26 resultados para Fourth-order methods
Resumo:
We introduce and analyze hp-version discontinuous Galerkin (dG) finite element methods for the numerical approximation of linear second-order elliptic boundary-value problems in three-dimensional polyhedral domains. To resolve possible corner-, edge- and corner-edge singularities, we consider hexahedral meshes that are geometrically and anisotropically refined toward the corresponding neighborhoods. Similarly, the local polynomial degrees are increased linearly and possibly anisotropically away from singularities. We design interior penalty hp-dG methods and prove that they are well-defined for problems with singular solutions and stable under the proposed hp-refinements. We establish (abstract) error bounds that will allow us to prove exponential rates of convergence in the second part of this work.
Resumo:
The goal of this paper is to establish exponential convergence of $hp$-version interior penalty (IP) discontinuous Galerkin (dG) finite element methods for the numerical approximation of linear second-order elliptic boundary-value problems with homogeneous Dirichlet boundary conditions and piecewise analytic data in three-dimensional polyhedral domains. More precisely, we shall analyze the convergence of the $hp$-IP dG methods considered in [D. Schötzau, C. Schwab, T. P. Wihler, SIAM J. Numer. Anal., 51 (2013), pp. 1610--1633] based on axiparallel $\sigma$-geometric anisotropic meshes and $\bm{s}$-linear anisotropic polynomial degree distributions.
Resumo:
The analysis and reconstruction of forensically relevant events, such as traffic accidents, criminal assaults and homicides are based on external and internal morphological findings of the injured or deceased person. For this approach high-tech methods are gaining increasing importance in forensic investigations. The non-contact optical 3D digitising system GOM ATOS is applied as a suitable tool for whole body surface and wound documentation and analysis in order to identify injury-causing instruments and to reconstruct the course of event. In addition to the surface documentation, cross-sectional imaging methods deliver medical internal findings of the body. These 3D data are fused into a whole body model of the deceased. Additional to the findings of the bodies, the injury inflicting instruments and incident scene is documented in 3D. The 3D data of the incident scene, generated by 3D laser scanning and photogrammetry, is also included into the reconstruction. Two cases illustrate the methods. In the fist case a man was shot in his bedroom and the main question was, if the offender shot the man intentionally or accidentally, as he declared. In the second case a woman was hit by a car, driving backwards into a garage. It was unclear if the driver drove backwards once or twice, which would indicate that he willingly injured and killed the woman. With this work, we demonstrate how 3D documentation, data merging and animation enable to answer reconstructive questions regarding the dynamic development of patterned injuries, and how this leads to a real data based reconstruction of the course of event.
Resumo:
This paper presents a firsthand comparative evaluation of three different existing methods for selecting a suitable allograft from a bone storage bank. The three examined methods are manual selection, automatic volume-based registration, and automatic surface-based registration. Although the methods were originally published for different bones, they were adapted to be systematically applied on the same data set of hemi-pelvises. A thorough experiment was designed and applied in order to highlight the advantages and disadvantages of each method. The methods were applied on the whole pelvis and on smaller fragments, thus producing a realistic set of clinical scenarios. Clinically relevant criteria are used for the assessment such as surface distances and the quality of the junctions between the donor and the receptor. The obtained results showed that both automatic methods outperform the manual counterpart. Additional advantages of the surface-based method are in the lower computational time requirements and the greater contact surfaces where the donor meets the recipient.
Resumo:
PURPOSE Therapeutic drug monitoring of patients receiving once daily aminoglycoside therapy can be performed using pharmacokinetic (PK) formulas or Bayesian calculations. While these methods produced comparable results, their performance has never been checked against full PK profiles. We performed a PK study in order to compare both methods and to determine the best time-points to estimate AUC0-24 and peak concentrations (C max). METHODS We obtained full PK profiles in 14 patients receiving a once daily aminoglycoside therapy. PK parameters were calculated with PKSolver using non-compartmental methods. The calculated PK parameters were then compared with parameters estimated using an algorithm based on two serum concentrations (two-point method) or the software TCIWorks (Bayesian method). RESULTS For tobramycin and gentamicin, AUC0-24 and C max could be reliably estimated using a first serum concentration obtained at 1 h and a second one between 8 and 10 h after start of the infusion. The two-point and the Bayesian method produced similar results. For amikacin, AUC0-24 could reliably be estimated by both methods. C max was underestimated by 10-20% by the two-point method and by up to 30% with a large variation by the Bayesian method. CONCLUSIONS The ideal time-points for therapeutic drug monitoring of once daily administered aminoglycosides are 1 h after start of a 30-min infusion for the first time-point and 8-10 h after start of the infusion for the second time-point. Duration of the infusion and accurate registration of the time-points of blood drawing are essential for obtaining precise predictions.
Resumo:
PURPOSE This paper describes the development of a forward planning process for modulated electron radiotherapy (MERT). The approach is based on a previously developed electron beam model used to calculate dose distributions of electron beams shaped by a photon multi leaf collimator (pMLC). METHODS As the electron beam model has already been implemented into the Swiss Monte Carlo Plan environment, the Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA) can be included in the planning process for MERT. In a first step, CT data are imported into Eclipse and a pMLC shaped electron beam is set up. This initial electron beam is then divided into segments, with the electron energy in each segment chosen according to the distal depth of the planning target volume (PTV) in beam direction. In order to improve the homogeneity of the dose distribution in the PTV, a feathering process (Gaussian edge feathering) is launched, which results in a number of feathered segments. For each of these segments a dose calculation is performed employing the in-house developed electron beam model along with the macro Monte Carlo dose calculation algorithm. Finally, an automated weight optimization of all segments is carried out and the total dose distribution is read back into Eclipse for display and evaluation. One academic and two clinical situations are investigated for possible benefits of MERT treatment compared to standard treatments performed in our clinics and treatment with a bolus electron conformal (BolusECT) method. RESULTS The MERT treatment plan of the academic case was superior to the standard single segment electron treatment plan in terms of organs at risk (OAR) sparing. Further, a comparison between an unfeathered and a feathered MERT plan showed better PTV coverage and homogeneity for the feathered plan, with V95% increased from 90% to 96% and V107% decreased from 8% to nearly 0%. For a clinical breast boost irradiation, the MERT plan led to a similar homogeneity in the PTV compared to the standard treatment plan while the mean body dose was lower for the MERT plan. Regarding the second clinical case, a whole breast treatment, MERT resulted in a reduction of the lung volume receiving more than 45% of the prescribed dose when compared to the standard plan. On the other hand, the MERT plan leads to a larger low-dose lung volume and a degraded dose homogeneity in the PTV. For the clinical cases evaluated in this work, treatment plans using the BolusECT technique resulted in a more homogenous PTV and CTV coverage but higher doses to the OARs than the MERT plans. CONCLUSIONS MERT treatments were successfully planned for phantom and clinical cases, applying a newly developed intuitive and efficient forward planning strategy that employs a MC based electron beam model for pMLC shaped electron beams. It is shown that MERT can lead to a dose reduction in OARs compared to other methods. The process of feathering MERT segments results in an improvement of the dose homogeneity in the PTV.
Resumo:
Introduction In our program, simulated patients (SPs) give feedback to medical students in the course of communication skills training. To ensure effective training, quality control of the SPs’ feedback should be implemented. At other institutions, medical students evaluate the SPs’ feedback for quality control (Bouter et al., 2012). Thinking about implementing quality control for SPs’ feedback in our program, we wondered whether the evaluation by students would result in the same scores as evaluation by experts. Methods Consultations simulated by 4th-year medical students with SPs were video taped including the SP’s feedback to the students (n=85). At the end of the training sessions students rated the SPs’ performance using a rating instrument called Bernese Assessment for Role-play and Feedback (BARF) containing 11 items concerning feedback quality. Additionally the videos were evaluated by 3 trained experts using the BARF. Results The experts showed a high interrater agreement when rating identical feedbacks (ICCunjust=0.953). Comparing the rating of students and experts, high agreement was found with regard to the following items: 1. The SP invited the student to reflect on the consultation first, Amin (= minimal agreement) 97% 2. The SP asked the student what he/she liked about the consultation, Amin = 88%. 3. The SP started with positive feedback, Amin = 91%. 4. The SP was comparing the student with other students, Amin = 92%. In contrast the following items showed differences between the rating of experts and students: 1. The SP used precise situations for feedback, Amax (=maximal agreement) 55%, Students rated 67 of SPs’ feedbacks to be perfect with regard to this item (highest rating on a 5 point Likert scale), while only 29 feedbacks were rated this way by the experts. 2. The SP gave precise suggestions for improvement, Amax 75%, 62 of SPs’ feedbacks obtained the highest rating from students, while only 44 of SPs’ feedbacks achieved the highest rating in the view of the experts. 3. The SP speaks about his/her role in the third person, Amax 60%. Students rated 77 feedbacks with the highest score, while experts judged only 43 feedbacks this way. Conclusion Although evaluation by the students was in agreement with that of experts concerning some items, students rated the SPs’ feedback more often with the optimal score than experts did. Moreover it seems difficult for students to notice when SPs talk about the role in the first instead of the third person. Since precision and talking about the role in the third person are important quality criteria of feedback, this result should be taken into account when thinking about students’ evaluation of SPs’ feedback for quality control. Bouter, S., E. van Weel-Baumgarten, and S. Bolhuis. 2012. Construction and Validation of the Nijmegen Evaluation of the Simulated Patient (NESP): Assessing Simulated Patients’ Ability to Role-Play and Provide Feedback to Students. Academic Medicine: Journal of the Association of American Medical Colleges
Resumo:
Currently several thousands of objects are being tracked in the MEO and GEO regions through optical means. The problem faced in this framework is that of Multiple Target Tracking (MTT). In this context both, the correct associations among the observations and the orbits of the objects have to be determined. The complexity of the MTT problem is defined by its dimension S. The number S corresponds to the number of fences involved in the problem. Each fence consists of a set of observations where each observation belongs to a different object. The S ≥ 3 MTT problem is an NP-hard combinatorial optimization problem. There are two general ways to solve this. One way is to seek the optimum solution, this can be achieved by applying a branch-and- bound algorithm. When using these algorithms the problem has to be greatly simplified to keep the computational cost at a reasonable level. Another option is to approximate the solution by using meta-heuristic methods. These methods aim to efficiently explore the different possible combinations so that a reasonable result can be obtained with a reasonable computational effort. To this end several population-based meta-heuristic methods are implemented and tested on simulated optical measurements. With the advent of improved sensors and a heightened interest in the problem of space debris, it is expected that the number of tracked objects will grow by an order of magnitude in the near future. This research aims to provide a method that can treat the correlation and orbit determination problems simultaneously, and is able to efficiently process large data sets with minimal manual intervention.
Resumo:
BACKGROUND Data evaluating the chronological order of appearance of extraintestinal manifestations (EIMs) relative to the time of inflammatory bowel disease (IBD) diagnosis is currently lacking. We aimed to assess the type, frequency, and chronological order of appearance of EIMs in patients with IBD. METHODS Data from the Swiss Inflammatory Bowel Disease Cohort Study were analyzed. RESULTS The data on 1249 patients were analyzed (49.8% female, median age: 40 [interquartile range, 30-51 yr], 735 [58.8%] with Crohn's disease, 483 [38.7%] with ulcerative colitis, and 31 [2.5%] with indeterminate colitis). A total of 366 patients presented with EIMs (29.3%). Of those, 63.4% presented with 1, 26.5% with 2, 4.9% with 3, 2.5% with 4, and 2.7% with 5 EIMs during their lifetime. Patients presented with the following diseases as first EIMs: peripheral arthritis 70.0%, aphthous stomatitis 21.6%, axial arthropathy/ankylosing spondylitis 16.4%, uveitis 13.7%, erythema nodosum 12.6%, primary sclerosing cholangitis 6.6%, pyoderma gangrenosum 4.9%, and psoriasis 2.7%. In 25.8% of cases, patients presented with their first EIM before IBD was diagnosed (median time 5 mo before IBD diagnosis: range, 0-25 mo), and in 74.2% of cases, the first EIM manifested itself after IBD diagnosis (median: 92 mo; range, 29-183 mo). CONCLUSIONS In one quarter of patients with IBD, EIMs appeared before the time of IBD diagnosis. Occurrence of EIMs should prompt physicians to look for potential underlying IBD.
Resumo:
We prove exponential rates of convergence of hp-version discontinuous Galerkin (dG) interior penalty finite element methods for second-order elliptic problems with mixed Dirichlet-Neumann boundary conditions in axiparallel polyhedra. The dG discretizations are based on axiparallel, σ-geometric anisotropic meshes of mapped hexahedra and anisotropic polynomial degree distributions of μ-bounded variation. We consider piecewise analytic solutions which belong to a larger analytic class than those for the pure Dirichlet problem considered in [11, 12]. For such solutions, we establish the exponential convergence of a nonconforming dG interpolant given by local L 2 -projections on elements away from corners and edges, and by suitable local low-order quasi-interpolants on elements at corners and edges. Due to the appearance of non-homogeneous, weighted norms in the analytic regularity class, new arguments are introduced to bound the dG consistency errors in elements abutting on Neumann edges. The non-homogeneous norms also entail some crucial modifications of the stability and quasi-optimality proofs, as well as of the analysis for the anisotropic interpolation operators. The exponential convergence bounds for the dG interpolant constructed in this paper generalize the results of [11, 12] for the pure Dirichlet case.
Resumo:
Four different preparation and counting methods for biochemical varves were compared in order to assess counting errors and to standardize these techniques. The properties of two embedding methods, namely the shock-freeze, freeze-dry and the water-acetone-epoxy-exchange method, are discussed. Varve counts were carried out on fresh sediment and on sediment thin-sections, on the latter by manual and by automated counting using image-analysis software. Counting on fresh sediment and using image-analysis generally underestimated the number of varves, especially in sections with inconspicuous varves. A comparison between multiple varve counts carried out by a single analyst and different analysts showed no significant differences in the mean varve counts.