24 resultados para Integrated system


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This report on The Potential of Mode of Action (MoA) Information Derived from Non-testing and Screening Methodologies to Support Informed Hazard Assessment, resulted from a workshop organised within OSIRIS (Optimised Strategies for Risk Assessment of Industrial Chemicals through Integration of Non-test and Test Information), a project partly funded by the EU Commission within the Sixth Framework Programme. The workshop was held in Liverpool, UK, on 30 October 2008, with 35 attendees. The goal of the OSIRIS project is to develop integrated testing strategies (ITS) fit for use in the REACH system, that would enable a significant increase in the use of non-testing information for regulatory decision making, and thus minimise the need for animal testing. One way to improve the evaluation of chemicals may be through categorisation by way of mechanisms or modes of toxic action. Defining such groups can enhance read-across possibilities and priority settings for certain toxic modes or chemical structures responsible for these toxic modes. Overall, this may result in a reduction of in vivo testing on organisms, through combining available data on mode of action and a focus on the potentially most-toxic groups. In this report, the possibilities of a mechanistic approach to assist in and guide ITS are explored, and the differences between human health and environmental areas are summarised.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The shift of psychiatric care from the hospital to the community has been accompanied by a reduction of hospital beds and shortened durations of inpatient treatment, but also by an increase in admissions. This evolution may be largely attributed to the prime focus of community mental health institutions on rehabilitation. The continued implementation of reforms in psychiatric care is contingent upon effectively halting the "revolving door phenomenon" by incorporating community-integrated treatment approaches into the care of acutely ill patients. Since the mid-1960s, a series of studies have established the efficacy of two community-integrated modalities for the treatment of acute psychiatric illness, i.e. home-based and day hospital treatment. In general, these approaches not only seem to be as effective as inpatient care for certain groups of patients but also reduce their need of hospitalisation, thereby contributing towards a cost effective, comprehensive psychiatric care system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, we propose an intelligent method, named the Novelty Detection Power Meter (NodePM), to detect novelties in electronic equipment monitored by a smart grid. Considering the entropy of each device monitored, which is calculated based on a Markov chain model, the proposed method identifies novelties through a machine learning algorithm. To this end, the NodePM is integrated into a platform for the remote monitoring of energy consumption, which consists of a wireless sensors network (WSN). It thus should be stressed that the experiments were conducted in real environments different from many related works, which are evaluated in simulated environments. In this sense, the results show that the NodePM reduces by 13.7% the power consumption of the equipment we monitored. In addition, the NodePM provides better efficiency to detect novelties when compared to an approach from the literature, surpassing it in different scenarios in all evaluations that were carried out.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES We sought to evaluate the strategy success and short term clinical outcomes of direct stenting via 5 French (F) diagnostic catheters using a novel bare metal stent with integrated delivery system (IDS) (Svelte Medical Systems, New Providence, NJ) and compare the results to a conventionally treated matched group. METHODS Fifteen consecutive patients with lesions deemed suitable for direct stenting using a bare metal stent were included. The primary endpoint was the strategy success defined as the ability to successfully treat a target lesion via a 5 F diagnostic catheter with a good angiographic result (TIMI III flow, residual stenosis ≤20%). Procedure and fluoroscopy times, contrast agent use, cost, and short-term clinical outcomes were compared to a matched group treated via conventional stenting. RESULTS The primary endpoint was reached in 14/15 patients (93%). There were no significant differences in procedural (58.6 min ± 12.7 vs. 57.4 min ± 14.2) or fluoroscopy times (10.0 min ± 4.3 vs.10.1 min ± 3.9) or contrast agent use (193.7 ml ± 54.8 vs. 181.4 ml ± 35.6). However, there were significant reductions in materials used in the study group compared to the control group equating to cost savings of almost US $600 per case (US $212.44 ± 258.09 vs. US $804.69 ± 468.11; P = 0.001). CONCLUSIONS Direct stenting using a novel bare metal stent with an IDS via 5 F diagnostic catheters is a viable alternative to conventional stenting in selected patients and is associated with significant cost savings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A compact adjustable focusing system for a 2 MeV H- RFQ Linac is designed, constructed and tested based on four permanent magnet quadrupoles (PMQ). A PMQ model is realised using finite element simulations, providing an integrated field gradient of 2.35 T with a maximal field gradient of 57 T/m. A prototype is constructed and the magnetic field is measured, demonstrating good agreement with the simulation. Particle track simulations provide initial values for the quadrupole positions. Accordingly, four PMQs are constructed and assembled on the beam line, their positions are then tuned to obtain a minimal beam spot size of (1.2 x 2.2) mm^2 on target. This paper describes an adjustable PMQ beam line for an external ion beam. The novel compact design based on commercially available NdFeB magnets allows high flexibility for ion beam applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The "Hamburg model" designates an integrated care model for severely ill patients with psychotic disorders financed by the health insurance system in accordance with § 140 SGB V.Methods: It comprises comprehensive and long-term treatment within a regional network of the psychosis center of the University Medical Center Hamburg-Eppendorf (UKE) and private psychiatrists. The treatment model consists of therapeutic assertive community treatment (ACT) provided by a highly specialized treatment team and need-adapted in- and outpatient care.Results and conclusions: The present article summarizes the disease- and treatment-specific rationales for the model development as well as the model structure and treatment contents. The article further summarizes the effectiveness and efficiency results of a study comparing the Hamburg model and treatment as usual (without ACT) within a 12-month follow-up study (ACCESS trial).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS Information on tumour border configuration (TBC) in colorectal cancer (CRC) is currently not included in most pathology reports, owing to lack of reproducibility and/or established evaluation systems. The aim of this study was to investigate whether an alternative scoring system based on the percentage of the infiltrating component may represent a reliable method for assessing TBC. METHODS AND RESULTS Two hundred and fifteen CRCs with complete clinicopathological data were evaluated by two independent observers, both 'traditionally' by assigning the tumours into pushing/infiltrating/mixed categories, and alternatively by scoring the percentage of infiltrating margin. With the pushing/infiltrating/mixed pattern method, interobserver agreement (IOA) was moderate (κ = 0.58), whereas with the percentage of infiltrating margins method, IOA was excellent (intraclass correlation coefficient of 0.86). A higher percentage of infiltrating margin correlated with adverse features such as higher grade (P = 0.0025), higher pT (P = 0.0007), pN (P = 0.0001) and pM classification (P = 0.0063), high-grade tumour budding (P < 0.0001), lymphatic invasion (P < 0.0001), vascular invasion (P = 0.0032), and shorter survival (P = 0.0008), and was significantly associated with an increased probability of lymph node metastasis (P < 0.001). CONCLUSIONS Information on TBC gives additional prognostic value to pathology reports on CRC. The novel proposed scoring system, by using the percentage of infiltrating margin, outperforms the 'traditional' way of reporting TBC. Additionally, it is reproducible and simple to apply, and can therefore be easily integrated into daily diagnostic practice.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE Laser range scanners (LRS) allow performing a surface scan without physical contact with the organ, yielding higher registration accuracy for image-guided surgery (IGS) systems. However, the use of LRS-based registration in laparoscopic liver surgery is still limited because current solutions are composed of expensive and bulky equipment which can hardly be integrated in a surgical scenario. METHODS In this work, we present a novel LRS-based IGS system for laparoscopic liver procedures. A triangulation process is formulated to compute the 3D coordinates of laser points by using the existing IGS system tracking devices. This allows the use of a compact and cost-effective LRS and therefore facilitates the integration into the laparoscopic setup. The 3D laser points are then reconstructed into a surface to register to the preoperative liver model using a multi-level registration process. RESULTS Experimental results show that the proposed system provides submillimeter scanning precision and accuracy comparable to those reported in the literature. Further quantitative analysis shows that the proposed system is able to achieve a patient-to-image registration accuracy, described as target registration error, of [Formula: see text]. CONCLUSIONS We believe that the presented approach will lead to a faster integration of LRS-based registration techniques in the surgical environment. Further studies will focus on optimizing scanning time and on the respiratory motion compensation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Implementation of user-friendly, real-time, electronic medical records for patient management may lead to improved adherence to clinical guidelines and improved quality of patient care. We detail the systematic, iterative process that implementation partners, Lighthouse clinic and Baobab Health Trust, employed to develop and implement a point-of-care electronic medical records system in an integrated, public clinic in Malawi that serves HIV-infected and tuberculosis (TB) patients. METHODS Baobab Health Trust, the system developers, conducted a series of technical and clinical meetings with Lighthouse and Ministry of Health to determine specifications. Multiple pre-testing sessions assessed patient flow, question clarity, information sequencing, and verified compliance to national guidelines. Final components of the TB/HIV electronic medical records system include: patient demographics; anthropometric measurements; laboratory samples and results; HIV testing; WHO clinical staging; TB diagnosis; family planning; clinical review; and drug dispensing. RESULTS Our experience suggests that an electronic medical records system can improve patient management, enhance integration of TB/HIV services, and improve provider decision-making. However, despite sufficient funding and motivation, several challenges delayed system launch including: expansion of system components to include of HIV testing and counseling services; changes in the national antiretroviral treatment guidelines that required system revision; and low confidence to use the system among new healthcare workers. To ensure a more robust and agile system that met all stakeholder and user needs, our electronic medical records launch was delayed more than a year. Open communication with stakeholders, careful consideration of ongoing provider input, and a well-functioning, backup, paper-based TB registry helped ensure successful implementation and sustainability of the system. Additional, on-site, technical support provided reassurance and swift problem-solving during the extended launch period. CONCLUSION Even when system users are closely involved in the design and development of an electronic medical record system, it is critical to allow sufficient time for software development, solicitation of detailed feedback from both users and stakeholders, and iterative system revisions to successfully transition from paper to point-of-care electronic medical records. For those in low-resource settings, electronic medical records for integrated care is a possible and positive innovation.