59 resultados para Mola hidatiforme (MH)


Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS: To determine whether the current practice of sweat testing in Swiss hospitals is consistent with the current international guidelines. METHODS: A questionnaire was mailed to all children's hospitals (n = 8), regional paediatric sections of general hospitals (n = 28), and all adult pulmonology centres (n = 8) in Switzerland which care for patients with cystic fibrosis (CF). The results were compared with published "guidelines 2000" of the American National Committee for Clinical Laboratory Standards (NCCLS) and the UK guidelines of 2003. RESULTS: The response rate was 89%. All 8 children's hospitals and 18 out of 23 answering paediatric sections performed sweat tests but none of the adult pulmonology centres. In total, 1560 sweat tests (range: 5-200 tests/centre/year, median 40) per year were done. 88% (23/26) were using Wescor systems, 73% (19/26) the Macroduct system for collecting sweat and 31% (8/26) the Nanoduct system. Sweat chloride was determined by only 62% (16/26) of all centres; of these, only 63% (10/16) indicated to use the recommended diagnostic chloride-CF-reference value of >60 mmol/l. Osmolality was measured in 35%, sodium in 42% and conductivity in 62% of the hospitals. Sweat was collected for maximal 30-120 (median 55) minutes; only three centres used the maximal 30 minutes sample time recommended by the international guidelines. CONCLUSIONS: Sweat testing practice in Swiss hospitals was inconsistent and seldom followed the current international guidelines for sweat collection, analyzing method and reference values. Only 62% were used the chloride concentration as a diagnostic reference, the only accepted diagnostic measurement by the NCCLS or UK guidelines.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Zymosan-induced peritonitis is associated with an increased production of reactive nitrogen oxides that may contribute to the often-observed failure of multiple organ systems in this model of acute inflammation. Quantitative biochemical evidence is provided for a marked 13-fold increase in protein-bound 3-nitrotyrosine (NTyr), a biomarker of reactive nitrogen oxides, in liver tissue of zymosan-treated rats. In order to investigate the localization of NTyr in this affected tissue, a monoclonal antibody, designated 39B6, was raised against 3-(4-hydroxy-3-nitrophenylacetamido) propionic acid-bovine serum albumin conjugate and its performance characterized. 39B6 was judged by competition ELISA to be approximately 2 orders of magnitude more sensitive than a commercial anti-NTyr monoclonal antibody. Binding characteristics of 39B6 were similar, but not identical, to that of a commercial affinity-purified polyclonal antibody in ELISA and immunohistochemical analyses. Western blot experiments revealed high specificity of 39B6 against NTyr and increased immunoreactivity of specific proteins from liver tissue homogenates of zymosan-treated rats. Immunohistochemical analysis of liver sections indicated a marked zymosan-induced increase in immunofluorescent staining, which was particularly intense in or adjacent to nonparenchymal cells, but not in the parenchymal cells of this tissue. Quantitative analysis of fractions enriched in these cell populations corroborated the immunofluorescent data, although the relative amounts detected in response to zymosan treatment was greatly reduced compared to whole liver tissue. These results demonstrate the high specificity of the newly developed antibody and its usefulness in Western blot and immunohistochemical analysis for NTyr, confirm the presence of NTyr by complementary methods, and suggest the possible involvement of reactive nitrogen oxides in hepatic vascular dysfunction.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador: