25 resultados para Corner reflector


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die Neuraltherapie nach Huneke ist eine Injektionsbehandlung, welche Lokalanästhetika zur Diagnostik und Therapie einsetzt. Je nach Situation erfolgt der Reiz (und/oder die Unterbrechung einer pathologischen Belastung) im Bereiche der Segmentreflektorik oder über das sogenannte Störfeld. Dieses kann ausserhalb jeder segmentalen Ordnung eine Erkrankung oder ein Schmerzbild auslösen und unterhalten. Mit der Neuraltherapie werden gezielt autoregulatorische Mechanismen des Vegetativums (insbesondere des Sympathikus) angesprochen. Theoretische Grundlagen hierzu sind Erkenntnisse aus der Neurophysiologie und der Modernen Physik.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, we present a novel technique for the removal of astigmatism in submillimeter-wave optical systems through employment of a specific combination of so-called astigmatic off-axis reflectors. This technique treats an orthogonally astigmatic beam using skew Gaussian beam analysis, from which an anastigmatic imaging network is derived. The resultant beam is considered truly stigmatic, with all Gaussian beam parameters in the orthogonal directions being matched. This is thus considered an improvement over previous techniques wherein a beam corrected for astigmatism has only the orthogonal beam amplitude radii matched, with phase shift and phase radius of curvature not considered. This technique is computationally efficient, negating the requirement for computationally intensive numerical analysis of shaped reflector surfaces. The required optical surfaces are also relatively simple to implement compared to such numerically optimized shaped surfaces. This technique is implemented in this work as part of the complete optics train for the STEAMR antenna. The STEAMR instrument is envisaged as a mutli-beam limb sounding instrument operating at submillimeter wavelengths. The antenna optics arrangement for this instrument uses multiple off-axis reflectors to control the incident radiation and couple them to their corresponding receiver feeds. An anastigmatic imaging network is successfully implemented into an optical model of this antenna, and the resultant design ensures optimal imaging of the beams to the corresponding feed horns. This example also addresses the challenges of imaging in multi-beam antenna systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, we report on an optical tolerance analysis of the submillimeter atmospheric multi-beam limb sounder, STEAMR. Physical optics and ray-tracing methods were used to quantify and separate errors in beam pointing and distortion due to reflector misalignment and primary reflector surface deformations. Simulations were performed concurrently with the manufacturing of a multi-beam demonstrator of the relay optical system which shapes and images the beams to their corresponding receiver feed horns. Results from Monte Carlo simulations show that the inserts used for reflector mounting should be positioned with an overall accuracy better than 100 μm (~ 1/10 wavelength). Analyses of primary reflector surface deformations show that a deviation of magnitude 100 μm can be tolerable before deployment, whereas the corresponding variations should be less than 30 μm during operation. The most sensitive optical elements in terms of misalignments are found near the focal plane. This localized sensitivity is attributed to the off-axis nature of the beams at this location. Post-assembly mechanical measurements of the reflectors in the demonstrator show that alignment better than 50 μm could be obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The primary isolation of a Mycobacterium sp. of the Mycobacterium tuberculosis complex from an infected animal provides a definitive diagnosis of tuberculosis. However, as Mycobacterium bovis and Mycobacterium caprae are difficult to isolate, particularly for animals in the early stages of disease, success is dependent on the optimal performance of all aspects of the bacteriological process, from the initial choice of tissue samples at post-mortem examination or clinical samples, to the type of media and conditions used to cultivate the microorganism. Each step has its own performance characteristics, which can contribute to sensitivity and specificity of the procedure, and may need to be optimized in order to achieve the gold standard diagnosis. Having isolated the slow-growing mycobacteria, species identification and fine resolution strain typing are keys to understanding the epidemiology of the disease and to devise strategies to limit transmission of infection. New technologies have emerged that can now even discriminate different isolates from the same animal. In this review we highlight the key factors that contribute to the accuracy of bacteriological diagnosis of M. bovis and M. caprae, and describe the development of advanced genotyping techniques that are increasingly used in diagnostic laboratories for the purpose of supporting detailed epidemiological investigations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The isostructural title compounds, {(C7H7N2)2[SnI4]}n, (1), and {(C7H5F2N2)2[SnI4]}n, (2), show a layered perovskite-type structure composed of anionic {[SnI4]2-}n sheets parallel to (100), which are decorated on both sides with templating benzimidazolium or 5,6-di­fluoro­benzimidazolium cations, respectively. These planar organic heterocycles mainly form N-H...I hydrogen bonds to the terminal I atoms of the corner-sharing [SnI6] octa­hedra (point group symmetry 2) from the inorganic layer, but not to the bridging ones. This is in contrast to most of the reported structures of related compounds where ammonium cations are involved. Here hydrogen bonding to both types of iodine atoms and thereby a distortion of the inorganic layers to various extents is observed. For (1) and (2), all Sn-I-Sn angles are linear and no out-of-plane distortions of the inorganic layers occur, a fact of relevance in view of the material properties. The arrangement of the aromatic cations is mainly determined through the direction of the N-H...I hydrogen bonds. The coherence between organic bilayers along [100] is mainly achieved through van der Waals inter­actions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Gravity field and steady-state Ocean Circulation Explorer (GOCE) was the first Earth explorer core mission of the European Space Agency. It was launched on March 17, 2009 into a Sun-synchronous dusk-dawn orbit and re-entered into the Earth’s atmosphere on November 11, 2013. The satellite altitude was between 255 and 225 km for the measurement phases. The European GOCE Gravity consortium is responsible for the Level 1b to Level 2 data processing in the frame of the GOCE High-level processing facility (HPF). The Precise Science Orbit (PSO) is one Level 2 product, which was produced under the responsibility of the Astronomical Institute of the University of Bern within the HPF. This PSO product has been continuously delivered during the entire mission. Regular checks guaranteed a high consistency and quality of the orbits. A correlation between solar activity, GPS data availability and quality of the orbits was found. The accuracy of the kinematic orbit primarily suffers from this. Improvements in modeling the range corrections at the retro-reflector array for the SLR measurements were made and implemented in the independent SLR validation for the GOCE PSO products. The satellite laser ranging (SLR) validation finally states an orbit accuracy of 2.42 cm for the kinematic and 1.84 cm for the reduced-dynamic orbits over the entire mission. The common-mode accelerations from the GOCE gradiometer were not used for the official PSO product, but in addition to the operational HPF work a study was performed to investigate to which extent common-mode accelerations improve the reduced-dynamic orbit determination results. The accelerometer data may be used to derive realistic constraints for the empirical accelerations estimated for the reduced-dynamic orbit determination, which already improves the orbit quality. On top of that the accelerometer data may further improve the orbit quality if realistic constraints and state-of-the-art background models such as gravity field and ocean tide models are used for the reduced-dynamic orbit determination.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Satellite laser ranging (SLR) to the satellites of the global navigation satellite systems (GNSS) provides substantial and valuable information about the accuracy and quality of GNSS orbits and allows for the SLR-GNSS co-location in space. In the framework of the NAVSTAR-SLR experiment two GPS satellites of Block-IIA were equipped with laser retroreflector arrays (LRAs), whereas all satellites of the GLONASS system are equipped with LRAs in an operational mode. We summarize the outcome of the NAVSTAR-SLR experiment by processing 20 years of SLR observations to GPS and 12 years of SLR observations to GLONASS satellites using the reprocessed microwave orbits provided by the center for orbit determination in Europe (CODE). The dependency of the SLR residuals on the size, shape, and number of corner cubes in LRAs is studied. We show that the mean SLR residuals and the RMS of residuals depend on the coating of the LRAs and the block or type of GNSS satellites. The SLR mean residuals are also a function of the equipment used at SLR stations including the single-photon and multi-photon detection modes. We also show that the SLR observations to GNSS satellites are important to validate GNSS orbits and to assess deficiencies in the solar radiation pressure models. We found that the satellite signature effect, which is defined as a spread of optical pulse signals due to reflection from multiple reflectors, causes the variations of mean SLR residuals of up to 15 mm between the observations at nadir angles of 0∘ and 14∘. in case of multi-photon SLR stations. For single-photon SLR stations this effect does not exceed 1 mm. When using the new empirical CODE orbit model (ECOM), the SLR mean residual falls into the range 0.1–1.8 mm for high-performing single-photon SLR stations observing GLONASS-M satellites with uncoated corner cubes. For best-performing multi-photon stations the mean SLR residuals are between −12.2 and −25.6 mm due to the satellite signature effect.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION For ultrasonographic diagnosis of a fetal trisomy so-called "soft markers" (=ultrasonographically detectable morphological variants) are used. Detection of a certain number of them increases the diagnostic certainty of a fetal trisomy. Up to now there are very few diagnostically accepted osseous soft markers for trisomy. Hence potential osseous soft markers applicable for first and second trimester ultrasound screening for trisomy 21, 18 or 13 were studied. METHODS Postmortal fetal X-rays (ap, lateral) of 358 fetuses (trisomy 21: n = 109, trisomy 18: n = 46; trisomy 13: n = 38, control group: n = 165). RESULTS Not yet described but with trisomy 21 statistically associated soft markers were un-timely os sternale ossification, delayed os sacrum ossification, shortened os maxillare, reduced os maxillare-jaw-corner distance, augmented orbita height, premature os calcaneus ossification, bell-shaped thorax, coronal clefts, trend to wider binocular as well as wider intraocular distances; for trisomy 18: elevated clavicula slope, reduced number of ribs, bell-shaped thorax, coronal clefts, reduced os maxillare-jaw-corner distance, shortened ramus mandibulare, shortened os metacarpale IV and V, augmented ratio between biparietal diameter and (osseus and soft-tissue) shoulder width; for trisomy 13: longer os nasale, elevated clavicula slope, premature sternum, delayed os sacrum ossification, delayed/premature cranium ossification, reduced number of ribs, coronal clefts, reduced os maxillare-jaw-corner distance, shortened ramus mandibulare, augmented orbita height, shortened os metacarpale V and a tendency for a shortened os metacarpale IV. CONCLUSION We found several not yet published osseous soft markers statistically associated with trisomy 21, 18 and 13, which can help to ensure sonographically these aneuploidy diagnoses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Laying hens in loose-housing systems select a nest daily in which to lay their eggs among many identical looking nests, they often prefer corner nests. We investigated whether heterogeneity in nest curtain appearance – via colours and symbols – would influence nest selection and result in an even distribution of eggs among nests. We studied pre-laying behaviour in groups of 30 LSL hens across two consecutive trials with eight groups per trial. Half of the groups had access to six identical rollaway group-nests, while the others had access to six nests of the same type differing in outer appearance. Three colours (red, green, yellow) and three black symbols (cross, circle, rectangle) were used to create three different nest curtain designs per pen. Nest position and the side of entrance to the pens were changed at 28 and 30 weeks of age, respectively, whereby the order of changes was counterbalanced across trials. Nest positions were numbered 1–6, with nest position 1 representing the nest closest to the pen entrance. Eggs were counted per nest daily from week of age 18 to 33. Nest visits were recorded individually with an RFID system for the first 5 h of light throughout weeks 24–33. Hens with access to nests differing in curtain appearance entered fewer nests daily than hens with identical nests throughout the study but both groups entered more nests with increasing age. We found no other evidence that curtain appearance affected nest choice and hens were inconsistent in their daily nest selection. A high proportion of eggs were laid in corner nests especially during the first three weeks of lay. The number of visits per egg depended upon nest position and age: it increased with age and was higher after the nest position change than before in nest position 1, whereas it stayed stable over time in nest position 6. At 24 weeks of age, gregarious nest visits (hens visiting an occupied nest when there was at least one unoccupied nest) and solitary nest visits (hens visiting an unoccupied nest when there was at least one occupied nest) accounted for a similar amount of nest visits, however, after the door switch, gregarious nest visits made up more than half of all nest visits, while the number of solitary nest visits had decreased. The visual cues were too subtle or inadequate for hens to develop individual preferences while nest position, entrance side, age and nest occupancy affected the quantity and type of nest visits.