217 resultados para Implant


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare the soft and hard tissue healing and remodeling around tissue-level implants with different neck configurations after at least 1 year of functional loading. Material and methods: Eighteen patients with multiple missing teeth in the posterior area received two implants inserted in the same sextant. One test (T) implant with a 1.8 mm turned neck and one control (C) implant with a 2.8 mm turned neck were randomly assigned. All implants were placed transmucosally to the same sink depth of approximately 1.8 mm. Peri-apical radiographs were obtained using the paralleling technique and digitized. Two investigators blinded to the implant type-evaluated soft and hard tissue conditions at baseline, 6 months and 1 year after loading. Results: The mean crestal bone levels and soft tissue parameters were not significantly different between T and C implants at all time points. However, T implants displayed significantly less crestal bone loss than C implants after 1 year. Moreover, a frequency analysis revealed a higher percentage (50%) of T implants with crestal bone levels 1–2 mm below the implant shoulder compared with C implants (5.6%) 1 year after loading. Conclusion: Implants with a reduced height turned neck of 1.8 mm may, indeed, lower the crestal bone resorption and hence, may maintain higher crestal bone levels than do implants with a 2.8 mm turned neck, when sunk to the same depth. Moreover, several factors other than the vertical positioning of the moderately rough SLA surface may influence crestal bone levels after 1 year of function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

http://www.ncbi.nlm.nih.gov/pubmed/20153849

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: After oral tumor resection, structural and functional rehabilitation by means of dental prostheses is complex, and positive treatment outcome is not always predictable. Purpose: The objective of the study was to report on oral rehabilitation and quality of life 2-5 years after resection of malignant oral tumors. Materials and Methods: Data of 46 patients (57 ± 7 years) who underwent oral tumor surgery were available. More than 50% of tumors were classified T3 or T4. Open oro-nasal defects resulted in 12 patients and full mandibulary block resections in 23 patients. Comprehensive planning, implant placement, and prosthetic rehabilitation followed an interdisciplinary protocol. Analysis comprised tumor location, type of prostheses, implant survival, and quality of life. Results: Because of advanced tumor status, resections resulted in marked alteration of the oral anatomy requiring complex treatment procedures. Prosthetic rehabilitation comprised fixed and removable prostheses, with 104 implants placed in 28 patients (60%). Early implant loss was high (13%) and cumulative survival rate of loaded implants was <90% after 5 years. Prosthetic plans had to be modified because of side effects of tumor therapy, complications with implants and tumor recurrence. The majority of patients rated quality of life favorable, but some experienced impaired swallowing, dry mouth, limited mouth opening, appearance, and soreness. Conclusions: Some local effects of tumor therapy could not be significantly improved by prosthetic rehabilitation leading to functional and emotional disability. Many patients had passed away or felt too ill to fill the questionnaires. This case series confirms the complex anatomic alterations after tumor resection and the need for individual treatment approaches especially regarding prosthesis design. In spite of disease-related local and general restrictions, most patients gave a positive assessment of quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concept of platform switching has been introduced to implant dentistry based on observations of reduced peri-implant bone loss. However, randomized clinical trials are still lacking. This study aimed to test the hypothesis that platform switching has a positive impact on crestal bone-level changes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To analyze maintenance service of fixed maxillary prostheses and overdentures based on conventional gold bars or titanium bars and frameworks fabricated with computer-aided design/computer-assisted manufacture (CAD/CAM) technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study summarizes the long-term clinical observations of edentulous patients treated with mandibular implant-supported overdentures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To compare the gene expression profile of osseointegration associated with a moderately rough and a chemically modified hydrophilic moderately rough surface in a human model. MATERIAL AND METHODS: Eighteen solid screw-type cylindrical titanium implants, 4 mm long and 2.8 mm wide, with either a moderately rough (SLA) or a chemically modified moderately rough (SLActive) surface were surgically inserted in the retromolar area of nine human volunteers. The devices were removed using a trephine following 4, 7 and 14 days of healing. The tissue surrounding the implant was harvested, total RNA was extracted and microarray analysis was carried out to identify the differences in the transcriptome between the SLA and SLActive surfaces at days 4, 7 and 14. RESULTS: There were no functionally relevant gene ontology categories that were over-represented in the list of genes that were differentially expressed at day 4. However, by day 7, osteogenesis- and angiogenesis-associated gene expression were up-regulated on the SLActive surface. Osteogenesis and angiogenesis appeared to be regulated by BMP and VEGF signalling, respectively. By day 14, VEGF signalling remains up-regulated on the SLActive surface, while BMP signalling was up-regulated on the SLA surface in what appeared to be a delayed compensatory response. Furthermore, neurogenesis was a prominent biological process within the list of differentially expressed genes, and it was influenced by both surfaces. CONCLUSIONS: Compared with SLA, SLActive exerts a pro-osteogenic and pro-angiogenic influence on gene expression at day 7 following implant insertion, which may be responsible for the superior osseointegrative properties of this surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate morphologically and morphometrically the sequential healing and osseointegration events at moderately rough implant surfaces with and without chemical modification. Particularly the role of bone debris in initiating bone formation was emphasized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the rate and degree of osseointegration at chemically modified moderately rough, hydrophilic (SLActive) and moderately rough, hydrophobic (SLA) implant surfaces during early phases of healing in a human model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To compare the effectiveness of two anti-infective protocols for the treatment of peri-implant mucositis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: A recent in vivo study has shown considerable contamination of internal implant and suprastructure components with great biodiversity, indicating bacterial leakage along the implant-abutment interface, abutment-prosthesis interface, and restorative margins. The goal of the present study was to compare microbiologically the peri-implant sulcus to these internal components on implants with no clinical signs of peri-implantitis and in function for many years. Checkerboard DNA-DNA hybridization was used to identify and quantify 40 species. Material and Methods: Fifty-eight turned titanium Brånemark implants in eight systemically healthy patients (seven women, one man) under regular supportive care were examined. All implants had been placed in the maxilla and loaded with a screw-retained full-arch bridge for an average of 9.6 years. Gingival fluid samples were collected from the deepest sulcus per implant for microbiological analysis. As all fixed restorations were removed, the cotton pellet enclosed in the intra-coronal compartment and the abutment screw were retrieved and microbiologically evaluated. Results: The pellet enclosed in the suprastructure was very similar to the peri-implant sulcus in terms of bacterial detection frequencies and levels for practically all the species included in the panel. Yet, there was virtually no microbial link between these compartments. When comparing the abutment screw to the peri-implant sulcus, the majority of the species were less frequently found, and in lower numbers at the former. However, a relevant link in counts for a lot of bacteria was described between these compartments. Even though all implants in the present study showed no clinical signs of peri-implantitis, the high prevalence of numerous species associated with pathology was striking. Conclusions: Intra-coronal compartments of screw-retained fixed restorations were heavily contaminated. The restorative margin may have been the principal pathway for bacterial leakage. Contamination of abutment screws most likely occurred from the peri-implant sulcus via the implant-abutment interface and abutment-prosthesis interface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To determine the dimensions of the Schneiderian membrane using limited cone beam computed tomography (CBCT) in individuals referred for dental implant surgery, and to determine factors influencing the mucosal thickness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A minimal marginal bone loss around implants during early healing has been considered acceptable. However, the preservation of the marginal bone is related to soft tissue stability and esthetics. Implant designs and surfaces were evaluated to determine their impact on the behavior of the crestal bone. The purpose of this study is to evaluate histologic marginal bone level changes around early loaded, chemically modified, sandblasted acid-etched-surfaced implants with a machined collar (MC) or no MC (NMC).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Implants made of commercially pure titanium (cpTi) are widely and successfully used in dentistry. For certain indications, diameter-reduced Ti alloy implants with improved mechanical strength are highly desirable. The aim was to compare the osseointegration of titanium-zirconium (TiZr) and cpTi implants with a modified sandblasted and acid-etched (SLActive) surface and with a Ti6Al4V alloy that was sand-blasted and acid-washed. Cylindrical implants with two, 0.75 mm deep, circumferential grooves were placed in the maxilla of miniature pigs and allowed to heal for 1, 2, 4 and 8 weeks. Undecalcified toluidine blue-stained ground sections were produced. Surface topography, area fraction of tissue components, and bone-to-implant contact (BIC) were determined. All materials showed significantly different surface roughness parameters. The amount of new bone within the implant grooves increased over time, without significant differences between materials. However, BIC values were significantly related to the implant material and the healing period. For TiZr and cpTi implants, the BIC increased over time, reaching values of 59.38 % and 76.15 % after 2 weeks, and 74.50 % and 84.67 % after 8 weeks, respectively. In contrast, the BIC for Ti6Al4V implants peaked with 42.29 % after 2 weeks followed by a decline to 28.60 % at 8 weeks. Significantly more surface was covered by multinucleated giant cells on Ti6Al4V implants after 4 and 8 weeks. In conclusion, TiZr and cpTi implants showed faster osseointegration than Ti6Al4V implants. Both chemistry and surface topography might have influenced the results. The use of diameter-reduced TiZr implants in more challenging clinical situations warrants further documentation in long-term clinical studies.