71 resultados para Detecting rice tungro viruses


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Aim of this study was to compare the utility of susceptibility weighted imaging (SWI) with the established diagnostic techniques CT and fluid attenuated inversion recovery (FLAIR) in their detecting capacity of subarachnoid hemorrhage (SAH), and further to compare the combined SWI/FLAIR MRI data with CT to evaluate whether MRI is more accurate than CT. METHODS: Twenty-five patients with acute SAH underwent CT and MRI within 6 days after symptom onset. Underlying pathology for SAH was head trauma (n=9), ruptured aneurysm (n=6), ruptured arteriovenous malformation (n=2), and spontaneous bleeding (n=8). SWI, FLAIR, and CT data were analyzed. The anatomical distribution of SAH was subdivided into 8 subarachnoid regions with three peripheral cisterns (frontal-parietal, temporal-occipital, sylvian), two central cisterns and spaces (interhemispheric, intraventricular), and the perimesencephalic, posterior fossa, superior cerebellar cisterns. RESULTS: SAH was detected in a total of 146 subarachnoid regions. CT identified 110 (75.3%), FLAIR 127 (87%), and SWI 129 (88.4%) involved regions. Combined FLAIR and SWI identified all 146 detectable regions (100%). FLAIR was sensitive for frontal-parietal, temporal-occipital and Sylvian cistern SAH, while SWI was particularly sensitive for interhemispheric and intraventricular hemorrhage. CONCLUSIONS: By combining SWI and FLAIR, MRI yields a distinctly higher detection rate for SAH than CT alone, particularly due to their complementary detection characteristics in different anatomical regions. Detection strength of SWI is high in central areas, whereas FLAIR shows a better detection rate in peripheral areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fluorescence microlymphography (FML) is used to visualize the lymphatic capillaries. A maximum spread of the fluorescence dye of ≥ 12 mm has been suggested for the diagnosis of lymphedema. However, data on sensitivity and specificity are lacking. The aim of this study was to investigate the accuracy of FML for diagnosing lymphedema in patients with leg swelling. Patients with lower extremity swelling were clinically assessed and separated into lymphedema and non-lymphatic edema groups. FML was studied in all affected legs and the maximum spread of lymphatic capillaries was measured. Test accuracy and receiver operator characteristic (ROC) analysis was performed to assess possible threshold values that predict lymphedema. Between March 2008 and August 2011 a total of 171 patients (184 legs) with a median age of 43.5 (IQR 24, 54) years were assessed. Of those, 94 (51.1%) legs were diagnosed with lymphedema. The sensitivity, specificity, positive and negative likelihood ratio and positive and negative predictive value were 87%, 64%, 2.45, 0.20, 72% and 83% for the 12-mm cut-off level and 79%, 83%, 4.72, 0.26, 83% and 79% for the 14-mm cut-off level, respectively. The area under the ROC curve was 0.82 (95% CI: 0.76, 0.88). Sensitivity was higher in the secondary versus primary lymphedema (95.0% vs 74.3%, p = 0.045). No major adverse events were observed. In conclusion, FML is a simple and safe technique for detecting lymphedema in patients with leg swelling. A cut-off level of ≥ 14-mm maximum spread has a high sensitivity and high specificity of detecting lymphedema and should be chosen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bovine viral diarrhea virus (BVDV), together with Classical swine fever virus (CSFV) and Border disease virus (BDV) of sheep, belongs to the genus Pestivirus of the Flaviviridae. BVDV is either cytopathic (cp) or noncytopathic (ncp), as defined by its effect on cultured cells. Infection of pregnant animals with the ncp biotype may lead to the birth of persistently infected calves that are immunotolerant to the infecting viral strain. In addition to evading the adaptive immune system, BVDV evades key mechanisms of innate immunity. Previously, we showed that ncp BVDV inhibits the induction of apoptosis and alpha/beta interferon (IFN-alpha/beta) synthesis by double-stranded RNA (dsRNA). Here, we report that (i) both ncp and cp BVDV block the induction by dsRNA of the Mx protein (which can also be induced in the absence of IFN signaling); (ii) neither biotype blocks the activity of IFN; and (iii) once infection is established, BVDV is largely resistant to the activity of IFN-alpha/beta but (iv) does not interfere with the establishment of an antiviral state induced by IFN-alpha/beta against unrelated viruses. The results of our study suggest that, in persistent infection, BVDV is able to evade a central element of innate immunity directed against itself without generally compromising its activity against unrelated viruses ("nonself") that may replicate in cells infected with ncp BVDV. This highly selective "self" and "nonself" model of evasion of the interferon defense system may be a key element in the success of persistent infection in addition to immunotolerance initiated by the early time point of fetal infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coxsackie B viruses types 1-6 (CVB1-6) occur worldwide and cause a broad spectrum of diseases, including myocarditis and aseptic meningitis. Although renal damage due to CVB has been suspected since the 1950s, these agents are only rarely searched for in today's clinical nephrological practice. Nevertheless, CVB can infect mesangial cells. Furthermore, infections with these viruses lead to a histological picture resembling mesangioproliferative glomerulonephritis and IgA-nephropathy in mice. In the present article, we provide an overview of this largely neglected topic, and of the slowly and steadily increasing evidence suggesting a link between coxsackieviral infections and kidney diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Multislice computed tomography (MSCT) is a promising noninvasive method of detecting coronary artery disease (CAD). However, most data have been obtained in selected series of patients. The purpose of the present study was to investigate the accuracy of 64-slice MSCT (64 MSCT) in daily practice, without any patient selection. METHODS AND RESULTS: Using 64-slice MSCT coronary angiography (CTA), 69 consecutive patients, 39 (57%) of whom had previously undergone stent implantation, were evaluated. The mean heart rate during scan was 72 beats/min, scan time 13.6 s and the amount of contrast media 72 mL. The mean time span between invasive coronary angiography (ICAG) and CTA was 6 days. Significant stenosis was defined as a diameter reduction of > 50%. Of 966 segments, 884 (92%) were assessable. Compared with ICAG, the sensitivity of CTA to diagnose significant stenosis was 90%, specificity 94%, positive predictive value (PPV) 89% and negative predictive value (NPV) 95%. With regard to 58 stented lesions, the sensitivity, specificity, PPV and NPV were 93%, 96%, 87% and 98%, respectively. On the patient-based analysis, the sensitivity, specificity, PPV and NPV of CTA to detect CAD were 98%, 86%, 98% and 86%, respectively. Eighty-two (8%) segments were not assessable because of irregular rhythm, calcification or tachycardia. CONCLUSION: Sixty-four-MSCT has a high accuracy for the detection of significant CAD in an unselected patient population and therefore can be considered as a valuable noninvasive technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study compared the results of reverse transcription-polymerase chain reaction (RT-PCR) and traditional virus isolation on cell culture in detection of viral haemorrhagic septicaemia virus (VHSV) and infectious haematopoietic necrosis virus (IHNV). RT-PCR was used for 172 tissue sample pools (total of 859 fish) originating from a field survey on the occurrence of VHSV and IHNV in farmed and wild salmonids in Switzerland. These samples represented all sites with fish that were either identified as virus-positive by means of virus isolation (three sites, four positive tissue sample pools) and/or demonstrated positive anti-VHSV-antibody titres (83 sites, 121 positive blood samples) in a serum plaque neutralization test (SPNT). The RT-PCR technique confirmed the four VHSV-positive tissue sample pools detected by virus isolation and additionally identified one VHSV-positive sample that showed positive anti-VHSV-AB titres, but was negative in virus isolation. With IHNV, RT-PCR detected two positive samples not identified by virus isolation while in these fish the SPNT result had been questionable. One of the IHNV-positive samples represents the first detection of IHNV-RNA in wild brown trout in Switzerland. Compared to SPNT, the RT-PCR method detected, as with virus isolation, a much lower number of positive cases; reasons for this discrepancy are discussed. Our results indicate that RT-PCR can not only be successfully applied in field surveys, but may also be slightly more sensitive than virus isolation. However, in a titration experiment under laboratory conditions, the sensitivity of RT-PCR was not significantly higher when compared with virus isolation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Five diagnostic techniques performed on skin biopsies (shoulder region) and/or serum were compared for detection of bovine viral diarrhea virus infection in 224 calves 0-3 months of age, 23 calves older than 3 months but younger than 7 months, and 11 cattle older than 7 months. The diagnostic methods used were immunohistochemistry (IHC), 2 commercial antigen ELISAs, 1 commercial antibody ELISA, and real-time RT-PCR. Results of 249 out of 258 skin and serum samples were identical and correlated within the 3 antigen detection methods and the real-time RT-PCR used. Twenty-six of these 249 samples were BVDV-positive with all antigen detection methods and the real-time RT-PCR. Nine out of 258 samples yielding discordant results were additionally examined by RT-PCR, RT-PCR Reamplification (ReA), and antigen ELISA I on serum and by immunohistochemistry on formalin fixed and paraffin-embedded skin biopsies. Virus isolation and genotyping was performed as well on these discordant samples. In 3 cases, transiently infected animals were identified. Two samples positive by real-time RT-PCR were interpreted as false positive and were ascribed to cross-contamination. The antigen ELISA II failed to detect 2 BVDV-positive calves due to the presence of maternal antibodies; the cause of 2 false-positive cases in this ELISA remained undetermined. Only persistently infected animals were identified in skin samples by IHC or antigen ELISA I. The 3 antigen detection methods and the real-time RT-PCR used in parallel had a high correlation rate (96.5%) and similar sensitivity and specificity values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To retrospectively determine the sensitivity of ovarian artery (OA) visualization at aortography performed after uterine fibroid embolization (UFE) and, using OA arteriography as the reference standard, compare the extent of arterial flow to the uterus at aortography with selective ovarian arteriography, to establish the utility of aortography and ovarian arteriography in the routine practice of UFE. MATERIALS AND METHODS: This study received institutional review board approval with waiver of informed consent and was HIPAA compliant. Retrospective review of 1129 consecutive UFE patients (1072 with aortograms, 57 excluded; mean age, 44 years; range, 21-60 years) was performed to identify all visible OAs. Visible OAs were independently graded by two interventional radiologists according to extent of pelvic arterial flow. If selective arteriography was performed, a second grade was assigned based on assessment of the selective study. Descriptive and summary statistics were used for assessment by the senior observer, and interobserver variability was determined. RESULTS: Of 1072 UFE patients, 184 (17.2%) had at least one visible OA. Ten (0.8%) patients were identified at aortography with collateral OA supply to more than 10% of the uterus. In total, 251 OAs were visualized, and 157 of these were further evaluated with selective study. Sixty-two (5.8%) patients were identified at selective arteriography as having collateral OA supply. The sensitivity of aortography was approximately 18%. Interobserver concordance was high (kappa values of 0.81 and 0.90 for aortography and selective study, respectively), but not perfect. CONCLUSION: Aortography rarely helps identify patients with substantial residual OA supply to the uterus and is a poor predictor of the extent of that supply, and thus may be of limited utility in routine UFE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The aim of this study was to evaluate the influence of zero-value subtraction on the performance of two laser fluorescence (LF) devices developed to detect occlusal caries. METHODS: The authors selected 119 permanent molars. Two examiners assessed three areas (cuspal, middle and cervical) of both mesial and distal portions of the buccal surface and one occlusal site using an LF device and an LF pen. For each tooth, the authors subtracted the value measured in the cuspal, middle and cervical areas in the buccal surface from the value measured in the respective occlusal site. RESULTS: The authors observed differences among the readings for both devices in the cuspal, middle and cervical areas in the buccal surface as well as differences for both devices with and without the zero-value subtraction in the occlusal surface. When the authors did not perform the zero-value subtraction, they found statistically significant differences for sensitivity and accuracy for the LF device. When this was done with the LF pen, specificity increased and sensitivity decreased significantly. CONCLUSIONS: For the LF device, the zero-value subtraction decreased the sensitivity. For this reason, the authors concluded that clinicians can obtain measures with the LF device effectively without using zero-value subtraction. For the LF pen, however, the absence of the zero-value subtraction changed both the sensitivity and specificity, and so the authors concluded that clinicians should not eliminate this step from the procedure. CLINICAL IMPLICATIONS: When using the LF device, clinicians might not need to perform the zero-value subtraction; however, for the LF pen, clinicians should do so.