25 resultados para Polarization modulation infrared structural absorbance spectroscopy
Resumo:
The aim of this study was to investigate the effects of inner and heard speech on cerebral hemodynamics and oxygenation in the anterior prefrontal cortex (PFC) using functional near-infrared spectroscopy and to test whether potential effects were caused by alterations in the arterial carbon dioxide pressure (PaCO2). Twenty-nine healthy adult volunteers performed six different tasks of inner and heard speech according to a randomized crossover design. During the tasks, we generally found a decrease in PaCO2 (only for inner speech), tissue oxygen saturation (StO2), oxyhemoglobin ([O2Hb]), total hemoglobin ([tHb]) concentration and an increase in deoxyhemoglobin concentration ([HHb]). Furthermore, we found significant relations between changes in [O2Hb], [HHb], [tHb], or StO2 and the participants’ age, the baseline PETCO2, or certain speech tasks. We conclude that changes in breathing during the tasks led to lower PaCO2 (hypocapnia) for inner speech. During heard speech, no significant changes in PaCO2 occurred, but the decreases in StO2, [O2Hb], and [tHb] suggest that changes in PaCO2 were also involved here. Different verse types (hexameter and alliteration) led to different changes in [tHb], implying different brain activations. In conclusion, StO2, [O2Hb], [HHb], and [tHb] are affected by interplay of both PaCO2 reactivity and functional brain activity.
Resumo:
The aim was to investigate the effect of mechanical pain stimulation at the lower back on hemodynamic and oxygenation changes in the prefrontal cortex (PFC) assessed by functional near-infrared spectroscopy (fNIRS) and on the partial pressure of end-tidal carbon dioxide ( PetCO 2) measured by capnography. 13 healthy subjects underwent three measurements (M) during pain stimulation using pressure pain threshold (PPT) at three locations, i.e., the processus spinosus at the level of L4 (M1) and the lumbar paravertebral muscles at the level of L1 on the left (M2) and the right (M3) side. Results showed that only in the M2 condition the pain stimulation elicited characteristic patterns consisting of (1) a fNIRS-derived decrease in oxy- and total hemoglobin concentration and tissue oxygen saturation, an increase in deoxy-hemoglobin concentration, (2) a decrease in the PetCO 2 response and (3) a decrease in coherence between fNIRS parameters and PetCO 2 responses in the respiratory frequency band (0.2-0.5 Hz). We discuss the comparison between M2 vs. M1 and M3, suggesting that the non-significant findings in the two latter measurements were most likely subject to effects of the different stimulated tissues, the stimulated locations and the stimulation order. We highlight that PetCO 2 is a crucial parameter for proper interpretation of fNIRS data in experimental protocols involving pain stimulation. Together, our data suggest that the combined fNIRS-capnography approach has potential for further development as pain monitoring method, such as for evaluating clinical pain treatment.
Resumo:
This year marks the 20th anniversary of functional near-infrared spectroscopy and imaging (fNIRS/fNIRI). As the vast majority of commercial instruments developed until now are based on continuous wave technology, the aim of this publication is to review the current state of instrumentation and methodology of continuous wave fNIRI. For this purpose we provide an overview of the commercially available instruments and address instrumental aspects such as light sources, detectors and sensor arrangements. Methodological aspects, algorithms to calculate the concentrations of oxy- and deoxyhemoglobin and approaches for data analysis are also reviewed. From the single-location measurements of the early years, instrumentation has progressed to imaging initially in two dimensions (topography) and then three (tomography). The methods of analysis have also changed tremendously, from the simple modified Beer-Lambert law to sophisticated image reconstruction and data analysis methods used today. Due to these advances, fNIRI has become a modality that is widely used in neuroscience research and several manufacturers provide commercial instrumentation. It seems likely that fNIRI will become a clinical tool in the foreseeable future, which will enable diagnosis in single subjects.
Resumo:
Introduction In several studies, we found that during guided rhythmic speech exercises, a decrease in cerebral hemodynamics and oxygenation occurred as the result of a decrease in the partial pressure of carbon dioxide in the arterial blood (PaCO2) during speaking. To further explore the effect of PaCO2 variations on cerebral hemodynamics and oxygenation, the aim of the present study was to investigate the impact of spoken, inner and heard speech tasks on these parameters. Material and Methods Speech tasks included recitation or inner recitation or listening to hexameter, alliteration, prose, or performing mental arithmetic. The following physiological parameters were measured: tissue oxygen saturation (StO2) and absolute concentrations of oxyhemoglobin, deoxyhemoglobin, total hemoglobin (over the left and right anterior prefrontal cortex, using an ISS OxiplexTS frequency domain near-infrared spectrometer) and end-tidal CO2 (PETCO2; using Nellcor N1000 and Datex NORMOCAP capnographs). Statistical analysis was applied to the differences between baseline, 2 tasks, and 3 post-baseline periods. Data of 3 studies with 24, 7 and 29 healthy subjects, respectively, were combined, and linear regression analyses were calculated. Results Linear regression analyses revealed significant relations between changes in oxyhemoglobin, deoxyhemoglobin, total hemoglobin or StO2 and the participants’ age, the baseline PETCO2 or certain speech tasks. While hexameter verses affected changes during the tasks, alliteration verses only affected changes during the recovery phase. Discussion and Conclusion The observed effects in hemodynamics and oxygenation indicate a combination of neurovascular coupling (increased neuronal activity leading to an increase in the cerebral metabolic rate of oxygen resulting in an increase in cerebral flood flow/volume) and CO2 reactivity (increased breathing during speech tasks causing a decrease in PaCO2 leading to vasoconstriction and decrease in cerebral blood flow). The neurovascular coupling characteristics are task-dependent. References Scholkmann F, Gerber U, Wolf M, Wolf U. End-tidal CO2: An important parameter for a correct interpretation in functional brain studies using speech tasks. Neuroimage 2013;66:71-79. Scholkmann F, Wolf M, Wolf U. The effect of inner speech on arterial CO2, cerebral hemodynamics and oxygenation – A functional NIRS study. Adv Exp Med Biol 2013;789:81-87.
Resumo:
Electron-microprobe analysis, single-crystal X-ray diffraction with an area detector, and high-resolution transmission electron microscopy show that minerals related to wagnerite, triplite and triploidite, which are monoclinic Mg, Fe and Mn phosphates with the formula Me2+ 2PO4(F,OH), constitute a modulated series based on the average triplite structure. Modulation occurs along b and may be commensurate with (2b periodicity) or incommensurate but generally close to integer values (∼3b, ∼5b, ∼7b, ∼9b), i.e. close to polytypic behaviour. As a result, the Mg- and F-dominant minerals magniotriplite and wagnerite can no longer be considered polymorphs of Mg2PO4F, i.e., there is no basis for recognizing them as distinct species. Given that wagnerite has priority (1821 vs. 1951), the name magniotriplite should be discarded in favour of wagnerite. Hydroxylwagnerite, end-member Mg2PO4OH, occurs in pyrope megablasts along with talc, clinochlore, kyanite, rutile and secondary apatite in two samples from lenses of pyrope–kyanite–phengite–quartz-schist within metagranite in the coesite-bearing ultrahigh-pressure metamorphic unit of the Dora-Maira Massif, western Alps, Vallone di Gilba, Val Varaita, Piemonte, Italy. Electron microprobe analyses of holotype hydroxylwagnerite and of the crystal with the lowest F content gave in wt%: P2O5 44.14, 43.99; SiO2 0.28, 0.02; SO3 –, 0.01; TiO2 0.20, 0.16; Al2O3 0.06, 0.03; MgO 48.82, 49.12; FeO 0.33, 0.48; MnO 0.01, 0.02; CaO 0.12, 0.10; Na2O 0.01, –; F 5.58, 4.67; H2O (calc) 2.94, 3.36; –O = F 2.35, 1.97; Sum 100.14, 99.98, corresponding to (Mg1.954Fe0.007Ca0.003Ti0.004Al0.002Na0.001)Σ=1.971(P1.003Si0.008)Σ=1.011O4(OH0.526F0.474)Σ=1 and (Mg1.971Fe0.011Ca0.003Ti0.003Al0.001)Σ=1.989(P1.002Si0.001)Σ=1.003O4(OH0.603F0.397)Σ=1, respectively. Due to the paucity of material, H2O could not be measured, so OH was calculated from the deficit in F assuming stoichiometry, i.e., by assuming F + OH = 1 per formula unit. Holotype hydroxylwagnerite is optically biaxial (+), α 1.584(1), β 1.586(1), γ 1.587(1) (589 nm); 2V Z(meas.) = 43(2)°; orientation Y = b. Single-crystal X-ray diffraction gives monoclinic symmetry, space group P21/c, a = 9.646(3) Å, b = 12.7314(16) Å, c = 11.980(4) Å, β = 108.38(4) , V = 1396.2(8) Å3, Z = 16, i.e., hydroxylwagnerite is the OH-dominant analogue of wagnerite [β-Mg2PO4(OH)] and a high-pressure polymorph of althausite, holtedahlite, and α- and ε-Mg2PO4(OH). We suggest that the group of minerals related to wagnerite, triplite and triploidite constitutes a triplite–triploidite super-group that can be divided into F-dominant phosphates (triplite group), OH-dominant phosphates (triploidite group), O-dominant phosphates (staněkite group) and an OH-dominant arsenate (sarkinite). The distinction among the three groups and a potential fourth group is based only on chemical features, i.e., occupancy of anion or cation sites. The structures of these minerals are all based on the average triplite structure, with a modulation controlled by the ratio of Mg, Fe2+, Fe3+ and Mn2+ ionic radii to (O,OH,F) ionic radii.
Resumo:
Abstract: Near-infrared spectroscopy (NIRS) enables the non-invasive measurement of changes in hemodynamics and oxygenation in tissue. Changes in light-coupling due to movement of the subject can cause movement artifacts (MAs) in the recorded signals. Several methods have been developed so far that facilitate the detection and reduction of MAs in the data. However, due to fixed parameter values (e.g., global threshold) none of these methods are perfectly suitable for long-term (i.e., hours) recordings or were not time-effective when applied to large datasets. We aimed to overcome these limitations by automation, i.e., data adaptive thresholding specifically designed for long-term measurements, and by introducing a stable long-term signal reconstruction. Our new technique (“acceleration-based movement artifact reduction algorithm”, AMARA) is based on combining two methods: the “movement artifact reduction algorithm” (MARA, Scholkmann et al. Phys. Meas. 2010, 31, 649–662), and the “accelerometer-based motion artifact removal” (ABAMAR, Virtanen et al. J. Biomed. Opt. 2011, 16, 087005). We describe AMARA in detail and report about successful validation of the algorithm using empirical NIRS data, measured over the prefrontal cortex in adolescents during sleep. In addition, we compared the performance of AMARA to that of MARA and ABAMAR based on validation data.
Resumo:
Understanding nuclear and electronic dynamics of molecular systems has advanced considerably by probing their nonlinear responses with a suitable sequence of pulses. Moreover, the ability to control crucial parameters of the excitation pulses, such as duration, sequence, frequency, polarization, slowly varying envelope, or carrier phase, has led to a variety of advanced time-resolved spectroscopic methodologies. Recently, two-dimensional electronic spectroscopy with ultrashort pulses has become a more and more popular tool since it allows to obtain information on energy and coherence transfer phenomena, line broadening mechanisms, or the presence of quantum coherences in molecular complexes. Here, we present a high fidelity two-dimensional electronic spectroscopy setup designed for molecular systems in solution. It incorporates the versatility of pulse-shaping methods to achieve full control on the amplitude and phase of the individual exciting and probing pulses. Selective and precise amplitude- and phase-modulation is shown and applied to investigate electronic dynamics in several reference molecular systems.