18 resultados para Hollow flanges


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gebiet: Chirurgie Biomedizintechnik Biophysik Transplantationsmedizin Kardiologie Abstract: OBJECTIVES: – Oxygenation of blood and other physiological solutions are routinely required in fundamental research for both in vitro and in vivo experimentation. However, very few oxygenators with suitable priming volumes (<2-3 ml) are available for surgery in small animals. We have designed a new, miniaturized membrane oxygenator and investigated the oxygen-transfer performance using both buffer and blood perfusates. – – METHODS: – The mini-oxygenator was designed with a central perforated core-tube surrounded by parallel-oriented microporous polypropylene hollow fibres, placed inside a hollow shell with a lateral-luer outlet, and sealed at both extremities. With this design, perfusate is delivered via the core-tube to the centre of the mini-oxygenator, and exits via the luer port. A series of mini-oxygenators were constructed and tested in an in vitro perfusion circuit by monitoring oxygen transfer using modified Krebs-Henseleit buffer or whole porcine blood. Effects of perfusion pressure and temperature over flows of 5-60 ml × min(-1) were assessed. – – RESULTS: – Twelve mini-oxygenators with a mean priming volume of 1.5 ± 0.3 ml were evaluated. With buffer, oxygen transfer reached a maximum of 14.8 ± 1.0 ml O2 × l(-1) (pO2: 450 ± 32 mmHg) at perfusate flow rates of 5 ml × min(-1) and decreased with an increase in perfusate flow to 7.8 ± 0.7 ml ml O2 × l(-1) (pO2: 219 ± 24 mmHg) at 60 ml × min(-1). Similarly, with blood perfusate, oxygen transfer also decreased as perfusate flow increased, ranging from 33 ± 5 ml O2 × l(-1) at 5 ml × min(-1) to 11 ± 2 ml O2 × l(-1) at 60 ml × min(-1). Furthermore, oxygen transfer capacity remained stable with blood perfusion over a period of at least 2 h. – – CONCLUSIONS: – We have developed a new miniaturized membrane oxygenator with an ultra-low priming volume (<2 ml) and adequate oxygenation performance. This oxygenator may be of use in overcoming current limitations in equipment size for effective oxygenation in low-volume perfusion circuits, such as small animal extracorporeal circulation and ex vivo organ perfusion. – – © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes the present-day vegetation, stratigraphy and developmental history of the mire of Egelsee-Moor (Salzburg, Austria; 45°45′N, 13°8.5′E, 700 m a.s.l., 15 ha in area) since the early Late Glacial on the basis of 4 transects with 14 trial borings across the peatland. We present a vegetation map of the mire, a longitudinal section through the peat body based on six cores showing the peat types, overview macrofossil diagrams of six cores showing the local mire development and two pollen diagrams covering the Late Glacial and Holocene. The chronology of the diagrams depends on biostratigraphic dating for the Late Glacial and early Holocene and radiocarbon dating for the remaining Holocene. The northern part of the mire originated through terrestrialisation of nutrient-rich, mostly inundated fen and the southern part through paludification of wet soils. The very small lake of today was a reservoir until recently for providing water-power for timber rafting (‘Holztrift’). The mire vegetation today is a complex of forested parts (mainly planted Pinus sylvestris and Thuja occidentalis, but also spontaneous Picea abies, Betula pubescens and Frangula alnus), reed-lands (Phragmites) and litter meadows (Molinietum, Schoenetum, etc.). The central part has hummock-hollow complexes with regionally rare species of transitional mires (Drosera anglica, D. intermedia, Lycopodiella inundata, Scorpidium scorpioides, Sphagnum platyphyllum, S. subnitens). The results indicate that some of the mid-Holocene sediments may have been removed by the timber-rafting practices, and that water extraction from the hydrological catchment since 1967 has resulted in a partial shift of transitional mire to ombrotrophic bog. The latter potentially endangers the regionally rare species and was used as an argument to stop further water extraction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Lapeyre-Triflo FURTIVA valve aims at combining the favorable hemodynamics of bioprosthetic heart valves with the durability of mechanical heart valves (MHVs). The pivoting region of MHVs is hemodynamically of special interest as it may be a region of high shear stresses, combined with areas of flow stagnation. Here, platelets can be activated and may form a thrombus which in the most severe case can compromise leaflet mobility. In this study we set up an experiment to replicate the pulsatile flow in the aortic root and to study the flow in the pivoting region under physiological hemodynamic conditions (CO = 4.5 L/min / CO = 3.0 L/min, f = 60 BPM). It was found that the flow velocity in the pivoting region could reach values close to that of the bulk flow during systole. At the onset of diastole the three valve leaflets closed in a very synchronous manner within an average closing time of 55 ms which is much slower than what has been measured for traditional bileaflet MHVs. Hot spots for elevated viscous shear stresses were found at the flanges of the housing and the tips of the leaflet ears. Systolic VSS was maximal during mid-systole and reached levels of up to 40 Pa.