33 resultados para H-plane sectoral horns


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recently developed computer applications provide tools for planning cranio-maxillofacial interventions based on 3-dimensional (3D) virtual models of the patient's skull obtained from computed-tomography (CT) scans. Precise knowledge of the location of the mid-facial plane is important for the assessment of deformities and for planning reconstructive procedures. In this work, a new method is presented to automatically compute the mid-facial plane on the basis of a surface model of the facial skeleton obtained from CT. The method matches homologous surface areas selected by the user on the left and right facial side using an iterative closest point optimization. The symmetry plane which best approximates this matching transformation is then computed. This new automatic method was evaluated in an experimental study. The study included experienced and inexperienced clinicians defining the symmetry plane by a selection of landmarks. This manual definition was systematically compared with the definition resulting from the new automatic method: Quality of the symmetry planes was evaluated by their ability to match homologous areas of the face. Results show that the new automatic method is reliable and leads to significantly higher accuracy than the manual method when performed by inexperienced clinicians. In addition, the method performs equally well in difficult trauma situations, where key landmarks are unreliable or absent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Entrapment of the temporal horn is a rare form of isolated hydrocephalus. Standard treatment has not yet been established for this condition, and only a few cases have been reported in the literature. The authors reviewed their prospectively maintained database to report their experience with endoscopic temporal ventriculocisternostomy. All endoscopic operations performed in the Department of Neurosurgery at Ernst Moritz Arndt University between March 1993 and August 2012 were reviewed, and a retrospective chart review of all patients with temporal ventriculocisternostomy was performed. Four patients were identified (3 children and 1 adult). In 3 patients, the condition developed after tumor resection, and in 1 patient it developed due to postmeningitic multiloculated hydrocephalus. In 2 patients, a recurrent trapped temporal horn developed. Refenestration was successful in one of these patients, and dilation in the trigone area with a subsequent stomy of the septum pellucidum was successful in the other. In 1 patient, postoperative meningitis developed, which was treated with antibiotics. Endoscopic temporal ventriculocisternostomy is an option in the treatment of trapped temporal horns. However, more experience is required to recommend it as the treatment of choice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a conceptual prototype model of a focal plane array unit for the STEAMR instrument, highlighting the challenges presented by the required high relative beam proximity of the instrument and focus on how edge-diffraction effects contribute to the array's performance. The analysis was carried out as a comparative process using both PO & PTD and MoM techniques. We first highlight general differences between these computational techniques, with the discussion focusing on diffractive edge effects for near-field imaging reflectors with high truncation. We then present the results of in-depth modeling analyses of the STEAMR focal plane array followed by near-field antenna measurements of a breadboard model of the array. The results of these near-field measurements agree well with both simulation techniques although MoM shows slightly higher complex beam coupling to the measurements than PO & PTD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Histomorphometric evaluation of the buccal aspects of periodontal tissues in rodents requires reproducible alignment of maxillae and highly precise sections containing central sections of buccal roots; this is a cumbersome and technically sensitive process due to the small specimen size. The aim of the present report is to describe and analyze a method to transfer virtual sections of micro-computer tomographic (CT)-generated image stacks to the microtome for undecalcified histological processing and to describe the anatomy of the periodontium in rat molars. A total of 84 undecalcified sections of all buccal roots of seven untreated rats was analyzed. The accuracy of section coordinate transfer from virtual micro-CT slice to the histological slice, right-left side differences and the measurement error for linear and angular measurements on micro-CT and on histological micrographs were calculated using the Bland-Altman method, interclass correlation coefficient and the method of moments estimator. Also, manual alignment of the micro-CT-scanned rat maxilla was compared with multiplanar computer-reconstructed alignment. The supra alveolar rat anatomy is rather similar to human anatomy, whereas the alveolar bone is of compact type and the keratinized gingival epithelium bends apical to join the junctional epithelium. The high methodological standardization presented herein ensures retrieval of histological slices with excellent display of anatomical microstructures, in a reproducible manner, minimizes random errors, and thereby may contribute to the reduction of number of animals needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we report on an optical tolerance analysis of the submillimeter atmospheric multi-beam limb sounder, STEAMR. Physical optics and ray-tracing methods were used to quantify and separate errors in beam pointing and distortion due to reflector misalignment and primary reflector surface deformations. Simulations were performed concurrently with the manufacturing of a multi-beam demonstrator of the relay optical system which shapes and images the beams to their corresponding receiver feed horns. Results from Monte Carlo simulations show that the inserts used for reflector mounting should be positioned with an overall accuracy better than 100 μm (~ 1/10 wavelength). Analyses of primary reflector surface deformations show that a deviation of magnitude 100 μm can be tolerable before deployment, whereas the corresponding variations should be less than 30 μm during operation. The most sensitive optical elements in terms of misalignments are found near the focal plane. This localized sensitivity is attributed to the off-axis nature of the beams at this location. Post-assembly mechanical measurements of the reflectors in the demonstrator show that alignment better than 50 μm could be obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Actors with joint beliefs in a decision-making process form coalitions in order to translate their goals into policy. Yet, coalitions are not formed in an institutional void, but rather institutions confer opportunities and constraints to actors. This paper studies the institutional conditions under which either coalition structures with a dominant coalition or with competing coalitions emerge. It takes into account three conditions, i.e. the degree of federalism of a project, its degree of Europeanisation and the openness of the pre-parliamentary phase of the decision-making process. The cross-sectoral comparison includes the 11 most important decision-making processes in Switzerland between 2001 and 2006 with a fuzzy-set Qualitative Comparative Analysis. Results suggest that Europeanisation or an open pre-parliamentary phase lead to a dominant coalition, whereas only a specific combination of all three conditions is able to explain a structure with competing coalitions.