21 resultados para Objective measurement


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present paper is twofold. We first give an overview of the multi-faceted construct of career success with its “objective” (real attainments) and “subjective” (perceived attainments) components and with the different methodologies measuring them (“subjectivist” vs. “objectivist” approaches). We also discuss the relationship between the different components of career success as revealed in the literature. Our second aim is to show that the interrelationship between the different facets of career success varies with the employment context. We analyze subjective and objective career success measures collected from professionals working either in the private sector, in the public sector, or that are self-employed. Our findings show that objective success and subjective success are more closely related in the private and self-employment sectors than in the public sector. Moreover, the interrelationship between objective and subjective success varies with the specific subjective success measure chosen. It is stronger for an “other-referent” subjective success measure than for a “self-referent” subjective success measure. Conclusions regarding the measurement of career success as well as regarding the relevance of subjective success for studying occupational careers are drawn.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present research is concerned with the direction of influence between objective and subjective career success. We conducted a prospective longitudinal study with five waves of measurement that covered a time span of 10 years. Participants were professionals working in different occupational fields (N=1,336). We modelled the changes in objective success (income, hierarchical position), in other-referent subjective success (subjective success as compared to a reference group), and in self-referent subjective success (job satisfaction) by means of latent growth curve analysis. Objective success influenced both the initial level and the growth of other-referent subjective success, but it had no influence on job satisfaction. Most importantly, both measures of subjective success and both their initial levels and their changes had strong influences on the growth of objective success. We conclude that the ‘objective success influences subjective success’ relationship is smaller than might be expected, whereas the ‘subjective success influences objective success’ relationship is larger than might be expected.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Instruments for on-farm determination of colostrum quality such as refractometers and densimeters are increasingly used in dairy farms. The colour of colostrum is also supposed to reflect its quality. A paler or mature milk-like colour is associated with a lower colostrum value in terms of its general composition compared with a more yellowish and darker colour. The objective of this study was to investigate the relationships between colour measurement of colostrum using the CIELAB colour space (CIE L*=from white to black, a*=from red to green, b*=from yellow to blue, chroma value G=visual perceived colourfulness) and its composition. Dairy cow colostrum samples (n=117) obtained at 4·7±1·5 h after parturition were analysed for immunoglobulin G (IgG) by ELISA and for fat, protein and lactose by infrared spectroscopy. For colour measurements, a calibrated spectrophotometer was used. At a cut-off value of 50 mg IgG/ml, colour measurement had a sensitivity of 50·0%, a specificity of 49·5%, and a negative predictive value of 87·9%. Colostral IgG concentration was not correlated with the chroma value G, but with relative lightness L*. While milk fat content showed a relationship to the parameters L*, a*, b* and G from the colour measurement, milk protein content was not correlated with a*, but with L*, b*, and G. Lactose concentration in colostrum showed only a relationship with b* and G. In conclusion, parameters of the colour measurement showed clear relationships to colostral IgG, fat, protein and lactose concentration in dairy cows. Implementation of colour measuring devices in automatic milking systems and milking parlours might be a potential instrument to access colostrum quality as well as detecting abnormal milk.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE Although protocol registration for systematic reviews is still not mandatory, reviewers should be strongly encouraged to register the protocol to identify the methodological approach, including all outcomes of interest. This will minimize the likelihood of biased decisions in reviews, such as selective outcome reporting. A group of international experts convened to address issues regarding the need to develop hierarchical lists of outcome measurement instruments for a particular outcome for metaanalyses. METHODS Multiple outcome measurement instruments exist to measure the same outcome. Metaanalysis of knee osteoarthritis (OA) trials, and the assessment of pain as an outcome, was used as an exemplar to assess how Outcome Measures in Rheumatology (OMERACT), the Cochrane Collaboration, and other international initiatives might contribute in this area. The meeting began with formal presentations of background topics, empirical evidence from the literature, and a brief introduction to 2 existing hierarchical lists of pain outcome measurement instruments recommended for metaanalyses of knee OA trials. RESULTS After discussions, most participants agreed that there is a need to develop a methodology for generation of hierarchical lists of outcome measurement instruments to guide metaanalyses. Tools that could be used to steer development of such a prioritized list are the COSMIN checklist (Consensus-based Standards for the selection of health status Measurement Instruments) and the OMERACT Filter 2.0. CONCLUSION We list meta-epidemiological research agenda items that address the frequency of reported outcomes in trials, as well as methodologies to assess the best measurement properties (i.e., truth, discrimination, and feasibility).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To validate a radioimmunoassay for measurement of procollagen type III amino terminal propeptide (PIIINP) concentrations in canine serum and bronchoalveolar lavage fluid (BALF) and investigate the effects of physiologic and pathologic conditions on PIIINP concentrations. SAMPLE POPULATION Sera from healthy adult (n = 70) and growing dogs (20) and dogs with chronic renal failure (CRF; 10), cardiomyopathy (CMP; 12), or degenerative valve disease (DVD; 26); and sera and BALF from dogs with chronic bronchopneumopathy (CBP; 15) and healthy control dogs (10 growing and 9 adult dogs). PROCEDURE A radioimmunoassay was validated, and a reference range for serum PIIINP (S-PIIINP) concentration was established. Effects of growth, age, sex, weight, CRF, and heart failure on S-PIIINP concentration were analyzed. In CBP-affected dogs, S-PIIINP and BALF-PIIINP concentrations were evaluated. RESULTS The radioimmunoassay had good sensitivity, linearity, precision, and reproducibility and reasonable accuracy for measurement of S-PIIINP and BALF-PIIINP concentrations. The S-PIIINP concentration reference range in adult dogs was 8.86 to 11.48 mug/L. Serum PIIINP concentration correlated with weight and age. Growing dogs had significantly higher S-PIIINP concentrations than adults, but concentrations in CRF-, CMP-, DVD-, or CBP-affected dogs were not significantly different from control values. Mean BALF-PIIINP concentration was significantly higher in CBP-affected dogs than in healthy adults. CONCLUSIONS AND CLINICAL RELEVANCE In dogs, renal or cardiac disease or CBP did not significantly affect S-PIIINP concentration; dogs with CBP had high BALF-PIIINP concentrations. Data suggest that the use of PIIINP as a marker of pathologic fibrosis might be limited in growing dogs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Canine S100 calcium-binding protein A12 (cS100A12) shows promise as biomarker of inflammation in dogs. A previously developed cS100A12-radioimmunoassay (RIA) requires radioactive tracers and is not sensitive enough for fecal cS100A12 concentrations in 79% of tested healthy dogs. An ELISA assay may be more sensitive than RIA and does not require radioactive tracers. OBJECTIVE The purpose of the study was to establish a sandwich ELISA for serum and fecal cS100A12, and to establish reference intervals (RI) for normal healthy canine serum and feces. METHODS Polyclonal rabbit anti-cS100A12 antibodies were generated and tested by Western blotting and immunohistochemistry. A sandwich ELISA was developed and validated, including accuracy and precision, and agreement with cS100A12-RIA. The RI, stability, and biologic variation in fecal cS100A12, and the effect of corticosteroids on serum cS100A12 were evaluated. RESULTS Lower detection limits were 5 μg/L (serum) and 1 ng/g (fecal), respectively. Intra- and inter-assay coefficients of variation were ≤ 4.4% and ≤ 10.9%, respectively. Observed-to-expected ratios for linearity and spiking recovery were 98.2 ± 9.8% (mean ± SD) and 93.0 ± 6.1%, respectively. There was a significant bias between the ELISA and the RIA. The RI was 49-320 μg/L for serum and 2-484 ng/g for fecal cS100A12. Fecal cS100A12 was stable for 7 days at 23, 4, -20, and -80°C; biologic variation was negligible but variation within one fecal sample was significant. Corticosteroid treatment had no clinically significant effect on serum cS100A12 concentrations. CONCLUSIONS The cS100A12-ELISA is a precise and accurate assay for serum and fecal cS100A12 in dogs.