24 resultados para Health and Safety at Work


Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION The pentasaccharide fondaparinux is widely approved for prophylaxis and treatment of thromboembolic diseases and therapy of acute coronary syndrome. It is also used off-label in patients with acute, suspected or antecedent heparin-induced thrombocytopenia (HIT). The aim of this prospective observational cohort study was to document fondaparinux' prescription practice, tolerance and therapy safety in a representative mixed German single-centre patient cohort. PATIENTS AND METHODS Between 09/2008 - 04/2009, 231 consecutive patients treated with fondaparinux were enrolled. Medical data were obtained from patient's records. The patients were clinically screened for thrombosis (Wells score), sequelae of HIT (4T's score), and bleeding complications (ISTH-criteria) and subjected to further assessment (i.e. sonography, HIT-diagnostics), if necessary. The mortality rate was assessed 30 days after therapy start. RESULTS Overall, 153/231 patients had a prophylactic, 74/231 patients a therapeutic, and 4/231 patients a successive prophylactic/therapeutic indication. In 11/231 patients fondaparinux was used due to suspected/antecedent HIT, in 5/231 patients due to a previous cutaneous delayed-type hypersensitivity to heparins. Other indications were rare. Three new/progressive thromboses were detected. No cases of HIT, major bleedings, or fatalities occurred. CONCLUSIONS Fondaparinux was well tolerated and was safe in prophylaxis and therapy; prescriptions mostly followed the current approval guidelines and were rarely related to HIT-associated indications (<5% of prescriptions), which is in contrast to previous study results in the U.S. (>94% of prescriptions were HIT-associated). A trend towards an individualised fondaparinux use based on the compound's inherent properties and the patients' risk profiles, i.e., antecedent HIT, bone fractures, heparin allergy, was observed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES The purpose of this study was to compare the 2-year safety and effectiveness of new- versus early-generation drug-eluting stents (DES) according to the severity of coronary artery disease (CAD) as assessed by the SYNTAX (Synergy between Percutaneous Coronary Intervention with Taxus and Cardiac Surgery) score. BACKGROUND New-generation DES are considered the standard-of-care in patients with CAD undergoing percutaneous coronary intervention. However, there are few data investigating the effects of new- over early-generation DES according to the anatomic complexity of CAD. METHODS Patient-level data from 4 contemporary, all-comers trials were pooled. The primary device-oriented clinical endpoint was the composite of cardiac death, myocardial infarction, or ischemia-driven target-lesion revascularization (TLR). The principal effectiveness and safety endpoints were TLR and definite stent thrombosis (ST), respectively. Adjusted hazard ratios (HRs) with 95% confidence intervals (CIs) were calculated at 2 years for overall comparisons, as well as stratified for patients with lower (SYNTAX score ≤11) and higher complexity (SYNTAX score >11). RESULTS A total of 6,081 patients were included in the study. New-generation DES (n = 4,554) compared with early-generation DES (n = 1,527) reduced the primary endpoint (HR: 0.75 [95% CI: 0.63 to 0.89]; p = 0.001) without interaction (p = 0.219) between patients with lower (HR: 0.86 [95% CI: 0.64 to 1.16]; p = 0.322) versus higher CAD complexity (HR: 0.68 [95% CI: 0.54 to 0.85]; p = 0.001). In patients with SYNTAX score >11, new-generation DES significantly reduced TLR (HR: 0.36 [95% CI: 0.26 to 0.51]; p < 0.001) and definite ST (HR: 0.28 [95% CI: 0.15 to 0.55]; p < 0.001) to a greater extent than in the low-complexity group (TLR pint = 0.059; ST pint = 0.013). New-generation DES decreased the risk of cardiac mortality in patients with SYNTAX score >11 (HR: 0.45 [95% CI: 0.27 to 0.76]; p = 0.003) but not in patients with SYNTAX score ≤11 (pint = 0.042). CONCLUSIONS New-generation DES improve clinical outcomes compared with early-generation DES, with a greater safety and effectiveness in patients with SYNTAX score >11.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Drug eluting stents with durable polymers may be associated with hypersensitivity, delayed healing, and incomplete endothelialization, which may contribute to late/very late stent thrombosis and the need for prolonged dual antiplatelet therapy. Bioabsorbable polymers may facilitate stent healing, thus enhancing clinical safety. The SYNERGY stent is a thin-strut, platinum chromium metal alloy platform with an ultrathin bioabsorbable Poly(D,L-lactide-co-glycolide) abluminal everolimus-eluting polymer. We performed a multicenter, randomized controlled trial for regulatory approval to determine noninferiority of the SYNERGY stent to the durable polymer PROMUS Element Plus everolimus-eluting stent. METHODS AND RESULTS Patients (n=1684) scheduled to undergo percutaneous coronary intervention for non-ST-segment-elevation acute coronary syndrome or stable coronary artery disease were randomized to receive either the SYNERGY stent or the PROMUS Element Plus stent. The primary end point of 12-month target lesion failure was observed in 6.7% of SYNERGY and 6.5% PROMUS Element Plus treated subjects by intention-to-treat (P=0.83 for difference; P=0.0005 for noninferiority), and 6.4% in both the groups by per-protocol analysis (P=0.0003 for noninferiority). Clinically indicated revascularization of the target lesion or definite/probable stent thrombosis were observed in 2.6% versus 1.7% (P=0.21) and 0.4% versus 0.6% (P=0.50) of SYNERGY versus PROMUS Element Plus-treated subjects, respectively. CONCLUSIONS In this randomized trial, the SYNERGY bioabsorbable polymer everolimus-eluting stent was noninferior to the PROMUS Element Plus everolimus-eluting stent with respect to 1-year target lesion failure. These data support the relative safety and efficacy of SYNERGY in a broad range of patients undergoing percutaneous coronary intervention. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01665053.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Although recent guidelines recommend the combination of calcium channel blockers (CCBs) and thiazide (-like) diuretics, this combination is not widely used in clinical practice. The aim of this meta-analysis was to assess the efficacy and safety of this combination regarding the following endpoints: all-cause and cardiovascular mortality, myocardial infarction, and stroke. Four studies with a total of 30,791 of patients met the inclusion criteria. The combination CCB/thiazide (-like) diuretic was associated with a significant risk reduction for myocardial infarction (risk ratio [RR], 0.83; 95% confidence interval [CI], 0.73-0.95) and stroke (RR, 0.77; CI, 0.64-0.92) compared with other combinations, whereas it was similarly effective compared with other combinations in reducing the risk of all-cause (RR, 0.89; CI, 0.75-1.06) and cardiovascular (RR, 0.89; CI 0.71-1.10) mortality. Elderly patients with isolated systolic hypertension may particularly benefit from such a combination, since both drug classes have been shown to confer cerebrovascular protection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES To prove non-inferiority of the first non-hormonal vaginal cream in Germany, Vagisan(®) Moisturising Cream (CREAM), compared to a non-hormonal vaginal gel (GEL) for vulvovaginal atrophy (VVA) symptom relief. METHOD This was a 12-week multicenter, open-label, prospective, randomized, two-period, cross-over phase-III trial. The primary endpoint was the cumulative VVA subjective symptom score of the respective treatment period. Secondary endpoints were assessment of single VVA subjective and objective symptoms, VVA objective symptom score, vaginal pH, safety parameters, overall assessment of efficacy, tolerability and evaluation of product properties. In total, 117 women were randomly allocated to either one of the two treatments, each administered for 4 weeks; 92 women were included in the per-protocol analysis (primary analysis). The main outcome measure was cumulative VVA subjective symptom score. RESULTS Regarding VVA symptom relief, results confirmed non-inferiority of CREAM compared to GEL and even indicated superiority of CREAM. Frequency and intensity of subjective symptoms and objective findings were clearly reduced, with CREAM showing better results compared to GEL. Mean VVA objective symptom score significantly decreased; improvement was significantly greater with CREAM. Vaginal pH decreased only following CREAM treatment. Tolerability was superior for CREAM: burning and itching, mostly rated as mild, occurred markedly less often with CREAM than with GEL. Overall satisfaction with treatment efficacy, tolerability and most product properties were rated significantly superior for CREAM. CONCLUSIONS Subjective and objective VVA symptoms were reliably and safely reduced by both non-hormonal topical products. However, efficacy and tolerability of CREAM were shown to be superior to GEL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS Bindarit (BND) is a selective inhibitor of monocyte chemotactic protein-1 (MCP-1/CCL2), which plays an important role in generating intimal hyperplasia. Our aim was to explore the efficacy and safety of bindarit in preventing restenosis following percutaneous coronary intervention. METHODS AND RESULTS A phase II, double-blind, multicentre randomised trial included 148 patients randomised into three arms (BND 600 mg, n=48; BND 1,200 mg, n=49; PLB, n=51). Bindarit was given following PCI and continued for 180 days. Monthly clinical follow-up and six-month coronary angiography were conducted. The primary endpoint was in-segment late loss; the main secondary endpoints were in-stent late loss and major adverse cardiovascular events. Efficacy analysis was carried out on two populations, ITT and PP. There were no significant differences in the baseline characteristics among the three treatment groups. In-segment and in-stent late loss at six months in BND 600, BND 1,200 and PLB were: (ITT 0.54 vs. 0.52 vs. 0.72; p=0.21), (PP 0.46 vs. 0.53 vs. 0.72; p=0.12) and (ITT 0.74 vs. 0.74 vs. 1.05; p=0.01), (PP 0.66 vs. 0.73 vs. 1.06; p=0.003), respectively. The MACE rates at nine months among treatment groups were 20.8% vs. 28.6% vs. 25.5% (p=0.54), respectively. CONCLUSIONS This was a negative study with the primary endpoint not being met. However, significant reduction in the in-stent late loss suggests that bindarit probably exerts a favourable action on the vessel wall following angioplasty. Bindarit was well tolerated with a compliance rate of over 90%. A larger study utilising a loading dose and targeting a specific patient cohort may demonstrate more significant results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND In percutaneous coronary intervention (PCI) patients new-generation drug-eluting stent (DES) has reduced adverse events in comparison to early-generation DES. The aim of the current study was to investigate the long-term clinical efficacy and safety of new-generation DES versus early-generation DES for PCI of unprotected left main coronary artery (uLMCA) disease. METHODS The patient-level data from the ISAR-LEFT MAIN and ISAR-LEFT MAIN 2 randomized trials were pooled. The clinical outcomes of PCI patients assigned to new-generation DES (everolimus- or zotarolimus-eluting stent) versus early-generation DES (paclitaxel- or sirolimus-eluting stent) were studied. The primary endpoint was the composite of death, myocardial infarction (MI), target lesion revascularization and stroke (MACCE, major adverse cardiac and cerebrovascular event). RESULTS In total, 1257 patients were available. At 3 years, the risk of MACCE was comparable between patients assigned to new-generation DES or early-generation DES (28.2 versus 27.5 %, hazard ratio-HR 1.03, 95 % confidence intervals-CI 0.83-1.26; P = 0.86). Definite/probable stent thrombosis was low and comparable between new-generation DES and early-generation DES (0.8 versus 1.6 %, HR 0.52, 95 % CI 0.18-1.57; P = 0.25); in patients treated with new-generation DES no cases occurred beyond 30 days. Diabetes increased the risk of MACCE in patients treated with new-generation DES but not with early-generation DES (P interaction = 0.004). CONCLUSIONS At 3-year follow-up, a PCI with new-generation DES for uLMCA disease shows comparable efficacy to early-generation DES. Rates of stent thrombosis were low in both groups. Diabetes significantly impacts the risk of MACCE at 3 years in patients treated with new-generation DES for uLMCA disease. ClinicalTrials.gov Identifiers: NCT00133237; NCT00598637.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The reporting of outputs from health surveillance systems should be done in a near real-time and interactive manner in order to provide decision makers with powerful means to identify, assess, and manage health hazards as early and efficiently as possible. While this is currently rarely the case in veterinary public health surveillance, reporting tools do exist for the visual exploration and interactive interrogation of health data. In this work, we used tools freely available from the Google Maps and Charts library to develop a web application reporting health-related data derived from slaughterhouse surveillance and from a newly established web-based equine surveillance system in Switzerland. Both sets of tools allowed entry-level usage without or with minimal programing skills while being flexible enough to cater for more complex scenarios for users with greater programing skills. In particular, interfaces linking statistical softwares and Google tools provide additional analytical functionality (such as algorithms for the detection of unusually high case occurrences) for inclusion in the reporting process. We show that such powerful approaches could improve timely dissemination and communication of technical information to decision makers and other stakeholders and could foster the early-warning capacity of animal health surveillance systems.