70 resultados para Obnoxious facility location
Resumo:
The aim of this prospective clinical study was to evaluate the location of paravertebral catheters that were placed using the classical landmark puncture technique and to correlate the distribution of contrast dye injected through the catheters with the extent of somatic block. Paravertebral catheter placement was attempted in 31 patients after video-assisted thoracic surgery. In one patient, an ultrasound-guided approach was chosen after failed catheter placement using the landmark method. A fluoroscopic examination in two planes using contrast dye was followed by injection of local anaesthetic and subsequent clinical testing of the extent of the anaesthetised area. In nine patients (29%), spread of contrast dye was not seen within the paravertebral space as intended. Misplaced catheters were in the epidural space (three patients), in the erector spinae musculature (five patients), and in the pleural space (one patient). There was also a discrepancy between the radiological findings and the observed distribution of loss of sensation. We have demonstrated an unacceptably high misplacement rate of paravertebral catheters using the landmark method. Additional research is required to compare the efficacy and safety of continuous paravertebral block using ultrasound-guided techniques or surgical inserted catheters.
High accuracy alignment facility for the receiver and transmitter of the BepiColombo Laser Altimeter
Resumo:
The accurate co-alignment of the transmitter to the receiver of the BepiColombo Laser Altimeter is a challenging task for which an original alignment concept had to be developed. We present here the design, construction and testing of a large collimator facility built to fulfill the tight alignment requirements. We describe in detail the solution found to attenuate the high energy of the instrument laser transmitter by an original beam splitting pentaprism group. We list the different steps of the calibration of the alignment facility and estimate the errors made at each of these steps. We finally prove that the current facility is ready for the alignment of the flight instrument. Its angular accuracy is 23 μrad.
Resumo:
The melanocortin-4 receptor (MC4R) is expressed in the hypothalamus and regulates energy intake and body weight. In silico screening of the canine chromosome 1 sequence and a comparison with the porcine MC4R sequence by BLAST were performed. The nucleotide sequence of the whole coding region and 3'- and 5'-flanking regions of the dog (1214 bp) and red fox (1177 bp) MC4R gene was established and high conservation of the nucleotide sequences was revealed (99%). Five sets of PCR primers were designed and a search for polymorphism was performed by the SSCP technique in a group of 31 dogs representing nineteen breeds and 35 farm red foxes. Sequencing of DNA fragments, representing the identified SSCP patterns, revealed three single nucleotide polymorphisms (including a missense one) in dogs and four silent SNPs in red foxes. An average SNP frequency was approx. 1/400 bp in the dog and 1/300 bp in the red fox. We mapped the MC4R gene by FISH to the canine chromosome 1 (CFA1q1.1) and to the red fox chromosome 5 (VVU5p1.2).
Resumo:
Pleomorphic adenomas primarily arise in the major salivary glands, especially in the parotid. The most common area is the lower pole superficial to the plane of the facial nerve. In this report, a pleomorphic adenoma in an atypical location--the region of the temporomandibular joint (TMJ)--is presented. The tumor was solitary, closely attached to the capsule of the TMJ and superior to the parotid gland, with clear demarcation. Clinically, the tumor resembled TMJ pathology, but MRI examination led to diagnosis of a benign tumor attached to the TMJ. This report shows that pleomorphic adenoma can be a possible diagnosis for lesions at the joint capsule.
Resumo:
1H-magnetic resonance spectroscopy ((1)H-MRS) of deoxymyoglobin (DMb) provides a means to noninvasively monitor the oxygenation state of human skeletal muscle in work and disease. As shown in this work, it also offers the opportunity to measure the absolute tissue content of DMb, the basic oxygen consumption of resting muscle, and the reperfusion characteristics after release of a pressure cuff. The methodology to determine these tissue properties simultaneously at two positions along the calf is presented. The obtained values are in agreement with invasive determinations. The reproducibility of the (1)H-MRS measurements is established for healthy controls and patients with peripheral arterial disease (PAD). A location dependence in axial direction, as well as differences between controls and patients are demonstrated for all parameters. The reoxygenation time in particular is expected to provide a means to quantitatively monitor therapies aimed at improving muscular perfusion in these patients.