58 resultados para Mandibular apparatus
Resumo:
In this paper we present a new population-based implant design methodology, which advances the state-of-the-art approaches by combining shape and bone quality information into the design strategy. The method enhances the mechanical stability of the fixation and reduces the intra-operative in-plane bending which might impede the functionality of the locking mechanism. The method is presented for the case of mandibular locking fixation plates, where the mandibular angle and the bone quality at screw locations are taken into account. Using computational anatomy techniques, the method automatically derives, from a set of computed tomography images, the mandibular angle and the bone thickness and intensity values at the path of every screw. An optimisation strategy is then used to optimise the two parameters of plate angle and screw position. Results for the new design are presented along with a comparison with a commercially available mandibular locking fixation plate. A statistically highly significant improvement was observed. Our experiments allowed us to conclude that an angle of 126° and a screw separation of 8mm is a more suitable design than the standard 120° and 9mm.
Resumo:
OBJECTIVE: To report use of a pinless external fixator (PEF) for unilateral mandibular fractures in 9 equids. STUDY DESIGN: Case series. ANIMALS: Equids (n=9) with unilateral mandibular fractures. METHODS: All fractures were stabilized with the AO/ASIF PEF using a minimum of 4 clamps, under general anesthesia. Fracture configuration, complications, outcome, and owner satisfaction were evaluated. RESULTS: All fractures were stabilized; 2 equids were euthanatized; 1 because of an inability to stand after surgery and 1 because of owner decision after PEF dislodgement. Seven repairs healed with good outcome and owner satisfaction. Complications included dislodgement of the PEF (3), bone sequestration (3), and weight loss (1). Drainage associated with repair resolved after removal of sequestra and clamps. CONCLUSIONS: Stabilization of unilateral mandibular fractures with the PEF in horses was minimally invasive with minimal risk of tooth root interference; however, after care is time consuming. CLINICAL RELEVANCE: PEF is an alternative technique for stabilizing unilateral mandibular fractures in equids.
Resumo:
In this paper we present a new population-based implant design methodology, which advances the state-of-the-art approaches by combining shape and bone quality information into the design strategy. The method may enhance the mechanical stability of the fixation and reduces the intra-operative in-plane bending which might impede the functionality of the locking mechanism. The computational method is presented for the case of mandibular locking fixation plates, where the mandibular angle and the bone quality at screw locations are taken into account. The method automatically derives the mandibular angle and the bone thickness and intensity values at the path of every screw from a set of computed tomography images. An optimization strategy is then used to optimize the two parameters of plate angle and screw position. The method was applied to two populations of different genders. Results for the new design are presented along with a comparison with a commercially available mandibular locking fixation plate (MODUS(®) TriLock(®) 2.0/2.3/2.5, Medartis AG, Basel, Switzerland). The proposed designs resulted in a statistically significant improvement in the available bone thickness when compared to the standard plate. There is a higher probability that the proposed implants cover areas of thicker cortical bone without compromising the bone mineral density around the screws. The obtained results allowed us to conclude that an angle and screw separation of 129° and 9 mm for females and 121° and 10 mm for males are more suitable designs than the commercially available 120° and 9 mm.
Resumo:
This study analyzes short- and long-term skeletal relapse after mandibular advancement surgery and determines its contributing factors. Thirty-two consecutive patients were treated for skeletal Class II malocclusion during the period between 1986 and 1989. They all had combined orthodontic and surgical treatment with BSSO and rigid fixation excluding other surgery. Of these, 15 patients (47%) were available for a long-term cephalography in 2000. The measurement was performed based on the serial cephalograms taken preoperatively; 1 week, 6 months and 14 months postoperatively; and at the final evaluation after an average of 12 years. Mean mandibular advancement was 4.1 mm at B-point and 4.9 mm at pogonion. Representing surgical mandibular ramus displacement, gonion moved downwards 2 mm immediately after surgery. During the short-term postoperative period, mandibular corpus length decreased only 0.5 mm, indicating that there was no osteotomy slippage. After the first year of observation, skeletal relapse was 1.3 mm at B-point and pogonion. The relapse continued, reaching a total of 2.3 mm after 12 years, corresponding to 50% of the mandibular advancement. Mandibular ramus length continuously decreased 1 mm during the same observation period, indicating progressive condylar resorption. No significant relationship between the amount of initial surgical advancement and skeletal relapse was found. Preoperative high mandibulo-nasal plane (ML-NL) angle appears to be associated with long-term skeletal relapse.
Resumo:
Nail surgery is an integral part of dermatologic surgery. An in-depth knowledge of the anatomy, biology, physiology, and gross pathology of the entire nail unit is essential. In particular, knowledge of nail histopathology is necessary to perform diagnostic nail biopsies and other nail procedures correctly.
Resumo:
BACKGROUND: The aim of this study was to evaluate the efficacy of a combination graft, using recombinant human bone morphogenetic protein-2 (rhBMP-2) and culture-expanded cells derived from bone marrow, for bone regeneration in a nonhuman primate mandible. METHODS: Five Japanese monkeys were used. Three milliliters of bone marrow was obtained from the tibia and plated into culture flasks. Adherent cells were cultured until near confluence; then, the proliferated cells were transferred to a three-dimensional culture system using collagen beads as the cell carrier. The medium was supplemented with ascorbic acid, beta-glycerophosphate, and dexamethasone to promote osteoblastic differentiation. After further proliferation on beads, the cells were mixed with a collagen sponge that was impregnated with rhBMP-2 and grafted into surgically created segmental bone defects of the mandibles. Three animals received this treatment, and either culture-expanded cells alone or collagen beads without cells were implanted into the remaining two monkeys as controls. The animals were killed 24 weeks after surgery, and the results were assessed by radiographic and histologic evaluation. RESULTS: The combination graft of culture-expanded bone marrow cells with rhBMP-2 in a collagen sponge regenerated the mandibular bone completely. By contrast, the graft of culture-expanded cells alone resulted in only a small amount of bone formation, and the implantation of collagen beads alone led to no bone formation. CONCLUSION: The combination graft of rhBMP-2 and culture-expanded cells, which requires only a small amount of bone marrow, is a reliable method for the reconstruction of segmental bone defects of the mandible.
Resumo:
PURPOSE: To evaluate the pulp sensitivity and vitality of mandibular incisors and canines before and after bone harvesting in the symphysis. MATERIALS AND METHODS: In 20 patients requiring bone grafts from the symphysis, pulp sensitivity (carbon dioxide [CO2]) and pulpal blood flow (laser Doppler flowmetry [LDF]) of mandibular incisors and canines were evaluated preoperatively, postoperatively, and 6 months after surgery. Teeth were allocated to 1 of 3 groups according to their initial and final reaction to CO2 (group A = teeth with a positive reaction throughout the study, group B = teeth that exhibited a sensitivity change from positive to negative, and group C = teeth with a negative reaction throughout the study). RESULTS: Preoperative flux measurements (LDF) did not differ between groups A, B, and C. Teeth with sensitivity changes (group B) showed the greatest decrease (a statistically significant decrease) of pulpal blood flow over time, whereas teeth in groups A and C demonstrated an insignificant reduction of flux over time. DISCUSSION AND CONCLUSIONS: LDF was purely used as an experimental tool in the present study. Pulpal blood flow measurements using LDF demonstrated a decrease of flux over time in anterior mandibular teeth following bone harvesting in the symphysis. A significant change of flux, however, was only observed for teeth that also demonstrated a loss of pulp sensitivity during the same study period. Loss of pulp sensitivity appeared to be correlated to a significant decrease of blood flow assessed by LDF.
Resumo:
A Lhassa Apso is presented in emergency after having been injured by another dog. It was suffering from a mandibular fracture. The clinical exam revealed generalized and excessive mobility of the whole dentition. Radiographs showed generalized jaw bone demineralisation. A blood sample was analysed and revealed chronic renal disease. We came to the conclusion that this dog was suffering from secondary renal hyperparathyroidism. The hypocalcified bone was so thin that a slight trauma induced the mandibular fracture.
Resumo:
PURPOSE: The aim of this follow-up study was to evaluate the clinical usefulness of a new type of 3-dimensional (3D) miniplate for open reduction and monocortical fixation of mandibular angle fractures. PATIENTS AND METHODS: In 20 consecutive patients, noncomminuted mandibular angle fractures were treated with open reduction and fixation using a 2 mm 3D miniplate system in a transoral approach. All patients were systematically monitored until 6 months postoperatively. Among the outcome parameters recorded were infection, hardware failure, wound dehiscence, and sensory disturbance of the inferior alveolar nerve. RESULTS: The mean operation time from incision to wound closure was 65 minutes. Two patients had a mucosal wound dehiscence with no consequences. None developed an infection requiring a plate removal. All but 2 patients had normal sensory function 3 months after surgery. Plate fracture occurred in one patient in whom a preceding surgical removal of the third molar had been the reason for the mandibular fracture. In the absence of clinical symptoms, the patient declined plate removal. On final follow-up, fracture healing was considered clinically complete in all patients. CONCLUSIONS: The 3D plating system described here is suitable for fixation of simple mandibular angle fractures and is an easy-to-use alternative to conventional miniplates. The system may be contraindicated in patients in whom insufficient interfragmentary bone contact causes minor stability of the fracture.
Resumo:
PURPOSE: The aim of this study was to assess long-term changes in position of soft tissue landmarks following mandibular advancement and setback surgery. MATERIALS AND METHODS: Twenty-seven patients (14 women, 13 men; mean age, 36 years) who had undergone either mandibular advancement (15 patients) or setback surgery (12 patients), were available for a long-term follow-up an average of 12 years postoperatively. In all of these cases, lateral cephalometric radiographs taken immediately before operation, at 1 week, 14 months, and 12 years postoperatively, were studied. RESULTS: During the 14 months postoperatively, soft tissue chin and mentolabial fold followed its underlying hard tissue in all patients. A continuous skeletal relapse was observable 12 years after mandibular advancement, but soft tissue chin moved more in an anterior direction. After mandibular setback, soft and hard tissue landmarks remained almost unchanged. Over the entire observation period, a thickening of soft tissue at pogonion was generally seen, and particularly a thickening of the whole chin in the setback group. All patients showed a significant lengthening and thinning of the upper lip. In all except 2 males, the patient's body weight increased markedly. CONCLUSION: In contrast to the immediate postoperative stage, soft tissue changes observed an average of 12 years after the primary operation do not directly follow the movements of the underlying skeletal structure. The soft tissue profile changes observed over such a long term seem to be influenced not only by the underlying skeletal structure but also by other factors such as weight gain and aging process.
Resumo:
The estimation of possible intra- and postoperative complications for surgical removal of third molars in the mandible poses a frequent dilemma in oral surgery. In the present study, the influence of the patient's age and gender, a reduced mouth opening, and the anatomical position of the tooth in the mandible on intra- and postoperative complications were evaluated. In a total of 120 surgically removed third molars, 9.2% intraoperative complications occurred, mainly bleeding. Factors influencing the risk for intraoperative complications were a male patient, a reduced mouth opening, and distally angulated teeth. Postoperative complications were encountered in 6.7%, mainly dry sockets. For this group, a female gender, a higher age, and distally angulated teeth were identified as risk parameters. As most of the patient- and anatomy-related factors are set parameters when evaluating possible risk factors for third molar surgery, only the timepoint of surgery can be influenced by the surgeon. Regarding the increase in intra- and postoperative complications for third molar removal in higher age groups, the prophylactic third molar surgery between the age of 18 and 25 seems justified.
Resumo:
Mechanical testing of the periodontal ligament requires a practical experimental model. Bovine teeth are advantageous in terms of size and availability, but information is lacking as to the anatomy and histology of their periodontium. The aim of this study, therefore, was to characterize the anatomy and histology of the attachment apparatus in fully erupted bovine mandibular first molars. A total of 13 teeth were processed for the production of undecalcified ground sections and decalcified semi-thin sections, for NaOH maceration, and for polarized light microscopy. Histomorphometric measurements relevant to the mechanical behavior of the periodontal ligament included width, number, size and area fraction of blood vessels and fractal analysis of the two hard-soft tissue interfaces. The histological and histomorphometric analyses were performed at four different root depths and at six circumferential locations around the distal and mesial roots. The variety of techniques applied provided a comprehensive view of the tissue architecture of the bovine periodontal ligament. Marked regional variations were observed in width, surface geometry of the two bordering hard tissues (cementum and alveolar bone), structural organization of the principal periodontal ligament connective tissue fibers, size, number and numerical density of blood vessels in the periodontal ligament. No predictable pattern was observed, except for a statistically significant increase in the area fraction of blood vessels from apical to coronal. The periodontal ligament width was up to three times wider in bovine teeth than in human teeth. The fractal analyses were in agreement with the histological observations showing frequent signs of remodeling activity in the alveolar bone - a finding which may be related to the magnitude and direction of occlusal forces in ruminants. Although samples from the apical root portion are not suitable for biomechanical testing, all other levels in the buccal and lingual aspects of the mesial and distal roots may be considered. The bucco-mesial aspect of the distal root appears to be the most suitable location.