56 resultados para INTERNAL MAMMARY ARTERY
Resumo:
OBJECTIVE: Nitric oxide (NO) inhibits thrombus formation, vascular contraction, and smooth muscle cell proliferation. We investigated whether NO release is enhanced after endothelial NO synthase (eNOS) gene transfer in atherosclerotic human carotid artery ex vivo. METHODS AND RESULTS: Western blotting and immunohistochemistry revealed that transduction enhanced eNOS expression; however, neither nitrite production nor NO release measured by porphyrinic microsensor was altered. In contrast, transduction enhanced NO production in non-atherosclerotic rat aorta and human internal mammary artery. In transduced carotid artery, calcium-dependent eNOS activity was minimal and did not differ from control conditions. Vascular tetrahydrobiopterin concentrations did not differ between the experimental groups.Treatment of transduced carotid artery with FAD, FMN, NADPH, L-arginine, and either sepiapterin or tetrahydrobiopterin did not alter NO release. Superoxide formation was similar in transduced carotid artery and control. Treatment of transduced carotid artery with superoxide dismutase (SOD), PEG-SOD, PEG-catalase did not affect NO release. CONCLUSIONS: eNOS transduction in atherosclerotic human carotid artery results in high expression without any measurable activity of the recombinant protein. The defect in the atherosclerotic vessels is neither caused by cofactor deficiency nor enhanced NO breakdown. Since angioplasty is performed in atherosclerotic arteries,eNOS gene therapy is unlikely to provide clinical benefit.
Resumo:
OBJECTIVE: Flow mismatch between the supplying artery and the myocardial perfusion region has been observed in patients with internal thoracic artery grafts. Thus coronary flow changes of arterial (internal thoracic artery grafts) and saphenous (saphenous vein grafts) bypass grafts were studied early and late after coronary artery bypass grafting. METHODS: Thirty patients undergoing elective bypass surgery (internal thoracic artery and saphenous vein grafts) were studied intraoperatively and (17 patients) 3 to 10 months postoperatively. Coronary flow was measured intraoperatively with the transit-time Doppler scanning technique. Postoperatively, flow velocity and coronary flow reserve were determined with the Doppler flow wire technique. Quantitative angiographic analysis was used to determine vessel size for calculation of absolute flow. RESULTS: Intraoperatively, internal thoracic artery graft flow was significantly lower than saphenous vein graft flow (31 +/- 8 vs 58 +/- 29 mL/min, P < .01). Postoperatively, internal thoracic artery graft flow increased significantly to 42 +/- 24 mL/min at 3 months and to 56 +/- 30 mL/min (P < .02 vs intraoperative value) at 10 months, respectively. However, saphenous vein graft flow remained unchanged over time (58 +/- 29 to 50 +/- 27 mL/min at 3 months and 46 +/- 27 mL/min at 10 months). Coronary flow reserve was abnormally low intraoperatively in the internal thoracic artery (1.3 +/- 0.3) and saphenous vein (1.6 +/- 0.5) grafts but increased significantly to normal values in both types of graft at follow-up. CONCLUSIONS: Bypass flow of the internal thoracic artery graft is significantly reduced intraoperatively when compared with that of the saphenous vein graft. However, 3 and 10 months after the operation, flow of the internal thoracic artery graft increases significantly and is similar to saphenous vein graft flow. This finding can be explained by an early flow mismatch of the native internal thoracic artery in the presence of a large perfusion territory. During follow-up, there is vascular remodeling of the internal thoracic artery, probably because of endothelium-mediated mechanisms.
Resumo:
BACKGROUND AND PURPOSE The use of thrombolysis in patients with minor neurological deficits and large vessel occlusion is controversial. METHODS We compared the outcome of patients with low National Institutes of Health Stroke Scale (NIHSS) scores and large vessel occlusions between thrombolysed and non-thrombolysed patients. RESULTS 88 (1.7%) of 5312 consecutive patients with acute (within 24 h) ischaemic stroke had occlusions of the internal carotid or the main stem of the middle cerebral artery and baseline NIHSS scores ≤5.47 (53.4%) were treated without thrombolysis, and 41 (46.6%) received intravenous thrombolysis, endovascular therapy or both. Successful recanalisation on MR or CT angiography at 24 h was more often observed in thrombolysed than in non-thrombolysed patients (78.9% versus 10.5%; p<0.001). Neurological deterioration (increase of NIHSS score ≥1 compared to baseline) was observed in 22.7% of non-thrombolysed versus 10.3% of thrombolysed after 24 h (p=0.002), in 33.3% versus 12.5% at hospital discharge (p=0.015) and in 41.4% versus 15% at 3 months (p<0.001). Symptomatic intracerebral haemorrhage occurred in two (asymptomatic in five) thrombolysed and in none (asymptomatic in three) non-thrombolysed. Thrombolysis was an independent predictor of favourable outcome (p=0.030) but not survival (p=0.606) at 3 months. CONCLUSIONS Non-thrombolysed patients with mild deficits and large vessel occlusion deteriorated significantly more often within 3 months than thrombolysed patients. Symptomatic intracerebral haemorrhages occurred in less than 5% of patients in both groups. These data suggest that thrombolysis is safe and effective in these patients. Therefore, randomised trials in patients with large vessel occlusions and mild or rapidly improving symptoms are needed.
Resumo:
We report on the molecular characterization of a microdeletion of approximately 2.5 Mb at 2p11.2 in a female baby with left congenital aural atresia, microtia, and ipsilateral internal carotid artery agenesis. The deletion was characterized by fluorescence in situ hybridization, array comparative genomic hybridization, and whole genome re-sequencing. Among the genes present in the deleted region, we focused our attention on the FOXI3 gene. Foxi3 is a member of the Foxi class of Forkhead transcription factors. In mouse, chicken and zebrafish Foxi3 homologues are expressed in the ectoderm and endoderm giving rise to elements of the jaw as well as external, middle and inner ear. Homozygous Foxi3-/- mice have recently been generated and show a complete absence of the inner, middle, and external ears as well as severe defects in the jaw and palate. Recently, a 7-bp duplication within exon 1 of FOXI3 that produces a frameshift and a premature stop codon was found in hairless dogs. Mild malformations of the outer auditory canal (closed ear canal) and ear lobe have also been noted in a fraction of FOXI3 heterozygote Peruvian hairless dogs. Based on the phenotypes of Foxi3 mutant animals, we propose that FOXI3 may be responsible for the phenotypic features of our patient. Further characterization of the genomic region and the analysis of similar patients may help to demonstrate this point. © 2015 Wiley Periodicals, Inc.
Resumo:
PURPOSE The aim of this study was to compare the diagnostic accuracy of 3D time-of-flight (TOF-MRA) and contrast-enhanced (CE-MRA) magnetic resonance angiography at 3 T for detection and quantification of proximal high-grade stenosis using multidetector computed tomography angiography (MDCTA) as reference standard. METHODS The institutional ethics committee approved this prospective study. A total of 41 patients suspected of having internal carotid artery (ICA) stenosis underwent both MDCTA and MRA. CE-MRA and TOF-MRA were performed using a 3.0-T imager with a dedicated eight-element cervical coil. ICA stenoses were measured according to the North American Symptomatic Carotid Endarterectomy Trial criteria and categorized as 0-25 % (minimal), 25-50 % (mild), 50-69 % (moderate), 70-99 % (high grade), and 100 % (occlusion). Sensitivity and specificity for the detection of high-grade ICA stenoses (70-99 %) and ICA occlusions were determined. In addition, intermodality agreement was assessed with κ-statistics for detection of high-grade ICA stenoses (70-99 %) and ICA occlusions. RESULTS A total of 80 carotid arteries of 41 patients were reviewed. Two previously stented ICAs were excluded from analysis. On MDCTA, 7 ICAs were occluded, 12 ICAs presented with and 63 without a high-grade ICA stenosis (70-99 %). For detecting 70-99 % stenosis, both 3D TOF-MRA and CE-MRA were 91.7 % sensitive and 98.5 % specific, respectively. Both MRA techniques were highly sensitive (100 %), and specific (CE-MRA, 100 %; TOF-MRA, 98.7 %) for the detection of ICA occlusion. However, TOF-MRA misclassified one high-grade stenosis as occlusion. Intermodality agreement for detection of 70-99 % ICA stenoses was excellent between TOF-MRA and CE-MRA [κ = 0.902, 95 % confidence interval (CI) = 0.769-1.000], TOF-MRA and MDCTA (κ = 0.902, 95 % CI = 0.769-1.000), and CE-MRA and MDCTA (κ = 0.902, 95 % CI = 0.769-1.000). CONCLUSION Both 3D TOF-MRA and CE-MRA at 3 T are reliable tools for detecting high-grade proximal ICA stenoses (70-99 %). 3D TOF-MRA might misclassify pseudo-occlusions as complete occlusions. If there are no contraindications for CE-MRA, CE-MRA is recommended as primary MR imaging modality.
Resumo:
BACKGROUND We prospectively investigated temporal and spatial evolution of intramural hematomas in patients with acute spontaneous internal carotid artery dissection using repeated magnetic resonance imaging over six-months. AIM The aim of the present study was to assess dynamic changes of intramural hematoma in patients with acute spontaneous internal carotid artery dissection at multiple follow-up time-points with T1w, PD/T2w, and magnetic resonance angiography. METHODS We performed serial multiparametric magnetic resonance imaging in 10 patients with spontaneous internal carotid artery dissection on admission, at days 1, 3, 7-14 and at months 1·5, 3, and 6. We calculated the volume and extension of the hyperintense intramural hematoma using T1w and PD/T2w fat suppressed sequences and assessed the degree of stenosis due to the hematoma using magnetic resonance angiography. RESULTS Mean interval from symptom onset to first magnetic resonance imaging was two-days (SD 2·7). Two patients presented with ischemic stroke, three with transient ischemic attacks, and five with pain and local symptoms only. Nine patients had a transient increase of the intramural hematoma volume, mainly up to day 10 after symptom onset. Fifty percent had a transient increase in the degree of the internal carotid artery stenosis on MRA, one resulting in a temporary occlusion. Lesions older than one-week were predominantly characterized by a shift from iso- to hyperintese signal on T2w images. At three-month follow-up, intramural hematoma was no longer detectable in 80% of patients and had completely resolved in all patients after six-months. CONCLUSIONS Spatial and temporal dynamics of intramural hematomas after spontaneous internal carotid artery dissection showed an early volume increase with concomitant progression of the internal carotid artery stenosis in 5 of 10 patients. Although spontaneous internal carotid artery dissection overall carries a good prognosis with spontaneous hematoma resorption in all our patients, early follow-up imaging may be considered, especially in case of new clinical symptoms.
Resumo:
PURPOSE Resternotomy for aortic valve replacement in patients with previous coronary artery bypass grafting and an internal mammary artery graft may be a surgical problem. Thus, we are exploring the effect of using rapid prototyping techniques for surgical planning and intraoperative orientation during aortic valve replacement after previous coronary artery bypass grafting (CABG). DESCRIPTION As a proof of concept, we studied a patient who had undergone CABG 5 years earlier. At that time the patient received a left internal mammary artery graft to the left anterior descending artery and a venous graft to the right coronary artery. Now the patient required aortic valve replacement due to symptomatic aortic valve stenosis. The left internal mammary artery bypass and the right coronary artery bypass were patent and showed good flow in the angiography. The patient was examined by 128-slice computed tomography. The image data were visualized and reconstructed. Afterwards, a replica showing the anatomic structures was fabricated using a rapid prototyping machine. EVALUATION Using data derived from 128-slice computed tomography angiography linked to proprietary software, we were able to create three-dimensional reconstructions of the vascular anatomy after the previous CABG. The models were sterilized and taken to the operating theatre for orientation during the surgical procedure. CONCLUSIONS Stereolithographic replicas are helpful for choosing treatment strategies in surgical planning and for intraoperative orientation during reoperations of patients with previous CABG.
Resumo:
The patency rate of radial artery (RA) conduits is considerably lower than that of internal thoracic artery (ITA) grafts and the evidence suggests that this is due to a clinically suspected higher incidence of vasospasm. The aim of this study was, therefore, to compare intraindividually the pharmacological reactivity of RA with that of ITA. Both RA and ITA were taken from the same patients and investigated in parallel. Changes in tone were monitored isometrically on ring preparations from both arteries in organ baths with modified Krebs-Henseleit solution containing 1.25 mm calcium chloride at 1 g passive preload. In intraindividual comparisons maximal receptor-mediated contractile responses to noradrenaline and endothelin-1 and endothelium-dependent acetylcholine-induced relaxant responses revealed no differences between both arteries. By contrast, depolarization-induced contractions to potassium chloride (KCl) appeared to be significantly higher in RA than in ITA. Further analysis, however, revealed that this difference was due to preoperative calcium entry blocker (Ca(2+)eB) therapy. Compared with control tissues, maximal responses to KCl were significantly attenuated in the ITA but unchanged in RA when arteries were obtained from patients with preoperative Ca(2+)eB therapy. The present results suggested that functional responses to pharmacological stimuli of both RA and ITA were quite similar. Preoperative Ca(2+)eB therapy, however, attenuated markedly responses to KCl of the ITA leaving those of RA unchanged. These results, demonstrating a lower sensitivity to Ca(2+)eB of RA, therefore suggested that in addition to Ca(2+)eB other classes of drug may be more effective at reducing the propensity of RA conduits to vasospasm.
Resumo:
PURPOSE: To investigate the impact of filter design on blood flow impairment in the internal carotid artery (ICA) among patients undergoing carotid artery stenting (CAS) using filter-type emboli protection devices (EPD). METHODS: Between July 2003 and March 2007, 115 filter-protected CAS procedures were performed at an academic institution in 107 consecutive patients (78 men; mean age 68 years, range 38-87). The Angioguard, FilterWire EZ, and Spider filters were used in 68 (59%), 32 (28%), and 15 (13%) of cases, respectively. Patient characteristics, procedural and angiographic data, and outcomes were prospectively entered into an electronic database and reviewed retrospectively along with all angiograms. RESULTS: Flow impairment while the filter was in place was observed in 25 (22%) cases. The presumptive reason of flow impairment was filter obstruction in 21 (18%) instances and flow-limiting spasm at the level of the filter in 4 (4%). In all cases, flow was restored after retrieval of the filter. Flow obstruction in the ICA occurred more frequently with Angioguard (22/68; 32.3%) than with FilterWire EZ (2/32; 6.2%) or Spider (1/15; 6.7%; p = 0.004). No flow occurred in 13 (19%) procedures, all of them protected with Angioguard; no patient treated with other devices experienced this event (p = 0.007). Two (8.0%) strokes occurred in procedures associated with flow impairment, while 1 (1.1%) event was observed in the presence of preserved flow throughout the intervention (p = 0.11). CONCLUSION: Flow impairment in the ICA during filter-based CAS is common and related to the type of filter used.
Resumo:
BACKGROUND: Little is known on the performance of newly initiated carotid artery stenting (CAS) programs. The safety of the procedure is being questioned following the publication of the EVA-3S trial, a study criticized for the limited interventional experience required to enroll patients. METHODS: Within a newly started academic CAS program, patient data and outcomes were collected prospectively. The outcomes of the first 100 consecutive patients treated are reported. A CAS-fellowship-trained interventionalist was involved in all procedures. All patients underwent clinical assessment by a neurologist before and after the procedure, and serial ECG and cardiac enzymes were routinely obtained. Primary outcome measures included 30-day major adverse events (MAE), defined as death, stroke, or myocardial infarction, while on follow-up deaths and ipsilateral strokes were added. RESULTS: Between July 2003 and November 2006, 92 patients had a single internal carotid artery treated, while 7 underwent staged bilateral CAS. In one patient, the procedure was aborted prior to lesion treatment. The 30-day MAE rate per procedure was 1.9% (one major and one minor stroke). By a mean follow-up of 16 months (range 2-42 months), one patient had died of refractory heart failure, while one patient had a minor ipsilateral stroke and three had minor contralateral strokes, corresponding to total MAE per patient of 4%. The rate of any stroke or death was 7%. The rate of restenosis >or=50% per lesion by ultrasound was 3.8%. CONCLUSION: This single center experience suggests that it is safe to start a CAS program following dedicated fellowship.
Resumo:
The authors describe the use of the Cardica C-Port xA Distal Anastomosis System to perform an automated, high-flow extracranial-intracranial bypass. The C-Port system has been developed and tested in coronary artery bypass surgery for rapid distal coronary artery anastomoses. Air-powered, it performs an automated end-to-side anastomosis within seconds by nearly simultaneously making an arteriotomy and inserting 13 microclips into the graft and recipient vessel. Intracranial use of the device was first simulated in a cadaver prepared for microsurgical anatomical dissection. The authors used this system in a 43-year-old man who sustained a subarachnoid hemorrhage after being assaulted and was found to have a traumatic pseudoaneurysm of the proximal intracranial internal carotid artery. The aneurysm appeared to be enlarging on serial imaging studies and it was anticipated that a bypass would probably be needed to treat the lesion. An end-to-side bypass was performed with the C-Port system using a saphenous vein conduit extending from the common carotid artery to the middle cerebral artery. The bypass was demonstrated to be patent on intraoperative and postoperative arteriography. The patient had a temporary hyperperfusion syndrome and subsequently made a good neurological recovery. The C-Port system facilitates the performance of a high-flow extracranial-intracranial bypass with short periods of temporary arterial occlusion. Because of the size and configuration of the device, its use is not feasible in all anatomical situations that require a high-flow bypass; however it is a useful addition to the armamentarium of the neurovascular surgeon.
Resumo:
BACKGROUND AND PURPOSE: We set out to investigate the predictors and time course for recanalization of spontaneous dissection of the cervical internal carotid artery (SICAD). METHODS: We prospectively included 249 consecutive patients (mean age, 45+/-11 years) with 268 SICAD. Ultrasound examinations were performed at presentation, during the first month, and then at 3, 6, and 12 months, and clinical follow-ups after 3, 6, and 12 months. RESULTS: Of 268 SICADs, 20 (7.5%) presented with