96 resultados para Intermittent catheter


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background—Pulmonary vein stenosis (PVST) is a well-known complication of pulmonary vein isolation (PVI). Specific anatomically designed ablation catheters for antral PVI have not been evaluated with regard to the incidence of PVST. We investigated the incidence, severity, and characteristics of PVST after PVI with the Pulmonary Vein Ablation Catheter (PVAC) and phased radiofrequency technology. Methods and Results A total of 100 patients (55 men) underwent PVI for atrial fibrillation using the PVAC. PVI was guided by selective angiography of each pulmonary vein (PV) in 70 (70%) patients and by reconstructed 3D atriography (ATG) in 30 (30%) patients. Gadolinium-enhanced MRI or multidetector CT was performed in all patients before treatment and 93±78 days after PVI. PVST was classified as follows: insignificant (<25%), mild (25%–50%), moderate (50%–75%), or severe (>75%). A total of 410 PVs were analyzed. Cardiac imaging demonstrated a detectable narrowing of the PV diameter in 23 (23%) patients and in 28 (7%) PVs. In detail, insignificant PVST was observed in 12 (2.9%) PVs, mild PVST in 15 (3.7%), and moderate PVST in 1 (0.2%). No instances of severe PVST were observed. The use of 3D-ATG was associated with a lower incidence of PVST (0.8% [95% CI, 0.0%–2.2%] versus 5.4% [95% CI, 2.7%–8.1%], P=0.027). Conclusions To our knowledge, this study is the first to report the incidence of PVST using the PVAC. In this regard, the PVAC seems to be safe if used in an experienced center. In addition, the use of 3D-ATG may decrease the risk of PVST.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A first case of coronary stent implantation through a 4 French diagnostic catheter is described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurements of maximum urethral closure pressure (MUCP) are a part of urodynamic investigations preceding an incontinence surgery and a part of urethral function tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To determine the optimal stochastic whole body vibration (SR-WBV) load modality regarding pelvic floor muscle (PFM) activity in order to complete the SR-WBV training methodology for future PFM training with SR-WBV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ilio-femoral deep vein thrombosis (DVT) has a high rate of long-term morbidity in the form of the postthrombotic syndrome (PTS). Therefore, management of acute thrombosis should not only focus on the prevention of acute complications such as propagation or embolisation of the initial clot but also on preventing PTS and recurrent thrombosis. Contemporary catheter-based treatments of deep vein thrombosis have proven to be safe and effective in selected patients. Current guidelines recommend medical therapy with anticoagulation alone for all but the most severe, limb-threatening thrombosis. They additionally allow for consideration of catheter-based treatment in patients with acute DVT and low risk of bleeding complications to prevent PTS. Recent studies favoring interventional therapy have not been included in these guidelines. Data on long-term outcome is expected to be published soon, clarifying and very likely strengthening the role of catheter-based treatments in the management of acute ilio-femoral DVT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the feasibility and effectiveness of IVUS-guided puncture for gaining controlled target lumen reentry in subintimal recanalization of chronic iliac/femoral artery occlusions and in fenestration of aortic dissections. MATERIALS AND METHODS: Between 5/2004 and 12/2005 12 consecutive patients (7 male, 5 female; mean age 64.6 +/- 12.0 years) with chronic critical limb ischemia and ischemic complications of aortic dissection were treated using the Pioneer catheter. This 6.2-F dual-lumen catheter combines a 20-MHz IVUS transducer with a pre-shaped extendable, hollow 24-gauge nitinol needle. This coaxial needle allows real-time IVUS-guided puncture of the target lumen and after successful reentry a 0.014" guidewire may be advanced through the needle into the target lumen. 7 patients were treated for aortic dissection and 5 patients (with failed previous attempts at subintimal recanalization) for chronic arterial occlusion. Patients with aortic dissection (5 type A dissections, 2 type B dissections) had developed renal ischemia (n = 2), renal and mesenteric ischemia (n = 2), or low extremity ischemia (n = 3). Patients with chronic arterial occlusions (2 common iliac artery occlusions, 3 superficial femoral artery occlusions) experienced ischemic rest pain (n = 4), and a non-healing foot ulcer (n = 1). RESULTS: The technical success rate using the Pioneer catheter was 100%. The recanalization/fenestration time was 37 +/- 12 min. Procedure-related complications did not occur. In 10 cases a significant improvement of clinical symptoms was evident. One patient with aortic dissection and ischemic paraplegia required subsequent surgical intervention. One patient had persistent ischemic rest pain despite successful recanalization of a superficial femoral artery occlusion. CONCLUSION: The Pioneer catheter is a reliable device which may be helpful for achieving target lumen reentry in subintimal recanalization of chronic occlusions and in fenestration of aortic dissections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Herbal drugs are being increasingly used in medical practice, often without appropriate scrutiny of their safety and efficacy. The medicinal product Padma 28 is a fixed combination with Tibetan origin, used in Europe since the 1960s for the symptomatic treatment of circulatory disorders, including those of peripheral arterial occlusive disease (PAOD). We have conducted an analysis of all available data on this herbal drug from published literature as well as from original data we obtained from contacting the authors of published papers, reports and the manufacturer. A total of 19 trials have reported on 2084 patients to date, 444 of whom were in six controlled clinical studies on PAOD. A meta-analysis of five trials showed Padma 28 to increase walking distance by >100m in 18.2% of the patients with verum, versus 2.1% with placebo (P<0.001; odds ratio: 10 [95% CI 3.03, 33.33]; RR: 0.12; number needed to treat=6.2). The safety profile appears to be favourable. Available evidence shows that Padma 28 provides significant relief from PAOD-related symptoms (i.e. walking distance), probably of the same order of magnitude as other employed medications. However, larger confirmatory RCTs are desirable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pulmonary artery catheter (PAC) is a powerful tool that has been used extensively in the assessment and monitoring of cardiovascular physiology. Gross misinterpretation of data gathered by the PAC is common, and its routine use without any specific interventions has not been shown to influence outcome. However, there currently is no evidence from randomized, controlled trials that any diagnostic or monitoring tool used in intensive care patients improves outcome. Studies evaluating the use of the PAC have included numerous potential confounding factors, and should be interpreted with caution. The information obtained with the PAC should be used to find better treatment strategies, and these strategies, instead of the tool itself, should be tested in clinical trials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The rodent model of myocardial infarction (MI) is extensively used in heart failure studies. However, long-term follow-up of echocardiographic left ventricular (LV) function parameters such as the myocardial performance index (MPI) and its ratio with the fractional shortening (LVFS/MPI) has not been validated in conjunction with invasive indexes, such as those derived from the conductance catheter (CC). Sprague-Dawley rats with left anterior descending coronary artery ligation (MI group, n = 9) were compared with a sham-operated control group (n = 10) without MI. Transthoracic echocardiography (TTE) was performed every 2 wk over an 8-wk period, after which classic TTE parameters, especially MPI and LVFS/MPI, were compared with invasive indexes obtained by using a CC. Serial TTE data showed significant alterations in the majority of the noninvasive functional and structural parameters (classic and novel) studied in the presence of MI. Both MPI and LVFS/MPI significantly (P < 0.05 for all reported values) correlated with body weight (r = -0.58 and 0.76 for MPI and LVFS/MPI, respectively), preload recruitable stroke work (r = -0.61 and 0.63), LV end-diastolic pressure (LVEDP) (r = 0.82 and -0.80), end-diastolic volume (r = 0.61 and -0.58), and end-systolic volume (r = 0.46 and -0.48). Forward stepwise linear regression analysis revealed that, of all variables tested, LVEDP was the only independent determinant of MPI (r = 0.84) and LVFS/MPI (r = 0.83). We conclude that MPI and LVFS/MPI correlate strongly and better than the classic noninvasive TTE parameters with established, invasively assessed indexes of contractility, preload, and volumetry. These findings support the use of these two new noninvasive indexes for long-term analysis of the post-MI LV remodeling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite changes in patient demographics and short-ened length of hospital stay deep vein thrombosis (DVT) remains a major health care problem which may lead to a variety of other high risk complications. Current treatment guidelines focus on preventive measures. Beside drug therapy, physical measures executed by nursing professionals exist, the outcomes of which are discussed controversially. Based on 25 studies that were found in MEDLINE and the Cochrane library, this systematic literature review identifies the effectiveness of intermittent pneumatic compression (IPC) on thrombosis prophylaxis. In almost all medical settings IPC contributes to a significant reduction of the incidence of DVT. At the same time, IPC has minimal negative side effects and is also cost effective. Correct application of IPC and patient compliance are essential to achieve its effectiveness. An increased awareness within the healthcare team in identifying the risk for and implementing measures against DVT is needed. Guidelines need to be developed in order to improve the effectiveness of thrombosis prophylaxis with the implementation of IPC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The tradition of yearly reports on cardiac catheter interventions in Europe has been initiated in 1992. This 11th report presents aggregated data on cardiac catheter procedures in 30 European countries in the year 2002. DESIGN AND SETTING: A detailed questionnaire addressing summary data of all cardiac interventions was mailed to presidents or delegates of the national societies of cardiology in Europe. The questionnaire was distributed to all institutions with cardiac catheterisation programs. All questionnaires were compiled in a national summary data sheet, then entered into a central database and subsequently analysed. MAIN OUTCOME MEASURES: Coronary angiography, PTCA, and stenting in absolute numbers and per million inhabitants in the participating countries and the whole of Europe. RESULTS: Overall, 1,901,932 coronary angiograms were reported. The population-adjusted rate of coronary angiograms amounted to an absolute mean of 3358 per 10(6) inhabitants, an increase of 7% compared with 2001. A total of 686,869 PTCA procedures were reported. The mean European number of PTCAs per 10(6) inhabitants increased by 10% from 1103 in 2001 to 1213 in 2002. Procedures with stenting increased by 17% from 508,999 to 593,906. The stenting rate was 86% compared with 82% in 2001. CONCLUSIONS: In pace with epidemiological demand and the need to catch-up from underuse in certain countries, a continuous and considerable growth of coronary interventions can be observed. It will take years to find out whether the announced change of paradigm in the treatment of multivessel disease in the wake of drug-eluting stents will come true.