55 resultados para Flaps (Airplanes)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Reimplantation of cryoconserved autologous bone flaps is a standard procedure after decompressive craniotomies. Aseptic necrosis and resorption are the most frequent complications of this procedure. At present there is no consensus regarding the definition of the relevant extent and indication for surgical revision. The objective of this retrospective analysis was to identify the incidence of bone flap resorption and the optimal duration of follow-up. METHODS Between February 2009 and March 2012, 100 cryoconserved autologous bone flaps were reimplanted at the Department of Neurosurgery, Inselspital Bern. Three patients were not available for follow-up, and five patients died before follow-up. All patients underwent follow-up at 6 weeks and a second follow-up more than 12 months postoperatively. A clinical and CT-based score was developed for judgment of relevance and decision making for surgical revision. RESULTS Mean follow-up period was 21.6 months postoperatively (range: 12 to 47 months); 48.9 % (45/92) of patients showed no signs of bone flap resorption, 20.7 % (19/92) showed minor resorption with no need for surgical revision, and 30.4 % (28/92) showed major resorption (in 4 % of these the bone flap was unstable or collapsed). CONCLUSIONS Aseptic necrosis and resorption of reimplanted autologous bone flaps occurred more frequently in our series of patients than in most reports in the literature. Most cases were identified between 6 and 12 months postoperatively. Clinical observation or CT scans of patients with autologous bone flaps are recommended for at least 12 months. Patient-specific implants may be preferable to autologous bone flaps.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effect of hydrostatic infiltrations for subperichondrial dissection is controversial. Classical textbooks promote it as the "key step in elevating the flaps" or consider its practicability "a mere fable". Moreover, case reports describe fatal side effects. Up to now, experimental tests are missing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors present the long-term results in a series of 44 cases with post-traumatic bone defects solved with muscle-rib flaps, between March 1997 and December 2007. In these cases, we performed 21 serratus anterior-rib flaps (SA-R), 10 latissimus dorsi-rib flaps (LD-R), and 13 LD-SA-R. The flaps were used in upper limb in 18 cases and in lower limb in 26 cases. With an overall immediate success rate of 95.4% (42 of 44 cases) and a primary bone union rate of 97.7% (43 of 44 cases), and despite the few partisans of this method, we consider that this procedure still remains very usefully for small and medium bone defects accompanied by large soft tissue defects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Six techniques not yet widely known or used in the dermatologic surgery of the nails are briefly described. Small-to-medium-sized tumours of the proximal nail fold (PNF) can be excised and the defect repaired with advancement or rotation flaps. A superficial biopsy technique of the matrix for the diagnosis of longitudinal brown streaks in the nail, which allows rapid histological diagnosis of the melanocyte focus to be performed, is described here. Because the excision is very shallow and leaves the morphogenetic connective tissue of the matrix intact, the defect heals without scarring. Laterally positioned nail tumours can be excised in the manner of a wide lateral longitudinal nail biopsy. The defect repair is performed with a bipedicled flap from the lateral aspect of the distal phalanx. Malignant tumours of the nail organ often require its complete ablation. These defects can be covered by a full-thickness skin graft, reversed dermal graft, or cross-finger flap. The surgical correction of a split nail is often difficult. The cicatricial tissue of the matrix and PNF have to be excised and the re-attachment of these wounds prevented. The matrix defect has to be excised and sutured or covered with a free matrix graft taken either from the neighbouring area or from the big toe nail.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Combined extended nerve and soft tissue defects of the upper extremity require nerve reconstruction and adequate soft tissue coverage. This study focuses on the reliability of the free vascularized sural nerve graft combined with a fasciocutaneous posterior calf flap within this indication. An anatomical study was performed on 26 cadaveric lower extremities that had been Thiel fixated and color silicone injected. Dissection of the fasciocutaneous posterior calf flap involved the medial sural nerve and superficial sural artery (SSA) with its septocutaneous perforators, extended laterally to include the lateral cutaneous branch of the sural nerve and continued to the popliteal origin of the vascular pedicle and the nerves. The vessel and nerves diameter were measured with an eyepiece reticle at 4.5× magnification. Length and diameter of the nerves and vessels were carefully assessed and reported in the dissection book. A total of 26 flaps were dissected. The SSA originated from the medial sural artery (13 cases), the popliteal artery (12 cases), or the lateral sural artery (one case). The average size of the SSA was 1.4 ± 0.4 mm. The mean pedicle length before the artery joined the sural nerve was 4.5 ± 1.9 cm. A comitant vein was present in 21 cases with an average diameter of 2.0 ± 0.8 mm, in 5 cases a separate vein needed to be dissected with an average diameter of 3.5 ± 0.4 mm. The mean medial vascularized sural nerve length was 21.2 ± 8.9 cm. Because of inclusion of the vascularized part of the lateral branch of the sural nerve (mean length of 16.7 ± 4.8 cm), a total of 35.0 ± 9.6 cm mean length of vascularized nerve could be gained from each extremity. The free vascularized sural nerve graft combined with a fasciocutaneous posterior calf flap pedicled on the SSA offers a reliable solution for complex tissue and nerve defect. Clin. Anat. 2012. © 2012 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Degree III furcation involvements were surgically created at four first molars in each of three monkeys. Following 6 weeks of healing, full-thickness flaps were elevated. Following 24% EDTA gel conditioning, the defects were treated with one of the following: (1) enamel matrix proteins (EMD), (2) guided tissue regeneration (GTR) or (3) a combination EMD and GTR. The control defects did not receive any treatment. After 5 months of healing, the animals were sacrificed. Three 8 μm thick histological central sections, 100 μm apart, were used for histomorphometric analysis in six zones of each tooth either within the furcation area or on the pristine external surface of the root. In all specimens, new cementum with inserting collagen fibres was formed. Following GTR or GTR + EMD, cementum was formed up to and including the furcation fornix indicating complete regeneration on the defect periphery. Periodontal ligament fibres were less in all four modalities compared to pristine tissues. In the teeth treated with GTR and GTR + EMD a higher volume of bone and periodontal ligament tissues was observed compared to EMD. After 5 months of healing, regenerated tissues presented quantitative differences from the pristine tissues. In the two modalities where GTR alone or combined with EMD was used, the regenerated tissues differed in quantity from the EMD-treated sites.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cranioplasty is a common neurosurgical procedure. Free-hand molding of polymethyl methacrylate (PMMA) cement into complex three-dimensional shapes is often time-consuming and may result in disappointing cosmetic outcomes. Computer-assisted patient-specific implants address these disadvantages but are associated with long production times and high costs. In this study, we evaluated the clinical, radiological, and cosmetic outcomes of a time-saving and inexpensive intraoperative method to mold custom-made implants for immediate single-stage or delayed cranioplasty. Data were collected from patients in whom cranioplasty became necessary after removal of bone flaps affected by intracranial infection, tumor invasion, or trauma. A PMMA replica was cast between a negative form of the patient's own bone flap and the original bone flap with exactly the same shape, thickness, and dimensions. Clinical and radiological follow-up was performed 2 months post-surgery. Patient satisfaction (Odom criteria) and cosmesis (visual analogue scale for cosmesis) were evaluated 1 to 3 years after cranioplasty. Twenty-seven patients underwent intraoperative template-molded patient-specific cranioplasty with PMMA. The indications for cranioplasty included bone flap infection (56%, n = 15), calvarian tumor resection (37%, n = 10), and defect after trauma (7%, n = 2). The mean duration of the molding procedure was 19 ± 7 min. Excellent radiological implant alignment was achieved in 94% of the cases. All (n = 23) but one patient rated the cosmetic outcome (mean 1.4 years after cranioplasty) as excellent (70%, n = 16) or good (26%, n = 6). Intraoperative cast-molded reconstructive cranioplasty is a feasible, accurate, fast, and cost-efficient technique that results in excellent cosmetic outcomes, even with large and complex skull defects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study investigates the influence of 17β-estradiol (E2) on nitric oxide (NO) production in endothelial cell cultures and the effect of topical E2 on the survival of skin flap transplants in a rat model. Human umbilical vein endothelial cells were treated with three different E2 concentrations and nitrite (NO2) concentrations, as well as endothelial nitric oxide synthase (eNOS) protein expressions were analyzed. In vivo, random-pattern skin flaps were raised in female Wistar rats 14 days following ovariectomy and treated with placebo ointment (group 1), E2 as gel (group 2), and E2 via plaster (group 3). Flap perfusion, survival, and NO2 levels were measured on postoperative day 7. In vitro, E2 treatment increased NO2 concentration in cell supernatant and eNOS expression in cell lysates (p < 0.05). In vivo, E2 treated (gel and plaster groups) demonstrated significantly increased skin flap survival compared to the placebo group (p < 0.05). E2 plaster-treated animals exhibited higher NO2 blood levels than placebo (p < 0.05) paralleling the in vitro observations. E2 increases NO production in endothelial cells via eNOS activation. Topical E2 application can significantly increase survival of ischemically challenged skin flaps in a rat model and may augment wound healing in other ischemic situations via activation of NO production.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To reconstruct a forehead defect, a plastic surgeon must be knowledgeable about the neural, vascular, and muscular anatomy. The position of fixed structures such as eyebrows and hairline should be respected. For the past 5 years, we have used double hatchet flaps for reconstruction of relatively large supra-eyebrow and forehead defects. Because this flap does not appear to be among the techniques used by young plastic surgeons, we thought that it would be valuable to report our experience.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To report percutaneous fenestration of aortic dissection flaps to relieve distal ischemia using a novel intravascular ultrasound (IVUS)-guided fenestration device. CASE REPORTS: Two men (47 and 62 years of age) with aortic dissection and intermittent claudication had percutaneous ultrasound-guided fenestration performed under local anesthesia. Using an ipsilateral transfemoral approach, the intimal flap was punctured under real-time IVUS guidance using a needle-catheter combination through which a guidewire was placed across the dissection flap into the false lumen. The fenestration was achieved using balloon catheters of increasing diameter introduced over the guidewire. Stenting of the re-entry was performed in 1 patient to equalize pressure across the dissection membrane in both lumens. The procedures were performed successfully and without complications. In both patients, ankle-brachial indexes improved from 0.76 to 1.07 and from 0.8 to 1.1, respectively. Both patients were without claudication at the 3- and 6-month follow-up examination. CONCLUSION: Percutaneous intravascular ultrasound-guided fenestration and stenting at the level of the iliac artery in aortic dissection patients with claudication is a technically feasible and safe procedure and relieves symptoms.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To retrospectively evaluate our experience with frontal sinus obliteration using hydroxyapatite cement (BoneSource; Stryker Biotech Europe, Montreux, Switzerland) and compare it with fat obliteration over the approximate same period. Frontal sinus obliteration with hydroxyapatite cement represents a new technique for obliteration of the frontal sinus after mucocele resection. METHODS: Exploration of the frontal sinus was performed using bicoronal, osteoplastic flaps, with mucosal removal and duct obliteration with tissue glue and muscle or fascia. Flaps were elevated over the periorbita, and Silastic sheeting was used to protect the BoneSource material from exposure as it dried. The frontal table was replaced when appropriate. RESULTS: Sixteen patients underwent frontal sinus obliteration with fat (fat obliteration group), and 38 patients underwent obliteration with BoneSource (BoneSource group). Fat obliteration failed in 2 patients, who underwent subsequent BoneSource obliteration, and none of the patients in the BoneSource group has required removal of material because of recurrent complications. Frontobasal trauma (26 patients [68%] in the BoneSource group and 9 patients [56%] in the fat obliteration group) was the most common history of mucocele formation in both groups. Major complications in the BoneSource group included 1 patient with skin fistula, which was managed conservatively, and 1 patient with recurrent ethmoiditis, which was managed surgically. Both complications were not directly attributed to the use of BoneSource. Contour deficit of the frontal bone occurred in 1 patient in the fat obliteration group and in none in the BoneSource group. Two patients in the fat obliteration group had donor site complications (hematoma and infection). Thirteen patients in the BoneSource group had at least 1 prior attempt at mucocele drainage, and no statistical relation existed between recurrent surgery and preservation of the anterior table. CONCLUSION: Hydroxyapatite is a safe, effective material to obliterate frontal sinuses infected with mucoceles, with minimal morbidity and excellent postoperative contour.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM: To investigate the significance of the initial stability of dental implants for the establishment of osseointegration in an experimental capsule model for bone augmentation. MATERIAL AND METHODS: Sixteen male rats were used in the study. In each rat, muscle-periosteal flaps were elevated on the lateral aspect of the mandibular ramus on both sides, resulting in exposure of the bone surface. Small perforations were then produced in the ramus. A rigid, hemispherical Teflon capsule with a diameter of 6 mm and a height of 4 mm and with a hole in its middle portion, prepared to fit the circumference of an ITI HC titanium implant of 2.8 mm in diameter, was fixed to the ramus using 4 mini-screws. On one side of the jaw, the implant was placed through the hole in such a way that its apex did not make contact with the mandibular ramus (test). This placement of the implant did not ensure primary stability. On the other side of the jaw, a similar implant was placed through the hole of the capsule in such a way that contact was made between the implant and the surface of the ramus (control). This provided primary stability of the implant. After placement of the implants, the soft tissues were repositioned over the capsules and sutured. After 1, 3, 6 and 9 months, four animals were sacrificed and subjected to histometric analysis. RESULTS: The mean height of direct bone-to-implant contact of implants with primary stability was 38.8%, 52.9%, 64.6% and 81.3% of the implant length at 1, 3, 6 and 9 months, respectively. Of the bone adjacent to the implant surface, 28.1%, 28.9%, 52.6% and 69.6%, respectively, consisted of mineralized bone. At the test implants, no bone-to-implant contact was observed at any observation time or in any of these non-stabilized specimens. CONCLUSION: The findings of the present study indicate that primary implant stability is a prerequisite for successful osseointegration, and that implant instability results in fibrous encapsulation, thus confirming previously made clinical observations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Based on a previous clinical case report in which the pedicled subcostal artery perforator flap allowed for the closure of a large defect of the lumbar region, the present study was designed to investigate the anatomy of the subcostal artery perforator flap and to evaluate its potential for wider clinical use. METHODS: A series of 14 human cadavers was studied and 28 subcostal artery perforator flaps were dissected. The location of the perforator vessel was charted against anatomical landmarks. Measurements included the perforator calibre, pedicle length, and flap size following methylene blue injection. The findings were compared by Doppler sonography in 15 volunteers. RESULTS: The subcostal artery perforator was present in all dissected specimens and in all volunteers. Its calibre measured in mean 2mm. The location was constant at the lateral border of the latissimus dorsi muscle and between 1 and 3cm below the lower rib end. The pedicle length reached a mean of 10.5cm when dissected up to the border of the erector spinae musculature. The vascular supply covered a mean flap size of 10x14cm. The in vivo investigations confirmed the constant perforator location from the anatomical landmarks. CONCLUSION: This anatomical study reveals a considerable potential for the clinical use of the subcostal artery perforator flap for defect coverage in the lumbar area, due to its constant and reliable anatomy. Doppler sonography can be helpful in preoperative assessment of the size and the position of the subcostal perforator, thus allowing for an optimal flap design.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To compare the clinical outcomes of standard, cylindrical, screw-shaped to novel tapered, transmucosal (Straumann Dental implants immediately placed into extraction sockets. Material and methods: In this randomized-controlled clinical trial, outcomes were evaluated over a 3-year observation period. This report deals with the need for bone augmentation, healing events, implant stability and patient-centred outcomes up to 3 months only. Nine centres contributed a total of 208 immediate implant placements. All surgical and post-surgical procedures and the evaluation parameters were discussed with representatives of all centres during a calibration meeting. Following careful luxation of the designated tooth, allocation of the devices was randomly performed by a central study registrar. The allocated SLA titanium implant was installed at the bottom or in the palatal wall of the extraction socket until primary stability was reached. If the extraction socket was >or=1 mm larger than the implant, guided bone regeneration was performed simultaneously (Bio Oss and BioGide. The flaps were then sutured. During non-submerged transmucosal healing, everything was done to prevent infection. At surgery, the need for augmentation and the degree of wound closure was verified. Implant stability was assessed clinically and by means of resonance frequency analysis (RFA) at surgery and after 3 months. Wound healing was evaluated after 1, 2, 6 and 12 weeks post-operatively. RESULTS: The demographic data did not show any differences between the patients receiving either standard cylindrical or tapered implants. All implants yielded uneventful healing with 15% wound dehiscences after 1 week. After 2 weeks, 93%, after 6 weeks 96%, and after 12 weeks 100% of the flaps were closed. Ninety percent of both implant designs required bone augmentation. Immediately after implantation, RFA values were 55.8 and 56.7 and at 3 months 59.4 and 61.1 for cylindrical and tapered implants, respectively. Patient-centred outcomes did not differ between the two implant designs. However, a clear preference of the surgeon's perception for the appropriateness of the novel-tapered implant was evident. CONCLUSIONS: This RCT has demonstrated that tapered or standard cylindrical implants yielded clinically equivalent short-term outcomes after immediate implant placement into the extraction socket.