29 resultados para Pulsed laser range finder


Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: The present pilot study evaluates the histopathological characteristics and suitability of CO2 and diode lasers for performing excisional biopsies in the buccal mucosa with special emphasis on the extent of the thermal damage zone created. PATIENTS AND METHODS: 15 patients agreed to undergo surgical removal of their fibrous hyperplasias with a laser. These patients were randomly assigned to one diode or two CO2 laser groups. The CO2 laser was used in a continuous wave mode (cw) with a power of 5 W (Watts), and in a pulsed char-free mode (cf). Power settings for the diode laser were 5.12 W in a pulsed mode. The thermal damage zone of the three lasers and intraoperative and postoperative complications were assessed and compared. RESULTS: The collateral thermal damage zone on the borders of the excisional biopsies was significantly smaller with the CO, laser for both settings tested compared to the diode laser regarding values in pm or histopathological index scores. The only intraoperative complication encountered was bleeding, which had to be controlled with electrocauterization. No postoperative complications occurred in any of the three groups. CONCLUSIONS: The CO2 laser seems to be appropriate for excisional biopsies of benign oral mucosal lesions. The CO2 laser offers clear advantages in terms of smaller thermal damage zones over the diode laser. More study participants are needed to demonstrate potential differences between the two different CO2 laser settings tested.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Laser tissue soldering (LTS) is a promising technique for tissue fusion based on a heat-denaturation process of proteins. Thermal damage of the fused tissue during the laser procedure has always been an important and challenging problem. Particularly in LTS of arterial blood vessels strong heating of the endothelium should be avoided to minimize the risk of thrombosis. A precise knowledge of the temperature distribution within the vessel wall during laser irradiation is inevitable. The authors developed a finite element model (FEM) to simulate the temperature distribution within blood vessels during LTS. Temperature measurements were used to verify and calibrate the model. Different parameters such as laser power, solder absorption coefficient, thickness of the solder layer, cooling of the vessel and continuous vs. pulsed energy deposition were tested to elucidate their impact on the temperature distribution within the soldering joint in order to reduce the amount of further animal experiments. A pulsed irradiation with high laser power and high absorbing solder yields the best results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Gynecomastia is the most common breast pathology. Numerous excisions and liposuction techniques have been described to correct bilateral male breast enlargement. Recently, there has been a shift from the open approach to minimally invasive techniques. This article reports a 5-year experience using laser-assisted lipolysis (LAL) to treat gynecomastia, and describes the surgical technique. Between January 2006 and December 2010, a total of 28 patients with bilateral gynecomastia were treated with LAL. Patients had a mean age of 36.5 years (range 24 to 56 years). LAL was performed with a 980-nm diode laser (continuous emission, 15 W power, 8-12 kJ total energy per breast) after tumescent anesthetic infiltration. The breast was evaluated objectively by two physicians who compared chest circumference and photographs. Patients were also asked to score the results using a visual analogue scale: 75 to 100 (very good), 50-74 (good), 25 to 49 (fair) and 0 to 24 (poor). The postoperative period for all patients was incident-free. After 6 months, 18 patients (64.3%) scored the results as "very good", 6 as "good" (21.4%), 3 as "fair" (10.7%) and 1 "poor" (3.6%). Mean chest circumferences pre- and postoperatively were, respectively, 117.4 ± 11.1 cm and 103.3 ± 7.5 cm (p < 0.001), corresponding to a mean difference of 14.1 cm. Physicians scored the photographs as "very good" in 22 patients (78.6%), as "good" in five patients (17.9%), and as "fair" in one patient (3.6%). LAL in gynecomastia is safe and produces significant effects on fatty tissue, with a reduction in breast volume, together with significant skin tightening. Provided an appropriate amount of energy is delivered by an experienced operator, the results are both significant and consistent.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Traditionally, non-invasive monitoring of tidal volume in infants has been performed using impedance plethysmography analyzed using a one or two compartment model. We developed a new laser system for use in infants, which measures antero-posterior movement of the chest wall during quiet sleep. In 24 unsedated or sedated infants (11 healthy, 13 with respiratory disease), we examined whether the analysis of thoracoabdominal movement based on a three compartment model could more accurately estimate tidal volume in comparison to V(T) measured at the mouth. Using five laser signals, chest wall movements were measured at the right and left, upper and lower ribcage and the abdomen. Within the tidal volume range from 4.6 to 135.7 ml, a three compartment model showed good short term repeatability and the best agreement with tidal volume measured at mouth (r(2) = 0.86) compared to that of a single compartment model (r(2) = 0.62, P < 0.0001) and a two compartment model (r(2) = 0.82, P < 0.01), particularly in the presence of respiratory disease. Three compartment modeling of a 5 laser thoracoabdominal monitoring permits more accurate estimates of tidal volume in infants and potentially of regional differences of chest wall displacement in future studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Long-term outcome and complications of diode laser cyclophotocoagulation (DCPC) may be important, since eyes, once treated with DCPC, are less likely to be subjected to other types of interventions in the further follow-up. METHODS: Retrospective review of 131 eyes of 127 patients treated from 2000 through 2004. Success was defined as intraocular pressure (IOP) at last visit 6-21 mm Hg; hypotony: IOP laser energy delivered per eye: 133.9 (73.7) J; mean energy per treatment episode: 86.8 (22.0) J. Eyes with 3 or more treatments (11%) had a significantly larger proportion of post-traumatic glaucoma, and patients were significantly younger. All eyes had refractory glaucomas on maximal medication, neovascular glaucoma (NVG) representing the largest subgroup (61%). IOP decreased from 36.9 (10.7) mm Hg pretreatment to 15.3 (10.4) mm Hg at the end of FU. Success was noted in 69.5% (91 eyes), failure (non-response) in 13%. Hypotony occurred in 17.6% eyes, of which 74% had NVG. Hypotony developed after mean 19.3 (11.0) months, range 6 to 36; with 96% of these eyes having received only 1 or 2 treatments; delivered energy did not differ from that in the successful eyes. CONCLUSIONS: DCPC is an efficient treatment for refractory glaucoma. Hypotony, the most common complication, may develop as late as 36 months post-treatment. Diagnostic category and age seem to influence the outcome stronger than laser protocol and delivered energy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to determine the influence of polyvinyl chloride (PVC) wrapping on the performance of two laser fluorescence devices (LF and LFpen) by assessing tooth occlusal surfaces. BACKGROUND DATA: Protection of their tips may influence LF measurements. To date there are no studies evaluating the influence of this protection on the performance of the LFpen on permanent teeth, or comparing it to the original LF device. MATERIALS AND METHODS: One hundred nineteen permanent molars were assessed by two experienced dentists using the LF and the LFpen devices, both with and without PVC wrapping. The teeth were histologically prepared and assessed for caries extension. RESULTS: The LF values with and without PVC wrapping were significantly different. For both LF devices, the sensitivity and accuracy were lower when the PVC wrapping was used. The specificity was statistically significantly higher for the LFpen with PVC. No difference was found between the areas under the ROC curves with and without PVC wrapping. The ICC showed excellent interexaminer agreement. The Bland and Altman method showed a range between the upper and the lower limits of agreement of 63.4 and 57.8 units for the LF device, and 49.4 and 74.2 for the LFpen device, with and without PVC wrapping, respectively. CONCLUSIONS: We found an influence of the PVC wrapping on the performance of the LF and LFpen devices. However, since its influence on detection of occlusal caries lesions is considered for, the use of one PVC layer is suggested to avoid cross-contamination in clinical practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The space-qualified design of a miniaturized laser for pulsed operation at a wavelength of 1064 nm and at repetition rates up to 10 Hz is presented. This laser consists of a pair of diode-laser pumped, actively q-switched Nd:YAG rod oscillators hermetically sealed and encapsulated in an environment of dry synthetic air. The system delivers at least 300 million laser pulses with 50 mJ energy and 5 ns pulse width (FWHM). It will be launched in 2017 aboard European Space Agency’s Mercury Planetary Orbiter as part of the BepiColombo Laser Altimeter, which, after a 6-years cruise, will start recording topographic data from orbital altitudes between 400 and 1500 km above Mercury’s surface.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mass spectrometric analysis of elemental and isotopic compositions of several NIST standards is performed by a miniature laser ablation/ionisation reflectron-type time-of-flight mass spectrometer (LMS) using a fs-laser ablation ion source (775 nm, 190 fs, 1 kHz). The results of the mass spectrometric studies indicate that in a defined range of laser irradiance (fluence) and for a certain number of accumulations of single laser shot spectra, the measurements of isotope abundances can be conducted with a measurement accuracy at the per mill level and at the per cent level for isotope concentrations higher and lower than 100 ppm, respectively. Also the elemental analysis can be performed with a good accuracy. The LMS instrument combined with a fs-laser ablation ion source exhibits similar detection efficiency for both metallic and non-metallic elements. Relative sensitivity coefficients were determined and found to be close to one, which is of considerable importance for the development of standard-less instruments. Negligible thermal effects, sample damage and excellent characteristics of the fs-laser beam are thought to be the main reason for substantial improvement of the instrumental performance compared to other laser ablation mass spectrometers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Key performance features of a miniature laser ablation time-of-flight mass spectrometer designed for in situ investigations of the chemical composition of planetary surfaces are presented. This mass spectrometer is well suited for elemental and isotopic analysis of raw solid materials with high sensitivity and high spatial resolution. In this study, ultraviolet laser radiation with irradiances suitable for ablation (< 1 GW/cm2) is used to achieve stable ion formation and low sample consumption. In comparison to our previous laser ablation studies at infrared wavelengths, several improvements to the experimental setup have been made, which allow accurate control over the experimental conditions and good reproducibility of measurements. Current performance evaluations indicate significant improvements to several instrumental figures of merit. Calibration of the mass scale is performed within a mass accuracy (Δm/m) in the range of 100 ppm, and a typical mass resolution (m/Δm) ~600 is achieved at the lead mass peaks. At lower laser irradiances, the mass resolution is better, about (m/Δm) ~900 for lead, and limited by the laser pulse duration of 3 ns. The effective dynamic range of the instrument was enhanced from about 6 decades determined in previous study up to more than 8 decades at present. Current studies show high sensitivity in detection of both metallic and non-metallic elements. Their abundance down to tens of ppb can be measured together with their isotopic patterns. Due to strict control of the experimental parameters, e.g. laser characteristics, ion-optical parameters and sample position, by computer control, measurements can be performed with high reproducibility. Copyright © 2012 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new online method to analyse water isotopes of speleothem fluid inclusions using a wavelength scanned cavity ring down spectroscopy (WS-CRDS) instrument is presented. This novel technique allows us simultaneously to measure hydrogen and oxygen isotopes for a released aliquot of water. To do so, we designed a new simple line that allows the online water extraction and isotope analysis of speleothem samples. The specificity of the method lies in the fact that fluid inclusions release is made on a standard water background, which mainly improves the δ D robustness. To saturate the line, a peristaltic pump continuously injects standard water into the line that is permanently heated to 140 °C and flushed with dry nitrogen gas. This permits instantaneous and complete vaporisation of the standard water, resulting in an artificial water background with well-known δ D and δ18O values. The speleothem sample is placed in a copper tube, attached to the line, and after system stabilisation it is crushed using a simple hydraulic device to liberate speleothem fluid inclusions water. The released water is carried by the nitrogen/standard water gas stream directly to a Picarro L1102-i for isotope determination. To test the accuracy and reproducibility of the line and to measure standard water during speleothem measurements, a syringe injection unit was added to the line. Peak evaluation is done similarly as in gas chromatography to obtain &delta D; and δ18O isotopic compositions of measured water aliquots. Precision is better than 1.5 ‰ for δ D and 0.4 ‰ for δ18O for water measurements for an extended range (−210 to 0 ‰ for δ D and −27 to 0 ‰ for δ18O) primarily dependent on the amount of water released from speleothem fluid inclusions and secondarily on the isotopic composition of the sample. The results show that WS-CRDS technology is suitable for speleothem fluid inclusion measurements and gives results that are comparable to the isotope ratio mass spectrometry (IRMS) technique.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Telangiectasias of the lower extremities are very common. There are no blinded, randomized, controlled clinical trials comparing laser modalities with the gold standard sclerotherapy, while the few available studies encompass small patients cohorts. OBJECTIVE This prospective, randomized, open-label trial compares the efficacy of sclerotherapy with polidocanol vs. long-pulsed neodymium-doped yttrium aluminium garnet (Nd:YAG) laser in the treatment of leg telangiectasias. PATIENTS AND METHODS Fifty-six female patients with primary leg telangiectasias and reticular veins (C1A or S Ep AS 1 PN ) were included in the study. One leg was randomly assigned to get treatment with the multiple synchronized long-pulsed Nd:YAG laser, while the other received foam sclerotherapy with polidocanol 0.5%. The patients were treated in two sessions at intervals of 6 weeks. The patients were evaluated by the handling physician after 6 weeks and 6 months. Two investigators assessed blindly at the end of the study the photographs for clearing of the vessels using a six-point scale from 1 (no change) to 6 (100% cleared). Patients reported about pain sensation and outcome satisfaction. RESULTS According to the handling dermatologist, at the last follow-up, there was an improvement of 30-40% with a median of 3 (IQR 2) and a good improvement of 50-70% with a median of 4 (IQR 2) after laser treatment and sclerotherapy respectively. In contrast, according to the blinded investigators, there was a median of 5 (IQR 1) with a very good improvement of >70% after both therapies. Improvement was achieved more quickly by sclerotherapy, although at the last follow-up visit there was no difference in clearance between the two groups as assessed by the blinded experts (P-value 0.84). The degree of patient's satisfaction was very good and similar with both therapeutic approaches. There was a significant difference (P-value 0.003) regarding pain perception between the types of therapy. Laser was felt more painful than sclerotherapy. CONCLUSION Telangiectasias of the lower extremities can be successfully treated with either synchronized long-pulsed Nd:YAG laser or sclerotherapy. The 1064-nm long-pulsed Nd:YAG laser is associated with more pain and is suitable especially in case of needle phobia, allergy to sclerosants and in presence of small veins with telangiectatic matting, while sclerotherapy can also treat the feeder veins.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Satellite laser ranging (SLR) to the satellites of the global navigation satellite systems (GNSS) provides substantial and valuable information about the accuracy and quality of GNSS orbits and allows for the SLR-GNSS co-location in space. In the framework of the NAVSTAR-SLR experiment two GPS satellites of Block-IIA were equipped with laser retroreflector arrays (LRAs), whereas all satellites of the GLONASS system are equipped with LRAs in an operational mode. We summarize the outcome of the NAVSTAR-SLR experiment by processing 20 years of SLR observations to GPS and 12 years of SLR observations to GLONASS satellites using the reprocessed microwave orbits provided by the center for orbit determination in Europe (CODE). The dependency of the SLR residuals on the size, shape, and number of corner cubes in LRAs is studied. We show that the mean SLR residuals and the RMS of residuals depend on the coating of the LRAs and the block or type of GNSS satellites. The SLR mean residuals are also a function of the equipment used at SLR stations including the single-photon and multi-photon detection modes. We also show that the SLR observations to GNSS satellites are important to validate GNSS orbits and to assess deficiencies in the solar radiation pressure models. We found that the satellite signature effect, which is defined as a spread of optical pulse signals due to reflection from multiple reflectors, causes the variations of mean SLR residuals of up to 15 mm between the observations at nadir angles of 0∘ and 14∘. in case of multi-photon SLR stations. For single-photon SLR stations this effect does not exceed 1 mm. When using the new empirical CODE orbit model (ECOM), the SLR mean residual falls into the range 0.1–1.8 mm for high-performing single-photon SLR stations observing GLONASS-M satellites with uncoated corner cubes. For best-performing multi-photon stations the mean SLR residuals are between −12.2 and −25.6 mm due to the satellite signature effect.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Port-wine stains (PWS) are malformations of capillaries in 0.3% of newborn children. The treatment of choice is by pulsed dye LASER (PDL), and requires several sessions. The efficacy of this treatment is at present evaluated on the basis of clinical inspection and of digital photographs taken throughout the treatment. LASER-Doppler imaging (LDI) is a noninvasive method of imaging the perfusion of the tissues by the microcirculatory system (capillaries). The aim of this paper is to demonstrate that LDI allows a quantitative, numerical evaluation of the efficacy of the PDL treatment of PWS. METHOD The PDL sessions were organized according to the usual scheme, every other month, from September 1, 2012, to September 30, 2013. LDI imaging was performed at the start and at the conclusion of the PDL treatment, and simultaneously on healthy skin in order to obtain reference values. The results evidenced by LDI were analyzed according to the "Wilcoxon signed-rank" test before and after each session, and in the intervals between the three PDL treatment sessions. RESULTS Our prospective study is based on 20 new children. On average, the vascularization of the PWS was reduced by 56% after three laser sessions. Compared with healthy skin, initial vascularization of PWS was 62% higher than that of healthy skin at the start of treatment, and 6% higher after three sessions. During the 2 months between two sessions, vascularization of the capillary network increased by 27%. CONCLUSION This study shows that LDI can demonstrate and measure the efficacy of PDL treatment of PWS in children. The figures obtained when measuring the results by LDI corroborate the clinical assessments and may allow us to refine, and perhaps even modify, our present use of PDL and thus improve the efficacy of the treatment.