67 resultados para Mechanistic Investigations


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reflected at any level of organization of the central nervous system, most of the processes ranging from ion channels to neuronal networks occur in a closed loop, where the input to the system depends on its output. In contrast, most in vitro preparations and experimental protocols operate autonomously, and do not depend on the output of the studied system. Thanks to the progress in digital signal processing and real-time computing, it is now possible to artificially close the loop and investigate biophysical processes and mechanisms under increased realism. In this contribution, we review some of the most relevant examples of a new trend in in vitro electrophysiology, ranging from the use of dynamic-clamp to multi-electrode distributed feedback stimulation. We are convinced these represents the beginning of new frontiers for the in vitro investigation of the brain, promising to open the still existing borders between theoretical and experimental approaches while taking advantage of cutting edge technologies.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Percutaneous vertebroplasty, comprising an injection of polymethylmethacrylate (PMMA) into vertebral bodies, is a practical procedure for the stabilization of osteoporotic compression fractures as well as other weakening lesions. Cement leakage is considered to be one of the major and most severe complications during percutaneous vertebroplasty. The viscosity of the material plays a key role in this context. In order to enhance the safety for the patient, a rheometer system was developed to measure the cement viscosity intraoperatively. For this development, it is of great importance to know the proper viscosity to start the procedure determined by experienced surgeons and the relation between the time period when different injection devices are used and the cement viscosity. The purpose of the study was to investigate the viscosity ranges for different injection systems during conventional vertebroplasty. Clinically observed viscosity values and related time periods showed high scattering. In order to get a better understanding of the clinical observations, cement viscosity during hardening at different ambient temperatures and by simulation of the body temperature was investigated in vitro. It could be concluded, that the direct viscosity assessment with a rheometer during vertebroplasty can help clinicians to define a lower threshold viscosity and thereby decrease the risk of leakage and make adjustments to their injection technique in real time. Secondly, the acceleration in hardening of PMMA-based cements at body temperature can be useful in minimizing leakages by addressing them with a short injection break.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Like tumor metastases, endometriotic implants require neovascularization to proliferate and invade into ectopic sites within the host. Endometrial tissue, with its robust stem cell populations and remarkable regenerative capabilities, is a rich source of proangiogenic factors. Among the most potent and extensively studied of these proteins, vascular endothelial growth factor has emerged as a critical vasculogenic regulator in endometriosis. Accordingly, angiogenesis of the nascent endometriotic lesion has become an attractive target for novel medical therapeutics and strategies to inhibit vascular endothelial growth factor action. Vascular endothelial growth factor gene regulation in endometrial and endometriosis cells by nuclear receptors, other transcription factors, and also by infiltrating immune cells is emphasized. New data showing that oxidative and endoplasmic reticulum stress increase vascular endothelial growth factor expression are provided. Finally, we review the clinical implications of angiogenesis in this condition and propose potential antiangiogenic therapies that may become useful in the control or eradication of endometriotic lesions.