25 resultados para Error in substance


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The chronological inconsistency in the first book of Matthew of Edessa's Chronicle is well-known. Some of his are dates accurate to the day, while others err by up to 50 years, with no immediately apparent pattern of error. In this talk I will examine some of these chronological puzzles, by untangling the five main themes that run through the book. By demonstrating how these chronological errors may have arisen, and why certain events in the chronicle are dated much more accurately than others, light may be shed on the sources and methodologies that Matthew used to compose his chronicle.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

For more than 15 years, patient safety has been an issue in different domains of medicine. There is evidence for this subject and also a great need for information. First, we should be familiar with the basic terminology such as the relationship between adverse events and errors, and understand the variations of error. In patient management, besides skills and knowledge (evidence-based medicine), the ability (competence) of healthcare professionals to act and react in unexpected situations is key to prevent and treat adverse events. Not only healthcare professionals should be involved in the process but also healthy people in a way that they understand and patients in a way that they are actively involved. This paper will show how a more general view of patient safety can and should be implemented in the daily work of caregivers dealing with dialysis access in different aspects. A key factor to advance in this subject is to be open-minded and sensualized for this topic. The reader should get an idea of how an institution can create a culture of safety.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Studies have shown that the discriminability of successive time intervals depends on the presentation order of the standard (St) and the comparison (Co) stimuli. Also, this order affects the point of subjective equality. The first effect is here called the standard-position effect (SPE); the latter is known as the time-order error. In the present study, we investigated how these two effects vary across interval types and standard durations, using Hellström’s sensation-weighting model to describe the results and relate them to stimulus comparison mechanisms. In Experiment 1, four modes of interval presentation were used, factorially combining interval type (filled, empty) and sensory modality (auditory, visual). For each mode, two presentation orders (St–Co, Co–St) and two standard durations (100 ms, 1,000 ms) were used; half of the participants received correctness feedback, and half of them did not. The interstimulus interval was 900 ms. The SPEs were negative (i.e., a smaller difference limen for St–Co than for Co–St), except for the filled-auditory and empty-visual 100-ms standards, for which a positive effect was obtained. In Experiment 2, duration discrimination was investigated for filled auditory intervals with four standards between 100 and 1,000 ms, an interstimulus interval of 900 ms, and no feedback. Standard duration interacted with presentation order, here yielding SPEs that were negative for standards of 100 and 1,000 ms, but positive for 215 and 464 ms. Our findings indicate that the SPE can be positive as well as negative, depending on the interval type and standard duration, reflecting the relative weighting of the stimulus information, as is described by the sensation-weighting model.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The performance of memory-guided saccades with two different delays (3 and 30 s of memorization) was studied in seven healthy subjects. Double-pulse transcranial magnetic stimulation (dTMS) with an interstimulus interval of 100 ms was applied over the right dorsolateral prefrontal cortex (DLPFC) early (1 s after target presentation) and late (28 s after target presentation). Early stimulation significantly increased in both delays the percentage of error in amplitude (PEA) of contralateral memory-guided saccades compared to the control experiment without stimulation. dTMS applied late in the delay had no significant effect on PEA. Furthermore, we found a significantly smaller effect of early stimulation in the long-delay paradigm. These results suggest a time-dependent hierarchical organization of the spatial working memory with a functional dominance of DLPFC during the early memorization, independent from the memorization delay. For a long memorization delay, however, working memory seems to have an additional, DLPFC-independent component.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The double-echo-steady-state (DESS) sequence generates two signal echoes that are characterized by a different contrast behavior. Based on these two contrasts, the underlying T2 can be calculated. For a flip-angle of 90 degrees , the calculated T2 becomes independent of T1, but with very low signal-to-noise ratio. In the present study, the estimation of cartilage T2, based on DESS with a reduced flip-angle, was investigated, with the goal of optimizing SNR, and simultaneously minimizing the error in T2. This approach was validated in phantoms and on volunteers. T2 estimations based on DESS at different flip-angles were compared with standard multiecho, spin-echo T2. Furthermore, DESS-T2 estimations were used in a volunteer and in an initial study on patients after cartilage repair of the knee. A flip-angle of 33 degrees was the best compromise for the combination of DESS-T2 mapping and morphological imaging. For this flip angle, the Pearson correlation was 0.993 in the phantom study (approximately 20% relative difference between SE-T2 and DESS-T2); and varied between 0.429 and 0.514 in the volunteer study. Measurements in patients showed comparable results for both techniques with regard to zonal assessment. This DESS-T2 approach represents an opportunity to combine morphological and quantitative cartilage MRI in a rapid one-step examination.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The human face is a vital component of our identity and many people undergo medical aesthetics procedures in order to achieve an ideal or desired look. However, communication between physician and patient is fundamental to understand the patient’s wishes and to achieve the desired results. To date, most plastic surgeons rely on either “free hand” 2D drawings on picture printouts or computerized picture morphing. Alternatively, hardware dependent solutions allow facial shapes to be created and planned in 3D, but they are usually expensive or complex to handle. To offer a simple and hardware independent solution, we propose a web-based application that uses 3 standard 2D pictures to create a 3D representation of the patient’s face on which facial aesthetic procedures such as filling, skin clearing or rejuvenation, and rhinoplasty are planned in 3D. The proposed application couples a set of well-established methods together in a novel manner to optimize 3D reconstructions for clinical use. Face reconstructions performed with the application were evaluated by two plastic surgeons and also compared to ground truth data. Results showed the application can provide accurate 3D face representations to be used in clinics (within an average of 2 mm error) in less than 5 min.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Individuals with type 1 diabetes (T1D) have to count the carbohydrates (CHOs) of their meal to estimate the prandial insulin dose needed to compensate for the meal’s effect on blood glucose levels. CHO counting is very challenging but also crucial, since an error of 20 grams can substantially impair postprandial control. Method: The GoCARB system is a smartphone application designed to support T1D patients with CHO counting of nonpacked foods. In a typical scenario, the user places a reference card next to the dish and acquires 2 images with his/her smartphone. From these images, the plate is detected and the different food items on the plate are automatically segmented and recognized, while their 3D shape is reconstructed. Finally, the food volumes are calculated and the CHO content is estimated by combining the previous results and using the USDA nutritional database. Results: To evaluate the proposed system, a set of 24 multi-food dishes was used. For each dish, 3 pairs of images were taken and for each pair, the system was applied 4 times. The mean absolute percentage error in CHO estimation was 10 ± 12%, which led to a mean absolute error of 6 ± 8 CHO grams for normal-sized dishes. Conclusion: The laboratory experiments demonstrated the feasibility of the GoCARB prototype system since the error was below the initial goal of 20 grams. However, further improvements and evaluation are needed prior launching a system able to meet the inter- and intracultural eating habits.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We present successful 81 Kr-Kr radiometric dating of ancient polarice. Krypton was extracted from the air bubbles in four∼350-kg polar ice samples from Taylor Glacier in the McMurdo Dry Valleys, Antarctica, and dated using Atom Trap Trace Analysis (ATTA). The 81 Kr radiometric ages agree with independent age estimates obtained from stratigraphic dating techniques with a mean abso-lute age offset of 6±2.5 ka. Our experimental methods and sampling strategy are validated by (i) 85 Kr and 39 Ar analyses that show the samples to be free of modern air contamination and (ii)air content measurements that show the ice did not experience gas loss. We estimate the error in the 81 Kr ages due to past geomagnetic variability to be below 3 ka. We show that ice from the previous interglacial period (Marine Isotope Stage 5e, 130–115 ka before present) can be found in abundance near the surface of Taylor Glacier. Our study paves the way for reliable radiometric dating of ancient ice in blue ice areas and margin sites where large samples are available, greatly enhancing their scientific value as archives of old ice and meteorites. At present, ATTA 81Kr analysis requires a 40–80-kg ice sample; as sample requirements continue to decrease, 81 Kr dating of ice cores is a future possibility.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The concentrations of chironomid remains in lake sediments are very variable and, therefore, chironomid stratigraphies often include samples with a low number of counts. Thus, the effect of low count sums on reconstructed temperatures is an important issue when applying chironomid‐temperature inference models. Using an existing data set, we simulated low count sums by randomly picking subsets of head capsules from surface‐sediment samples with a high number of specimens. Subsequently, a chironomid‐temperature inference model was used to assess how the inferred temperatures are affected by low counts. The simulations indicate that the variability of inferred temperatures increases progressively with decreasing count sums. At counts below 50 specimens, a further reduction in count sum can cause a disproportionate increase in the variation of inferred temperatures, whereas at higher count sums the inferences are more stable. Furthermore, low count samples may consistently infer too low or too high temperatures and, therefore, produce a systematic error in a reconstruction. Smoothing reconstructed temperatures downcore is proposed as a possible way to compensate for the high variability due to low count sums. By combining adjacent samples in a stratigraphy, to produce samples of a more reliable size, it is possible to assess if low counts cause a systematic error in inferred temperatures.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Tokai-to-Kamioka (T2K) neutrino experiment measures neutrino oscillations by using an almost pure muon neutrino beam produced at the J-PARC accelerator facility. The T2K muon monitor was installed to measure the direction and stability of the muon beam which is produced together with the muon neutrino beam. The systematic error in the muon beam direction measurement was estimated, using data and MC simulation, to be 0.28 mrad. During beam operation, the proton beam has been controlled using measurements from the muon monitor and the direction of the neutrino beam has been tuned to within 0.3 mrad with respect to the designed beam-axis. In order to understand the muon beam properties, measurement of the absolute muon yield at the muon monitor was conducted with an emulsion detector. The number of muon tracks was measured to be (4.06 ± 0.05) × 10⁴ cm⁻² normalized with 4 × 10¹¹protons on target with 250 kA horn operation. The result is in agreement with the prediction which is corrected based on hadron production data.