22 resultados para Plugin eclipse


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a secondary eclipse observation for the hot Jupiter HD 189733b across the wavelength range 290-570 nm made using the Space Telescope Imaging Spectrograph on the Hubble Space Telescope. We measure geometric albedos of Ag = 0.40 ± 0.12 across 290-450 nm and Ag < 0.12 across 450-570 nm at 1σ confidence. The albedo decrease toward longer wavelengths is also apparent when using six wavelength bins over the same wavelength range. This can be interpreted as evidence for optically thick reflective clouds on the dayside hemisphere with sodium absorption suppressing the scattered light signal beyond ~450 nm. Our best-fit albedo values imply that HD 189733b would appear a deep blue color at visible wavelengths.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE A beamlet based direct aperture optimization (DAO) for modulated electron radiotherapy (MERT) using photon multileaf collimator (pMLC) shaped electron fields is developed and investigated. METHODS The Swiss Monte Carlo Plan (SMCP) allows the calculation of dose distributions for pMLC shaped electron beams. SMCP is interfaced with the Eclipse TPS (Varian Medical Systems, Palo Alto, CA) which can thus be included into the inverse treatment planning process for MERT. This process starts with the import of a CT-scan into Eclipse, the contouring of the target and the organs at risk (OARs), and the choice of the initial electron beam directions. For each electron beam, the number of apertures, their energy, and initial shape are defined. Furthermore, the DAO requires dose-volume constraints for the structures contoured. In order to carry out the DAO efficiently, the initial electron beams are divided into a grid of beamlets. For each of those, the dose distribution is precalculated using a modified electron beam model, resulting in a dose list for each beamlet and energy. Then the DAO is carried out, leading to a set of optimal apertures and corresponding weights. These optimal apertures are now converted into pMLC shaped segments and the dose calculation for each segment is performed. For these dose distributions, a weight optimization process is launched in order to minimize the differences between the dose distribution using the optimal apertures and the pMLC segments. Finally, a deliverable dose distribution for the MERT plan is obtained and loaded back into Eclipse for evaluation. For an idealized water phantom geometry, a MERT treatment plan is created and compared to the plan obtained using a previously developed forward planning strategy. Further, MERT treatment plans for three clinical situations (breast, chest wall, and parotid metastasis of a squamous cell skin carcinoma) are created using the developed inverse planning strategy. The MERT plans are compared to clinical standard treatment plans using photon beams and the differences between the optimal and the deliverable dose distributions are determined. RESULTS For the idealized water phantom geometry, the inversely optimized MERT plan is able to obtain the same PTV coverage, but with an improved OAR sparing compared to the forwardly optimized plan. Regarding the right-sided breast case, the MERT plan is able to reduce the lung volume receiving more than 30% of the prescribed dose and the mean lung dose compared to the standard plan. However, the standard plan leads to a better homogeneity within the CTV. The results for the left-sided thorax wall are similar but also the dose to the heart is reduced comparing MERT to the standard treatment plan. For the parotid case, MERT leads to lower doses for almost all OARs but to a less homogeneous dose distribution for the PTV when compared to a standard plan. For all cases, the weight optimization successfully minimized the differences between the optimal and the deliverable dose distribution. CONCLUSIONS A beamlet based DAO using multiple beam angles is implemented and successfully tested for an idealized water phantom geometry and clinical situations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE This paper describes the development of a forward planning process for modulated electron radiotherapy (MERT). The approach is based on a previously developed electron beam model used to calculate dose distributions of electron beams shaped by a photon multi leaf collimator (pMLC). METHODS As the electron beam model has already been implemented into the Swiss Monte Carlo Plan environment, the Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA) can be included in the planning process for MERT. In a first step, CT data are imported into Eclipse and a pMLC shaped electron beam is set up. This initial electron beam is then divided into segments, with the electron energy in each segment chosen according to the distal depth of the planning target volume (PTV) in beam direction. In order to improve the homogeneity of the dose distribution in the PTV, a feathering process (Gaussian edge feathering) is launched, which results in a number of feathered segments. For each of these segments a dose calculation is performed employing the in-house developed electron beam model along with the macro Monte Carlo dose calculation algorithm. Finally, an automated weight optimization of all segments is carried out and the total dose distribution is read back into Eclipse for display and evaluation. One academic and two clinical situations are investigated for possible benefits of MERT treatment compared to standard treatments performed in our clinics and treatment with a bolus electron conformal (BolusECT) method. RESULTS The MERT treatment plan of the academic case was superior to the standard single segment electron treatment plan in terms of organs at risk (OAR) sparing. Further, a comparison between an unfeathered and a feathered MERT plan showed better PTV coverage and homogeneity for the feathered plan, with V95% increased from 90% to 96% and V107% decreased from 8% to nearly 0%. For a clinical breast boost irradiation, the MERT plan led to a similar homogeneity in the PTV compared to the standard treatment plan while the mean body dose was lower for the MERT plan. Regarding the second clinical case, a whole breast treatment, MERT resulted in a reduction of the lung volume receiving more than 45% of the prescribed dose when compared to the standard plan. On the other hand, the MERT plan leads to a larger low-dose lung volume and a degraded dose homogeneity in the PTV. For the clinical cases evaluated in this work, treatment plans using the BolusECT technique resulted in a more homogenous PTV and CTV coverage but higher doses to the OARs than the MERT plans. CONCLUSIONS MERT treatments were successfully planned for phantom and clinical cases, applying a newly developed intuitive and efficient forward planning strategy that employs a MC based electron beam model for pMLC shaped electron beams. It is shown that MERT can lead to a dose reduction in OARs compared to other methods. The process of feathering MERT segments results in an improvement of the dose homogeneity in the PTV.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Video-basiertes Lernen ist besonders effektiv, wo es um Fertigkeiten und Verhalten geht. Videoaufzeichnungen von Gesprächen, Unterrichtssituationen oder der Durchführung praktischer Tätigkeiten wie dem Nähen einer Wunde erlauben es den Ausführenden, ihren Peers und ihren Tutoren, die Qualität der Leistung zu beurteilen und Anregungen zur Verbesserung zu formulieren. Wissend um den grossen didaktischen Wert von Videoaufzeichnungen haben sich vier Pädagogische Hochschulen (Zürich, Freiburg, Thurgau, Luzern) und zwei Medizinische Fakultäten (Bern, Lausanne) zusammen getan, um eine nationale Infrastruktur für Video-unterstütztes Lernen anzustossen. Ziel was es, ein System zu entwickeln, das einfach zu bedienen ist, bei dem viele Arbeitsschritte automatisiert sind und das die Videos im Internet bereit stellt. Zusammen mit SWITCH, der nationalen IT-Support-Organisation der Schweizer Hochschulen, wurde basierend auf den vorbestehenden Technologien AAI und SWITCHcast das Programm iVT (Individual Video Training) entwickelt. Die Integration des nationalen Single Logon System AAI (Authentification and Authorization Infrastructure) erlaubt es, die Videos mit dem jeweiligen User eindeutig zu verknüpfen, so dass die Videos nur für diesen User im Internet zugänglich sind. Mit dem Podcast-System SWITCHcast können Videos automatisch ins Internet hochgeladen und bereit gestellt werden. Es wurden je ein Plugin für die Learning Management Systeme ILIAS (PH Zürich, Uni Bern) und Moodle (Uni Lausanne) entwickelt. Dank dieser Plugins werden die Videos in den jeweiligen LMS verfügbar gemacht. Der Einsatz von iVT ist beim Kommunikationstraining unserer Medizinstudierenden in Bern inzwischen Standard. Das Login gilt gleichzeitig als Beleg für das Testat. Studierende, die keine Videoaufzeichnung wünschen, können diese nach dem Login stoppen. Bis anhin ist das Betrachten der Videos freiwillig. Szenarios mit Peer Feedback sind geplant. Eine entsprechende Erweiterung des Systems um gegenseitige Annotationsmöglichkeiten besteht bereits und wird fortlaufend weiterentwickelt.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Open innovation is increasingly being adopted in business and describes a situation in which firms exchange ideas and knowledge with external participants, such as customers, suppliers, partner firms, and universities. This article extends the concept of open innovation with a push model of open innovation: knowledge is voluntarily created outside a firm by individuals and organisations who proceed to push knowledge into a firm’s open innovation project. For empirical analysis, we examine source code and newsgroup data on the Eclipse Development Platform. We find that outsiders invest as much in the firm’s project as the founding firm itself. Based on the insights from Eclipse, we develop four propositions: ‘preemptive generosity’ of a firm, ‘continuous commitment’, ‘adaptive governance structure’, and ‘low entry barrier’ are contexts that enable the push model of open innovation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

MRSI grids frequently show spectra with poor quality, mainly because of the high sensitivity of MRS to field inhomogeneities. These poor quality spectra are prone to quantification and/or interpretation errors that can have a significant impact on the clinical use of spectroscopic data. Therefore, quality control of the spectra should always precede their clinical use. When performed manually, quality assessment of MRSI spectra is not only a tedious and time-consuming task, but is also affected by human subjectivity. Consequently, automatic, fast and reliable methods for spectral quality assessment are of utmost interest. In this article, we present a new random forest-based method for automatic quality assessment of (1) H MRSI brain spectra, which uses a new set of MRS signal features. The random forest classifier was trained on spectra from 40 MRSI grids that were classified as acceptable or non-acceptable by two expert spectroscopists. To account for the effects of intra-rater reliability, each spectrum was rated for quality three times by each rater. The automatic method classified these spectra with an area under the curve (AUC) of 0.976. Furthermore, in the subset of spectra containing only the cases that were classified every time in the same way by the spectroscopists, an AUC of 0.998 was obtained. Feature importance for the classification was also evaluated. Frequency domain skewness and kurtosis, as well as time domain signal-to-noise ratios (SNRs) in the ranges 50-75 ms and 75-100 ms, were the most important features. Given that the method is able to assess a whole MRSI grid faster than a spectroscopist (approximately 3 s versus approximately 3 min), and without loss of accuracy (agreement between classifier trained with just one session and any of the other labelling sessions, 89.88%; agreement between any two labelling sessions, 89.03%), the authors suggest its implementation in the clinical routine. The method presented in this article was implemented in jMRUI's SpectrIm plugin. Copyright © 2016 John Wiley & Sons, Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Previous studies on issue tracking systems for open source software (OSS) focused mainly on requests for bug fixes. However, requests to add a new feature or an improvement to an OSS project are often also made in an issue tracking system. These inquiries are particularly important because they determine the further development of the software. This study examines if there is any difference between requests of the IBM developer community and other sources in terms of the likelihood of successful implementation. Our study consists of a case study of the issue tracking system BugZilla in the Eclipse integrated development environment (IDE). Our hypothesis, which was that feature requests from outsiders have less chances of being implemented, than feature requests from IBM developers, was confirmed.