57 resultados para Distal nephron
Resumo:
This study sought to investigate in vivo the vascular response at the proximal and distal edges of the second-generation ABSORB everolimus-eluting bioresorbable vascular scaffold (BVS).
Resumo:
Patients with critical limb ischaemia (CLI) are usually elderly and suffer from several co-morbidities. The goal of surveillance after both endovascular and surgical revascularization for CLI is not only the protection of re-established distal perfusion and sustained ambulation but also the reduction of systemic atherothrombotic risk and mortality by ensuring continued best medical care. However, preferred format and rhythm of structured follow-up programs have remained controversial, mainly because of lack of compelling evidence. This review aims to summarize and to appraise available information critically. Thereby, it underlines the importance of systematic surveillance after both surgical and endovascular revascularization for CLI. Recent European guidelines are considered and areas of uncertainty are highlighted and discussed. According to currently available literature and recent guidelines, the early duplex scan is justified in all patients undergoing endovascular or surgical distal revascularization for CLI. There is no best level evidence supporting continued long term duplex surveillance of revascularizations with normal findings at early duplex scan, whereas those patients with abnormal early duplex scan or high risk revacularization are likely to benefit from continued duplex surveillance. Regular clinical follow-up is suggested and clinical deterioration should trigger duplex scanning to ensure revascularization patency.
Resumo:
Distal oesophageal spasm is a rare and under-investigated motility abnormality. Recent studies indicate effective bolus transit in varying percentages of distal oesophageal spasm patients.
Resumo:
OBJECTIVES: We sought to compare the diagnostic performance of screen-film radiography, storage-phosphor radiography, and a flat-panel detector system in detecting forearm fractures and to classify distal radius fractures according to the Müller-AO and Frykman classifications compared with the true extent, depicted by anatomic preparation. MATERIALS AND METHODS: A total of 71 cadaver arms were fractured in a material testing machine creating different fractures of the radius and ulna as well as of the carpal bones. Radiographs of the complete forearm were evaluated by 3 radiologists, and anatomic preparation was used as standard of reference in a receiver operating curve analysis. RESULTS: The highest diagnostic performance was obtained for the detection of distal radius fractures with area under the receiver operating curve (AUC) values of 0.959 for screen-film radiography, 0.966 for storage-phosphor radiography, and 0.971 for the flat-panel detector system (P > 0.05). Exact classification was slightly better for the Frykman (kappa values of 0.457-0.478) compared with the Müller-AO classification (kappa values of 0.404-0.447), but agreement can be considered as moderate for both classifications. CONCLUSIONS: The 3 imaging systems showed a comparable diagnostic performance in detecting forearm fractures. A high diagnostic performance was demonstrated for distal radius fractures and conventional radiography can be routinely performed for fracture detection. However, compared with anatomic preparation, depiction of the true extent of distal radius fractures was limited and the severity of distal radius fractures tends to be underestimated.
Resumo:
Clinically relevant fistula after distal pancreatic resection occurs in 5-30% of patients, prolonging recovery and considerably increasing in-hospital stay and costs. We tested whether routine drainage of the pancreatic stump into a Roux-en-Y limb after distal pancreatic resection decreased the incidence of fistula. From October 2001, data of all patients undergoing pancreatic distal resection were entered in a prospective database. From June 2003 after resection, the main pancreatic duct and the pancreatic stump were oversewn, and in addition, anastomosed into a jejunal Roux-en-Y limb by a single-layer suture (n = 23). A drain was placed near the anastomosis, and all patients received octreotide for 5-7 days postoperatively. The volume of the drained fluid was registered daily, and concentration of amylase was measured and recorded every other day. Patient demographics, hospital stay, pancreatic fistula incidence (> or =30 ml amylase-rich fluid/day on/after postoperative day 10), perioperative morbidity, and follow-up after discharge were compared with our initial series of patients (treated October 2001-May 2003) who underwent oversewing only (n = 20). Indications, patient demographics, blood loss, and tolerance of an oral diet were similar. There were four (20%) pancreatic fistulas in the "oversewn" group and none in the anastomosis group (p < 0.05). Nonsurgical morbidity, in-hospital stay, and follow-up were comparable in both groups.
Resumo:
This paper presents a novel variable decomposition approach for pose recovery of the distal locking holes using single calibrated fluoroscopic image. The problem is formulated as a model-based optimal fitting process, where the control variables are decomposed into two sets: (a) the angle between the nail axis and its projection on the imaging plane, and (b) the translation and rotation of the geometrical model of the distal locking hole around the nail axis. By using an iterative algorithm to find the optimal values of the latter set of variables for any given value of the former variable, we reduce the multiple-dimensional model-based optimal fitting problem to a one-dimensional search along a finite interval. We report the results of our in vitro experiments, which demonstrate that the accuracy of our approach is adequate for successful distal locking of intramedullary nails.
Resumo:
PURPOSE: To evaluate and compare the efficacy of proximal versus distal embolus protection devices (EPD) during carotid artery angioplasty/stenting (CAS) based on diffusion-weighted magnetic resonance imaging (DW-MRI). METHODS: Forty-four patients (31 men; mean age 68 years, range 48-85) underwent protected CAS and had DW-MRI before and after the intervention. The cohort was analyzed according to the type of EPD used: a proximal EPD was deployed in 25 (56.8%) patients (17 men; mean age 66 years, range 48-85) and a distal filter in 19 (14 men; mean age 70 years, range 58-79). Fifteen (60.0%) patients with proximal protection were symptomatic of the target lesion; in the distal protection group, 10 (52.6%) were symptomatic. RESULTS: New lesions were seen on the postinterventional DW-MRI in 28.0% (7/25) of the proximal EPD group versus 32.6% (6/19) of those with a distal filter (p = NS). The majority were clinically silent. The new lesions in the vascular territory of the stented carotid artery in the group as a whole and per patient were fewer in the proximal EPD group (p = NS). No significant differences were noted in the T(2) appearance of the new lesions or the number of new lesions observed away from the vascular territory of the stented artery. CONCLUSION: Proximal embolus protection devices show a nonsignificant trend toward fewer embolic events, which warrants large-scale studies. Furthermore, proximal protection devices can be useful to control and treat acute in-stent thrombosis.
Resumo:
Background: Classical Roux-en-Y gastric bypass (cRYGB) is a combined restrictive and slightly malabsorptive operation. Excess-BMI-loss (EBMIL) in cRYGB is ~60%, but is diminished for super obese patients (BMI > 50 kg/m2). We therefore designed a modified, mainly malabsorptive distal RYGB (dRYGB). Methods: We report mid-term results after 77 consecutive dRYGB in which malabsorption is inversely related to the length of the common channel. The common channel was 100–150 cm long depending on preoperative BMI, the biliopancreatic limb was 100 cm long, which left >>250 cm for the alimentary channel. To avoid the potentially dangerous combination of malabsorption with sustained restriction the pouch size was increased to ~50ml and a 25 mm circular stapler was used for the gastro-jejunostomy. Results: 33 open and later on 44 laparoscopic interventions have been performed. Median preoperative BMI was 50.2 kg/m 2. No severe intraoperative complications have been observed and no anastomotic leakage was noted in the postoperative period. 5 patients needed balloon dilation of an anastomotic stricture. 3 marginal ulcers occurred at the gastrojejunostomy. The 54 patients with a follow-up time of over 12 months (median 24 months) showed an overall median BMI-reduction of 17 to an actual median BMI of 31.6 kg/m2, corresponding to a EBMIL of 74.5%. Obesity-related comorbid conditions were significantly reduced or cured. Intermittent diarrhea or steatorrhea in 12 patients was easily treated by pancreatic enzyme supplementation. Conclusion: dRYGB is technically more demanding than cRYGB, but shows excellent results in terms of weight-loss and therefore also in reduction of comorbidity especially in super-obese patients. Measuring all three limb lengths allows for a calibration of the malabsorption. The quality of food-intake being important to (super-) obese patients in terms of quality of life, a less restrictive pouch seems more adapted to them. Lifelong multidisciplinary follow-up is mandatory.
Resumo:
Mutations in the B1 subunit of the multisubunit vacuolar ATPase cause autosomal-recessive distal renal tubular acidosis and sensorineural deafness. Here, we report a novel frameshift mutation that truncates the C-terminus of the human B1 subunit. This mutant protein failed to assemble with other subunits in the cytosol to form the complex that can be targeted to vesicular structures in mammalian cells. Loss of proton pump activity was demonstrated in a functional complementation assay in B-subunit null yeast. The mutation caused loss of a discreet C-terminal region critical for subunit interaction not related to the C-terminal PDZ motif. Co-expression studies failed to demonstrate dominant negative effects of this truncated mutant over wild-type B1. Analysis of 12 reported B1 subunit missense mutations showed one polymorphic allele had intact pump function, two point mutants had intact assembly but defective proton pumping, and the remaining nine had disrupted assembly with no pump function. One presumed polymorphic allele was actually an inactivating mutation. Our study shows that multiple mechanisms of pump dysfunction result from B1 subunit mutations with a common outcome being defective assembly. Polymorphisms of the B1 subunit in the general population may affect renal acidification and urinary chemistry.