41 resultados para Fracture fixation, internal
Resumo:
PURPOSE: The purpose of this systematic review was to evaluate horizontal relapse and its causes in bilateral sagittal split advancement osteotomy (BSSO) with rigid internal fixation of different types. MATERIALS AND METHODS: A search of the literature was performed in the databases PubMed, Ovid, Cochrane Library, and Google Scholar Beta. From 488 articles identified, 24 articles were finally included. Six studies were prospective, and 18 were retrospective. The range of postoperative study records was 6 months to 12.7 years. RESULTS: The short-term relapse for bicortical screws was between 1.5% and 32.7%, for miniplates between 1.5% and 18.0%, and for bioresorbable bicortical screws between 10.4% and 17.4%, at point B. The long-term relapse for bicortical screws was between 2.0% and 50.3%, and for miniplates between 1.5% and 8.9%, at point B. CONCLUSIONS: BSSO for mandibular advancement is a good treatment option for skeletal Class II, but seems less stable than BSSO setback in the short and long terms. Bicortical screws of titanium, stainless steel, or bioresorbable material show little difference regarding skeletal stability compared with miniplates in the short term. A greater number of studies with larger skeletal long-term relapse rates were evident in patients treated with bicortical screws instead of miniplates. The etiology of relapse is multifactorial, involving the proper seating of the condyles, the amount of advancement, the soft tissue and muscles, the mandibular plane angle, the remaining growth and remodeling, the skill of the surgeon, and preoperative age. Patients with a low mandibular plane angle have increased vertical relapse, whereas patients with a high mandibular plane angle have more horizontal relapse. Advancements in the range of 6 to 7 mm or more predispose to horizontal relapse. To obtain reliable scientific evidence, further short-term and long-term research into BSSO advancement with rigid internal fixation should exclude additional surgery, ie, genioplasty or maxillary surgery, and include a prospective study or randomized clinical trial design with correlation statistics.
Resumo:
BACKGROUND CONTEXT: Closed reduction and internal fixation by an anterior approach is an established option for operative treatment of displaced Type II odontoid fractures. In elderly patients, however, inadequate screw purchase in osteoporotic bone can result in severe procedure-related complications. PURPOSE: To improve the stability of odontoid fracture screw fixation in the elderly using a new technique that includes injection of polymethylmethacrylat (PMMA) cement into the C2 body. STUDY DESIGN: Retrospective review of hospital and outpatient records as well as radiographs of elderly patients treated in a university hospital department of orthopedic surgery. PATIENT SAMPLE: Twenty-four elderly patients (8 males and 16 females; mean age, 81 years; range, 62-98 years) with Type II fractures of the dens. OUTCOME MEASURES: Complications, cement leakage (symptomatic/asymptomatic), operation time, loss of reduction, pseudarthrosis and revision surgery, patient complaints, return to normal activities, and signs of neurologic complications were all documented. METHODS: After closed reduction and anterior approach to the inferior border of C2, a guide wire is advanced to the tip of the odontoid under biplanar fluoroscopic control. Before the insertion of one cannulated, self-drilling, short thread screws, a 12 gauge Yamshidi cannula is inserted from anterior and 1 to 3 mL of high-viscosity PMMA cement is injected into the anteroinferior portion of the C2 body. During polymerization of the cement, the screws are further inserted using a lag-screw compression technique. The cervical spine then is immobilized with a soft collar for 8 weeks postoperatively. RESULTS: Anatomical reduction of the dens was achieved in all 24 patients. Mean operative time was 64 minutes (40-90 minutes). Early loss of reduction occurred in three patients, but revision surgery was indicated in only one patient 2 days after primary surgery. One patient died within the first eight postoperative weeks, one within 3 months after surgery. In five patients, asymptomatic cement leakage was observed (into the C1-C2 joint in three patients, into the fracture in two). Conventional radiologic follow-up at 2 and 6 months confirmed anatomical healing in 16 of the19 patients with complete follow-up. In two patients, the fractures healed in slight dorsal angulation; one patient developed a asymptomatic pseudarthrosis. All patients were able to resume their pretrauma level of activity. CONCLUSIONS: Cement augmentation of the screw in Type II odontoid fractures in elderly patients is technically feasible in a clinical setting with a low complication rate. This technique may improve screw purchase, especially in the osteoporotic C2 body.
Resumo:
INTRODUCTION Stable reconstruction of proximal femoral (PF) fractures is especially challenging due to the peculiarity of the injury patterns and the high load-bearing requirement. Since its introduction in 2007, the PF-locking compression plate (LCP) 4.5/5.0 has improved osteosynthesis for intertrochanteric and subtrochanteric fractures of the femur. This study reports our early results with this implant. METHODS Between January 2008 and June 2010, 19 of 52 patients (12 males, 7 females; mean age 59 years, range 19-96 years) presenting with fractures of the trochanteric region were treated at the authors' level 1 trauma centre with open reduction and internal fixation using PF-LCP. Postoperatively, partial weight bearing was allowed for all 19 patients. Follow-up included a thorough clinical and radiological evaluation at 1.5, 3, 6, 12, 24, 36 and 48 months. Failure analysis was based on conventional radiological and clinical assessment regarding the type of fracture, postoperative repositioning, secondary fracture dislocation in relation to the fracture constellation and postoperative clinical function (Merle d'Aubigné score). RESULTS In 18 patients surgery achieved adequate reduction and stable fixation without intra-operative complications. In one patient an ad latus displacement was observed on postoperative X-rays. At the third month follow-up four patients presented with secondary varus collapse and at the sixth month follow-up two patients had 'cut-outs' of the proximal fragment, with one patient having implant failure due to a broken proximal screw. Revision surgeries were performed in eight patients, one patient receiving a change of one screw, three patients undergoing reosteosynthesis with implantation of a condylar plate and one patient undergoing hardware removal with secondary implantation of a total hip prosthesis. Eight patients suffered from persistent trochanteric pain and three patients underwent hardware removal. CONCLUSIONS Early results for PF-LCP osteosynthesis show major complications in 7 of 19 patients requiring reosteosynthesis or prosthesis implantation due to secondary loss of reduction or hardware removal. Further studies are required to evaluate the limitations of this device.
Resumo:
Twenty-eight feline pelves (56 hemipelves) were examined in order to identify the location for optimal sacroiliac screw placement in sacroiliac fracture-luxation repair. A drill hole was started on the median plane of the hemipelvis in the centre of the body of the first sacral segment until it penetrated the lateral cortex of the ilial wing, thus providing optimal drill hole placement. The position of the drill hole on the articular surface of the sacral wing and on the lateral surface of the ilial wing was measured. The distance of the drill hole from the cranial margin of the sacral wing was 51% of sacral wing length, just cranial to the crescent shaped hyaline cartilage. The distance from the dorsal margin was 47% of sacral wing height. The drill bit direction has to be adjusted to the cranio-caudal inclination (range 10° to 29°) and dorso-ventral inclination (range 2° to 25°) of the sacral wing. A notch in the cranial edge of the sacral wing was present, with variable position, in 34% of the specimens and is consequently not a useful landmark for sacroiliac screw placement. The drill hole on the lateral surface of the ilium was located in craniocaudal direction at a distance of 69% of sacral tuber length, measured from the cranial dorsal iliac spine. The dorso-ventral position of the drill hole was at a distance of 52% of ilial wing height measured from the sacral tuber. The ventral gluteal line, present in 93% of the cases, is a useful landmark to locate optimal screw hole position on the ilial wing.
Resumo:
INTRODUCTION To present the accuracy of reduction, complications and results two years after open reduction and internal fixation of displaced acetabular fractures involving the anterior column (AC) through the Pararectus approach. Frequencies for conversion to total hip replacement in the early follow up, the clinical outcome in preserved hips, and the need for an extension of the approach (1st window of the ilioinguinal approach) are compared to the literature about the modified Stoppa approach. METHODS Forty-eight patients (mean age 62 years, range: 16–98; 41 male) with displaced acetabular fractures involving the AC (AC: n = 9; transverse fracture: n = 2; AC and hemitransverse: n = 24; both column: n = 13) were treated between 12/2009 and 12/2011 using the Pararectus approach. Surgical data and accuracy of reduction (using computed tomography) were assessed. Patients were routinely followed up at eight weeks, 6, 12 and 24 months postoperatively. Failure was defined as the need for total hip arthroplasty. Twenty-four months postoperatively the outcome was rated according to Matta. RESULTS In four patients there were four intraoperative complications (minor vascular damage in two, small perforations of the peritoneum in two) which were managed intraoperatively. Fracture reduction showed statistically significant decreases (mean ± SD, pre- vs. postoperative, in mm) in “step-offs”: 2.6 ± 1.9 vs. 0.1 ± 0.3, p < 0.001 and “gaps”: 11.2 ± 6.8 vs. 0.7 ± 0.9, p < 0.001. Accuracy of reduction was “anatomical” in 45, “imperfect” in three. Five (13%) from 38 available patients required a total hip arthroplasty. Of 33 patients with a preserved hip the clinical outcome was graded as “excellent” in 13 or “good” in 20; radiographically, 27 were graded as “excellent”, four as “good” and two as “fair”. An extension of the approach was infrequently used (1st window ilioinguinal approach in 2%, mini-incision at the iliac crest in 21%). CONCLUSION In the treatment of acetabular fractures involving the anterior column the Pararectus approach allowed for anatomic restoration with minimal access morbidity. Results obtained by means of the Pararectus approach after two years at least parallel those reported after utilisation of the modified Stoppa approach. In contrast to the modified Stoppa approach, a relevant extension of the Pararectus approach was almost not necessary.
Temporary Internal Fixation for Ligamentous and Osseous Lisfranc Injuries: Outcome and Technical Tip
Resumo:
BACKGROUND Open rather than closed reduction and internal fixation as well as primary definitive arthrodesis are well accepted for ligamentous and osseous Lisfranc injuries. For ligamentous injuries, a better outcome after primary definitive partial arthrodesis has been published. METHODS Of 135 Lisfranc injuries that were treated from 1998 to 2012 with open reduction, temporary internal fixation by screws and plates, and restricted weight bearing in a lower leg cast for 3 months followed by an arch support for another 4 to 6 weeks, 29 ligamentous Lisfranc injuries were available for follow-up. They were compared with 29 osseous Lisfranc injuries matched in age and gender. RESULTS Between the groups, there were no significant differences in average age (39.9 vs 38 years) or in average follow-up time (8.3 vs 9.1 years). Also, no significant differences were seen in the AOFAS midfoot score (84 vs 85.3 points), the FFI pain scale (9.9 vs 14.9 points), SF 36 physical component (56.2 vs 53.9 points), SF 36 mental component (57 vs 56.4 points), or VAS for pain (1.6 vs 1.5 points). The FFI function scale was significantly lower in the ligamentous group (11.6 vs 19.5 points). Radiographically, loss of reduction was recorded 3 times in the ligamentous injuries and 4 times in the osseous injuries. Arthritis was mild/moderate/severe in 5/3/0 ligamentous injuries and in 7/2/1 osseous injuries, requiring 1 definitive secondary Lisfranc arthrodesis in each group. CONCLUSION With longer and conservative postoperative management, open reduction and temporary internal fixation in ligamentous and osseous Lisfranc injuries led to equal medium-term outcome. Inferior outcome in ligamentous injuries was not found. LEVEL OF EVIDENCE Level III, retrospective comparative cohort study.
Resumo:
The aim of this study was to evaluate the stability of Le Fort I maxillary inferior repositioning surgery in patients with a vertical maxillary deficiency at least 6 months after surgery. The electronic databases were searched to identify all articles reporting the long-term effects of one-piece maxillary inferior repositioning with rigid fixation. Methodological quality was evaluated according to 15 criteria related to study design, measurements, and statistical analysis. Two articles were identified, with a total of 22 patients. The maxilla was repositioned inferiorly from a mean 3.2 to 4.5mm in the anterior part and from a mean 0.1 to 1.8mm in the posterior part. At 6 months post-treatment, absolute relapse of a mean 1.6mm was measured for the anterior part of the maxilla and 0.3mm for the posterior part of the maxilla. The stability of maxillary inferior repositioning surgery could not be confirmed due to the small sample size, unclear diagnosis, and potential confounding factors.
Resumo:
Congenital pseudarthrosis of the tibia (CPT) is caused by an ill-defined, segmental disturbance of periosteal bone formation leading to spontaneous bowing, followed by fracture and subsequent pseudarthrosis in the first 2 years of life. The results of conventional treatment modalities (e.g., bracing, internal and external fixation and bone grafting) are associated with high failure rates in terms of persisting pseudarthrosis, malunion and impaired growth. As a more promising alternative, a more aggressive approach, including wide resection of the affected bone, reconstruction with free vascularised fibula grafts from the healthy contralateral leg and stable external fixation at a very early stage has been suggested. Between 1995 and 2007, 10 children (age 12-31 months, median 20 months) suffering from CPT were treated at our institutions according to this principle. Two patients were treated before a fracture had occurred. The length of the fibula graft was 7-9cm. End-to-end anastomoses were performed at the level of the distal tibia stump. The follow-up was 80 months (median, range 12 months to 12 years). Radiologic examination at 6 weeks postoperatively showed normal bone density and structure of the transplanted fibula in all cases and osseous consolidation at 19 of the 20 graft/tibia junctions. One nonunion was sucessfully treated with bone grafting and plate osteosynthesis. Pin-tract infection occurred in three patients. Five children sustained graft fractures that were successfully treated with internal or external fixation. Two patients developed diminished growth of the affected limb or foot; all others had equal limb length and shoe size. At long-term follow-up, tibialisation of the transplant had occurred, and normal gait and physical activities were possible in all children. We conclude that in spite of a relatively high complication rate and the reluctance to perform free flap surgery in infants at this young age, the present concept may successfully prevent the imminent severe sequelae associated with CPT.
Resumo:
Surgical dislocation of the hip in the treatment of acetabular fractures allows the femoral head to be safely displaced from the acetabulum. This permits full intra-articular acetabular and femoral inspection for the evaluation and potential treatment of cartilage lesions of the labrum and femoral head, reduction of the fracture under direct vision and avoidance of intra-articular penetration with hardware. We report 60 patients with selected types of acetabular fracture who were treated using this approach. Six were lost to follow-up and the remaining 54 were available for clinical and radiological review at a mean follow-up of 4.4 years (2 to 9). Substantial damage to the intra-articular cartilage was found in the anteromedial portion of the femoral head and the posterosuperior aspect of the acetabulum. Labral lesions were predominantly seen in the posterior acetabular area. Anatomical reduction was achieved in 50 hips (93%) which was considerably higher than that seen in previous reports. There were no cases of avascular necrosis. Four patients subsequently required total hip replacement. Good or excellent results were achieved in 44 hips (81.5%). The cumulative eight-year survivorship was 89.0% (95% confidence interval 84.5 to 94.1). Significant predictors of poor outcome were involvement of the acetabular dome and lesions of the femoral cartilage greater than grade 2. The functional mid-term results were better than those of previous reports. Surgical dislocation of the hip allows accurate reduction and a predictable mid-term outcome in the management of these difficult injuries without the risk of the development of avascular necrosis.
Resumo:
The most widely accepted treatment for comminuted fractures of the radial head is either the excision or open reduction and internal fixation. The purpose of the present study is to evaluate the value of an 'on-table' reconstruction technique in severely comminuted fractures of the radial head. In this study, two patients with a Mason type-III and four patients with a Mason type-IV radial-head fracture were treated with 'on-table' reconstruction and fixation using low-profile mini-plates. After a mean follow-up of 112 months (47-154 months), the mean elbow motion was 0-6-141 degrees extension flexion with 79 degrees of pronation and 70 degrees of supination. The mean Broberg and Morrey functional rating score was 97.0 points, the Mayo Elbow Performance Index was 99.2 points and the mean Disabilities of the Arm, Shoulder, and Hand (DASH) Outcome Measure score was 1.94 points. One patient had symptoms of degenerative changes, with a slight joint-space narrowing. There were no radiographic signs of devitalisation at final examination. Comminuted fractures of the radial head, which would otherwise require excision, can be successfully treated with an 'on-table' reconstruction technique.
Resumo:
Mason type III fractures of the radial head are treated by open reduction and internal fixation, resection or prosthetic joint replacement. When internal fixation is performed, fixation of the radial head to the shaft is difficult and implant-related complications are common. Furthermore, problems of devascularisation of the radial head can result from fixation of the plate to the radial neck. In a small retrospective study, the treatment of Mason type III fractures with fixation of the radial neck in 13 cases (group 2) was compared with 12 cases where no fixation was performed (group 1). The mean clinical and radiological follow-up was four years (1 to 9). The Broberg-Morrey index showed excellent results in both groups. Degenerative radiological changes were seen more frequently in group 2, and removal of the implant was necessary in seven of 13 cases. Post-operative evaluation of these two different techniques revealed similar ranges of movement and functional scores. We propose that anatomical reconstruction of the radial head without metalwork fixation to the neck is preferable, and the outcome is the same as that achieved with the conventional technique. In addition degenerative changes of the elbow joint may develop less frequently, and implant removal is not necessary.
Resumo:
Delayed fracture healing and non-unions represent rare but severe complications in orthopedic surgery. Further knowledge on the mechanisms of the bone repair process and of the development of a pseudoarthrosis is essential to predict and prevent impaired healing of fractures. The present study aimed at elucidating differences in gene expression during the repair of rigidly and non-rigidly fixed osteotomies. For this purpose, the MouseFix™ and the FlexiPlate™ systems (AO Development Institute, Davos, CH), allowing the creation of well defined osteotomies in mouse femora, were employed. A time course following the healing process of the osteotomy was performed and bones and periimplant tissues were analyzed by high-resolution X-ray, MicroCT and by histology. For the assessment of gene expression, Low Density Arrays (LDA) were done. In animals with rigid fixation, X-ray and MicroCT revealed healing of the osteotomy within 3 weeks. Using the FlexiPlate™ system, the osteotomy was still visible by X-ray after 3 weeks and a stabilizing cartilaginous callus was formed. After 4.5 weeks, the callus was remodeled and the osteotomy was, on a histological level, healed. Gene expression studies revealed levels of transcripts encoding proteins associated with inflammatory processes not to be altered in tissues from bones with rigid and non-rigid fixation, respectively. Levels of transcripts encoding proteins of the extracellular matrix and essential for bone cell functions were not increased in the rigidly fixed group when compared to controls without osteotomy. In the FlexiPlate™ group, levels of transcripts encoding the same set of genes were significantly increased 3 weeks after surgery. Expression of transcripts encoding BMPs and BMP antagonists was increased after 3 weeks in repair tissues from bones fixed with FlexiPlate™, as were inhibitors of the WNT signaling pathways. Little changes only were detected in transcript levels of tissues from rigidly fixed bones. The data of the present study suggest that rigid fixation enables accelerated healing of an experimental osteotomy as compared to non-rigid fixation. The changes in the healing process after non-rigid fixation are accompanied by an increase in the levels of transcripts encoding inhibitors of osteogenic pathways and, probably as a consequence, by temporal changes in bone matrix synthesis.
Resumo:
OBJECTIVE: To report clinical evaluation of the clamp rod internal fixator 4.5/5.5 (CRIF 4.5/5.5) in bovine long-bone fracture repair. STUDY DESIGN: Retrospective study. ANIMALS: Cattle (n=22) with long-bone fractures. METHODS: Records for cattle with long-bone fractures repaired between 1999 and 2004 with CRIF 4.5/5.5 were reviewed. Quality of fracture repair, fracture healing, and clinical outcome were investigated by means of clinical examination, medical records, radiographs, and telephone questionnaire. RESULTS: Successful long-term outcome was achieved in 18 cattle (82%); 4 were euthanatized 2-14 days postoperatively because of fracture breakdowns. Two cattle had movement of clamps on the rod. Moderate to severe callus formation was evident in 11 cattle 6 months postoperatively. CONCLUSIONS: Movement of clamps on the rod was recognized as implant failure unique to the CRIF. This occurred in cattle with poor fracture stability because of an extensive cortical defect. The CRIF system may not be ideal to treat metacarpal/metatarsal fractures because its voluminous size makes skin closure difficult, thereby increasing the risk of postoperative infections. CLINICAL RELEVANCE: CRIF cannot be recommended for repair of complicated long-bone fractures in cattle.
Resumo:
BACKGROUND: Percutaneous Kirschner wire fixation represents the classic treatment for displaced supracondylar humeral fractures in childhood. This type of treatment first requires satisfactory reduction of the fracture. Failure to achieve a satisfactory reduction or inadequate stabilization can result in instability of the fracture fragments, which can result in either an unsatisfactory cosmetic or functional outcome. In our experience, these problems can be overcome with the use of a small lateral external fixator. METHODS: Between 1999 and 2005, thirty-one of 170 Gartland type-III supracondylar humeral fractures were treated with a lateral external fixator. The outcome of treatment was analyzed with regard to limb alignment, elbow movement, cosmetic appearance, and patient satisfaction. RESULTS: In twenty-eight of the thirty-one patients, a satisfactory reduction was achieved with closed methods. All children except one had a normal or good range of movement. The cosmetic result was excellent in all cases. All of the children and their parents stated that they would choose this treatment again. CONCLUSIONS: The use of a small lateral external fixator seems to be a safe alternative for the treatment of displaced supracondylar fractures of the humerus when a closed reduction appears to be unattainable by means of manipulation alone or when sufficient stability is not achieved with standard methods of Kirschner wire fixation.
Resumo:
Pedicle hooks which are used as an anchorage for posterior spinal instrumentation may be subjected to considerable three-dimensional forces. In order to achieve stronger attachment to the implantation site, hooks using screws for additional fixation have been developed. The failure loads and mechanisms of three such devices have been experimentally determined on human thoracic vertebrae: the Universal Spine System (USS) pedicle hook with one screw, a prototype pedicle hook with two screws and the Cotrel-Dubousset (CD) pedicle hook with screw. The USS hooks use 3.2-mm self-tapping fixation screws which pass into the pedicle, whereas the CD hook is stabilised with a 3-mm set screw pressing against the superior part of the facet joint. A clinically established 5-mm pedicle screw was tested for comparison. A matched pair experimental design was implemented to evaluate these implants in constrained (series I) and rotationally unconstrained (series II) posterior pull-out tests. In the constrained tests the pedicle screw was the strongest implant, with an average pull-out force of 1650 N (SD 623 N). The prototype hook was comparable, with an average failure load of 1530 N (SD 414 N). The average pull-out force of the USS hook with one screw was 910 N (SD 243 N), not significantly different to the CD hook's average failure load of 740 N (SD 189 N). The result of the unconstrained tests were similar, with the prototype hook being the strongest device (average 1617 N, SD 652 N). However, in this series the difference in failure load between the USS hook with one screw and the CD hook was significant. Average failure loads of 792 N (SD 184 N) for the USS hook and 464 N (SD 279 N) for the CD hook were measured. A pedicular fracture in the plane of the fixation screw was the most common failure mode for USS hooks.(ABSTRACT TRUNCATED AT 250 WORDS)