83 resultados para Low threshold current densities


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Serotonin (5-hydroxytryptamine, 5-HT) is involved in gastrointestinal tract (GIT) motor functions through binding to specific receptors located in the GIT walls. The objectives of the current study were to compare mRNA levels and binding sites of 5-HT(4) receptors (5-HTR(4)) in smooth muscle layers from the fundus abomasi, pylorus, ileum, cecum, proximal loop of the ascending colon (PLAC), and external loop of the spiral colon (ELSC) of healthy dairy cows, and to verify whether mRNA and protein expression were correlated. Smooth muscle samples were prepared by scraping the mucosa and submucosa from full-thickness intestinal wall samples. The mRNA levels of 5-HTR(4) were measured by real-time PCR and expressed relative to those of the housekeeping gene glyceraldehyde phosphate dehydrogenase. Binding studies were performed using the 5-HTR(4) antagonist [(3)H]GR113808. The mRNA levels of 5-HTR(4) were affected (P < 0.05) by location along the GIT. The mRNA levels of 5-HTR(4) in the ELSC and the ileum were greater than in the PLAC (P = 0.05 and P = 0.07, respectively) but similar to those of all other locations. The competitive binding of [(3)H]GR113808 to suspended membranes from the fundus abomasi, pylorus, cecum, and ELSC was best fit by a 2-site receptor model, whereas it was best fit by a 1-site receptor model in the ileum and PLAC. The mRNA levels and numbers of 5-HTR(4) were not correlated (r = 0.14; P = 0.71). In conclusion, mRNA and binding sites for 5-HTR(4) are present in the smooth muscle layer of the entire GIT of dairy cows and may play a role with respect to motility. The effects of activation of this receptor subtype may be different among GIT locations due to differences in the amount of high- relative to low-affinity binding sites.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

PURPOSE: To prospectively evaluate, for the depiction of simulated hypervascular liver lesions in a phantom, the effect of a low tube voltage, high tube current computed tomographic (CT) technique on image noise, contrast-to-noise ratio (CNR), lesion conspicuity, and radiation dose. MATERIALS AND METHODS: A custom liver phantom containing 16 cylindric cavities (four cavities each of 3, 5, 8, and 15 mm in diameter) filled with various iodinated solutions to simulate hypervascular liver lesions was scanned with a 64-section multi-detector row CT scanner at 140, 120, 100, and 80 kVp, with corresponding tube current-time product settings at 225, 275, 420, and 675 mAs, respectively. The CNRs for six simulated lesions filled with different iodinated solutions were calculated. A figure of merit (FOM) for each lesion was computed as the ratio of CNR2 to effective dose (ED). Three radiologists independently graded the conspicuity of 16 simulated lesions. An anthropomorphic phantom was scanned to evaluate the ED. Statistical analysis included one-way analysis of variance. RESULTS: Image noise increased by 45% with the 80-kVp protocol compared with the 140-kVp protocol (P < .001). However, the lowest ED and the highest CNR were achieved with the 80-kVp protocol. The FOM results indicated that at a constant ED, a reduction of tube voltage from 140 to 120, 100, and 80 kVp increased the CNR by factors of at least 1.6, 2.4, and 3.6, respectively (P < .001). At a constant CNR, corresponding reductions in ED were by a factor of 2.5, 5.5, and 12.7, respectively (P < .001). The highest lesion conspicuity was achieved with the 80-kVp protocol. CONCLUSION: The CNR of simulated hypervascular liver lesions can be substantially increased and the radiation dose reduced by using an 80-kVp, high tube current CT technique.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: The aim of this study was to evaluate the effect of CD4+ T-cell counts and other characteristics of HIV-infected individuals on hepatitis C virus (HCV) RNA levels. METHODS: All HIV-HCV-coinfected Swiss HIV Cohort Study participants with available HCV RNA levels and concurrent CD4+ T-cell counts before starting HCV therapy were included. Potential predictors of HCV RNA levels were assessed by multivariate censored linear regression models that adjust for censored values. RESULTS: The study included 1,031 individuals. Low current and nadir CD4+ T-cell counts were significantly associated with higher HCV RNA levels (P = 0.004 and 0.001, respectively). In individuals with current CD4+ T-cell counts < 200/microl, median HCV RNA levels (6.22 log10 IU/ml) were +0.14 and +0.24 log10 IU/ml higher than those with CD4+ T-cell counts of 200-500/microl and > 500/microl. Based on nadir CD4+ T-cell counts, median HCV RNA levels (6.12 log10 IU/ml) in individuals with < 200/microl CD4+ T-cells were +0.06 and +0.44 log10 IU/ml higher than those with nadir T-cell counts of 200-500/microl and > 500/microl. Median HCV RNA levels were also significantly associated with HCV genotype: lower values were associated with genotype 4 and higher values with genotype 2, as compared with genotype 1. Additional significant predictors of lower HCV RNA levels were female gender and HIV transmission through male homosexual contacts. In multivariate analyses, only CD4+ T-cell counts and HCV genotype remained significant predictors of HCV RNA levels. Conclusions: Higher HCV RNA levels were associated with CD4+ T-cell depletion. This finding is in line with the crucial role of CD4+ T-cells in the control of HCV infection.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: To evaluate the effect of automatic tube current modulation on radiation dose and image quality for low tube voltage computed tomography (CT) angiography. MATERIALS AND METHODS: An anthropomorphic phantom was scanned with a 64-section CT scanner using following tube voltages: 140 kVp (Protocol A), 120 kVp (Protocol B), 100 kVp (Protocol C), and 80 kVp (Protocol D). To achieve similar noise, combined z-axis and xy-axes automatic tube current modulation was applied. Effective dose (ED) for the four tube voltages was assessed. Three plastic vials filled with different concentrations of iodinated solution were placed on the phantom's abdomen to obtain attenuation measurements. The signal-to-noise ratio (SNR) was calculated and a figure of merit (FOM) for each iodinated solution was computed as SNR(2)/ED. RESULTS: The ED was kept similar for the four different tube voltages: (A) 5.4 mSv +/- 0.3, (B) 4.1 mSv +/- 0.6, (C) 3.9 mSv +/- 0.5, and (D) 4.2 mSv +/- 0.3 (P > .05). As the tube voltage decreased from 140 to 80 kVp, image noise was maintained (range, 13.8-14.9 HU) (P > .05). SNR increased as the tube voltage decreased, with an overall gain of 119% for the 80-kVp compared to the 140-kVp protocol (P < .05). The FOM results indicated that with a reduction of the tube voltage from 140 to 120, 100, and 80 kVp, at constant SNR, ED was reduced by a factor of 2.1, 3.3, and 5.1, respectively, (P < .001). CONCLUSIONS: As tube voltage decreases, automatic tube current modulation for CT angiography yields either a significant increase in image quality at constant radiation dose or a significant decrease in radiation dose at a constant image quality.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Short range nucleon-nucleon correlations in nuclei (NN SRC) carry important information on nuclear structure and dynamics. NN SRC have been extensively probed through two-nucleon knock- out reactions in both pion and electron scattering experiments. We report here on the detection of two-nucleon knock-out events from neutrino interactions and discuss their topological features as possibly involving NN SRC content in the target argon nuclei. The ArgoNeuT detector in the Main Injector neutrino beam at Fermilab has recorded a sample of 30 fully reconstructed charged current events where the leading muon is accompanied by a pair of protons at the interaction vertex, 19 of which have both protons above the Fermi momentum of the Ar nucleus. Out of these 19 events, four are found with the two protons in a strictly back-to-back high momenta configuration directly observed in the final state and can be associated to nucleon Resonance pionless mechanisms involving a pre-existing short range correlated np pair in the nucleus. Another fraction (four events) of the remaining 15 events have a reconstructed back-to-back configuration of a np pair in the initial state, a signature compatible with one-body Quasi Elastic interaction on a neutron in a SRC pair. The detection of these two subsamples of the collected (mu- + 2p) events suggests that mechanisms directly involving nucleon-nucleon SRC pairs in the nucleus are active and can be efficiently explored in neutrino-argon interactions with the LAr TPC technology.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A medical cyclotron accelerating H- ions to 18 MeV is in operation at the Bern University Hospital (Inselspital). It is the commercial IBA 18/18 cyclotron equipped with a specifically conceived 6 m long external beam line ending in a separate bunker. This feature is unique for a hospital-based facility and makes it possible to conduct routine radioisotope production for PET diagnostics in parallel with multidisciplinary research activities, among which are novel particle detectors, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. Several of these activities, such as radiobiology experiments for example, require low current beams down to the pA range, while medical cyclotrons are designed for high current operation above 10 μA. In this paper, we present the first results on the low current performance of a PET medical cyclotron obtained by ion source, radio-frequency and main coil tuning. With this method, stable beam currents down to (1.5+/- 0.5 ) pA were obtained and measured with a high-sensitivity Faraday cup located at the end of the beam transport line.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recent studies have shown that the nociceptive withdrawal reflex threshold (NWR-T) and the electrical pain threshold (EP-T) are reliable measures in pain-free populations. However, it is necessary to investigate the reliability of these measures in patients with chronic pain in order to translate these techniques from laboratory to clinic. The aims of this study were to determine the test-retest reliability of the NWR-T and EP-T after single and repeated (temporal summation) electrical stimulation in a group of patients with chronic low back pain, and to investigate the association between the NWR-T and the EP-T. To this end, 25 patients with chronic pain participated in three identical sessions, separated by 1 week in average, in which the NWR-T and the EP-T to single and repeated stimulation were measured. Test-retest reliability was assessed using intra-class correlation coefficient (ICC), coefficient of variation (CV), and Bland-Altman analysis. The association between the thresholds was assessed using the coefficient of determination (r (2)). The results showed good-to-excellent reliability for both NWR-T and EP-T in all cases, with average ICC values ranging 0.76-0.90 and average CV values ranging 12.0-17.7%. The association between thresholds was better after repeated stimulation than after single stimulation, with average r (2) values of 0.83 and 0.56, respectively. In conclusion, the NWR-T and the EP-T are reliable assessment tools for assessing the sensitivity of spinal nociceptive pathways in patients with chronic pain.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Refinement in microvascular reconstructive techniques over the last 30 years has enabled an increasing number of patients to be rehabilitated for both functional and aesthetic reasons. The purpose of this study was to evaluate different microsurgical practice, including perioperative management, in Germany, Austria, and Switzerland. The DÖSAK collaborative group for Microsurgical Reconstruction developed a detailed questionnaire which was circulated to units in the three countries. The current practice of the departments was evaluated. Thirty-eight questionnaires were completed resulting in a 47.5% response rate. A considerable variation in the number of microsurgical reconstructions per year was noted. In relation to the timing of bony reconstruction, 10 hospitals did reconstructions primarily (26.3%), 19 secondarily (50%) and 9 (23.7%) hospitals used both concepts. In the postoperative course, 15.8% of hospitals use inhibitors of platelet aggregation, most hospitals use low molecular heparin (52.6%) or other heparin products (44.7%). This survey shows variation in the performance, management, and care of microsurgical reconstructions of patients. This is due in part to the microvascular surgeons available in the unit but it is also due to different types of hospitals where various types of care can be performed in these patients needing special perioperative care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This review summarizes current evidence based on pertinent literature on low-dose computed tomography angiography (CTA) of the body. Various strategies for optimizing CTA protocols with the aim to lower the radiation dose while maintaining the diagnostic accuracy of the examination are summarized. To date, various publications have demonstrated that CTA of the body can be performed at a low radiation dose while providing high quality information. Nevertheless, a number of questions still need to be answered, including the optimal combination of tube voltage and tube current settings, as well as the appropriate protocol parameters in relation to the body physiognomy and the specific body region imaged.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The "Trond" protocol of nerve excitability tests has been used widely to assess axonal function in peripheral nerve. In this study, the routine Trond protocol was expanded to refine assessment of cAMP-dependent, hyperpolarization-activated current (I(h)) activity. I(h) activity is generated by hyperpolarization-activated, cyclic nucleotide-modulated (HCN) channels in response to hyperpolarization. It limits activity-dependent hyperpolarization, contributes to neuronal automaticity, and is implicated in chronic pain states. Published data regarding I(h) activity in motor nerve are scant. We used additional strong, prolonged hyperpolarizing conditioning stimuli in the threshold electrotonus component of the Trond protocol to demonstrate the time-course of activation of I(h) in motor axons. Fifteen healthy volunteers were tested on four occasions during 1 week. I(h) action was revealed in the threshold electrotonus by the limiting and often reversal, after about 100 ms, of the threshold increase caused by strong hyperpolarizing currents. Statistical analysis by repeated-measures analysis of variance enabled confidence limits to be established for variation between subjects and within subjects. The results demonstrate that, of all the excitability parameters, those dependent on I(h) were the most characteristic of an individual, because variance between subjects was more than four times the variance within subjects. This study demonstrates a reliable method for in vivo assessment of I(h,) and also serves to document the normal variability in nerve excitability properties within subjects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The clinical validity of at-risk criteria of psychosis had been questioned based on epidemiological studies that have reported much higher prevalence and annual incidence rates of psychotic-like experiences (PLEs as assessed by either self rating questionnaires or layperson interviews) in the general population than of the clinical phenotype of psychotic disorders (van Os et al., 2009). Thus, it is unclear whether “current at-risk criteria reflect behaviors so common among adolescents and young adults that a valid distinction between ill and non-ill persons is difficult” (Carpenter, 2009). We therefore assessed the 3-month prevalence of at-risk criteria by means of telephone interviews in a randomly drawn general population sample from the at-risk age segment (age 16–35 years) in the Canton Bern, Switzerland. Eighty-five of 102 subjects had valid phone numbers, 21 of these subjects refused (although 6 of them signaled willingness to participate at a later time), 4 could not be contacted. Sixty subjects (71% of the enrollment fraction) participated. Two participants met exclusion criteria (one for being psychotic, one for lack of language skills). Twenty-two at-risk symptoms were assessed for their prevalence and severity within the 3 months prior to the interview by trained clinical raters using (i) the Structured Interview for Prodromal Syndromes (SIPS; Miller et al., 2002) for the evaluation of 5 attenuated psychotic and 3 brief limited intermittent psychotic symptoms (APS, BLIPS) as well as state-trait criteria of the ultra-high-risk (UHR) criteria and (ii) the Schizophrenia Proneness Instrument, Adult version (SPI-A; Schultze-Lutter et al., 2007) for the evaluation of the 14 basic symptoms included in COPER and COGDIS (Schultze-Lutter et al., 2008). Further, psychiatric axis I diagnoses were assessed by means of the Mini-International Neuropsychiatric Interview, M.I.N.I. (Sheehan et al., 1998), and psychosocial functioning by the Scale of Occupational and Functional Assessment (SOFAS; APA, 1994). All interviewees felt ‘rather’ or ‘very’ comfortable with the interview. Of the 58 included subjects, only 1 (2%) fulfilled APS criteria by reporting the attenuated, non-delusional idea of his mind being literally read by others at a frequency of 2–3 times a week that had newly occurred 6 weeks ago. BLIPS, COPER, COGDIS or state-trait UHR criteria were not reported. Yet, twelve subjects (21%) described sub-threshold at-risk symptoms: 7 (12%) reported APS relevant symptoms but did not meet time/frequency criteria of APS, and 9 (16%) reported COPER and/or COGDIS relevant basic symptoms but at an insufficient frequency or as a trait lacking increase in severity; 4 of these 12 subjects reported both sub-threshold APS and sub-threshold basic symptoms. Table 1 displays type and frequency of the sub-threshold at-risk symptoms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The activation of 5-hydroxytryptamine-3 (5-HT-3) receptors in spinal cord can enhance intrinsic spinal mechanisms of central hypersensitivity, possibly leading to exaggerated pain responses. Clinical studies suggest that 5-HT-3 receptor antagonists may have an analgesic effect. This randomized, double-blind, placebo-controlled crossover study tested the hypothesis that the 5-HT-3 receptor antagonist tropisetron attenuates pain and central hypersensitivity in patients with chronic low back pain. Thirty patients with chronic low back pain, 15 of whom were women (aged 53 ± 14 years) and 15 men (aged 48 ± 14 years), were studied. A single intravenous injection of 0.9% saline solution, tropisetron 2mg, and tropisetron 5mg was administrated in 3 different sessions, in a double-blind crossover manner. The main outcome was the visual analogue scale (VAS) score of spontaneous low back pain before, and 15, 30, 60, and 90 minutes after drug administration. Secondary outcomes were nociceptive withdrawal reflexes to single and repeated electrical stimulation, area of reflex receptive fields, pressure pain detection and tolerance thresholds, conditioned pain modulation, and area of clinical pain. The data were analyzed by analysis of variance and panel multiple regressions. All 3 treatments reduced VAS scores. However, there was no statistically significant difference between tropisetron and placebo in VAS scores. Compared to placebo, tropisetron produced a statistically significant increase in pain threshold after single electrical stimulation, but no difference in all other secondary outcomes was found. A single-dose intravenous administration of tropisetron in patients with chronic low back pain had no significant specific effect on intensity of pain and most parameters of central hypersensitivity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cardiovascular disease (CVD) is a major cause of morbidity and mortality worldwide. Epidemiologic research of the last half-century has clearly shown that psychosocial factors related to the social environment, personality characteristics, and negative affect increase the risk of incident CVD and also impact prognosis of cardiac patients. Several mechanisms may explain this link, including a genetic predisposition, poor lifestyle choices, low adherence to health recommendations, and direct pathophysiologic perturbations. The latter include alteration of the hypothalamic-pituitary adrenal axis and autonomic dysfunction resulting in endothelial dysfunction, inflammation, and a prothrombotic state further downstream. Screening for psychosocial factors seems appropriate as part of the standard history and based on the clinician's knowledge of the patient and the purpose of the visit. Psychological interventions generally alleviate distress in cardiac patients, but whether they reduce the risk of hard cardiovascular endpoints and all-cause mortality is less evident. Cardiac patients with more severe depression may particularly profit from antidepressant medications. Due to their pharmacologic properties, selective serotonin reuptake inhibitors were shown to improve cardiovascular outcome. The most effective psychosocial treatment is multicomponent therapy that combines elements of cognitive behaviour therapy ("stress management") and changes in health behaviours, including the adoption of a regular exercise regimen. Gender-specific issues should probably be considered. The field of behavioural cardiology has accumulated a wealth of epidemiological, mechanistic and clinical knowledge that undoubtedly has furthered our understanding about the important role of psychosocial risk factors in patients with a heart disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES:: Widespread central hypersensitivity and altered conditioned pain modulation (CPM) have been documented in chronic pain conditions. Information on their prognostic values is limited. This study tested the hypothesis that widespread central hypersensitivity (WCH) and altered CPM, assessed during the chronic phase of low back and neck pain, predict poor outcome. METHODS:: A total of 169 consecutive patients with chronic low back or neck pain, referred to the pain clinic during 1 year, were analyzed. Pressure pain tolerance threshold at the second toe and tolerance time during cold pressor test at the hand assessed WCH. CPM was measured by the change in pressure pain tolerance threshold (test stimulus) after cold pressor test (conditioning stimulus). A structured telephone interview was performed 12 to 15 months after testing to record outcome parameters. Linear regression models were used, with average and maximum pain intensity of the last 24 hours at follow-up as endpoints. Multivariable analyses included sex, age, catastrophizing scale, Beck Depression Inventory, pain duration, intake of opioids, and type of pain syndrome. RESULTS:: Statistically significant reductions from baseline to follow-up were observed in pain intensity (P<0.001). No evidence for an association between the measures of WCH or CPM and intensity of chronic pain at follow-up was found. DISCUSSION:: A major predictive value of the measures that we used is unlikely. Future studies adopting other assessment modalities and possibly standardized treatments are needed to further elucidate the prognostic value of WCH and altered CPM in chronic pain.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Low back pain is associated with plasticity changes and central hypersensitivity in a subset of patients. We performed a case-control study to explore the discriminative ability of different quantitative sensory tests in distinguishing between 40 cases with chronic low back pain and 300 pain-free controls, and to rank these tests according to the extent of their association with chronic pain. Gender, age, height, weight, body mass index, and psychological measures were recorded as potential confounders. We used 26 quantitative sensory tests, including different modalities of pressure, heat, cold, and electrical stimulation. As measures of discrimination, we estimated receiver operating characteristics (ROC) and likelihood ratios. Six tests seemed useful (in order of their discriminative ability): (1) pressure pain detection threshold at the site of most severe pain (fitted area under the ROC, 0.87), (2) single electrical stimulation pain detection threshold (0.87), (3) single electrical stimulation reflex threshold (0.83), (4) pressure pain tolerance threshold at the site of most severe pain (0.81), (5) pressure pain detection threshold at suprascapular region (0.80), and (6) temporal summation pain threshold (0.80). Pressure and electrical pain modalities seemed most promising and may be used for diagnosis of pain hypersensitivity and potentially for identifying individuals at risk of developing chronic low back pain over time.