60 resultados para Protection of personal information


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background The accumulation of mutations after long-lasting exposure to a failing combination antiretroviral therapy (cART) is problematic and severely reduces the options for further successful treatments. Methods We studied patients from the Swiss HIV Cohort Study who failed cART with nucleoside reverse transcriptase inhibitors (NRTIs) and either a ritonavir-boosted PI (PI/r) or a non-nucleoside reverse transcriptase inhibitor (NNRTI). The loss of genotypic activity <3, 3–6, >6 months after virological failure was analyzed with Stanford algorithm. Risk factors associated with early emergence of drug resistance mutations (<6 months after failure) were identified with multivariable logistic regression. Results Ninety-nine genotypic resistance tests from PI/r-treated and 129 from NNRTI-treated patients were analyzed. The risk of losing the activity of ≥1 NRTIs was lower among PI/r- compared to NNRTI-treated individuals <3, 3–6, and >6 months after failure: 8.8% vs. 38.2% (p = 0.009), 7.1% vs. 46.9% (p<0.001) and 18.9% vs. 60.9% (p<0.001). The percentages of patients who have lost PI/r activity were 2.9%, 3.6% and 5.4% <3, 3–6, >6 months after failure compared to 41.2%, 49.0% and 63.0% of those who have lost NNRTI activity (all p<0.001). The risk to accumulate an early NRTI mutation was strongly associated with NNRTI-containing cART (adjusted odds ratio: 13.3 (95% CI: 4.1–42.8), p<0.001). Conclusions The loss of activity of PIs and NRTIs was low among patients treated with PI/r, even after long-lasting exposure to a failing cART. Thus, more options remain for second-line therapy. This finding is potentially of high relevance, in particular for settings with poor or lacking virological monitoring.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A confocal imaging and image processing scheme is introduced to visualize and evaluate the spatial distribution of spectral information in tissue. The image data are recorded using a confocal laser-scanning microscope equipped with a detection unit that provides high spectral resolution. The processing scheme is based on spectral data, is less error-prone than intensity-based visualization and evaluation methods, and provides quantitative information on the composition of the sample. The method is tested and validated in the context of the development of dermal drug delivery systems, introducing a quantitative uptake indicator to compare the performances of different delivery systems is introduced. A drug penetration study was performed in vitro. The results show that the method is able to detect, visualize and measure spectral information in tissue. In the penetration study, uptake efficiencies of different experiment setups could be discriminated and quantitatively described. The developed uptake indicator is a step towards a quantitative assessment and, in a more general view apart from pharmaceutical research, provides valuable information on tissue composition. It can potentially be used for clinical in vitro and in vivo applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

From conventional radiography to cross-sectional imaging methods, modern radiology offers a wide range of diagnostic tools for investigating patients with fever. To achieve the best results and to yield a correct diagnosis, the radiologist must tailor the diagnostic protocol individually for every patient. The decision on the most suitable imaging method, and the type and timing of contrast media strongly depends on the suspected diagnosis. Based on patient history and laboratory data, some modalities may be contraindicated or the patient may need a premedication. The authors give a short overview of diagnostic strategies in evaluating the most important causes of fever and point to the need of discussion and co-operation between clinicians and radiologists.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Graphical displays of results allow researchers to summarise and communicate the key findings of their study. Diagnostic information should be presented in an easily interpretable way, which conveys both test characteristics (diagnostic accuracy) and the potential for use in clinical practice (predictive value). METHODS: We discuss the types of graphical display commonly encountered in primary diagnostic accuracy studies and systematic reviews of such studies, and systematically review the use of graphical displays in recent diagnostic primary studies and systematic reviews. RESULTS: We identified 57 primary studies and 49 systematic reviews. Fifty-six percent of primary studies and 53% of systematic reviews used graphical displays to present results. Dot-plot or box-and- whisker plots were the most commonly used graph in primary studies and were included in 22 (39%) studies. ROC plots were the most common type of plot included in systematic reviews and were included in 22 (45%) reviews. One primary study and five systematic reviews included a probability-modifying plot. CONCLUSION: Graphical displays are currently underused in primary diagnostic accuracy studies and systematic reviews of such studies. Diagnostic accuracy studies need to include multiple types of graphic in order to provide both a detailed overview of the results (diagnostic accuracy) and to communicate information that can be used to inform clinical practice (predictive value). Work is required to improve graphical displays, to better communicate the utility of a test in clinical practice and the implications of test results for individual patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Exposimeters are increasingly applied in bioelectromagnetic research to determine personal radiofrequency electromagnetic field (RF-EMF) exposure. The main advantages of exposimeter measurements are their convenient handling for study participants and the large amount of personal exposure data, which can be obtained for several RF-EMF sources. However, the large proportion of measurements below the detection limit is a challenge for data analysis. With the robust ROS (regression on order statistics) method, summary statistics can be calculated by fitting an assumed distribution to the observed data. We used a preliminary sample of 109 weekly exposimeter measurements from the QUALIFEX study to compare summary statistics computed by robust ROS with a naïve approach, where values below the detection limit were replaced by the value of the detection limit. For the total RF-EMF exposure, differences between the naïve approach and the robust ROS were moderate for the 90th percentile and the arithmetic mean. However, exposure contributions from minor RF-EMF sources were considerably overestimated with the naïve approach. This results in an underestimation of the exposure range in the population, which may bias the evaluation of potential exposure-response associations. We conclude from our analyses that summary statistics of exposimeter data calculated by robust ROS are more reliable and more informative than estimates based on a naïve approach. Nevertheless, estimates of source-specific medians or even lower percentiles depend on the assumed data distribution and should be considered with caution.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: This study tested whether feelings of personal control over one's life circumstances (i.e., personal mastery) would attenuate the relations between stress (i.e., negative life events and caregiving distress) and Plasminogen Activator Inhibitor (PAI)-1 antigen, an inhibitor of fibrinolysis implicated in the development of cardiovascular disease. DESIGN: Seventy-one spousal dementia caregivers were assessed for plasma levels of PAI-1 antigen, negative life events, caregiver distress, and feelings of personal mastery. Regression analysis was used to determine if personal mastery moderated the relations between stress (i.e., life stress and caregiving distress) and PAI-1 antigen levels. MAIN OUTCOME MEASURE: Plasminogen activator inhibitor (PAI)-1 antigen in plasma. RESULTS: After controlling for other factors associated with PAI-1 antigen levels, negative life events were positively associated with plasma PAI-1 antigen concentrations in participants low in personal mastery (beta = .31; p = .050) but not in individuals high in personal mastery (beta = .22; p = .184). The moderating effect of mastery on the relations between caregiving distress and PAI-1 antigen did not reach statistical significance (p = .091). CONCLUSIONS: These data suggest that mastery may protect individuals from some of the alterations in hemostatic factors that have been linked to cardiovascular risk.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Little is known about the population's exposure to radio frequency electromagnetic fields (RF-EMF) in industrialized countries. OBJECTIVES: To examine levels of exposure and the importance of different RF-EMF sources and settings in a sample of volunteers living in a Swiss city. METHODS: RF-EMF exposure of 166 volunteers from Basel, Switzerland, was measured with personal exposure meters (exposimeters). Participants carried an exposimeter for 1 week (two separate weeks in 32 participants) and completed an activity diary. Mean values were calculated using the robust regression on order statistics (ROS) method. RESULTS: Mean weekly exposure to all RF-EMF sources was 0.13 mW/m(2) (0.22 V/m) (range of individual means 0.014-0.881 mW/m(2)). Exposure was mainly due to mobile phone base stations (32.0%), mobile phone handsets (29.1%) and digital enhanced cordless telecommunications (DECT) phones (22.7%). Persons owning a DECT phone (total mean 0.15 mW/m(2)) or mobile phone (0.14 mW/m(2)) were exposed more than those not owning a DECT or mobile phone (0.10 mW/m(2)). Mean values were highest in trains (1.16 mW/m(2)), airports (0.74 mW/m(2)) and tramways or buses (0.36 mW/m(2)), and higher during daytime (0.16 mW/m(2)) than nighttime (0.08 mW/m(2)). The Spearman correlation coefficient between mean exposure in the first and second week was 0.61. CONCLUSIONS: Exposure to RF-EMF varied considerably between persons and locations but was fairly consistent within persons. Mobile phone handsets, mobile phone base stations and cordless phones were important sources of exposure in urban Switzerland.