommendations. In 6% of the visits, neither the WHO criteria were fulfilled nor was the Cleeland index positive. This indicates insufficient pain treatment not following the WHO guidelines and that the prescribed analgesics were not sufficiently potent for the rated pain intensity. CONCLUSIONS: In this selective Swiss sample, the standard of analgesic treatment is high. However, there is still scope for improvement. This cannot solely be solved by improving the knowledge of the physicians. Programs to change the patients' attitude towards cancer pain, training to improve the physicians' communication skills, and institutional changes may be promising strategies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In spite of the facts that magnetic resonance spectroscopy (MRS) is applied as clinical tool in non-specialized institutions and that semi-automatic acquisition and processing tools can be used to produce quantitative information from MRS exams without expert information, issues of spectral quality and quality assessment are neglected in the literature of MR spectroscopy. Even worse, there is no consensus among experts on concepts or detailed criteria of quality assessment for MR spectra. Furthermore, artifacts are not at all conspicuous in MRS and can easily be taken for true, interpretable features. This article aims to increase interest in issues of spectral quality and quality assessment, to start a larger debate on generally accepted criteria that spectra must fulfil to be clinically and scientifically acceptable, and to provide a sample gallery of artifacts, which can be used to raise awareness for potential pitfalls in MRS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this retrospective study was to assess image quality with pulmonary CT angiography (CTA) using 80 kVp and to find anthropomorphic parameters other than body weight (BW) to serve as selection criteria for low-dose CTA. Attenuation in the pulmonary arteries, anteroposterior and lateral diameters, cross-sectional area and soft-tissue thickness of the chest were measured in 100 consecutive patients weighing less than 100 kg with 80 kVp pulmonary CTA. Body surface area (BSA) and contrast-to-noise ratios (CNR) were calculated. Three radiologists analyzed arterial enhancement, noise, and image quality. Image parameters between patients grouped by BW (group 1: 0-50 kg; groups 2-6: 51-100 kg, decadally increasing) were compared. CNR was higher in patients weighing less than 60 kg than in the BW groups 71-99 kg (P between 0.025 and <0.001). Subjective ranking of enhancement (P = 0.165-0.605), noise (P = 0.063), and image quality (P = 0.079) did not differ significantly across all patient groups. CNR correlated moderately strongly with weight (R = -0.585), BSA (R = -0.582), cross-sectional area (R = -0.544), and anteroposterior diameter of the chest (R = -0.457; P < 0.001 all parameters). We conclude that 80 kVp pulmonary CTA permits diagnostic image quality in patients weighing up to 100 kg. Body weight is a suitable criterion to select patients for low-dose pulmonary CTA.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Enquiries among patients on the one hand and experimental and observational studies on the other suggest an influence of stress on inflammatory bowel diseases (IBD). However, since this influence remains hypothetical, further research is essential. We aimed to devise recommendations for future investigations in IBD by means of scrutinizing previously applied methodology. METHODS: We critically reviewed prospective clinical studies on the effect of psychological stress on IBD. Eligible studies were searched by means of the PubMed electronic library and through checking the bibliographies of located sources. RESULTS: We identified 20 publications resulting from 18 different studies. Sample sizes ranged between 10 and 155 participants. Study designs in terms of patient assessment, control variables, and applied psychometric instruments varied substantially across studies. Methodological strengths and weaknesses were irregularly dispersed. Thirteen studies reported significant relationships between stress and adverse outcomes. CONCLUSIONS: Study designs, including accuracy of outcome assessment and repeated sampling of outcomes (i.e. symptoms, clinical, and endoscopic), depended upon conditions like sample size, participants' compliance, and available resources. Meeting additional criteria of sound methodology, like taking into account covariates of the disease and its course, is strongly recommended to possibly improve study designs in future IBD research.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aims of this study were to assess and compare the methodological quality of Cochrane and non-Cochrane systematic reviews (SRs) published in leading orthodontic journals and the Cochrane Database of Systematic Reviews (CDSR) using AMSTAR and to compare the prevalence of meta-analysis in both review types. A literature search was undertaken to identify SRs that consisted of hand-searching five major orthodontic journals [American Journal of Orthodontics and Dentofacial Orthopedics, Angle Orthodontist, European Journal of Orthodontics, Journal of Orthodontics and Orthodontics and Craniofacial Research (February 2002 to July 2011)] and the Cochrane Database of Systematic Reviews from January 2000 to July 2011. Methodological quality of the included reviews was gauged using the AMSTAR tool involving 11 key methodological criteria with a score of 0 or 1 given for each criterion. A cumulative grade was given for the paper overall (0-11); an overall score of 4 or less represented poor methodological quality, 5-8 was considered fair and 9 or greater was deemed to be good. In total, 109 SRs were identified in the five major journals and on the CDSR. Of these, 26 (23.9%) were in the CDSR. The mean overall AMSTAR score was 6.2 with 21.1% of reviews satisfying 9 or more of the 11 criteria; a similar prevalence of poor reviews (22%) was also noted. Multiple linear regression indicated that reviews published in the CDSR (P < 0.01); and involving meta-analysis (β = 0.50, 95% confidence interval 0.72, 2.07, P < 0.001) showed greater concordance with AMSTAR.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Tissue microarray (TMA) technology revolutionized the investigation of potential biomarkers from paraffin-embedded tissues. However, conventional TMA construction is laborious, time-consuming and imprecise. Next-generation tissue microarrays (ngTMA) combine histological expertise with digital pathology and automated tissue microarraying. The aim of this study was to test the feasibility of ngTMA for the investigation of biomarkers within the tumor microenvironment (tumor center and invasion front) of six tumor types, using CD3, CD8 and CD45RO as an example. Methods Ten cases each of malignant melanoma, lung, breast, gastric, prostate and colorectal cancers were reviewed. The most representative H&E slide was scanned and uploaded onto a digital slide management platform. Slides were viewed and seven TMA annotations of 1 mm in diameter were placed directly onto the digital slide. Different colors were used to identify the exact regions in normal tissue (n = 1), tumor center (n = 2), tumor front (n = 2), and tumor microenvironment at invasion front (n = 2) for subsequent punching. Donor blocks were loaded into an automated tissue microarrayer. Images of the donor block were superimposed with annotated digital slides. Exact annotated regions were punched out of each donor block and transferred into a TMA block. 420 tissue cores created two ngTMA blocks. H&E staining and immunohistochemistry for CD3, CD8 and CD45RO were performed. Results All 60 slides were scanned automatically (total time < 10 hours), uploaded and viewed. Annotation time was 1 hour. The 60 donor blocks were loaded into the tissue microarrayer, simultaneously. Alignment of donor block images and digital slides was possible in less than 2 minutes/case. Automated punching of tissue cores and transfer took 12 seconds/core. Total ngTMA construction time was 1.4 hours. Stains for H&E and CD3, CD8 and CD45RO highlighted the precision with which ngTMA could capture regions of tumor-stroma interaction of each cancer and the T-lymphocytic immune reaction within the tumor microenvironment. Conclusion Based on a manual selection criteria, ngTMA is able to precisely capture histological zones or cell types of interest in a precise and accurate way, aiding the pathological study of the tumor microenvironment. This approach would be advantageous for visualizing proteins, DNA, mRNA and microRNAs in specific cell types using in situ hybridization techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE To prospectively evaluate the psychometric properties of the Venous Insufficiency Epidemiological and Economic Study (VEINES-QOL/Sym) questionnaire, an instrument to measure disease-specific quality of life and symptoms in elderly patients with deep vein thrombosis (DVT), and to validate a German version of the questionnaire. METHODS In a prospective multicenter cohort study of patients aged ≥ 65 years with acute venous thromboembolism, we used standard psychometric tests and criteria to evaluate the reliability, validity, and responsiveness of the VEINES-QOL/Sym in patients with acute symptomatic DVT. We also performed an exploratory factor analysis. RESULTS Overall, 352 French- and German-speaking patients were enrolled (response rate of 87 %). Both language versions of the VEINES-QOL/Sym showed good acceptability (missing data, floor and ceiling effects), reliability (internal consistency, item-total and inter-item correlations), validity (convergent, discriminant, known-groups differences), and responsiveness to clinical change over time in elderly patients with DVT. The exploratory factor analysis of the VEINES-QOL/Sym suggested three underlying dimensions: limitations in daily activities, DVT-related symptoms, and psychological impact. CONCLUSIONS The VEINES-QOL/Sym questionnaire is a practical, reliable, valid, and responsive instrument to measure quality of life and symptoms in elderly patients with DVT and can be used with confidence in prospective studies to measure outcomes in such patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BackgroundThe PEmb-QoL is a validated 40-item questionnaire to quantify health-related quality of life in patients having experienced pulmonary embolism (PE). It covers six health dimensions: frequency of complaints, activities of daily living limitations, work-related problems, social limitations, intensity of complaints, and emotional complaints. Originally developed in Dutch and English, we sought to prospectively validate the psychometric properties of a French version of the PEmb-QoL.MethodsWe performed a forward and backward translation of the English version of the PEmb-QoL into French. French-speaking consecutive adult patients with an acute, objectively confirmed PE admitted to the emergency department of a Swiss university hospital between 08/2009 and 09/2011 were recruited telephonically. We used standard psychometric tests and criteria to evaluate the acceptability, reliability, and validity of the French version of the PEmb-QoL. We also performed an exploratory factor analysis.ResultsOverall, 102 patients were enrolled in the study. The French version of the PEmb-QoL showed good reliability (internal consistency, item¿total and inter-item correlations), reproducibility (test-retest reliability), and validity (convergent, discriminant) in French-speaking patients with PE. The exploratory factor analysis suggested three underlying dimensions: limitations in daily activity (items 4b-m, 5a-d), symptoms (items 1a-h and 7), and emotional complaints (items 9a-f and j).ConclusionWe successfully validated the French version of the PEmb-QoL questionnaire in patients with PE. Our results show that the PEmb-QoL is a valuable tool for assessing health-related quality of life after PE in French-speaking patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND The Pulmonary Embolism Quality of Life questionnaire (PEmb-QoL) is a 40-item questionnaire to measure health-related quality of life in patients with pulmonary embolism. It covers six 6 dimensions: frequency of complaints, limitations in activities of daily living, work-related problems, social limitations, intensity of complaints, and emotional complaints. Originally developed in Dutch and English, we prospectively validated a German version of the PEmb-QoL. METHODS A forward-backward translation of the English version of the PEmb-QoL into German was performed. German-speaking consecutive adult patients aged ≥18 years with an acute, objectively confirmed pulmonary embolism discharged from a Swiss university hospital (01/2011-06/2013) were recruited telephonically. Established psychometric tests and criteria were used to evaluate the acceptability, reliability, and validity of the German PEmb-QoL questionnaire. To assess the underlying dimensions, an exploratory factor analysis was performed. RESULTS Overall, 102 patients were enrolled in the study. The German version of the PEmb-QoL showed a good internal consistency (Cronbach's alpha ranging from 0.72 to 0.96), item-total (0.53-0.95) and inter-item correlations (>0.4), and test-retest reliability (intra-class correlation coefficients 0.59-0.89) for the dimension scores. A moderate correlation of the PEmb-QoL with SF-36 dimension and summary scores (0.21-0.83) indicated convergent validity, while low correlations of PEmb-QoL dimensions with clinical characteristics (-0.16-0.37) supported discriminant validity. The exploratory factor analysis suggested four underlying dimensions: limitations in daily activities, symptoms, work-related problems, and emotional complaints. CONCLUSION The German version of the PEmb-QoL questionnaire is a valid and reliable disease-specific measure for quality of life in patients with pulmonary embolism.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE There is debate on how the methodological quality of clinical trials should be assessed. We compared trials of physical therapy (PT) judged to be of adequate quality based on summary scores from the Physiotherapy Evidence Database (PEDro) scale with trials judged to be of adequate quality by Cochrane Risk of Bias criteria. DESIGN Meta-epidemiological study within Cochrane Database of Systematic Reviews. METHODS Meta-analyses of PT trials were identified in the Cochrane Database of Systematic Reviews. For each trial PeDro and Cochrane assessments were extracted from the PeDro and Cochrane databases. Adequate quality was defined as adequate generation of random sequence, concealment of allocation, and blinding of outcome assessors (Cochrane criteria) or as trials with a PEDro summary score ≥5 or ≥6 points. We combined trials of adequate quality using random-effects meta-analysis. RESULTS Forty-one Cochrane reviews and 353 PT trials were included. All meta-analyses included trials with PEDro scores ≥5, 37 (90.2%) included trials with PEDro scores ≥6 and only 22 (53.7%) meta-analyses included trials of adequate quality according to the Cochrane criteria. Agreement between PeDro and Cochrane was poor for PeDro scores of ≥5 points (kappa = 0.12; 95% CI 0.07 to 0.16) and slight for ≥6 points (kappa 0.24; 95% CI 0.16-0.32). When combining effect sizes of trials deemed to be of adequate quality according to PEDro or Cochrane criteria, we found that a substantial difference in the combined effect size (≥0.15) was evident in 9 (22%) out of the 41 meta-analyses for PEDro cutoff ≥5 and 10 (24%) for cutoff ≥6. CONCLUSIONS The PeDro and Cochrane approaches lead to different sets of trials of adequate quality, and different combined treatment estimates from meta-analyses of these trials. A consistent approach to assessing RoB in trials of physical therapy should be adopted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The widespread use of wireless enabled devices and the increasing capabilities of wireless technologies has promoted multimedia content access and sharing among users. However, the quality perceived by the users still depends on multiple factors such as video characteristics, device capabilities, and link quality. While video characteristics include the video time and spatial complexity as well as the coding complexity, one of the most important device characteristics is the battery lifetime. There is the need to assess how these aspects interact and how they impact the overall user satisfaction. This paper advances previous works by proposing and validating a flexible framework, named EViTEQ, to be applied in real testbeds to satisfy the requirements of performance assessment. EViTEQ is able to measure network interface energy consumption with high precision, while being completely technology independent and assessing the application level quality of experience. The results obtained in the testbed show the relevance of combined multi-criteria measurement approaches, leading to superior end-user satisfaction perception evaluation .

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE Patients with biochemical failure (BF) after radical prostatectomy may benefit from dose-intensified salvage radiation therapy (SRT) of the prostate bed. We performed a randomized phase III trial assessing dose intensification. PATIENTS AND METHODS Patients with BF but without evidence of macroscopic disease were randomly assigned to either 64 or 70 Gy. Three-dimensional conformal radiation therapy or intensity-modulated radiation therapy/rotational techniques were used. The primary end point was freedom from BF. Secondary end points were acute toxicity according to the National Cancer Institute Common Terminology Criteria for Adverse Events (version 4.0) and quality of life (QoL) according to the European Organisation for Research and Treatment of Cancer Quality of Life Questionnaires C30 and PR25. RESULTS Three hundred fifty patients were enrolled between February 2011 and April 2014. Three patients withdrew informed consent, and three patients were not eligible, resulting in 344 patients age 48 to 75 years in the safety population. Thirty patients (8.7%) had grade 2 and two patients (0.6%) had grade 3 genitourinary (GU) baseline symptoms. Acute grade 2 and 3 GU toxicity was observed in 22 patients (13.0%) and one patient (0.6%), respectively, with 64 Gy and in 29 patients (16.6%) and three patients (1.7%), respectively, with 70 Gy (P = .2). Baseline grade 2 GI toxicity was observed in one patient (0.6%). Acute grade 2 and 3 GI toxicity was observed in 27 patients (16.0%) and one patient (0.6%), respectively, with 64 Gy, and in 27 patients (15.4%) and four patients (2.3%), respectively, with 70 Gy (P = .8). Changes in early QoL were minor. Patients receiving 70 Gy reported a more pronounced and clinically relevant worsening in urinary symptoms (mean difference in change score between arms, 3.6; P = .02). CONCLUSION Dose-intensified SRT was associated with low rates of acute grade 2 and 3 GU and GI toxicity. The impact of dose-intensified SRT on QoL was minor, except for a significantly greater worsening in urinary symptoms.