85 resultados para Greek language, Medieval and late


Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Limited information is available concerning changes in the urodynamic characteristics of orthotopic bladder substitutes with time. Therefore, we compared early and late urodynamic results in patients with an ileal orthotopic bladder substitute combined with an afferent tubular segment. MATERIALS AND METHODS: Of 139 patients surviving at least 5 years after cystoprostatectomy and ileal orthotopic bladder substitution with an afferent tubular segment 119 underwent urodynamic assessment, including 66 at a median of 9 months (early) and 77 at a median of 62 months (late). Of these patients 24 were assessed at each time point. Simultaneously all patients were asked to complete a bladder diary and questionnaire regarding continence for at least 3 days in the week preceding the urodynamic study. RESULTS: Urodynamic parameters were comparable in patients who were evaluated early and late postoperatively. In addition, median values at early and late urodynamic evaluation in the 24 patients with the 2 examinations showed no statistically significant differences for volume at first desire to void (300 vs 333 ml, p = 0.85), pressure at first desire to void (12 vs 13 cm H2O, p = 0.57), maximum cystometric capacity (450 vs 453 ml, p = 0.84), end filling pressure (19 vs 20 cm H2O, p = 0.17), reservoir compliance (25 vs 28 ml/cm H2O, p = 0.58) or post-void residual urine volume (5 vs 15 ml, p = 0.27). CONCLUSIONS: Urodynamic results after 5 years of living with an ileal orthotopic bladder substitute with an afferent tubular segment show grossly unchanged urodynamic characteristics. Patients maintain a reservoir capacity and micturition pattern consistent with a normal life-style. Reservoir pressure remained low, thereby protecting and preserving upper tract function. To achieve these results patients must be regularly followed, and the causes of bacteriuria, increased post-void residual urine and bladder outlet obstruction must be recognized and dealt with accordingly.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: The purpose of this research was to determine the relative safety and efficacy of multiple (> or =2) overlapping Cypher sirolimus-eluting stents (SES) (Johnson ; Johnson, New Brunswick, New Jersey). BACKGROUND: Overlapping coronary stents are common. The periprocedural and late clinical and angiographic consequences of overlapped coronary stents are not clearly defined, particularly for drug-eluting stents. METHODS: All patients enrolled into five clinical trials of the SES were analyzed. Three of these trials were prospective randomized comparisons of the SES to the bare-metal stent (BMS), and two were prospective non-randomized trials of SES-treated patients with historical controls. All clinical and angiographic outcomes in overlap-stent-treated patients were compared by stent type and with single-stent-treated patients for the same stent device. RESULTS: In all, 575 patients with stent overlap (337 SES, 238 BMS) and 1,162 patients with single stents (697 SES, 465 BMS) were analyzed. Stent overlap was associated with a greater late lumen loss in stent and more frequent angiographic restenosis regardless of stent type. Among overlap-stent-treated patients, the SES provided similar magnitude of restenosis benefit as observed for single-stent-treated patients. Overlapped SES was not associated with an increase in myocardial infarction. CONCLUSIONS: The strategy of SES overlap, when required, is both safe and efficacious in reducing restenosis with no increase in the incidence of myocardial infarction or major adverse cardiovascular events, when compared with a bare metal coronary stent prosthesis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Stent thrombosis is a safety concern associated with use of drug-eluting stents. Little is known about occurrence of stent thrombosis more than 1 year after implantation of such stents. METHODS: Between April, 2002, and Dec, 2005, 8146 patients underwent percutaneous coronary intervention with sirolimus-eluting stents (SES; n=3823) or paclitaxel-eluting stents (PES; n=4323) at two academic hospitals. We assessed data from this group to ascertain the incidence, time course, and correlates of stent thrombosis, and the differences between early (0-30 days) and late (>30 days) stent thrombosis and between SES and PES. FINDINGS: Angiographically documented stent thrombosis occurred in 152 patients (incidence density 1.3 per 100 person-years; cumulative incidence at 3 years 2.9%). Early stent thrombosis was noted in 91 (60%) patients, and late stent thrombosis in 61 (40%) patients. Late stent thrombosis occurred steadily at a constant rate of 0.6% per year up to 3 years after stent implantation. Incidence of early stent thrombosis was similar for SES (1.1%) and PES (1.3%), but late stent thrombosis was more frequent with PES (1.8%) than with SES (1.4%; p=0.031). At the time of stent thrombosis, dual antiplatelet therapy was being taken by 87% (early) and 23% (late) of patients (p<0.0001). Independent predictors of overall stent thrombosis were acute coronary syndrome at presentation (hazard ratio 2.28, 95% CI 1.29-4.03) and diabetes (2.03, 1.07-3.83). INTERPRETATION: Late stent thrombosis was encountered steadily with no evidence of diminution up to 3 years of follow-up. Early and late stent thrombosis were observed with SES and with PES. Acute coronary syndrome at presentation and diabetes were independent predictors of stent thrombosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to search for differences in the EEG of first-episode, drug-naive patients having a schizophrenic syndrome which presented different time courses in response to antipsychotic treatment. Thirteen patients who fulfilled DSM-IV diagnosis for schizophrenia or schizophreniform disorder participated in this study. Before beginning antipsychotic treatment, the EEG was recorded. On the same day psychopathological ratings were assessed using the ADMDP system, and again after 7 and 28 days of treatment. The resting EEG (19 leads) was subject to spectral analysis involving power values for six frequency bands. The score for the schizophrenic syndrome was used to divide the patients into two groups: those who displayed a clinically meaningful improvement of this syndrome (reduction of more than 30%) after 7 days of treatment (early responders, ER) and those who showed this improvement after 28 days (late responders. LR). Analysis of variance for repeated measures between ER, LR and their matched controls with the 19 EEG leads yielded highly significant differences for the factor group in the alpha2 and beta2 frequency band. No difference was found between the slow-wave frequency bands. Compared to controls the LR group showed significantly higher alpha2 and beta2 power and, in comparison to the ER group, significantly higher alpha2 power. There were no significant differences between the ER and the control group. These findings point to differences in brain physiology between ER and LR. The implications for diagnosis and treatment are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Surface exposure dating (SED) is an innovative tool already being widely applied for moraine dating and for Late Quaternary glacier and climate reconstruction. Here we present exposure ages of 28 boulders from the Cordillera Real and the Cordillera Cochabamba, Bolivia. Our results indicate that the local Last Glacial Maximum (LGM) in the Eastern Cordilleras occurred at ~22–25 ka and was thus synchronous to the global temperature minimum. We were also able to date several Late Glacial moraines to ~11–13 ka, which likely document lower temperatures and increased precipitation ("Coipasa" humid phase). Additionally, we recognize the existence of older Late Glacial moraines re-calculated to ~15 ka from published cosmogenic nuclide data. Those may coincide with the cold Heinrich 1 event in the North Atlantic region and the pronounced "Tauca" humid phase. We conclude that (i) exposure ages in the tropical Andes may have been overestimated so far due to methodological uncertainties, and (ii) although precipitation plays an important role for glacier mass balances in the tropical Andes, it becomes the dominant forcing for glaciation only in the drier and thus more precipitation-sensitive regions farther west and south.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Flow mismatch between the supplying artery and the myocardial perfusion region has been observed in patients with internal thoracic artery grafts. Thus coronary flow changes of arterial (internal thoracic artery grafts) and saphenous (saphenous vein grafts) bypass grafts were studied early and late after coronary artery bypass grafting. METHODS: Thirty patients undergoing elective bypass surgery (internal thoracic artery and saphenous vein grafts) were studied intraoperatively and (17 patients) 3 to 10 months postoperatively. Coronary flow was measured intraoperatively with the transit-time Doppler scanning technique. Postoperatively, flow velocity and coronary flow reserve were determined with the Doppler flow wire technique. Quantitative angiographic analysis was used to determine vessel size for calculation of absolute flow. RESULTS: Intraoperatively, internal thoracic artery graft flow was significantly lower than saphenous vein graft flow (31 +/- 8 vs 58 +/- 29 mL/min, P < .01). Postoperatively, internal thoracic artery graft flow increased significantly to 42 +/- 24 mL/min at 3 months and to 56 +/- 30 mL/min (P < .02 vs intraoperative value) at 10 months, respectively. However, saphenous vein graft flow remained unchanged over time (58 +/- 29 to 50 +/- 27 mL/min at 3 months and 46 +/- 27 mL/min at 10 months). Coronary flow reserve was abnormally low intraoperatively in the internal thoracic artery (1.3 +/- 0.3) and saphenous vein (1.6 +/- 0.5) grafts but increased significantly to normal values in both types of graft at follow-up. CONCLUSIONS: Bypass flow of the internal thoracic artery graft is significantly reduced intraoperatively when compared with that of the saphenous vein graft. However, 3 and 10 months after the operation, flow of the internal thoracic artery graft increases significantly and is similar to saphenous vein graft flow. This finding can be explained by an early flow mismatch of the native internal thoracic artery in the presence of a large perfusion territory. During follow-up, there is vascular remodeling of the internal thoracic artery, probably because of endothelium-mediated mechanisms.