110 resultados para Patient-fitted total joint prostheses


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Studies about the influence of patient characteristics on mechanical failure of cups in total hip replacement have applied different methodologies and revealed inconclusive results. The fixation mode has rarely been investigated. Therefore, we conducted a detailed analysis of the influence of patient characteristics and fixation mode on cup failure risks.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The authors report on bilateral simultaneous knee arthroplasty in a 40-year-old male patient with haemophilia A, high inhibitor titre and an aneurysma spurium of the right popliteal artery. Both knees showed a fixed flexion deformity of 20 degrees. To build up haemostasis, treatment with activated prothrombin complex concentrate (APCC) and recombinant activated factor seven (rFVIIa) was initiated preoperatively. A tourniquet was used on both sides during the operation and factor VIII (FVIII) was administered to further correct coagulopathy. On the eleventh postoperative day the patient complained of increasing pain and pressure in the right knee. An ultrasound suggested aneurysm, which was confirmed by substraction angiography. Under the protection of rFVIIa the aneurysm could be coiled and further rehabilitation was uneventful. At one year post-op the patient presented a range of motion of 90/5/0 degrees for both knees and had returned to full time office work. This case indicates that haemophiliacs with high antibody titre and destruction of both knees can be operated on in one session in order to diminish the operative risk of two consecutive surgical procedures, thus allowing an effective rehabilitation programme. Because of the significant frequency of popliteal aneurysms, preoperative angiography is recommended.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We report a series of 16 consecutive total knee arthroplasty (TKA) revision procedures for deep infection, treated with a newly developed intraoperatively moulded PMMA cement-prostheses-like spacer (CPLS). The standard treatment consisted of a two-stage protocol with initial explantation of the infected components combined with radical debridement, followed by implantation of a temporary cement spacer and final reimplantation of a new TKA. A sterilizeable Teflon tapered aluminium mould was developed for production of a custom made CPLS during the intervention. Stable implantation of the CPLS was achieved with a second cementation, allowing for correct alignment and ligament balancing. The spacer remained 3.5 months on average until reimplantation of a TKA occurred. At time of reimplantation, patients had an average KSS score of 84.44 points with an average flexion capacity of 102°. There was no recurrent infection during the study period of minimum 2 years. With this new technique, a low friction articulation with good stability, high comfort and a better range of motion compared to handcrafted spacers was achieved. The use of this spacer is a time sparing, cheap and convenient option in 2-stage TKA revision.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose Total knee arthroplasty (TKA) is currently the international standard of care for treating degenerative and rheumatologic knee joint disease, as well as certain knee joint fractures. We sought to answer the following three research questions: (1) What is the international variance in primary and revision TKA rates around the world? (2) How do patient demographics (e.g., age, gender) vary internationally? (3) How have the rates of TKA utilization changed over time? Methods The survey included 18 countries with a total population of 755 million, and an estimated 1,324,000 annual primary and revision total knee procedures. Ten national inpatient databases were queried for this study from Canada, the United States, Finland, France, Germany, Italy, the Netherlands, Portugal, Spain, and Switzerland. Inpatient data were also compared with published registry data for eight countries with operating arthroplasty registers (Denmark, England & Wales, Norway, Romania, Scotland, Sweden, Australia, and New Zealand). Results The average and median rate of primary and revision (combined) total knee replacement was 175 and 149 procedures/100,000 population, respectively, and ranged between 8.8 and 234 procedures/100,000 population. We observed that the procedure rate significantly increased over time for the countries in which historical data were available. The compound annual growth in the incidence of TKA ranged by country from 5.3% (France) to 17% (Portugal). We observed a nearly 27-fold range of TKA utilization rates between the 18 different countries included in the survey. Conclusion It is apparent from the results of this study that the demand for TKA has risen substantially over the past decade in countries around the world.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We compared revision and mortality rates of 4668 patients undergoing primary total hip and knee replacement between 1989 and 2007 at a University Hospital in New Zealand. The mean age at the time of surgery was 69 years (16 to 100). A total of 1175 patients (25%) had died at follow-up at a mean of ten years post-operatively. The mean age of those who died within ten years of surgery was 74.4 years (29 to 97) at time of surgery. No change in comorbidity score or age of the patients receiving joint replacement was noted during the study period. No association of revision or death could be proven with higher comorbidity scoring, grade of surgeon, or patient gender. We found that patients younger than 50 years at the time of surgery have a greater chance of requiring a revision than of dying, those around 58 years of age have a 50:50 chance of needing a revision, and in those older than 62 years the prosthesis will normally outlast the patient. Patients over 77 years old have a greater than 90% chance of dying than requiring a revision whereas those around 47 years are on average twice as likely to require a revision than die. This information can be used to rationalise the need for long-term surveillance and during the informed consent process.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: We hypothesized that certain patient characteristics have different effects on the risk of early stem loosening in total hip arthroplasty (THA). We therefore conducted a case-control study using register-database records with the aim of identifying patient-specific risk factors associated with radiographic signs of aseptic loosening of the femoral component in THA. METHOD: Data were derived from a multinational European registry and were collected over a period of 25 years. 725 cases with radiographic signs of stem loosening were identified and matched to 4,310 controls without any signs of loosening. Matching criteria were type of implant, size of head, date of operation, center of primary intervention, and follow-up time. The risk factors analyzed were age at operation, sex, diagnosis and previous ipsilateral operations, height, weight, body mass index and mobility based on the Charnley classification. RESULTS: Women showed significantly lower risk of radiographic loosening than men (odds ratio (OR) 0.64). Age was also a strong factor: risk decreased by 1.8% for each additional year of age at the time of surgery. Height and weight were not associated with risk of loosening. A higher body mass index, however, increased the risk of stem loosening to a significant extent (OR 1.03) per additional unit of BMI. Charnley Class B, indicating restricted mobility, was associated with lower risk of loosening (OR 0.78). INTERPRETATION: An increased activity level, as seen in younger patients and those with unrestricted mobility, is an important factor in the etiology of stem loosening. If combined with high BMI, the risk of stem loosening within 10 years is even higher. A younger person should not be denied the benefits of a total hip arthroplasty but must accept that the risk of future failure is increased.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: International registries with large, heterogeneous patient populations provide excellent research opportunities for studying factors that influence treatment outcomes after total hip arthroplasty. In the present study, we used a European multinational database to investigate whether there is an association between three functional variables (preoperative pain, mobility, and motion) and functional outcome. METHODS: We performed a retrospective cohort study on preoperative and follow-up clinical data that were prospectively entered into the International Documentation and Evaluation System European hip registry between 1967 and 2002. The inclusion criteria for this study were an age of more than twenty years, an underlying diagnosis of osteoarthritis, and a Charnley class-A functional designation at the time of surgery. A total of 12,925 patients (13,766 total hip arthroplasties) who met these criteria were entered into the analysis. Three functional variables (pain, mobility, and motion) that were assessed preoperatively were evaluated postoperatively at various follow-up examinations for a maximum of ten years. RESULTS: Six thousand four hundred and one patients could walk longer than ten minutes preoperatively; of these, 57.1% had a walking capacity of more than sixty minutes at the time of the most recent follow-up. In comparison, 6896 patients had a preoperative walking capacity of less than ten minutes and only 38.9% of these patients could walk more than sixty minutes at the time of the most recent follow-up. The difference was significant (p < 0.01). Similarly, 10,375 patients had a preoperative hip flexion range of >70 degrees ; of these, 74.7% had a flexion range of >90 degrees at the time of the most recent follow-up. In comparison, 2793 patients had a preoperative hip flexion range of <70 degrees and only 62.6% of these patients had a flexion range of >90 degrees at the time of the most recent follow-up. The difference was also significant (p < 0.01). Lasting, complete, or almost complete pain relief was achieved by >80% of the patients following total hip arthroplasty regardless of their preoperative categorization of pain. CONCLUSIONS: Patients with poor preoperative walking capacity and hip flexion are less likely to achieve an optimal outcome with regard to walking and motion. In contrast, there is no correlation between the preoperative pain level and pain alleviation, which is generally good and long-lasting after total hip arthroplasty.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES The aim of this study was to identify common risk factors for patient-reported medical errors across countries. In country-level analyses, differences in risks associated with error between health care systems were investigated. The joint effects of risks on error-reporting probability were modelled for hypothetical patients with different health care utilization patterns. DESIGN Data from the Commonwealth Fund's 2010 lnternational Survey of the General Public's Views of their Health Care System's Performance in 11 Countries. SETTING Representative population samples of 11 countries were surveyed (total sample = 19,738 adults). Utilization of health care, coordination of care problems and reported errors were assessed. Regression analyses were conducted to identify risk factors for patients' reports of medical, medication and laboratory errors across countries and in country-specific models. RESULTS Error was reported by 11.2% of patients but with marked differences between countries (range: 5.4-17.0%). Poor coordination of care was reported by 27.3%. The risk of patient-reported error was determined mainly by health care utilization: Emergency care (OR = 1.7, P < 0.001), hospitalization (OR = 1.6, P < 0.001) and the number of providers involved (OR three doctors = 2.0, P < 0.001) are important predictors. Poor care coordination is the single most important risk factor for reporting error (OR = 3.9, P < 0.001). Country-specific models yielded common and country-specific predictors for self-reported error. For high utilizers of care, the probability that errors are reported rises up to P = 0.68. CONCLUSIONS Safety remains a global challenge affecting many patients throughout the world. Large variability exists in the frequency of patient-reported error across countries. To learn from others' errors is not only essential within countries but may also prove a promising strategy internationally.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

INTRODUCTION Even though arthroplasty of the ankle joint is considered to be an established procedure, only about 1,300 endoprostheses are implanted in Germany annually. Arthrodeses of the ankle joint are performed almost three times more often. This may be due to the availability of the procedure - more than twice as many providers perform arthrodesis - as well as the postulated high frequency of revision procedures of arthroplasties in the literature. In those publications, however, there is often no clear differentiation between revision surgery with exchange of components, subsequent interventions due to complications and subsequent surgery not associated with complications. The German Orthopaedic Foot and Ankle Association's (D. A. F.) registry for total ankle replacement collects data pertaining to perioperative complications as well as cause, nature and extent of the subsequent interventions, and postoperative patient satisfaction. MATERIAL AND METHODS The D. A. F.'s total ankle replacement register is a nation-wide, voluntary registry. After giving written informed consent, the patients can be added to the database by participating providers. Data are collected during hospital stay for surgical treatment, during routine follow-up inspections and in the context of revision surgery. The information can be submitted in paper-based or online formats. The survey instruments are available as minimum data sets or scientific questionnaires which include patient-reported outcome measures (PROMs). The pseudonymous clinical data are collected and evaluated at the Institute for Evaluative Research in Medicine, University of Bern/Switzerland (IEFM). The patient-related data remain on the register's module server in North Rhine-Westphalia, Germany. The registry's methodology as well as the results of the revisions and patient satisfaction for 115 patients with a two year follow-up period are presented. Statistical analyses are performed with SAS™ (Version 9.4, SAS Institute, Inc., Cary, NC, USA). RESULTS About 2½ years after the register was launched there are 621 datasets on primary implantations, 1,427 on follow-ups and 121 records on re-operation available. 49 % of the patients received their implants due to post-traumatic osteoarthritis, 27 % because of a primary osteoarthritis and 15 % of patients suffered from a rheumatic disease. More than 90 % of the primary interventions proceeded without complications. Subsequent interventions were recorded for 84 patients, which corresponds to a rate of 13.5 % with respect to the primary implantations. It should be noted that these secondary procedures also include two-stage procedures not due to a complication. "True revisions" are interventions with exchange of components due to mechanical complications and/or infection and were present in 7.6 % of patients. 415 of the patients commented on their satisfaction with the operative result during the last follow-up: 89.9 % of patients evaluate their outcome as excellent or good, 9.4 % as moderate and only 0.7 % (3 patients) as poor. In these three cases a component loosening or symptomatic USG osteoarthritis was present. Two-year follow-up data using the American Orthopedic Foot and Ankle Society Ankle and Hindfoot Scale (AOFAS-AHS) are already available for 115 patients. The median AOFAS-AHS score increased from 33 points preoperatively to more than 80 points three to six months postoperatively. This increase remained nearly constant over the entire two-year follow-up period. CONCLUSION Covering less than 10 % of the approximately 240 providers in Germany and approximately 12 % of the annually implanted total ankle-replacements, the D. A. F.-register is still far from being seen as a national registry. Nevertheless, geographical coverage and inclusion of "high-" (more than 100 total ankle replacements a year) and "low-volume surgeons" (less than 5 total ankle replacements a year) make the register representative for Germany. The registry data show that the number of subsequent interventions and in particular the "true revision" procedures are markedly lower than the 20 % often postulated in the literature. In addition, a high level of patient satisfaction over the short and medium term is recorded. From the perspective of the authors, these results indicate that total ankle arthroplasty - given a correct indication and appropriate selection of patients - is not inferior to an ankle arthrodesis concerning patients' satisfaction and function. First valid survival rates can be expected about 10 years after the register's start.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This chapter proposed a personalized X-ray reconstruction-based planning and post-operative treatment evaluation framework called iJoint for advancing modern Total Hip Arthroplasty (THA). Based on a mobile X-ray image calibration phantom and a unique 2D-3D reconstruction technique, iJoint can generate patient-specific models of hip joint by non-rigidly matching statistical shape models to the X-ray radiographs. Such a reconstruction enables a true 3D planning and treatment evaluation of hip arthroplasty from just 2D X-ray radiographs whose acquisition is part of the standard diagnostic and treatment loop. As part of the system, a 3D model-based planning environment provides surgeons with hip arthroplasty related parameters such as implant type, size, position, offset and leg length equalization. With this newly developed system, we are able to provide true 3D solutions for computer assisted planning of THA using only 2D X-ray radiographs, which is not only innovative but also cost-effective.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a case of a Rendu-Osler-Weber disease patient with recurrent life threatening epistaxis demanding multiple blood transfusions despite of repetitive endoscopic laser and electrocoagulations, endovascular embolisation, septodermoplasty, and long-term intranasal dressings. As alternative treatment modalities repeatedly failed and the patient became almost permanently dependent on nasal dressing, we performed a highly conformal intensity-modulated radiotherapy of the nasal cavity; a total dose of 50 Gy in 2 Gy single fractions was applied. The therapy was very well tolerated, no acute toxicities occurred. Two weeks after the last radiation dose had been applied, the nasal dressing could be removed without problems. Endoscopical control revealed an almost avascular white mucosa without any trace of bleeding spots; previously existing hemangiomas and crusts had disappeared. After a 1-year-follow up, the patient had no significant recurrent epistaxis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study deals with the determination of the retentive force between primary and secondary telescopic crowns under clinical conditions. Forty-three combined fixed-removable prostheses with a total of 140 double crowns were used for retention force measurement of the telescopic crowns prior to cementation. The crowns had a preparation of 1-2°. A specifically designed measuring device was used. The retentive forces were measured with and without lubrication by a saliva substitute. The measured values were analyzed according to the type of tooth (incisors, canines, premolars, and molars). Additionally, a comparison between lubricated and unlubricated telescopic crowns was done. As maximum retention force value 29.98 N was recorded with a telescopic crown on a molar, while the minimum of 0.08 N was found with a specimen on a canine. The median value of retention force of all telescopic crowns reached 1.93 N with an interquartile distance of 4.35 N. No statistically significant difference between lubricated and unlubricated specimens was found. The results indicate that retention force values of telescopic crowns, measured in clinical practice, are often much lower than those cited in the literature. The measurements also show a wide range. Whether this proves to be a problem for the patient's quality of life or not can however only be established by a comparison of the presented results with a follow-up study involving measurement of intraoral retention and determination by e.g. oral health impact profile.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: The mandibular implant overdenture is a popular treatment modality and is well documented in the literature. Follow-up studies with a long observation period are difficult to perform due to the increasing age of patients. The present data summarize a long-term clinical observation of patients with implant overdentures. MATERIALS AND METHODS: Between 1984 and 1997, edentulous patients were consecutively admitted for treatment with an implant overdenture. The dentures were connected to the implants by means of bars or ball anchors. Regular maintenance was provided with at least one or two scheduled visits per year. Recall attendance and reasons for dropout were analyzed based on the specific history of the patient. Denture maintenance service, relining, repair, and fabrication of new dentures were identified, and complications with the retention devices specified separately. RESULTS: In the time period from 1984 to 2008, 147 patients with a total of 314 implants had completed a follow-up period of >10 years. One hundred one patients were still available in 2008, while 46 patients were not reexamined for various reasons. Compliance was high, with a regular recall attendance of >90%. More than 80% of dentures remained in continuous service. Although major prosthetic maintenance was rather low in relation to the long observation period, visits to a dental hygienist and dentist resulted in an annual visit rate of 1.5 and 2.4, respectively. If new dentures became necessary, these were made in student courses, which increased the treatment time and number of appointments needed. Complications with the retention devices consisted mostly of the mounting of new female retainers, the repair of bars, and the changing of ball anchors. The average number of events and the rate of prosthetic service with ball anchors were significantly higher than those with bars. Twenty-two patients changed from ball anchors to bars; 9 patients switched from a clip bar to a rigid U-shaped bar. CONCLUSIONS: This long-term follow-up study demonstrates that implant overdentures are a favorable solution for edentulous patients with regular maintenance. In spite of specific circumstances in an aging population, it is possible to provide long-term care, resulting in a good prognosis and low risk for this treatment modality. For various reasons the dropout rate can be considerable in elderly patients and prosthetic service must be provided regularly.