178 resultados para Oral implants
Resumo:
To assess the 5-year survival of implant-supported single crowns (SCs) and to describe the incidence of biological, technical, and aesthetic complications. The focused question was: What is the survival rate of implants supporting single crowns and implant-supported crowns with a mean follow-up of 5 years and to which extent do biological, technical, and aesthetic complications occur?
Resumo:
The aim of this systematic review was to assess the optimal number of implants for removable reconstructions.
Resumo:
OBJECTIVES: This study was designed to evaluate the effect of gap width and graft placement on bone healing around implants placed in simulated extraction sockets of various widths in four Labrador dogs. MATERIALS AND METHODS: Five Osseotite implants per dog were placed in the mandible of four dogs. Two implants were inserted into sites with a 2.37 mm and two with a 1 mm gap present between the implants and bone around the coronal 6 mm of the implants in each dog. For one of each gap sizes, the gap was filled with Bio-Oss, and the other two with blood alone. A fifth implant was inserted without a gap and used as a control. Ground sections were prepared from biopsies taken at 4 months and histometric measurements of osseointegration and bone between the threads made for the coronal 6 mm. RESULTS: The medians for osseointegration ranged from 5.2 mm for control to 1-2.6 mm for the test modalities. There were significant differences for linear measurements of osseointegration (chi(2) 18.27; df 4; P=0.0011) and bone area within threads (chi(2) 23.4; df 4; P=0.0001) between test modalities. CONCLUSIONS: The results suggest that the wider the gap around the implants, the less favourable the histological outcome at short time intervals following treatment. They also infer that bone grafting with an organic bovine bone xenograft seems to lead to a more favourable histological outcome for wider circumferential defects but not for narrower defects.
Resumo:
AIM: To investigate the significance of the initial stability of dental implants for the establishment of osseointegration in an experimental capsule model for bone augmentation. MATERIAL AND METHODS: Sixteen male rats were used in the study. In each rat, muscle-periosteal flaps were elevated on the lateral aspect of the mandibular ramus on both sides, resulting in exposure of the bone surface. Small perforations were then produced in the ramus. A rigid, hemispherical Teflon capsule with a diameter of 6 mm and a height of 4 mm and with a hole in its middle portion, prepared to fit the circumference of an ITI HC titanium implant of 2.8 mm in diameter, was fixed to the ramus using 4 mini-screws. On one side of the jaw, the implant was placed through the hole in such a way that its apex did not make contact with the mandibular ramus (test). This placement of the implant did not ensure primary stability. On the other side of the jaw, a similar implant was placed through the hole of the capsule in such a way that contact was made between the implant and the surface of the ramus (control). This provided primary stability of the implant. After placement of the implants, the soft tissues were repositioned over the capsules and sutured. After 1, 3, 6 and 9 months, four animals were sacrificed and subjected to histometric analysis. RESULTS: The mean height of direct bone-to-implant contact of implants with primary stability was 38.8%, 52.9%, 64.6% and 81.3% of the implant length at 1, 3, 6 and 9 months, respectively. Of the bone adjacent to the implant surface, 28.1%, 28.9%, 52.6% and 69.6%, respectively, consisted of mineralized bone. At the test implants, no bone-to-implant contact was observed at any observation time or in any of these non-stabilized specimens. CONCLUSION: The findings of the present study indicate that primary implant stability is a prerequisite for successful osseointegration, and that implant instability results in fibrous encapsulation, thus confirming previously made clinical observations.
Resumo:
AIM: The purpose of this randomized split-mouth clinical trial was to determine the active tactile sensibility between single-tooth implants and opposing natural teeth and to compare it with the tactile sensibility of pairs of natural teeth on the contralateral side in the same mouth (intraindividual comparison). MATERIAL AND METHODS: The hypothesis was that the active tactile sensibilities of the implant side and control side are equivalent. Sixty two subjects (n=36 from Bonn, n=26 from Bern) with single-tooth implants (22 anterior and 40 posterior dental implants) were asked to bite on narrow copper foil strips varying in thickness (5-200 microm) and to decide whether or not they were able to identify a foreign body between their teeth. Active tactile sensibility was defined as the 50% threshold of correct answers estimated by means of the Weibull distribution. RESULTS: The results obtained for the interocclusal perception sensibility differed between subjects far more than they differed between natural teeth and implants in the same individual [implant/natural tooth: 16.7+/-11.3 microm (0.6-53.1 microm); natural tooth/natural tooth: 14.3+/-10.6 microm (0.5-68.2 microm)]. The intraindividual differences only amounted to a mean value of 2.4+/-9.4 microm (-15.1 to 27.5 microm). The result of our statistical calculations showed that the active tactile sensibility of single-tooth implants, both in the anterior and posterior region of the mouth, in combination with a natural opposing tooth is similar to that of pairs of opposing natural teeth (double t-test, equivalence margin: +/-8 microm, P<0.001, power >80%). Hence, the implants could be integrated in the stomatognathic control circuit.
Resumo:
OBJECTIVES: To evaluate whether or not preparation of the implant site with osteotomes instead of drilling may improve peri-implant bone density and/or osseointegration, and whether or not this further improves the predictability of immediate loading of SLA implants. MATERIAL AND METHODS: The second, third, and fourth premolars were extracted in both sides of the mandible in six dogs, and after at least 3 months four SLA implants were inserted into each side of the jaw. In three animals, the implant sites were prepared by means of osteotomes, while standard stepwise drilling was used in the remaining animals. In each side of the jaw, two non-adjacent implants were restored with single crowns 4 days after installation, while the remaining two implants were left without crowns to serve as non-loaded controls. After 2, 4, or 12 weeks of loading, specimens including the implants and surrounding tissues were obtained and processed for histologic analysis of undecalcified sections. RESULTS: All implants placed with osteotomes were lost (five before delivery of the crowns and the rest during the first week after loading). None of the conventionally inserted implants, however, was lost, and histomorphometrical analysis revealed similar soft- and hard peri-implant tissue characteristics at immediately loaded and non-loaded implants at all observation times. Average bone-to-implant contact was 59-72% at immediately loaded implants vs. 60-63% at non-loaded ones. CONCLUSION: Preparation of the implant site by means of osteotomes had a deleterious effect on osseointegration, while immediate loading of single, free-standing, SLA implants following a conventional surgical protocol did not jeopardize their osseointegration.
Resumo:
BACKGROUND: Peri-implantitis is associated with the presence of submarginal plaque, soft-tissue inflammation and advanced breakdown of the supporting bone. The progression of peri-implantitis following varying periods of continuing plaque accumulation has been studied in animal models. OBJECTIVE: The aim of the current experiment was to study the progression of peri-implantitis around implants with different surface roughness. MATERIAL AND METHODS: In five beagle dogs, three implants with either a sandblasted acid-etched surface (SLA) or a polished surface (P) were installed bilaterally in the edentulous premolar regions. After 3 months on a plaque control regimen, experimental peri-implantitis was induced by ligature placement and plaque accumulation was allowed to progress until about 40% of the height of the supporting bone had been lost. After this 4-month period, ligatures were removed and plaque accumulation was continued for an additional 5 months. Radiographs of all implant sites were obtained before and after 'active' experimental peri-implantitis as well as at the end of the experiment. Biopsies were harvested and the tissue samples were prepared for light microscopy. The sections were used for histometric and morphometric examinations. RESULTS: The radiographic examinations indicated that similar amounts of bone loss occurred at SLA and P sites during the active breakdown period, while the progression of bone loss was larger at SLA than at polished sites following ligature removal. The histological examination revealed that both bone loss and the size of the inflammatory lesion in the connective tissue were larger in SLA than in polished implant sites. The area of plaque was also larger at implants with an SLA surface than at implants with a polished surface. CONCLUSION: It is suggested that the progression of peri-implantitis, if left untreated, is more pronounced at implants with a moderately rough surface than at implants with a polished surface.
Resumo:
OBJECTIVES: To assess the microbiota at implants diagnosed with peri-implantitis, implant mucositis, or being clinically healthy. MATERIAL AND METHODS: Clinical and microbiological data were collected from 213 subjects (mean age: 65.7+/-14) with 976 implants in function (mean: 10.8 years, SD+/-1.5). Forty species were identified by the checkerboard DNA-DNA hybridization method. RESULTS: Implant mean % plaque score was 41.8+/-32.4%. Periodontitis defined by bone loss was found in 44.9% of subjects. Implant mucositis was diagnosed in 59% and peri-implantitis in 14.9% of all cases. Neisseria mucosa, Fusobacterium nucleatum sp. nucleatum, F. nucleatum sp. polymorphum, and Capnocytophaga sputigena dominated the implant sub-mucosal microbiota and the sub-gingival microbiota at tooth sites. Implant probing pocket depth at the implant site with the deepest probing depth was correlated with levels of Eikenella corrodens (r=0.16, P<0.05), the levels of F. nucleatum sp. vincentii (r=0.15, P<0.05), Porphyromonas gingivalis (r=0.14, P<0.05), and Micromonas micros (r=0.17, P=0.01). E. corrodens was found in higher levels at implants with mucositis compared with implant health (P<0.05). Subjects who lost teeth due to periodontitis had higher yields of F. nucleatum sp. vincentii (P<0.02) and N. mucosa (P<0.05). Independent of implant status subjects with teeth had higher levels of P. gingivalis (P<0.05), and Leptotrichia buccalis (P<0.05). CONCLUSIONS: At implant sites studied, few bacteria differed by whether subjects were dentate or not or by implant status.
Resumo:
OBJECTIVES: The aim of this prospective study was to evaluate the 5-year performance and success rate of titanium screw-type implants with the titanium plasma spray (TPS) or the sand-blasted, large grit, acid-etched (SLA) surface inserted in a two-stage sinus floor elevation (SFE) procedure in the posterior maxilla. MATERIAL AND METHODS: A total of 59 delayed SFEs were performed in 56 patients between January 1997 and December 2001, using a composite graft with autogenous bone chips combined with deproteinized bovine bone mineral (DBBM) or synthetic porous beta-tricalcium phosphate (beta-TCP). After a healing period averaging 7.75 months, 111 dental implants were inserted. After an additional 8-14-week healing period, all implants were functionally loaded with cemented crowns or fixed partial dentures. The patients were recalled at 12 and 60 months for clinical and radiographic examination. RESULTS: One patient developed an acute infection in the right maxillary sinus after SFE and did not undergo implant therapy. Two of the 111 inserted implants had to be removed because of a developing atypical facial pain, and 11 implants were lost to follow-up and were considered drop-outs. The remaining 98 implants showed favorable clinical and radiographic findings at the 5-year examination. The peri-implant soft tissues were stable over time; the mean probing depths and mean attachment levels did not change during the follow-up period. The measurement of the bone crest levels (DIB values) indicated stability as well. Based on strict success criteria, all 98 implants were considered successfully integrated, resulting in a 5-year success rate of 98% (for TPS implants 89%, for SLA implants 100%). CONCLUSION: This prospective study assessing the performance of dental implants inserted after SFE demonstrated that titanium implants can achieve and maintain successful tissue integration with high predictability for at least 5 years of follow-up in carefully selected patients.
Resumo:
OBJECTIVE: Immediate and early loading of dental implants can simplify treatment and increase overall patient satisfaction. The purpose of this 3-year prospective randomized-controlled multicenter study was to assess the differences in survival rates and bone level changes between immediately and early-loaded implants with a new chemically modified surface (SLActive). This investigation shows interim results obtained after 5 months. MATERIAL AND METHODS: Patients > or =18 years of age missing at least one tooth in the posterior maxilla or mandible were enrolled in the study. Following implant placement, patients received a temporary restoration either on the day of surgery (immediate loading) or 28-34 days after surgery (early loading); restorations consisted of single crowns or two to four unit fixed dental prostheses. Permanent restorations were placed 20-23 weeks following surgery. The primary efficacy variable was change in bone level (assessed by standardized radiographs) from baseline to 5 months; secondary variables included implant survival and success rates. RESULTS: A total of 266 patients were enrolled (118 males and 148 females), and a total of 383 implants were placed (197 and 186 in the immediate and early loading groups, respectively). Mean patient age was 46.3+/-12.8 years. After 5 months, implant survival rates were 98% in the immediate group and 97% in the early group. Mean bone level change from baseline was 0.81+/-0.89 mm in the immediate group and 0.56+/-0.73 mm in the early group (P<0.05). Statistical analysis revealed a significant center effect (P<0.0001) and a significant treatment x center interaction (P=0.008). CONCLUSIONS: The results suggested that Straumann implants with an SLActive can be used predictably in time-critical (early or immediate) loading treatment protocols when appropriate patient selection criteria are observed. The mean bone level changes observed from baseline to 5 months (0.56 and 0.81 mm) corresponded to physiological observations from other studies, i.e., were not clinically significant. The presence of a significant center effect and treatment x center interaction indicated that the differences in bone level changes between the two groups were center dependent.
Resumo:
AIMS: (i) To assess the pattern of early bacterial colonization on titanium oral implants after installation, at 12 weeks and at 12 months, (ii) to compare the microbiota at submucosal implant sites and adjacent subgingival tooth sites and (iii) to assess whether or not early colonization was predictive of 12-month colonization patterns. MATERIAL AND METHODS: Submucosal/subgingival plaque samples from 17 titanium oral implants and adjacent teeth were analyzed by checkerboard DNA-DNA hybridization 30 min, 12 weeks and 12 months after implant installation. RESULTS: At 12 months, none of the inserted implants had been lost or presented with signs of peri-implantitis. The distribution of sites at implants and teeth with bleeding on probing varied between 2% and 11%. Probing pocket depths < or =3 mm were found at 75% of implant sites. At 12 months, the sum of the bacterial counts of 40 species was statistically significantly higher at tooth compared with implant sites (mean difference: 34.4 x 10(5), 95% confidence interval -0.4 to 69.4, P<0.05). At 12 months, higher individual bacterial counts at tooth sites were found for 7/40 species compared with implant sites. Detection or lack of detection of Staphylococcus aureus at implant sites at 12 weeks resulted in the highest positive (e.g. 80%) and negative (e.g. 90%) predictive values, respectively. Between 12 weeks and 12 months, the prevalence of Tannerella forsythia increased statistically significantly at implant sites (P<0.05). Lack of detection of Porphyromonas gingivalis at 12 weeks yielded a negative predictive value of 93.1% of this microorganism being undetectable at implant sites at 12 months. CONCLUSIONS: Within the limits of this study, the findings showed (i) a few differences in the prevalence of bacterial species between implant and adjacent tooth sites at 12 months and (ii) high positive and negative predictive values for selected bacterial species.
Resumo:
AIM: To evaluate the healing outcome of soft tissue dehiscence coverage at implant sites. MATERIAL AND METHODS: Ten patients with one mucosal recession defect at an implant site and a contralateral unrestored clinical crown without recession were recruited. The soft tissue recessions were surgically covered using a coronally advanced flap in combination with a free connective tissue graft. Healing was studied at 1, 3 and 6 months post-operatively. RESULTS: Soft tissue dehiscences were covered with a coronal overcompensation of the flap margin up to 1.2 mm after the procedure. After 1 month, the coverage shrank to a mean of 75%, after 3 months to 70% and after 6 months to 66%. CONCLUSIONS: The implant sites revealed a substantial, clinically significant improvement following coronal mucosal displacement in combination with connective tissue grafting, but in none of the sites, a could complete implant soft tissue dehiscence coverage be achieved.
Resumo:
AIMS: To assess the impact of different implant systems on the clinical conditions and the microbiota at implants, and whether the presence of bacteria at tooth sites was predictive of the presence at implant sites. MATERIALS AND METHODS: Subjects with either AstraTech or Brånemark in function for 7 years were enrolled. Sub-gingival bacterial samples at tooth and implant sites were collected with sterile endodontic paper points, and analyzed by the checkerboard DNA-DNA hybridization method (40 species). RESULTS: Fifty-four subjects, 27 supplied with AstraTech (n=132 implants) and 27 with Brånemark (n=102) implants, were studied. Test tooth sites had significantly less evidence of bleeding on probing (P<0.001) and presence of plaque (P<0.001) than implant test sites. Implant sites presented with deeper probing pocket depth than tooth sites (mean difference: 1.1 mm, standard error of differences: 0.08, 95% confidence intervals (CI): 0.9-1.3, P<0.001). Tannerella forsythia (P<0.05), Capnocytophaga sputigena (P<0.05), Actinomyces israelii (P<0.05) and Lactobacillus acidophilus (P<0.05) were found at higher levels at tooth surfaces. No differences in bacterial load for any species were found between the two implant systems. The odds of being present/absent at tooth and implants sites were only significant for Staphylococcus aureus [odds ratio (OR): 5.2 : 1, 95% CI: 1.4-18.9, P<0.01]. CONCLUSIONS: After 7 years in function, implants presented with deeper probing depths than teeth. S. aureus was commonly present at both teeth and implants sites. S. aureus at tooth sites was predictive of also being present at implant sites.