Coronary aneurysm formation after drug-eluting stent (DES) implantation is a rare complication with late stent thrombosis as a potentially fatal sequela. One possible mechanism involved in aneurysm formation is thought to be late-acquired stent malapposition due to a local inflammatory response to the polymer and/or the drug. Coronary aneurysm formation has been documented with sirolimus- and paclitaxel-eluting stents. We report a case of coronary aneurysm formation in a patient with an everolimus-eluting stent (EES; Xience(R) Abbott Vascular, Redwood City, California) relatively early (3 months) after stent implantation. This case illustrates that even with second-generation DES like the EES, which is thought to be highly biocompatible, there can be adverse reactions to the polymer and/or to the drug.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Vascular healing of intracoronary stents has been shown to be delayed in drug-eluting stents (DES) due to the cytotoxic compounds on the stent surface that prevent stent ingrowth and endothelialization. The lack of endothelialization explains the occurrence of late and very late stent thrombosis in DES. MATERIALS AND METHODS: In 11 house swines (body weight 38-45 kg), 3 stents were implanted randomly into the 3 large epicardial coronary arteries, namely a bare-metal stent (BMS), a sirolimus-eluting stent with slow-release (SES) and a SES with extended-release (SESXR). Stent length was 18 mm, and stent diameter 3 mm. All stents were of identical design. Animals were followed for 3 (n = 3), 7 (n = 4) and 14 (n = 4) days, respectively. One animal died before implantation due to hyperthermia. On the day of explantation, the animals were euthanized and endothelialization was tested by scanning electron microscopy after drying and sputtering the samples. Endothelial coverage was determined semiquantitatively by 2 observers. RESULTS: Endothelialization was more rapid with BMS and SESXR than SES at 3 and 14 days. At 7 days there were no significant differences between the 2 SES. CONCLUSIONS: Endothelialization of intracoronary stents is faster with BMS and SESXR at 3 days than with SES. These differences persist at 14 days, suggesting delayed vascular healing with the slow-release SES.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Polymer as carrier substance for drugeluting stents (DES) has been accused of inducing inflammation and hypersensitivity reactions leading to restenosis and stent thrombosis. Thus, a new paclitaxel-eluting stent (PES) with aminoparylene as a carrier substance is tested in the present study. METHODS: In 10 pigs, stents were implanted in the epicardial coronary arteries: 1) bare-metal stents (BMS, control stent); 2) cobalt-chromium stents (CCS); and 3) PES. Stent length was 15 mm, and diameter was 3 mm. The animals were restudied after 6 weeks. Quantitative coronary angiography was performed at baseline and follow up. Minimum luminal diameter (MLD) and late loss were calculated in all animals. Histologic vessel lumen, intimal proliferation and restenosis were determined by morphometry. Disruption of the lamina elastica interna (LEI) and inflammatory reactions were assessed by histology. RESULTS: The MLD at baseline was 2.83 +/- 0.28 mm, and at follow up it was 2.29 +/- 0.44 (p < 0.05; n = 30). Late loss and angiographic restenosis were smallest in the CCS and largest in the PES (ns). Neointimal proliferation was similar for all 3 stents, ranging between 1.38 and 1.64 mm(2) (ns). There was a significant correlation between disruption of the LEI and inflammatory reactions. CONCLUSIONS: PTs with aminoparylene as a carrier substance show similar late loss and angiographic restenosis to that of BM and CCS. The incidence of inflammatory reactions (35% of all histologic sections) is similar in all stents, but highest in PES. The mechanism of this reaction is unclear, but may be either due to the drug itself, the disruption of the LEI or to a hypersensitivity reaction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present the case of a patient who presented with acute inferior myocardial infarction and embolic occlusion of the distal left anterior descending and proximal right coronary artery. A large atrial septal defect (ASD) was seen on transesophageal echocardiography and the ASD was closed during the same session as coronary angiography and percutaneous coronary intervention. The presence of embolic or thrombotic occlusions of coronary arteries should prompt interventional cardiologists to look for a patent foramen ovale or ASD and perform percutaneous closure right away.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We used intravascular ultrasound (IVUS) and virtual histology (VH) to assess the differences of plaque burden and composition between target coronary arteries containing the culprit lesion and non-target coronary arteries.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We compared continuous pullback from the left anterior descending artery (LAD) with pullback from the circumflex artery (CX) for the assessment of the left main coronary artery (LMCA) by intravascular ultrasound (IVUS).