19 resultados para Multiple trauma


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hypothesis: Early recognition of coagulopathy may improve the care of patients with multiple injuries. Rapid thrombelastography (RapidTEG) is a new variant of thrombelastography (TEG), in which coagulation is initiated by the addition of protein tissue factor. The kinetics of coagulation and the times of measurement were compared for two variants of TEG--RapidTEG and conventional TEG, in which coagulation was initiated with kaolin. The measurements were performed on blood samples from 20 patients with multiple injuries. The RapidTEG results were also compared with conventional measurements of blood coagulation. The mean time for the RapidTEG test was 19.2 +/- 3.1 minutes (mean +/- SD), in comparison with 29.9 +/- 4.3 minutes for kaolin TEG and 34.1 +/- 14.5 minutes for conventional coagulation tests. The mean time for the RapidTEG test was 30.8 +/- 5.72 minutes, in comparison with 41.5 +/- 5.66 minutes for kaolin TEG and 64.9 +/- 18.8 for conventional coagulation tests---measured from admission of the patients to the resuscitation bay until the results were available. There were significant correlations between the RapidTEG results and those from kaolin TEG and conventional coagulation tests. RapidTEG is the most rapid available test for providing reliable information on coagulopathy in patients with multiple injuries. This has implications for improving patient care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND The pathogenesis of full-thickness tears of the rotator cuff remains unclear. Apart from age and trauma, distinct scapular morphologies have been found to be associated with rotator cuff disease. The purpose of the present study was to evaluate whether a score formed using these established risk factors was able to predict the presence of a rotator cuff tear reliably. METHODS We retrospectively assessed a consecutive series of patients with a minimal age of 40 years old, who had true antero-posterior (AP) radiographs of their shoulders, as well as a magnetic resonance (MR) gadolinium-arthrography, between January and December 2011. In all of these patients, the critical shoulder angle (CSA) was determined, and MR images were assessed for the presence of rotator cuff tears. Additionally, the patients' charts were reviewed to obtain details of symptom onset. Based on these factors, the so-called rotator cuff tear (RCT) score was calculated. RESULTS Patients with full-thickness RCTs were significantly older and had significantly larger CSAs than patients with intact rotator cuffs. Multiple logistic regression, using trauma, age and CSA as independent variables, revealed areas under the curve (AUCs) for trauma of 0.55, for age of 0.65 and for CSA of 0.86. The combination of all three factors was the most powerful predictor, with an AUC of 0.92. CONCLUSION Age, trauma and the CSA can accurately predict the presence of a posterosuperior RCT. LEVEL OF EVIDENCE Level IV. Case series with no comparison groups.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND The assessment of hemodynamic status is a crucial task in the initial evaluation of trauma patients. However, blood pressure and heart rate are often misleading, as multiple variables may impact these conventional parameters. More reliable methods such as pulmonary artery thermodilution for cardiac output measuring would be necessary, but its applicability in the Emergency Department is questionable due to their invasive nature. Non-invasive cardiac output monitoring devices may be a feasible alternative. METHODS A systematic literature review was conducted. Only studies that explicitly investigated non-invasive hemodynamic monitoring devices in trauma patients were considered. RESULTS A total of 7 studies were identified as suitable and were included into this review. These studies evaluated in a total of 1,197 trauma patients the accuracy of non-invasive hemodynamic monitoring devices by comparing measurements to pulmonary artery thermodilution, which is the gold standard for cardiac output measuring. The correlation coefficients r between the two methods ranged from 0.79 to 0.92. Bias and precision analysis ranged from -0.02 +/- 0.78 l/min/m(2) to -0.14 +/- 0.73 l/min/m(2). Additionally, data on practicality, limitations and clinical impact of the devices were collected. CONCLUSION The accuracy of non-invasive cardiac output monitoring devices in trauma patients is broadly satisfactory. As the devices can be applied very early in the shock room or even preclinically, hemodynamic shock may be recognized much earlier and therapeutic interventions could be applied more rapidly and more adequately. The devices can be used in the daily routine of a busy ED, as they are non-invasive and easy to master.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: There is increasing evidence that a history of childhood abuse and neglect is not uncommon among individuals who experience mental disorder and that childhood trauma experiences are associated with adult psychopathology. Although several interview and self-report instruments for retrospective trauma assessment have been developed, many focus on sexual abuse (SexAb) rather than on multiple types of trauma or adversity. METHODS: Within the European Prediction of Psychosis Study, the Trauma and Distress Scale (TADS) was developed as a new self-report assessment of multiple types of childhood trauma and distressing experiences. The TADS includes 43 items and, following previous measures including the Childhood Trauma Questionnaire, focuses on five core domains: emotional neglect (EmoNeg), emotional abuse (EmoAb), physical neglect (PhyNeg), physical abuse (PhyAb), and SexAb.This study explores the psychometric properties of the TADS (internal consistency and concurrent validity) in 692 participants drawn from the general population who completed a mailed questionnaire, including the TADS, a depression self-report and questions on help-seeking for mental health problems. Inter-method reliability was examined in a random sample of 100 responders who were reassessed in telephone interviews. RESULTS: After minor revisions of PhyNeg and PhyAb, internal consistencies were good for TADS totals and the domain raw score sums. Intra-class coefficients for TADS total score and the five revised core domains were all good to excellent when compared to the interviewed TADS as a gold standard. In the concurrent validity analyses, the total TADS and its all core domains were significantly associated with depression and help-seeking for mental problems as proxy measures for traumatisation. In addition, robust cutoffs for the total TADS and its domains were calculated. CONCLUSIONS: Our results suggest the TADS as a valid, reliable, and clinically useful instrument for assessing retrospectively reported childhood traumatisation.