60 resultados para Health Sciences, Occupational Health and Safety|Health Sciences, Oncology


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Speaking up about patient safety is vital to avoid errors reaching the patient and to improve a culture of safety. This study investigated the prevalence of non-speaking up despite concerns for safety and aimed to identify predictors for withholding voice among healthcare professionals (HCPs) in oncology. A self-administered questionnaire assessed safety concerns, speaking up beliefs and behaviours among nurses and doctors from nine oncology departments. Multiple regression analysis was used to identify predictors for withholding safety concerns. A total of 1013 HCPs returned the completed survey (response rate 65%). Safety concerns were common among responders. Fifty-four per cent reported to recognise their colleagues making potentially harmful errors at least sometimes. A majority of responders reported at least some episodes of withholding concerns about patient safety. Thirty-seven per cent said they remained silent at least once when they had information that might have helped prevent an incident. Respondents believed that a high level of interpersonal, communication and coping skills are necessary to speak up about patient safety issues at their workplace. Higher levels of perceived advocacy for patient safety and psychological safety significantly decreased the frequency of withholding voice. Remaining silent about safety concerns is a common phenomenon in oncology. Improved strategies are needed to support staff in effective communication and make cancer care safer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Among patients with steroid-refractory ulcerative colitis (UC) in whom a first rescue therapy has failed, a second line salvage treatment can be considered to avoid colectomy. AIM: To evaluate the efficacy and safety of second or third line rescue therapy over a one-year period. METHODS: Response to single or sequential rescue treatments with infliximab (5mg/kg intravenously (iv) at week 0, 2, 6 and then every 8weeks), ciclosporin (iv 2mg/kg/daily and then oral 5mg/kg/daily) or tacrolimus (0.05mg/kg divided in 2 doses) in steroid-refractory moderate to severe UC patients from 7 Swiss and 1 Serbian tertiary IBD centers was retrospectively studied. The primary endpoint was the one year colectomy rate. RESULTS: 60% of patients responded to the first rescue therapy, 10% went to colectomy and 30% non-responders were switched to a 2(nd) line rescue treatment. 66% of patients responded to the 2(nd) line treatment whereas 34% failed, of which 15% went to colectomy and 19% received a 3(rd) line rescue treatment. Among those, 50% patients went to colectomy. Overall colectomy rate of the whole cohort was 18%. Steroid-free remission rate was 39%. The adverse event rates were 33%, 37.5% and 30% for the first, second and third line treatment respectively. CONCLUSION: Our data show that medical intervention even with 2(nd) and 3(rd) rescue treatments decreased colectomy frequency within one year of follow up. A longer follow-up will be necessary to investigate whether sequential therapy will only postpone colectomy and what percentage of patients will remain in long-term remission.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION The pentasaccharide fondaparinux is widely approved for prophylaxis and treatment of thromboembolic diseases and therapy of acute coronary syndrome. It is also used off-label in patients with acute, suspected or antecedent heparin-induced thrombocytopenia (HIT). The aim of this prospective observational cohort study was to document fondaparinux' prescription practice, tolerance and therapy safety in a representative mixed German single-centre patient cohort. PATIENTS AND METHODS Between 09/2008 - 04/2009, 231 consecutive patients treated with fondaparinux were enrolled. Medical data were obtained from patient's records. The patients were clinically screened for thrombosis (Wells score), sequelae of HIT (4T's score), and bleeding complications (ISTH-criteria) and subjected to further assessment (i.e. sonography, HIT-diagnostics), if necessary. The mortality rate was assessed 30 days after therapy start. RESULTS Overall, 153/231 patients had a prophylactic, 74/231 patients a therapeutic, and 4/231 patients a successive prophylactic/therapeutic indication. In 11/231 patients fondaparinux was used due to suspected/antecedent HIT, in 5/231 patients due to a previous cutaneous delayed-type hypersensitivity to heparins. Other indications were rare. Three new/progressive thromboses were detected. No cases of HIT, major bleedings, or fatalities occurred. CONCLUSIONS Fondaparinux was well tolerated and was safe in prophylaxis and therapy; prescriptions mostly followed the current approval guidelines and were rarely related to HIT-associated indications (<5% of prescriptions), which is in contrast to previous study results in the U.S. (>94% of prescriptions were HIT-associated). A trend towards an individualised fondaparinux use based on the compound's inherent properties and the patients' risk profiles, i.e., antecedent HIT, bone fractures, heparin allergy, was observed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES The purpose of this study was to compare the 2-year safety and effectiveness of new- versus early-generation drug-eluting stents (DES) according to the severity of coronary artery disease (CAD) as assessed by the SYNTAX (Synergy between Percutaneous Coronary Intervention with Taxus and Cardiac Surgery) score. BACKGROUND New-generation DES are considered the standard-of-care in patients with CAD undergoing percutaneous coronary intervention. However, there are few data investigating the effects of new- over early-generation DES according to the anatomic complexity of CAD. METHODS Patient-level data from 4 contemporary, all-comers trials were pooled. The primary device-oriented clinical endpoint was the composite of cardiac death, myocardial infarction, or ischemia-driven target-lesion revascularization (TLR). The principal effectiveness and safety endpoints were TLR and definite stent thrombosis (ST), respectively. Adjusted hazard ratios (HRs) with 95% confidence intervals (CIs) were calculated at 2 years for overall comparisons, as well as stratified for patients with lower (SYNTAX score ≤11) and higher complexity (SYNTAX score >11). RESULTS A total of 6,081 patients were included in the study. New-generation DES (n = 4,554) compared with early-generation DES (n = 1,527) reduced the primary endpoint (HR: 0.75 [95% CI: 0.63 to 0.89]; p = 0.001) without interaction (p = 0.219) between patients with lower (HR: 0.86 [95% CI: 0.64 to 1.16]; p = 0.322) versus higher CAD complexity (HR: 0.68 [95% CI: 0.54 to 0.85]; p = 0.001). In patients with SYNTAX score >11, new-generation DES significantly reduced TLR (HR: 0.36 [95% CI: 0.26 to 0.51]; p < 0.001) and definite ST (HR: 0.28 [95% CI: 0.15 to 0.55]; p < 0.001) to a greater extent than in the low-complexity group (TLR pint = 0.059; ST pint = 0.013). New-generation DES decreased the risk of cardiac mortality in patients with SYNTAX score >11 (HR: 0.45 [95% CI: 0.27 to 0.76]; p = 0.003) but not in patients with SYNTAX score ≤11 (pint = 0.042). CONCLUSIONS New-generation DES improve clinical outcomes compared with early-generation DES, with a greater safety and effectiveness in patients with SYNTAX score >11.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Drug eluting stents with durable polymers may be associated with hypersensitivity, delayed healing, and incomplete endothelialization, which may contribute to late/very late stent thrombosis and the need for prolonged dual antiplatelet therapy. Bioabsorbable polymers may facilitate stent healing, thus enhancing clinical safety. The SYNERGY stent is a thin-strut, platinum chromium metal alloy platform with an ultrathin bioabsorbable Poly(D,L-lactide-co-glycolide) abluminal everolimus-eluting polymer. We performed a multicenter, randomized controlled trial for regulatory approval to determine noninferiority of the SYNERGY stent to the durable polymer PROMUS Element Plus everolimus-eluting stent. METHODS AND RESULTS Patients (n=1684) scheduled to undergo percutaneous coronary intervention for non-ST-segment-elevation acute coronary syndrome or stable coronary artery disease were randomized to receive either the SYNERGY stent or the PROMUS Element Plus stent. The primary end point of 12-month target lesion failure was observed in 6.7% of SYNERGY and 6.5% PROMUS Element Plus treated subjects by intention-to-treat (P=0.83 for difference; P=0.0005 for noninferiority), and 6.4% in both the groups by per-protocol analysis (P=0.0003 for noninferiority). Clinically indicated revascularization of the target lesion or definite/probable stent thrombosis were observed in 2.6% versus 1.7% (P=0.21) and 0.4% versus 0.6% (P=0.50) of SYNERGY versus PROMUS Element Plus-treated subjects, respectively. CONCLUSIONS In this randomized trial, the SYNERGY bioabsorbable polymer everolimus-eluting stent was noninferior to the PROMUS Element Plus everolimus-eluting stent with respect to 1-year target lesion failure. These data support the relative safety and efficacy of SYNERGY in a broad range of patients undergoing percutaneous coronary intervention. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01665053.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES To prove non-inferiority of the first non-hormonal vaginal cream in Germany, Vagisan(®) Moisturising Cream (CREAM), compared to a non-hormonal vaginal gel (GEL) for vulvovaginal atrophy (VVA) symptom relief. METHOD This was a 12-week multicenter, open-label, prospective, randomized, two-period, cross-over phase-III trial. The primary endpoint was the cumulative VVA subjective symptom score of the respective treatment period. Secondary endpoints were assessment of single VVA subjective and objective symptoms, VVA objective symptom score, vaginal pH, safety parameters, overall assessment of efficacy, tolerability and evaluation of product properties. In total, 117 women were randomly allocated to either one of the two treatments, each administered for 4 weeks; 92 women were included in the per-protocol analysis (primary analysis). The main outcome measure was cumulative VVA subjective symptom score. RESULTS Regarding VVA symptom relief, results confirmed non-inferiority of CREAM compared to GEL and even indicated superiority of CREAM. Frequency and intensity of subjective symptoms and objective findings were clearly reduced, with CREAM showing better results compared to GEL. Mean VVA objective symptom score significantly decreased; improvement was significantly greater with CREAM. Vaginal pH decreased only following CREAM treatment. Tolerability was superior for CREAM: burning and itching, mostly rated as mild, occurred markedly less often with CREAM than with GEL. Overall satisfaction with treatment efficacy, tolerability and most product properties were rated significantly superior for CREAM. CONCLUSIONS Subjective and objective VVA symptoms were reliably and safely reduced by both non-hormonal topical products. However, efficacy and tolerability of CREAM were shown to be superior to GEL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIMS Bindarit (BND) is a selective inhibitor of monocyte chemotactic protein-1 (MCP-1/CCL2), which plays an important role in generating intimal hyperplasia. Our aim was to explore the efficacy and safety of bindarit in preventing restenosis following percutaneous coronary intervention. METHODS AND RESULTS A phase II, double-blind, multicentre randomised trial included 148 patients randomised into three arms (BND 600 mg, n=48; BND 1,200 mg, n=49; PLB, n=51). Bindarit was given following PCI and continued for 180 days. Monthly clinical follow-up and six-month coronary angiography were conducted. The primary endpoint was in-segment late loss; the main secondary endpoints were in-stent late loss and major adverse cardiovascular events. Efficacy analysis was carried out on two populations, ITT and PP. There were no significant differences in the baseline characteristics among the three treatment groups. In-segment and in-stent late loss at six months in BND 600, BND 1,200 and PLB were: (ITT 0.54 vs. 0.52 vs. 0.72; p=0.21), (PP 0.46 vs. 0.53 vs. 0.72; p=0.12) and (ITT 0.74 vs. 0.74 vs. 1.05; p=0.01), (PP 0.66 vs. 0.73 vs. 1.06; p=0.003), respectively. The MACE rates at nine months among treatment groups were 20.8% vs. 28.6% vs. 25.5% (p=0.54), respectively. CONCLUSIONS This was a negative study with the primary endpoint not being met. However, significant reduction in the in-stent late loss suggests that bindarit probably exerts a favourable action on the vessel wall following angioplasty. Bindarit was well tolerated with a compliance rate of over 90%. A larger study utilising a loading dose and targeting a specific patient cohort may demonstrate more significant results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND In percutaneous coronary intervention (PCI) patients new-generation drug-eluting stent (DES) has reduced adverse events in comparison to early-generation DES. The aim of the current study was to investigate the long-term clinical efficacy and safety of new-generation DES versus early-generation DES for PCI of unprotected left main coronary artery (uLMCA) disease. METHODS The patient-level data from the ISAR-LEFT MAIN and ISAR-LEFT MAIN 2 randomized trials were pooled. The clinical outcomes of PCI patients assigned to new-generation DES (everolimus- or zotarolimus-eluting stent) versus early-generation DES (paclitaxel- or sirolimus-eluting stent) were studied. The primary endpoint was the composite of death, myocardial infarction (MI), target lesion revascularization and stroke (MACCE, major adverse cardiac and cerebrovascular event). RESULTS In total, 1257 patients were available. At 3 years, the risk of MACCE was comparable between patients assigned to new-generation DES or early-generation DES (28.2 versus 27.5 %, hazard ratio-HR 1.03, 95 % confidence intervals-CI 0.83-1.26; P = 0.86). Definite/probable stent thrombosis was low and comparable between new-generation DES and early-generation DES (0.8 versus 1.6 %, HR 0.52, 95 % CI 0.18-1.57; P = 0.25); in patients treated with new-generation DES no cases occurred beyond 30 days. Diabetes increased the risk of MACCE in patients treated with new-generation DES but not with early-generation DES (P interaction = 0.004). CONCLUSIONS At 3-year follow-up, a PCI with new-generation DES for uLMCA disease shows comparable efficacy to early-generation DES. Rates of stent thrombosis were low in both groups. Diabetes significantly impacts the risk of MACCE at 3 years in patients treated with new-generation DES for uLMCA disease. ClinicalTrials.gov Identifiers: NCT00133237; NCT00598637.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Scholarly interest in callings is growing, but our understanding of how and when callings relate to career outcomes is incomplete. The present study investigated the possibility that the relationship of calling to work engagement is mediated by work meaningfulness, occupational identity, and occupational self-efficacy – and that this mediation depends on the degree of perceived person-job fit. I examined a highly educated sample of German employees (N=529) in diverse occupations and found support for two of the three hypothesized mediators – work meaningfulness and occupational identity – after controlling for the relation of core self-evaluations to work engagement. Contrary to expectations, the mediated relations of callings to work engagement were not conditional upon the degree of person-job fit. The findings are considered in terms of the pathways through which callings may relate to work engagement and other career development outcomes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During the clinically silent liver stage of a Plasmodium infection the parasite replicates from a single sporozoite into thousands of merozoites. Infection of humans and rodents with large numbers of sporozoites that arrest their development within the liver can cause sterile protection from subsequent infections. Disruption of genes essential for liver stage development of rodent malaria parasites has yielded a number of attenuated parasite strains. A key question to this end is how increased attenuation relates to vaccine efficacy. Here, we generated rodent malaria parasite lines that arrest during liver stage development and probed the impact of multiple gene deletions on attenuation and protective efficacy. In contrast to P. berghei strain ANKA LISP2(-) or uis3(-) single knockout parasites, which occasionally caused breakthrough infections, the double mutant lacking both genes was completely attenuated even when high numbers of sporozoites were administered. However, different vaccination protocols showed that LISP2(-) parasites protected better than uis3(-) and double mutants. Hence, deletion of several genes can yield increased safety but might come at the cost of protective efficacy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Switzerland was the first country to approve certolizumab pegol (Cimzia, CZP) for the treatment of patients with moderate to severe Crohn's disease (CD) in September 2007. This phase IV study aimed to evaluate the efficacy and safety of CZP in a Swiss multicenter cohort of practice-based patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Porfimer is an intravenous (i.v.) injectable photosensitizing agent used in the photodynamic treatment of tumours and of high-grade dysplasia in Barrett's oesophagus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

As the population ages, recurrent ventricular tachycardia (VT) is increasingly encountered in elderly patients with ischemic heart disease. Radiofrequency catheter ablation is useful for reducing VT therapy in patients with an implantable defibrillator. The utility of radiofrequency catheter ablation in the elderly is not well defined.