50 resultados para Deformations (Mechanics)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Respiratory system input impedance (Zrs) at low to medium frequencies below 100 Hz, and study of its volume dependence, have been used extensively to quantify airway and tissue mechanics. Zrs at high oscillation frequencies including the first antiresonant frequency (far,1) may contain important information about airway mechanics. Changes in high-frequency Zrs with lung volume have not been studied. The volume-dependent behavior of high-frequency Zrs, specifically far,1 and respiratory system resistance at first antiresonance (Rrs(far,1)), was characterized in 16 healthy adults. Zrs was measured with a forced oscillation signal (5-302.5 Hz) through a wavetube setup. To track Zrs, subjects performed slow deep inspiratory and expiratory maneuvers over 30-s measurements, during which average impedance was calculated over 0.4-s intervals, with successive overlapping estimates every 0.156 s. Flow was measured using a pneumotachometer and integrated to obtain volume. Transpulmonary pressure dependence (Ptp) of Zrs was separately determined in five subjects. Both far,1 and Rrs(far,1) decreased with increasing lung volume and Ptp, consistent with an increase in airway caliber and decreased airway wall compliance as volume increased. These characterizations provide insight into airway mechanics, and are furthermore a necessary first step toward determining whether volume dependence of the first antiresonance is altered in disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eight premature infants ventilated for hyaline membrane disease and enrolled in the OSIRIS surfactant trial were studied. Lung mechanics, gas exchange [PaCO2, arterial/alveolar PO2 ratio (a/A ratio)], and ventilator settings were determined 20 minutes before and 20 minutes after the end of Exosurf instillation, and subsequently at 12-24 hour intervals. Respiratory system compliance (Crs) and resistance (Rrs) were measured by means of the single breath occlusion method. After surfactant instillation there were no significant immediate changes in PaCO2 (36 vs. 37 mmHg), a/A ratio (0.23 vs. 0.20), Crs (0.32 vs. 0.31 mL/cm H2O/kg), and Rrs (0.11 vs. 0.16 cmH2O/mL/s) (pooled data of 18 measurement pairs). During the clinical course, mean a/A ratio improved significantly each time from 0.17 (time 0) to 0.29 (time 12-13 hours), to 0.39 (time 24-36 hours) and to 0.60 (time 48-61 hours), although mean airway pressure was reduced substantially. Mean Crs increased significantly from 0.28 mL/cmH2O/kg (time 0) to 0.38 (time 12-13 hours), to 0.37 (time 24-38 hours), and to 0.52 (time 48-61 hours), whereas mean Rrs increased from 0.10 cm H2O/mL/s (time 0) to 0.11 (time 12-13 hours), to 0.13 (time 24-36 hours) and to (time 48-61 hours) with no overall significance. A highly significant correlation was found between Crs and a/A ratio (r = 0.698, P less than 0.001). We conclude that Exosurf does not induce immediate changes in oxygenation as does the instillation of (modified) natural surfactant preparations. However, after 12 and 24 hours of treatment oxygenation and Crs improve significantly.(ABSTRACT TRUNCATED AT 250 WORDS)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The past decades have seen a rapid increase in the understanding of plant morphogenesis at the molecular-genetic level. However, the control of growth and morphogenesis by molecular and signaling networks ultimately requires the coordinated regulation of mechanical properties in individual cells. There is also increasing evidence that mechanical stresses can feedback on hormone signaling and growth, and may have a central role in developmental patterning. Thus the development of techniques to investigate the mechanical properties of plant tissue at the cellular level is key to understanding growth and morphogenesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Osteochondral autograft transfer (OAT) aims at restoring normal articular cartilage surface geometry and articular contact mechanics. To date, no studies have evaluated the contact mechanics of the canine stifle following OAT. Additionally, there are no studies that evaluated the role of the meniscus in contact mechanics following OAT in human or canine femorotibial joints. The objective of this study was to measure the changes in femorotibial contact areas (CA), mean contact pressure (MCP) and peak contact pressure (PCP) before and after osteochondral autograft transplantation (OAT) of a simulated lateral femoral condylar cartilage defect with an intact lateral meniscus and following lateral meniscectomy. RESULTS With an intact lateral meniscus, creation of an osteochondral defect caused a decrease in MCP and PCP by 11% and 30%, respectively, compared to the intact stifle (p < 0.01). With an intact meniscus, implanting an osteochondral graft restored MCP and PCP to 96% (p = 0.56) and 92% (p = 0.41) of the control values. Lateral meniscectomy with grafting decreased CA by 54% and increased PCP by 79% compared to the intact stifle (p < 0.01). CONCLUSIONS OAT restored contact pressures in stifles with a simulated lateral condylar defect when the meniscus was intact. The lateral meniscus has a significant role in maintaining normal contact pressures in both stifles with a defect or following OAT. Meniscectomy should be avoided when a femoral condylar defect is present and when performing OAT.