27 resultados para Intravascular imaging(IVUS)
Resumo:
OBJECTIVES: The goal of the present study was to compare the accuracy of in vivo tissue characterization obtained by intravascular ultrasound (IVUS) radiofrequency (RF) data analysis, known as Virtual Histology (VH), to the in vitro histopathology of coronary atherosclerotic plaques obtained by directional coronary atherectomy. BACKGROUND: Vulnerable plaque leading to acute coronary syndrome (ACS) has been associated with specific plaque composition, and its characterization is an important clinical focus. METHODS: Virtual histology IVUS images were performed before and after a single debulking cut using directional coronary atherectomy. Debulking region of in vivo histology image was predicted by comparing pre- and post-debulking VH images. Analysis of VH images with the corresponding tissue cross section was performed. RESULTS: Fifteen stable angina pectoris (AP) and 15 ACS patients were enrolled. The results of IVUS RF data analysis correlated well with histopathologic examination (predictive accuracy from all patients data: 87.1% for fibrous, 87.1% for fibro-fatty, 88.3% for necrotic core, and 96.5% for dense calcium regions, respectively). In addition, the frequency of necrotic core was significantly higher in the ACS group than in the stable AP group (in vitro histopathology: 22.6% vs. 12.6%, p = 0.02; in vivo virtual histology: 24.5% vs. 10.4%, p = 0.002). CONCLUSIONS: Correlation of in vivo IVUS RF data analysis with histopathology shows a high accuracy. In vivo IVUS RF data analysis is a useful modality for the classification of different types of coronary components, and may play an important role in the detection of vulnerable plaque.
Resumo:
We used intravascular ultrasound (IVUS) and virtual histology (VH) to assess the differences of plaque burden and composition between target coronary arteries containing the culprit lesion and non-target coronary arteries.
Resumo:
OBJECTIVES Levels of inflammatory biomarkers associate with changes of coronary atheroma burden in statin-treated patients with stable coronary artery disease. This study sought to determine changes of plaque composition in vivo in relation to high-sensitivity C-reactive protein (hs-CRP) levels in patients with ST-elevation myocardial infarction (STEMI) receiving high-intensity statin therapy. METHODS The IBIS-4 study performed serial (baseline and 13-month), 2-vessel intravascular ultrasound (IVUS) and radiofrequency-IVUS of the non-infarct-related arteries in patients with STEMI treated with high-intensity statin therapy. The present analysis included 44 patients (80 arteries) with serial measurements of hs-CRP. RESULTS At follow-up, median low-density lipoprotein cholesterol (LDL-C) levels decreased from 126 to 77 mg/dl, HDL-C increased from 44 to 47 mg/dl, and hs-CRP decreased from 1.6 to 0.7 mg/L. Regression of percent atheroma volume (-0.99%, 95% CI -1.84 to -0.14, p = 0.024) was accompanied by reduction of percent fibro-fatty (p = 0.04) and fibrous tissue (p < 0.001), and increase in percent necrotic core (p = 0.006) and dense calcium (p < 0.001). Follow-up levels of hs-CRP, but not LDL-C, correlated with changes in percent necrotic core (p = 0.001) and inversely with percent fibrous tissue volume (p = 0.008). Similarly, baseline-to-follow-up change of hs-CRP correlated with the change in percent necrotic core volume (p = 0.02). CONCLUSIONS In STEMI patients receiving high-intensity statin therapy, stabilization of VH-IVUS-defined necrotic core was confined to patients with lowest on-treatment levels and greatest reduction of hs-CRP. Elevated CRP levels at follow-up may identify progression of high-risk coronary plaque composition despite intensive statin therapy and overall regression of atheroma volume.
Resumo:
Patients with diabetes mellitus are known to be at increased risk for acute cardiovascular events. We used intravascular ultrasound virtual histology (IVUS-VH) to examine whether nonobstructive coronary artery lesions of diabetic patients have distinct plaque composition and morphology compared with nondiabetic patients.
Resumo:
Implantation of a coronary stent results in a mechanical enlargement of the coronary lumen with stretching of the surrounding atherosclerotic plaque. Using intravascular ultrasound virtual-histology (IVUS-VH) we examined the temporal changes in composition of the plaque behind the struts (PBS) following the implantation of the everolimus eluting bioresorbable vascular scaffold (BVS). Using IVUS-VH and dedicated software, the composition of plaque was analyzed in all patients from the ABSORB B trial who were imaged with a commercially available IVUS-VH console (s5i system, Volcano Corporation, Rancho Cordova, CA, USA) post-treatment and at 6-month follow-up. This dedicated software enabled analysis of the PBS after subtraction of the VH signal generated by the struts. The presence of necrotic core (NC) in contact with the lumen was also evaluated at baseline and follow-up. IVUS-VH data, recorded with s5i system, were available at baseline and 6-month follow-up in 15 patients and demonstrated an increase in both the area of PBS (2.45 ± 1.93 mm(2) vs. 3.19 ± 2.48 mm(2), P = 0.005) and the external elastic membrane area (13.76 ± 4.07 mm(2) vs. 14.76 ± 4.56 mm(2), P = 0.006). Compared to baseline there was a significant progression in the NC (0.85 ± 0.70 mm(2) vs. 1.21 ± 0.92 mm(2), P = 0.010) and fibrous tissue area (0.88 ± 0.79 mm(2) vs. 1.15 ± 1.05 mm(2), P = 0.027) of the PBS. The NC in contact with the lumen in the treated segment did not increase with follow-up (7.33 vs. 6.36%, P = 0.2). Serial IVUS-VH analysis of BVS-treated lesions at 6-month demonstrated a progression in the NC and fibrous tissue content of PBS.
Resumo:
Coronary late stent thrombosis, a rare but devastating complication, remains an important concern in particular with the increasing use of drug-eluting stents. Notably, pathological studies have indicated that the proportion of uncovered coronary stent struts represents the best morphometric predictor of late stent thrombosis. Intracoronary optical frequency domain imaging (OFDI), a novel second-generation optical coherence tomography (OCT)-derived imaging method, may allow rapid imaging for the detection of coronary stent strut coverage with a markedly higher precision when compared with intravascular ultrasound, due to a microscopic resolution (axial approximately 10-20 microm), and at a substantially increased speed of image acquisition when compared with first-generation time-domain OCT. However, a histological validation of coronary OFDI for the evaluation of stent strut coverage in vivo is urgently needed. Hence, the present study was designed to evaluate the capacity of coronary OFDI by electron (SEM) and light microscopy (LM) analysis to detect and evaluate stent strut coverage in a porcine model.
Resumo:
Serial intravascular ultrasound virtual histology (IVUS-VH) after implantation of metallic stents has been unable to show any changes in the composition of the scaffolded plaque overtime. The everolimus-eluting ABSORB scaffold potentially allows for the formation of new fibrotic tissue on the scaffolded coronary plaque during bioresorption. We examined the 12 month IVUS-VH changes in composition of the plaque behind the struts (PBS) following the implantation of the ABSORB scaffold. Using IVUS-VH and dedicated software, the composition of the PBS was analyzed in all patients from the ABSORB Cohort B2 trial, who were imaged with a commercially available IVUS-VH console (s5i system, Volcano Corporation, Rancho Cordova, CA, USA), immediately post-ABSORB implantation and at 12 month follow-up. Paired IVUS-VH data, recorded with s5i system, were available in 17 patients (18 lesions). The analysis demonstrated an increase in mean PBS area (2.39 ± 1.85 mm(2) vs. 2.76 ± 1.79 mm(2), P = 0.078) and a reduction in the mean lumen area (6.37 ± 0.90 mm(2) vs. 5.98 ± 0.97 mm(2), P = 0.006). Conversely, a significant decrease of 16 and 30% in necrotic core (NC) and dense calcium (DC) content, respectively, were evident (median % NC from 43.24 to 36.06%, P = 0.016; median % DC from 20.28 to 11.36%, P = 0.002). Serial IVUS-VH analyses of plaque located behind the ABSORB struts at 12-month demonstrated an increase in plaque area with a decrease in its NC and DC content. Larger studies are required to investigate the clinical impact of these findings.
Resumo:
Background The evaluation of the hepatic parenchyma in patients with chronic liver disease is important to assess the extension, localization and relationship with adjacent anatomical structures of possible lesions. This is usually performed with conventional abdominal ultrasound, CT-scan or magnetic resonance imaging. In this context, the feasibility and the safety of intravascular ultrasound in the liver have not been assessed yet. Methods We tested the safety and performance of an intracardiac echography (ICE) catheter applied by a transjugular approach into the hepatic veins in patients with chronic liver disease undergoing hepatic hemodynamic measurements. Results Five patients were enrolled in this pilot study. The insertion of the ICE catheter was possible into the right and middle, but not into the left hepatic vein. The position of the ICE was followed using fluoroscopy and external conventional ultrasound. Accurate imaging of focal hepatic parenchymal lesions, Doppler ultrasound of surrounding blood vessels and assessment of liver surface and ascites were achieved without complications. Conclusions This study demonstrated that a diagnostic approach using an ICE device inserted in the hepatic veins is feasible, safe and well tolerated. However, it remains for the moment only an experimental investigative tool. Whether ICE adds further information regarding parenchymal lesions and associated vascular alterations as compared to other techniques, needs additional investigation.
Resumo:
To analyse and to compare the changes in the various optical coherence tomography (OCT), echogenicity and intravascular ultrasound virtual histology (VH) of the everolimus-eluting bioresorbable scaffold (ABSORB) degradation parameters during the first 12 months after ABSORB implantation. In the ABSORB study, changes in the appearance of the ABSORB scaffold were monitored over time using various intracoronary imaging modalities. The scaffold struts exhibited a progressive change in their black core area by OCT, in their ultrasound derived grey level intensity quantified by echogenicity, and in their backscattering ultrasound signal, identified as "pseudo dense-calcium" (DC) by VH.
Resumo:
PURPOSE: To evaluate the feasibility and effectiveness of IVUS-guided puncture for gaining controlled target lumen reentry in subintimal recanalization of chronic iliac/femoral artery occlusions and in fenestration of aortic dissections. MATERIALS AND METHODS: Between 5/2004 and 12/2005 12 consecutive patients (7 male, 5 female; mean age 64.6 +/- 12.0 years) with chronic critical limb ischemia and ischemic complications of aortic dissection were treated using the Pioneer catheter. This 6.2-F dual-lumen catheter combines a 20-MHz IVUS transducer with a pre-shaped extendable, hollow 24-gauge nitinol needle. This coaxial needle allows real-time IVUS-guided puncture of the target lumen and after successful reentry a 0.014" guidewire may be advanced through the needle into the target lumen. 7 patients were treated for aortic dissection and 5 patients (with failed previous attempts at subintimal recanalization) for chronic arterial occlusion. Patients with aortic dissection (5 type A dissections, 2 type B dissections) had developed renal ischemia (n = 2), renal and mesenteric ischemia (n = 2), or low extremity ischemia (n = 3). Patients with chronic arterial occlusions (2 common iliac artery occlusions, 3 superficial femoral artery occlusions) experienced ischemic rest pain (n = 4), and a non-healing foot ulcer (n = 1). RESULTS: The technical success rate using the Pioneer catheter was 100%. The recanalization/fenestration time was 37 +/- 12 min. Procedure-related complications did not occur. In 10 cases a significant improvement of clinical symptoms was evident. One patient with aortic dissection and ischemic paraplegia required subsequent surgical intervention. One patient had persistent ischemic rest pain despite successful recanalization of a superficial femoral artery occlusion. CONCLUSION: The Pioneer catheter is a reliable device which may be helpful for achieving target lumen reentry in subintimal recanalization of chronic occlusions and in fenestration of aortic dissections.
Resumo:
AIMS: To evaluate the plaque composition obtained by virtual histology (VH) IVUS according to the clinical presentation and to compare those data to previously published histopathology data. METHODS AND RESULTS: VH was performed on 95 de novo significant lesions (>75% stenosis) in 85 patients [28 acute coronary syndrome (ACS) patients, 30 lesions; 57 stable angina pectoris (SAP) patients, 65 lesions]. There were a higher prevalence of positive remodelling (47 vs. 22%, P=0.013), thrombus (20 vs. 1.5%, P=0.0037), and echo-lucent area (23.3 vs. 7.7%, P=0.047) in ACS patients. At the minimal lumen site, fibrous plaque area was significantly larger in ACS lesions than in SAP lesions (66.0+/-10.7 vs. 61.4+/-8.9%, P=0.034), whereas necrotic core and dense calcium plaque area were smaller in ACS lesions (Necrotic core: 6.8+/-6.0 vs. 11.0+/-8.3%, P=0.02; Dense calcium: 2.6+/-3.0 vs. 4.9+/-5.8%, P=0.03). No differences in rate of thin cap fibroatheroma, thick fibrotheroma, or for the presence of multiple necrotic core layers were observed between both groups. CONCLUSION: Plaque composition obtained by VH-IVUS shows less necrotic core and more fibrous tissue in ACS compared to SAP lesions, which is in contradiction with previously published histopathologic data.
Resumo:
We present a case where multi-phase post-mortem computed tomography angiography (PMCTA) induced a hemorrhagic pericardial effusion during the venous phase of angiography. Post-mortem non-contrast CT (PMCT) suggested the presence of a ruptured aortic dissection. This diagnosis was confirmed by PMCTA after pressure controlled arterial injection of contrast. During the second phase of multi-phase PMCTA the presence of contrast leakage from the inferior cava vein into the pericardial sac was noted. Autopsy confirmed the post-mortem nature of this vascular tear. This case teaches us an important lesson: it underlines the necessity to critically analyze PMCT and PMCTA images in order to distinguish between artifacts, true pathologies and iatrogenic findings. In cases with ambiguous findings such as the case reported here, correlation of imaging findings with autopsy is elementary.