158 resultados para Database Tomography


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Choline positron emission tomography (PET)/computed tomography (CT) is a currently used diagnostic tool in restaging prostate cancer (PCa) patients with increasing prostate-specific antigen (PSA) after either radical prostatectomy (RP) or external-beam radiation therapy (EBRT). However, no final recommendations have been made on the use of this modality for patient management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By measuring the total crack lengths (TCL) along a gunshot wound channel simulated in ordnance gelatine, one can calculate the energy transferred by a projectile to the surrounding tissue along its course. Visual quantitative TCL analysis of cut slices in ordnance gelatine blocks is unreliable due to the poor visibility of cracks and the likely introduction of secondary cracks resulting from slicing. Furthermore, gelatine TCL patterns are difficult to preserve because of the deterioration of the internal structures of gelatine with age and the tendency of gelatine to decompose. By contrast, using computed tomography (CT) software for TCL analysis in gelatine, cracks on 1-cm thick slices can be easily detected, measured and preserved. In this, experiment CT TCL analyses were applied to gunshots fired into gelatine blocks by three different ammunition types (9-mm Luger full metal jacket, .44 Remington Magnum semi-jacketed hollow point and 7.62 × 51 RWS Cone-Point). The resulting TCL curves reflected the three projectiles' capacity to transfer energy to the surrounding tissue very accurately and showed clearly the typical energy transfer differences. We believe that CT is a useful tool in evaluating gunshot wound profiles using the TCL method and is indeed superior to conventional methods applying physical slicing of the gelatine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although postmortem imaging has gained prominence in the field of forensic medicine, evaluation of the postmortem lung remains problematic. Specifically, differentiation of normal postmortem changes and pathological pulmonary changes is challenging and at times impossible. In this study, five corpses were ventilated using a mechanical ventilator with a pressure of 40 mbar (40.8 cm H(2)O). The ventilation was performed via an endotracheal tube, a larynx mask or a continuous positive airway pressure mask. Postmortem computed tomographic images of the lungs before and with a ventilation of 40 mbar (40.8 cm H(2)O) were evaluated and the lung volumes were measured with segmentation software. Postmortem ventilation led to a clearly visible decrease of both the density in the dependant parts of the lungs and ground glass attenuation, whereas consolidated areas remained unchanged. Furthermore, a mean increase in the lung volume of 2.10 l was seen. Pathological changes such as septal thickening or pulmonary nodules in the lung parenchyma became more detectable with postmortem ventilation. Intracorporal postmortem mechanical ventilation of the lungs appears to be an effective method for enhancing detection of small pathologies of the lung parenchyma as well as for discriminating between consolidation, ground glass attenuation and position-dependent density.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Modern imaging technologies, such as computed tomography (CT) techniques, represent a great challenge in forensic pathology. The field of forensics has experienced a rapid increase in the use of these new techniques to support investigations on critical cases, as indicated by the implementation of CT scanning by different forensic institutions worldwide. Advances in CT imaging techniques over the past few decades have finally led some authors to propose that virtual autopsy, a radiological method applied to post-mortem analysis, is a reliable alternative to traditional autopsy, at least in certain cases. The authors investigate the occurrence and the causes of errors and mistakes in diagnostic imaging applied to virtual autopsy. A case of suicide by a gunshot wound was submitted to full-body CT scanning before autopsy. We compared the first examination of sectional images with the autopsy findings and found a preliminary misdiagnosis in detecting a peritoneal lesion by gunshot wound that was due to radiologist's error. Then we discuss a new emerging issue related to the risk of diagnostic failure in virtual autopsy due to radiologist's error that is similar to what occurs in clinical radiology practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The first generation of the everolimus-eluting bioresorbable vascular scaffold (BVS 1.0) showed an angiographic late loss higher than the metallic everolimus-eluting stent Xience V due to scaffold shrinkage. The new generation (BVS 1.1) presents a different design and manufacturing process than the BVS 1.0. This study sought to evaluate the differences in late shrinkage, neointimal response, and bioresorption process between these two scaffold generations using optical coherence tomography (OCT).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study is to assess jailing of side branches (SB) by the everolimus-eluting, bioresorbable vascular scaffold (BVS) with 3-dimensional (3D) optical coherence tomography (OCT) reconstruction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Blood aspiration is a significant forensic finding. In this study, we examined the value of postmortem computed tomography (CT) imaging in evaluating findings of blood aspiration. We selected 37 cases with autopsy evidence of blood in the lungs and/or in the airways previously submitted to total-body CT scanning. The CT-images were retrospectively analyzed. In one case with pulmonary blood aspiration, biopsy specimens were obtained under CT guide for histological examination. In six cases, CT detected pulmonary abnormalities suggestive of blood aspiration, not mentioned in the autopsy reports. CT reconstructions provided additional data about the distribution and extent of aspiration. In one needle-biopsied case, the pulmonary specimens showed blood in the alveoli. We suggest the use of CT imaging as a tool complementary to traditional techniques in cases of blood aspiration to avoid misdiagnosis, to guide the investigation of lung tissue, and to allow for more evidence-based inferences on the cause of death.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As an Alpine country, Switzerland has not only a thriving mountaineering tourist industry, but also many mountaineering casualties. At the request of the state attorney, most of the victims undergo only an external inspection without autopsy. One of the main tasks of the forensic pathologist under these circumstances is the correct identification of the deceased for a fast release to their kin. Nevertheless, detailed knowledge of the injuries sustained may lead to improved safety measures, such as better protective equipment. In this study, we examined the feasibility of using cross-sectional imaging with postmortem multi-slice computed tomography (MSCT) to detect lesions of the skeletal structures and internal organs. For this purpose, we used whole-body MSCT to examine 10 corpses that suffered fatal falls from great height while climbing in the Swiss part of the European Alps from the years 2007 to 2009. We conclude that postmortem CT imaging is a valuable tool for dental identification and is superior to plain X-rays as a viable compromise between a solely external legal inspection and an autopsy because it delivers otherwise irretrievable additional internal findings non-invasively. This fact is of great importance in cases where an autopsy is refused.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A variety of conformationally constrained aspartate and glutamate analogues inhibit the glutamate transporter 1 (GLT-1, also known as EAAT2). To expand the search for such analogues, a virtual library of aliphatic aspartate and glutamate analogues was generated starting from the chemical universe database GDB-11, which contains 26.4 million possible molecules up to 11 atoms of C, N, O, F, resulting in 101026 aspartate analogues and 151285 glutamate analogues. Virtual screening was realized by high-throughput docking to the glutamate binding site of the glutamate transporter homologue from Pyrococcus horikoshii (PDB code: 1XFH ) using Autodock. Norbornane-type aspartate analogues were selected from the top-scoring virtual hits and synthesized. Testing and optimization led to the identification of (1R*,2R*,3S*,4R*,6R*)-2-amino-6-phenethyl-bicyclo[2.2.1]heptane-2,3-dicarboxylic acid as a new inhibitor of GLT-1 with IC(50) = 1.4 ?M against GLT-1 and no inhibition of the related transporter EAAC1. The systematic diversification of known ligands by enumeration with help of GDB followed by virtual screening, synthesis, and testing as exemplified here provides a general strategy for drug discovery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is unclear whether anti-VEGF monotherapy in age-related macular degeneration (AMD) achieves morphologic CNV regression or only stops further CNV growth. In this study, spectral domain-optical coherence tomography (SD-OCT) was used to image CNV structure before and after anti-VEGF treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

X-linked retinoschisis (XLRS) is one of the most common causes of macular degeneration in young men. The purpose of this study was to use optical coherence tomography combined with ophthalmoscopy to study the effects of aging on the morphologic changes associated with XLRS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the intraoperative use of handheld Fourier-domain optical coherence tomography (OCT) during Descemet stripping automated endothelial keratoplasty (DSAEK) to assess the donor-host interface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To determine the frequency of incidental maxillary sinus findings using cone-beam computed tomography (CBCT) images made for orthodontic purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new multimodal biometric database designed and acquired within the framework of the European BioSecure Network of Excellence is presented. It is comprised of more than 600 individuals acquired simultaneously in three scenarios: 1) over the Internet, 2) in an office environment with desktop PC, and 3) in indoor/outdoor environments with mobile portable hardware. The three scenarios include a common part of audio/video data. Also, signature and fingerprint data have been acquired both with desktop PC and mobile portable hardware. Additionally, hand and iris data were acquired in the second scenario using desktop PC. Acquisition has been conducted by 11 European institutions. Additional features of the BioSecure Multimodal Database (BMDB) are: two acquisition sessions, several sensors in certain modalities, balanced gender and age distributions, multimodal realistic scenarios with simple and quick tasks per modality, cross-European diversity, availability of demographic data, and compatibility with other multimodal databases. The novel acquisition conditions of the BMDB allow us to perform new challenging research and evaluation of either monomodal or multimodal biometric systems, as in the recent BioSecure Multimodal Evaluation campaign. A description of this campaign including baseline results of individual modalities from the new database is also given. The database is expected to be available for research purposes through the BioSecure Association during 2008.