68 resultados para Hankins, Barry
Resumo:
We characterized changes in the visual behavior of mice in which a loss of the retinal pigment epithelium (RPE) was experimentally induced with intravenous (i.v.) administration of sodium iodate (NaIO3). We compared and correlated these changes with alterations in neural retinal structure and function. RPE loss was induced in 4-6 week old male C57BL/6 mice with an i.v. injection of 1% NaIO3 at three concentrations: 35, 50, or 70 mg/kg. At 1, 3, 7, 14, 21, and 28 days (d) as well as 6 months post injection (PI) a behavioral test was performed in previously trained mice to evaluate visual function. Eye morphology was then assessed for changes in both the RPE and neural retina. NaIO3-induced RPE degeneration was both dose and PI time dependent. Our low dose showed no effects, while our high dose caused the most damage, as did longer PI times at our intermediate dose. Using the intermediate dose, no changes were detectable in either visual behavior or retinal morphology at 1 d PI. However, at 3 d PI visual behavior became abnormal and patchy RPE cell loss was observed. From 7 d PI onward, changes in retinal morphology and visual behavior became more severe. At 6 months PI, no recovery was seen in any of these measures in mice administered the intermediate dose. These results show that NaIO3 dosage and/or time PI can be varied to produce different, yet permanent deficits in retinal morphology and visual function. Thus, this approach should provide a unique system in which the onset and severity of RPE damage, and its consequences can be manipulated. As such, it should be useful in the assessment of rescue or mitigating effects of retinal or stem cell transplantation on visual function.
Resumo:
The objective of this investigation was to determine the fate of thin buccal bone encasing the prominent roots of maxillary anterior teeth following extraction. Resorption of the buccal plate compromises the morphology of the localized edentulous ridge and makes it challenging to place an implant in the optimal position for prosthetic restoration. In addition, the use of Bio-Oss as a bone filler to maintain the form of the edentulous ridge was evaluated. Nine patients were selected for the extraction of 36 maxillary anterior teeth. Nineteen extraction sockets received Bio-Oss, and seventeen sockets received no osteogenic material. All sites were completely covered with soft tissue at the conclusion of surgery. Computerized tomographic scans were made immediately following extraction and then at 30 to 90 days after healing so as to assess the fate of the buccal plates and resultant form of the edentulous sites. The results were assessed by an independent radiologist, with a crest width of 6 mm regarded as sufficient to place an implant. Those sockets treated with Bio-Oss demonstrated a loss of less than 20% of the buccal plate in 15 of 19 test sites (79%). In contrast, 12 of 17 control sockets (71%) demonstrated a loss of more than 20% of the buccal plate. In conclusion, the Bio-Oss test sites outperformed the control sites by a significant margin. No investigator was able to predict which site would be successful without the grafting material even though all were experienced clinicians. This leads to the conclusion that a patient has a significant benefit from receiving grafting materials at the time of extraction.
Resumo:
PURPOSE: To identify groups of early breast cancer patients with substantial risk (10-year risk > 20%) for locoregional failure (LRF) who might benefit from postmastectomy radiotherapy (RT). PATIENTS AND METHODS: Prognostic factors for LRF were evaluated among 6,660 patients (2,588 node-negative patients, 4,072 node-positive patients) in International Breast Cancer Study Group Trials I to IX treated with chemotherapy and/or endocrine therapy, and observed for a median of 14 years. In total, 1,251 LRFs were detected. All patients were treated with mastectomy without RT. RESULTS: No group with 10-year LRF risk exceeding 20% was found among patients with node-negative disease. Among patients with node-positive breast cancer, increasing numbers of uninvolved nodes were significantly associated with decreased risk of LRF, even after adjustment for other prognostic factors. The highest quartile of uninvolved nodes was compared with the lowest quartile. Among premenopausal patients, LRF risk was decreased by 35% (P = .0010); among postmenopausal patients, LRF risk was decreased by 46% (P < .0001). The 10-year cumulative incidence of LRF was 20% among patients with one to three involved lymph nodes and fewer than 10 uninvolved nodes. Age younger than 40 years and vessel invasion were also associated significantly with increased risk. Among patients with node-positive disease, overall survival was significantly greater in those with higher numbers of uninvolved nodes examined (P < .0001). CONCLUSION: Patients with one to three involved nodes and a low number of uninvolved nodes, vessel invasion, or young age have an increased risk of LRF and may be candidates for a similar treatment as those with at least four lymph node metastases.
Resumo:
PURPOSE: To compare two techniques used to create a larger animal model of venous valve incompetence. MATERIALS AND METHODS: To achieve vein dilatation as the primary cause of valve incompetence, common carotid jugular vein (JV) fistulas were created and optional filters were placed into the JV of sheep. Altogether, nine inferior vena cava filters were placed in three sheep in two stages. Six filters were placed caudal to the most caudal JV valve in three sheep and removed 6 weeks later. Then, three filters were placed across the most caudal valve in two sheep with competent valves and removed 3 weeks later. A common carotid artery-JV fistula was created in three sheep and followed-up for 1-3 weeks. Ascending and descending venograms were obtained to determine the JV sizes and function of their valves. The JVs removed at necropsy were studied with venoscopy. RESULTS: Only one of the six JVs with filters caudal to the most caudal valve had incompetent valves after filter removal at 6 weeks. In addition, only one of three JVs with the filter across the valve had incompetent valves after filter removal at 3 weeks. At 1-3-week follow-up of the group with common carotid artery-JV fistula, all three JVs had incompetent valves in the cephalad vein portion, but only one JV had an incompetent valve in its caudal portion. At venoscopy, the incompetent valves showed various degrees of damage ranging from shortening to the destruction of valve leaflets. CONCLUSION: Dilation of the valve annulus with a removable vena cava filter failed to produce valve incompetence. The promising results with the common carotid artery-JV fistula justify further detailed research.
Percutaneous autologous venous valve transplantation: short-term feasibility study in an ovine model
Resumo:
BACKGROUND: Limited experience with bioprosthetic venous valve percutaneously inserted into femoral veins in 15 patients has been promising in short-term results only to show disappointing long-term results. Percutaneous autogenous venous valve (PAVV) transplantation was explored in an ovine model as a possible alternative treatment. METHODS: PAVV consisted of a vein segment containing a valve that was attached to a stent template. The stent templates (n = 9) were designed and hand made in our research laboratory. They consist of two stainless steel square stents 13 or 15 mm in diameter to fit the ovine jugular veins (JV), which ranges from 10 to 15 mm in diameter. A valve-containing segment of JV was harvested and attached with sutures and barbs inside the stent template (n = 9). The valve devices were then manually folded and front loaded inside the 4 cm chamber of the 13F delivery sheath and delivered into the contralateral JV by femoral vein approach. Transplanted PAVVs were studied by immediate and 3 months venograms. Animals were euthanized at 3 months, and jugular veins harvested to perform angioscopic evaluations in vitro. RESULTS: PAVV transplantation was successful in all nine animals. Good valve function with no reflux was observed on immediate and 3 months venograms in eight valves. The transplanted maximal JV diameter ranged from 10.2 mm to 15.4 mm (mean 13.1 +/- 1.5 mm). Venoscopic examination revealed intact, flexible, nonthickened valve leaflets in eight specimens. One PAVV exhibited normal function of one leaflet only; the other cusp was accidentally cut during the transplantation procedure. All transplanted autologous valves were free of thrombus and incorporated into the vein wall of the host vessel. CONCLUSION: This study demonstrated that autogenous valve transplants remained patent and competent without long-term anticoagulation for up to 3 months. The percutaneous autogenous venous valve may provide in future minimally invasive treatment for patients with chronic deep venous insufficiency, but long-term studies need to be done to document its continued patency and function.
Resumo:
PURPOSE: The objective of this study was to investigate the feasibility, outcomes, and amount of small intestinal submucosa (SIS) material needed for embolization of jugular vein (JV) in a swine and sheep model. Our hypothesis was that SIS would cause vein occlusion. MATERIALS AND METHODS: The external JVs (EJV) in swine (n = 6) and JVs in sheep (n = 6) were occluded with SIS fan-folded compressed strips. After percutaneous puncture of the peripheral portion of the EJV or JV, a TIPS set was used to exit their lumen centrally through the skin. The SIS strips were delivered into the isolated venous segment with a pull-through technique via a 10-Fr sheath. Follow-up venograms were done immediately after placement and at the time of sacrifice at 1 or 3 months. Gross examinations focused on the EJV or JV and their surrounding structures. Specimens were evaluated by histology. RESULTS: SIS strip(s) placement was successful in all cases, with immediate vein occlusion seen in 23 of 24 veins (95.8%). All EJVs treated with two strips and all JVs treated with three or four strips remained closed on 1- and 3-month follow-up venograms. Two EJVs treated with one strip and one JV treated with two strips were partially patent on venograms at 1 and 3 months. There has been one skin inflammatory reaction. Necropsies revealed excluded EJV or JV segments with SIS incorporation into the vein wall. Histology demonstrated various stages of SIS remodeling with fibrocytes, fibroblasts, endothelial cells, capillaries, and inflammatory cells. CONCLUSION: We conclude that EJV and JV ablation with SIS strips using percutaneous exit catheterization is feasible and effective in animal models. Further exploration of SIS as vein ablation material is recommended.
Resumo:
PURPOSE: To demonstrate the feasibility of direct angioscopic visualization of an optional inferior vena cava (IVC) filter in situ and during retrieval. MATERIALS AND METHODS: Angioscopy was used for direct visualization of optional IVC filters in six sheep. Cavograms were obtained before the filters were retrieved. After successful filter retrieval, segmental IVC perfusion was performed to evaluate filter retrieval-related damage to the IVC wall. Therefore, all branch vessels were ligated before the IVC segment was flushed with normal saline solution until it was fully distended. Then, the inflow was terminated and the IVC segment observed for deflation. Subsequently, the IVC was harvested en bloc, dissected, and inspected macroscopically. RESULTS: The visibility of IVC filters at angioscopy was excellent. During the retrieval procedure, filter collapse and retraction into the sheath were clearly demonstrated. Angioscopy provided additional information to that obtained with cavography, demonstrating adherent material in three filters. Three filters in place for more than 2 months could not be retrieved because the filter legs were incorporated into the IVC wall. After filter retrieval, there was no perforation at segmental IVC perfusion. At macroscopic inspection of the IVC lumen, a small piece of detached endothelium was found in one animal. CONCLUSION: Angioscopy enabled the direct evaluation of optional IVC filters in situ and during retrieval. Compared with cavography, angioscopy provided additional information about the filter in situ and the retrieval procedure. Future applications of this technique could include studies of filter migration, compression, and clot-trapping efficacy.
Resumo:
Experimental models of tricuspid regurgitation (TR) are needed to study the percutaneous placement of prosthetic atrioventricular valves. The purpose of this study was to develop an appropriate simple and reproducible percutaneous experimental model for creation of tricuspid regurgitation. Tricuspid regurgitation was successfully created through papillary muscle avulsion using a guide-wire loop in seven sheep with regurgitation documented on right ventricular angiograms and a significant increase in heart rate and right atrial pressures. Acute onset of tricuspid regurgitation was poorly tolerated in one animal that died. Autopsy examinations showed avulsion of one papillary muscle in four animals and two papillary muscles in three animals.