20 resultados para Lex Voconia.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: To investigate surface roughness and microhardness of two recent resin-ceramic materials for computer-aided design/computer-aided manufacturing (CAD/CAM) after polishing with three polishing systems. Surface roughness and microhardness were measured immediately after polishing and after six months storage including monthly artificial toothbrushing. Methods: Sixty specimens of Lava Ultimate (3M ESPE) and 60 specimens of VITA ENAMIC (VITA Zahnfabrik) were roughened in a standardized manner and polished with one of three polishing systems (n=20/group): Sof-Lex XT discs (SOFLEX; three-step (medium-superfine); 3M ESPE), VITA Polishing Set Clinical (VITA; two-step; VITA Zahnfabrik), or KENDA Unicus (KENDA; one-step; KENDA Dental). Surface roughness (Ra; μm) was measured with a profilometer and microhardness (Vickers; VHN) with a surface hardness indentation device. Ra and VHN were measured immediately after polishing and after six months storage (tap water, 37°C) including monthly artificial toothbrushing (500 cycles/month, toothpaste RDA ~70). Ra- and VHN-values were analysed with nonparametric ANOVA followed by Wilcoxon rank sum tests (α=0.05). Results: For Lava Ultimate, Ra (mean [standard deviation] before/after storage) remained the same when polished with SOFLEX (0.18 [0.09]/0.19 [0.10]; p=0.18), increased significantly with VITA (1.10 [0.44]/1.27 [0.39]; p=0.0001), and decreased significantly with KENDA (0.35 [0.07]/0.33 [0.08]; p=0.03). VHN (mean [standard deviation] before/after storage) decreased significantly regardless of polishing system (SOFLEX: 134.1 [5.6]/116.4 [3.6], VITA: 138.2 [10.5]/115.4 [5.9], KENDA: 135.1 [6.2]/116.7 [6.3]; all p<0.0001). For VITA ENAMIC, Ra (mean [standard deviation] before/after storage) increased significantly when polished with SOFLEX (0.37 [0.18]/0.41 [0.14]; p=0.01) and remained the same with VITA (1.32 [0.37]/1.31 [0.40]; p=0.58) and with KENDA (0.81 [0.35]/0.78 [0.32]; p=0.21). VHN (mean [standard deviation] before/after storage) remained the same regardless of polishing system (SOFLEX: 284.9 [24.6]/282.4 [31.8], VITA: 284.6 [28.5]/276.4 [25.8], KENDA: 292.6 [26.9]/282.9 [24.3]; p=0.42-1.00). Conclusion: Surface roughness and microhardness of Lava Ultimate was more affected by storage and artificial toothbrushing than was VITA ENAMIC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The goal of asthma treatment is to obtain clinical control and reduce future risks to the patient. To reach this goal in children with asthma, ongoing monitoring is essential. While all components of asthma, such as symptoms, lung function, bronchial hyperresponsiveness and inflammation, may exist in various combinations in different individuals, to date there is limited evidence on how to integrate these for optimal monitoring of children with asthma. The aims of this ERS Task Force were to describe the current practise and give an overview of the best available evidence on how to monitor children with asthma. 22 clinical and research experts reviewed the literature. A modified Delphi method and four Task Force meetings were used to reach a consensus. This statement summarises the literature on monitoring children with asthma. Available tools for monitoring children with asthma, such as clinical tools, lung function, bronchial responsiveness and inflammatory markers, are described as are the ways in which they may be used in children with asthma. Management-related issues, comorbidities and environmental factors are summarised. Despite considerable interest in monitoring asthma in children, for many aspects of monitoring asthma in children there is a substantial lack of evidence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The domain of context-free languages has been extensively explored and there exist numerous techniques for parsing (all or a subset of) context-free languages. Unfortunately, some programming languages are not context-free. Using standard context-free parsing techniques to parse a context-sensitive programming language poses a considerable challenge. Im- plementors of programming language parsers have adopted various techniques, such as hand-written parsers, special lex- ers, or post-processing of an ambiguous parser output to deal with that challenge. In this paper we suggest a simple extension of a top-down parser with contextual information. Contrary to the tradi- tional approach that uses only the input stream as an input to a parsing function, we use a parsing context that provides ac- cess to a stream and possibly to other context-sensitive infor- mation. At a same time we keep the context-free formalism so a grammar definition stays simple without mind-blowing context-sensitive rules. We show that our approach can be used for various purposes such as indent-sensitive parsing, a high-precision island parsing or XML (with arbitrary el- ement names) parsing. We demonstrate our solution with PetitParser, a parsing-expression grammar based, top-down, parser combinator framework written in Smalltalk.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Zielsetzung: Das Ziel dieser Studie war, den Einfluss von drei Politursystemen auf die Oberflächenrauigkeit von verschiedenen Materialien für computer-aided design/computer-aided manufacturing (CAD/CAM) Restaurationen mittels Profilometrie sowie die mikromechanischen Eigenschaften der Materialien mittels Mikrohärtemessgerät zu analysieren. Materialien und Methoden: Von dem CAD/CAM-Kompositmaterial Paradigm MZ100 (3M ESPE), der CAD/CAM-Feldspatkeramik VITABLOCS Mark II (VITA Zahnfabrik) und den CAD/CAM-Hybridmaterialien Lava Ultimate (3M ESPE), VITA ENAMIC (VITA Zahnfabrik) und AMBARINO High-Class (Creamed) wurden je 60 Prüfkörper zugeschnitten, gekennzeichnet und standardisiert aufgerauht. Die standardisierte Aufrauhung wurde mit Baseline-Rauigkeitsmessungen überprüft (Ra und Rz; µm). Die Prüfkörper wurden mit einem von drei Politursystemen poliert (n=20 pro CAD/CAM-Material): 1) Sof-Lex Scheiben (Disc-System, 3 Politurschritte: medium, fein und superfein; 3M ESPE), 2) VITA Polishing Set Clinical (Silikonpolitursystem, 2 Politurschritte: medium und fein; VITA Zahnfabrik) oder 3) KENDA Nobilis (Silikonpolierer, 1 Politurschritt (universal); KENDA Dental). Nach Politur der Prüfkörper wurden Ra und Rz sowie die mikromechanischen Eigenschaften Oberflächenhärte (VHN; Vickers Härte) und Elastizitätsmodul (EM; GPa) gemessen. In den darauf folgenden sechs Monaten wurden die Prüfkörper in Leitungswasser gelagert und insgesamt sechs Mal einem maschinellem Zahnbürsten zugeführt. Anschliessend wurden erneut Ra und Rz sowie VHN und EM gemessen. Ra-, Rz-, VHN- und EM-Werte wurden mittels nichtparametrischer ANOVA global analysiert und die p-Werte mittels Bonferroni-Holm Korrektur für multiples Testen korrigiert. Als post-hoc Tests wurden Kruskal-Wallis-Tests sowie exakte Wilcoxon Rangsummen-Tests verwendet und die p-Werte wurden nicht korrigiert. Das Signifikanzniveau wurde auf α=0,05 festgelegt. Resultate: Für alle drei CAD/CAM-Hybridmaterialien ergaben Sof-Lex Scheiben nach der Politur die tiefste Oberflächenrauigkeit (d. h. die tiefsten Ra- und Rz-Werte), gefolgt von KENDA Nobilis und von dem VITA Polishing Set Clinical. Bei dem CAD/CAM-Kompositmaterial sowie bei der CAD/CAM-Feldspatkeramik ergaben Sof-Lex Scheiben und KENDA Nobilis ähnliche Resultate, gefolgt von dem VITA Polishing Set Clinical. Bei einigen CAD/CAM-Materialien zeigten sich – zum Teil in Abhängigkeit des Politursystems – nach maschinellem Zahnbürsten und Lagerung signifikant höhere Ra- und Rz-Werte. Die CAD/CAM-Materialien zeigten unabhängig des Politursystems und der Lagerung signifikant verschiedene VHN- und EM-Werte. Bei einigen CAD/CAM-Materialien zeigten sich – zum Teil ebenfalls in Abhängigkeit des Politursystems – nach maschinellem Zahn-bürsten und Lagerung signifikant tiefere VHN- und EM-Werte. Schlussfolgerungen: Die Wahl des Politursystems beeinflusste die Oberflächenrauigkeit der CAD/CAM-Materialien markant, wobei Sof-Lex Scheiben insgesamt die besten Politurresultate zeigten, gefolgt von dem Silikonpolierer KENDA Nobilis. Von der Verwendung des Silikonpolitursystems VITA Polishing Set Clinical muss eher abgeraten werden. Das CAD/CAM-Kompositmaterial Paradigm MZ100 und die CAD/CAM-Hybridmaterialien Lava Ultimate und AMBARINO High-Class als weichere und elastischere Materialien liessen sich insgesamt besser polieren, waren aber bezüglich mechanischer Eigenschaften anfälliger auf Lagerung als die härtere CAD/CAM-Feldspatkeramik VITABLOCS Mark II und das CAD/CAM-Hybridmaterial VITA ENAMIC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die in Kraft getretene Raumplanungsverordnung zum revidierten Raumplanungsgesetz (RPG) überlässt es den Kantonen, ob diese bei der Abschätzung ihres Rückzonungsbedarfs von einem "hohen" oder "mittleren" Szenario zur Bevölkerungsentwicklung ausgehen wollen. - Obwohl die Kantone stark mit der Umsetzung der im Vorjahr angenommenen ersten RPG-Teilrevision beschäftigt waren, schickte der Bundesrat bereits eine Vorlage zur zweiten Revisionsetappe in die Vernehmlassung. - Der Ständerat befasste sich als Erstrat mit der Botschaft zur Umsetzung der Zweitwohnungsinitiative und reizte gemäss der zuständigen Bundesrätin den gesetzgeberischen Spielraum aus. - Das Parlament verzichtet definitiv auf die 2008 beschlossene Aufhebung der Lex Koller. - Trotz kontroverser Vernehmlassungsantworten beschloss die Regierung, an der Pflicht zur Bekanntgabe des Vormietzinses festzuhalten und gab die Erarbeitung einer entsprechenden Mietrechtsrevision in Auftrag. - Durch Annahme einer Motion beschloss das Parlament, dass die Veräusserung von Bauland aus landwirtschaftlichem Besitz erneut der Grundstückgewinnsteuer unterliegen soll.