28 resultados para Contrast media


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The efficiency of an oncological treatment regimen is often assessed by morphological criteria such as tumour size evaluated by cross-sectional imaging, or by laboratory measurements of plasma biomarkers. Because these types of measures typically allow for assessment of treatment response several weeks or even months after the start of therapy, earlier response assessment that provides insight into tumour function is needed. This is particularly urgent for the evaluation of newer targeted therapies and for fractionated therapies that are delivered over a period of weeks to allow for a change of treatment in non-responding patients. Diffusion-weighted MRI (DW-MRI) is a non-invasive imaging tool that does not involve radiation or contrast media, and is sensitive to tissue microstructure and function on a cellular level. DW-MRI parameters have shown sensitivity to treatment response in a growing number of tumour types and organ sites, with additional potential as predictive parameters for treatment outcome. A brief overview of DW-MRI principles is provided here, followed by a review of recent literature in which DW-MRI has been used to monitor and predict tumour response to various therapeutic regimens.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hypoxia of renal medulla is a key factor implicated in the development of drug-induced renal failure. Drugs are known to influence renal hemodynamics and, subsequently, affect renal tissue oxygenation. Changes in renal oxygenation can be assessed non-invasively in humans using blood oxygenation level-dependent magnetic resonance imaging (BOLD-MRI). This study was designed to test the acute effects of administration of specific drugs in healthy human kidney oxygenation using BOLD-MRI. Acute changes in renal tissue oxygenation induced by the non-steroidal anti-inflammatory drug indomethacin, the iodinated radio-contrast media (RCM) iopromidum, and the calcineurin inhibitors cyclosporine micro-emulsion (CsA-ME) and tracrolimus were studied in 30 healthy volunteers. A modified Multi Echo Data Image Combination sequence was used to acquire 12 T(2)(*)-weighted images. Four coronal slices were selected to cover both kidneys. The mean R(2)(*) (1/T(2)(*)) values determined in medulla and cortex showed no significant changes induced by indomethacin and tacrolimus administration. CsA-ME decreased medullary (P=0.008) and cortical (P=0.004) R(2)(*) values 2 h after ingestion. Iopromidum caused a significant increase in medullary R(2)(*) within the first 20 min after injection (P<0.001), whereas no relevant changes were observed in renal cortex. None of the measurements showed left-right kidney differences. Significant differences in renal medullary oxygenation were evidenced between female and male subjects (P=0.013). BOLD-MRI was efficient to show effects of specific drugs in healthy renal tissue. Cyclosporine increased renal medullary oxygenation 2 h after ingestion of a single dose, whereas indomethacin and tacrolimus showed no effect on renal oxygenation. Injection of iodinated RCM decreased renal medullary oxygenation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

From conventional radiography to cross-sectional imaging methods, modern radiology offers a wide range of diagnostic tools for investigating patients with fever. To achieve the best results and to yield a correct diagnosis, the radiologist must tailor the diagnostic protocol individually for every patient. The decision on the most suitable imaging method, and the type and timing of contrast media strongly depends on the suspected diagnosis. Based on patient history and laboratory data, some modalities may be contraindicated or the patient may need a premedication. The authors give a short overview of diagnostic strategies in evaluating the most important causes of fever and point to the need of discussion and co-operation between clinicians and radiologists.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Endometriosis corresponds to ectopic endometrial glands and stroma outside the uterine cavity. Clinical symptoms include dysmenorrhoea, dyspareunia, infertility, painful defecation or cyclic urinary symptoms. Pelvic ultrasound is the primary imaging modality to identify and differentiate locations to the ovary (endometriomas) and the bladder wall. Characteristic sonographic features of endometriomas are diffuse low-level internal echos, multilocularity and hyperchoic foci in the wall. Differential diagnoses include corpus luteum, teratoma, cystadenoma, fibroma, tubo-ovarian abscess and carcinoma. Repeated ultrasound is highly recommended for unilocular cysts with low-level internal echoes to differentiate functional corpus luteum from endometriomas. Posterior locations of endometriosis include utero-sacral ligaments, torus uterinus, vagina and recto-sigmoid. Sonographic and MRI features are discussed for each location. Although ultrasound is able to diagnose most locations, its limited sensitivity for posterior lesions does not allow management decision in all patients. MRI has shown high accuracies for both anterior and posterior endometriosis and enables complete lesion mapping before surgery. Posterior locations demonstrate abnormal T2-hypointense, nodules with occasional T1-hyperintense spots and are easier to identify when peristaltic inhibitors and intravenous contrast media are used. Anterior locations benefit from the possibility of MRI urography sequences within the same examination. Rare locations and possible transformation into malignancy are discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Multislice computed tomography (MSCT) is a promising noninvasive method of detecting coronary artery disease (CAD). However, most data have been obtained in selected series of patients. The purpose of the present study was to investigate the accuracy of 64-slice MSCT (64 MSCT) in daily practice, without any patient selection. METHODS AND RESULTS: Using 64-slice MSCT coronary angiography (CTA), 69 consecutive patients, 39 (57%) of whom had previously undergone stent implantation, were evaluated. The mean heart rate during scan was 72 beats/min, scan time 13.6 s and the amount of contrast media 72 mL. The mean time span between invasive coronary angiography (ICAG) and CTA was 6 days. Significant stenosis was defined as a diameter reduction of > 50%. Of 966 segments, 884 (92%) were assessable. Compared with ICAG, the sensitivity of CTA to diagnose significant stenosis was 90%, specificity 94%, positive predictive value (PPV) 89% and negative predictive value (NPV) 95%. With regard to 58 stented lesions, the sensitivity, specificity, PPV and NPV were 93%, 96%, 87% and 98%, respectively. On the patient-based analysis, the sensitivity, specificity, PPV and NPV of CTA to detect CAD were 98%, 86%, 98% and 86%, respectively. Eighty-two (8%) segments were not assessable because of irregular rhythm, calcification or tachycardia. CONCLUSION: Sixty-four-MSCT has a high accuracy for the detection of significant CAD in an unselected patient population and therefore can be considered as a valuable noninvasive technique.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

INTRODUCTION: The indications for endovascular aortic aneurysm repair (EVAR) are mainly established in hostile abdomen, in patients with significant comorbidities which affect the general operability of the patient and, given the necessary infrastructure, also in ruptured aneurysm. Along to those, we present another possible indication in the presence of a kidney allograft in patients with aortic aneurysm. METHODS: Based on a case report of aorto-biiliac stent-graft repair of an infrarenal aortic aneurysm in a patient with renal allograft, a systematic review of the literature was performed of all similar cases concerning surgical therapy in this constellation. RESULTS: EVAR was performed using an aorto-biiliac system (Zenith) Trifab, COOK) in a 61-year-old male patient 11 years after heterotopic renal allotransplantation in the right iliac fossa. Preoperative renal function was normal. Because the donor renal artery was anastomosed to the recipient's external iliac artery the stent-graft was implanted from the left common femoral artery to minimize temporary allograft ischemia. The intra- and postoperative course was uneventful with a follow-up of presently 12 months. A primary type-II endoleak (retroleak from a lumbar artery) is being treated conservatively so far with embolization being a future option. At present there are 15 cases of EVAR in renal allograft patients that have been reported, all of them being successful. DISCUSSION: All data existing in the literature reported to date as well as our own experience justify the first choice of EVAR in morphologically suitable cases. One major advantage of EVAR in this constellation is the avoidance of aortic cross clamping which poses the graft at risk of ischemia. Long-term results will be most important for definite assessment of EVAR. However, contrast media application during the operation and for CT surveillance should be considered as a major disadvantage.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

OBJECTIVES: The aim of this phantom study was to evaluate the contrast-to-noise ratio (CNR) in pulmonary computed tomography (CT)-angiography for 300 and 400 mg iodine/mL contrast media using variable x-ray tube parameters and patient sizes. We also analyzed the possible strategies of dose reduction in patients with different sizes. MATERIALS AND METHODS: The segmental pulmonary arteries were simulated by plastic tubes filled with 1:30 diluted solutions of 300 and 400 mg iodine/mL contrast media in a chest phantom mimicking thick, intermediate, and thin patients. Volume scanning was done with a CT scanner at 80, 100, 120, and 140 kVp. Tube current-time products (mAs) varied between 50 and 120% of the optimal value given by the built-in automatic dose optimization protocol. Attenuation values and CNR for both contrast media were evaluated and compared with the volume CT dose index (CTDI(vol)). Figure of merit, calculated as CNR/CTDIvol, was used to quantify image quality improvement per exposure risk to the patient. RESULTS: Attenuation of iodinated contrast media increased both with decreasing tube voltage and patient size. A CTDIvol reduction by 44% was achieved in the thin phantom with the use of 80 instead of 140 kVp without deterioration of CNR. Figure of merit correlated with kVp in the thin phantom (r = -0.897 to -0.999; P < 0.05) but not in the intermediate and thick phantoms (P = 0.09-0.71), reflecting a decreasing benefit of tube voltage reduction on image quality as the thickness of the phantom increased. Compared with the 300 mg iodine/mL concentration, the same CNR for 400 mg iodine/mL contrast medium was achieved at a lower CTDIvol by 18 to 40%, depending on phantom size and applied tube voltage. CONCLUSIONS: Low kVp protocols for pulmonary embolism are potentially advantageous especially in thin and, to a lesser extent, in intermediate patients. Thin patients profit from low voltage protocols preserving a good CNR at a lower exposure. The use of 80 kVp in obese patients may be problematic because of the limitation of the tube current available, reduced CNR, and high skin dose. The high CNR of the 400 mg iodine/mL contrast medium together with lower tube energy and/or current can be used for exposure reduction.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To prospectively quantify in vitro the influence of gadopentetate dimeglumine and ioversol on the magnetic resonance (MR) imaging signal observed with a variety of musculoskeletal pulse sequences to predict optimum gadolinium concentrations for direct MR arthrography at 1.5 and 3.0 T. MATERIALS AND METHODS: In an in vitro study, T1 and T2 relaxation times of three dilution series of gadopentetate dimeglumine (concentration, 0-20.0 mmol gadolinium per liter) at ioversol concentrations with iodine concentration of 0, 236.4, and 1182 mmol iodine per liter (corresponding to 0, 30, and 150 mg of iodine per milliliter) were measured at 1.5 and 3.0 T. The relaxation rate dependence on concentrations of gadolinium and iodine was analytically modeled, and continuous profiles of signal versus gadolinium concentration were calculated for 10 pulse sequences used in current musculoskeletal imaging. After fitting to experimental discrete profiles, maximum signal-to-noise ratio (SNR), gadolinium concentration with maximum SNR, and range of gadolinium concentration with 90% of maximum SNR were derived. The overall influence of field strength and iodine concentration on these parameters was assessed by using t tests. The deviation of simulated from experimental signal-response profiles was assessed with the autocorrelation of the residuals. RESULTS: The model reproduced relaxation rates of 0.37-38.24 sec(-1), with a mean error of 4.5%. Calculated SNR profiles matched the discrete experimental profiles, with autocorrelation of the residuals divided by the mean of less than 5.0. Admixture of ioversol consistently reduced T1 and T2, narrowed optimum gadolinium concentration ranges (P = .004-.006), and reduced maximum SNR (P < .001 to not significant). Optimum gadolinium concentration was 0.7-3.4 mmol/L at both field strengths. At 3.0 T, maximum SNR was up to 75% higher than at 1.5 T. CONCLUSION: Admixture of ioversol to gadopentetate dimeglumine solutions results in a consistent additional relaxation enhancement, which can be analytically modeled to allow a near-quantitative a priori optimized match of contrast media concentrations and imaging protocol for a broad variety of pulse sequences.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Patients with refractory angina pectoris in end-stage coronary artery disease represent a severe condition with a higher reduction of life-expectancy and quality of life as compared to patients with stable coronary artery disease. It was the purpose of this study to invasively re-evaluate highly symptomatic patients with formerly diagnosed refractory angina pectoris in end-stage coronary artery disease for feasible options of myocardial revascularization. METHODS: Thirty-four patients formerly characterized as having end stage coronary artery disease with refractory angina pectoris were retrospectively followed for coronary interventions. RESULTS: Of those 34 patients 21 (61.8%) were eventually revascularized with percutaneous interventional revascularization (PCI). Due to complex coronary morphology (angulation, chronic total occlusion) PCI demanded an above-average amount of time (66 +/- 42 minutes, range 25-206 minutes) and materials (contrast media 247 +/- 209 ml, range 50-750 ml; PCI guiding wires 2.0 +/- 1.4, range 1-6 wires). Of PCI patients 7 (33.3%) showed a new lesion as a sign of progression of atherosclerosis. Clinical success rate with a reduction to angina class II or lower was 71.4% at 30 days. Surgery was performed in a total of8 (23.5%) patients with a clinical success rate of 62.5%. Based on an intention-to-treat 2 patients of originally 8 (25%) demonstrated clinical success. Mortality during follow-up (1-18 months) was 4.8% in patients who underwent PCI, 25% in patients treated surgically and 25% in those only treated medically. CONCLUSION: The majority of patients with end-stage coronary artery disease can be treated effectively with conventional invasive treatment modalities. Therefore even though it is challenging and demanding PCI should be considered as a first choice before experimental interventions are considered.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND AND AIM OF THE STUDY: Recent studies have suggested placental growth factor (PlGF) and vascular endothelial growth factor (VEGF) as promising new biomarkers for risk stratification in acute coronary syndromes (ACS). However, little is known about the influence of percutaneous coronary intervention (PCI) on circulating PlGF and VEGF levels. METHODS: Thirty-five patients with ACS, 27 patients with stable coronary artery disease (sCAD), and nine healthy controls were enrolled in the study. Although all patients with ACS and 14 patients with stable angina pectoris underwent PCI, 13 patients with coronary artery disease required no revascularization (sCAD). PlGF and VEGF plasma concentrations were measured by immunoassay during and at the end of PCI and coronary angiography. RESULTS: Plasma PlGF levels were comparable in patients with ACS and sCAD on admission. Although coronary angiography or heparin alone did not alter PlGF and VEGF levels, immediately after PCI a dramatic increase was seen in circulating PlGF and a decrease in VEGF, which was independent of the clinical presentation of the patients, heparin administration, or the angiographic procedure itself, but was associated with the extent of coronary artery disease and the amount of the injected contrast media. In-vitro experiments revealed that radiocontrast agents induced the release of PlGF from endothelial cells without altering PlGF mRNA expression. CONCLUSION: Patients undergoing PCI exhibit an increase in circulating PlGF, probably caused by posttranslational modifications of radiocontrast agents in endothelial cells. Therefore, analysis of plasma PlGF and VEGF levels may consider the timing of blood sampling with respect to PCI and contrast media exposure.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE To investigate the ex vivo performance of high-resolution computed tomography (CT) for quantitative assessment of percentage diameter stenosis in coronary arteries compared to histopathology. MATERIALS AND METHODS High-resolution CT was performed in 26 human heart specimens after the injection of iodinated contrast media into the coronary arteries. Coronary artery plaques were visually identified on CT images and the grade of stenosis for each plaque was measured with electronic calipers. All coronary plaques were characterized by histopathology according to the Stary classification, and the percentage of stenosis was measured. RESULTS CT depicted 84% (274/326) of all coronary plaques identified by histology. Missed plaques by CT were of Stary type I (n=31), type II (n=16), and type III (n=5). The stenosis degree significantly correlated between CT and histology (r=0.81, p<0.001). CT systematically overestimated the stenosis of calcified plaques (mean difference - 11.0 ± 9.5%, p<0.01) and systematically underestimated the stenosis of non-calcified plaques (mean difference -6.8 ± 10.4%, p<0.05), while there was no significant difference for mixed-type plaques (mean difference -0.4 ± 11.7%, p=0.85). There was a significant underestimation of stenosis degree as measured by CT for Stary II plaques (mean difference -14 ± 9%, p<0.01) and a significant overestimation for Stary VII plaques (mean difference 9 ± 10%, p<0.05), but there was no significant difference in stenosis degree between both modalities for other plaque types. CONCLUSIONS High-resolution CT reliably depicts advanced stage coronary plaques with an overall good correlation of stenosis degree compared to histology, however, the degree of stenosis is systematically overestimated in calcified and underestimated in non-calcified plaques.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Over the last two decades, imaging of the aorta has undergone a clinically relevant change. As part of the change non-invasive imaging techniques have replaced invasive intra-arterial digital subtraction angiography as the former imaging gold standard for aortic diseases. Computed tomography (CT) and magnetic resonance imaging (MRI) constitute the backbone of pre- and postoperative aortic imaging because they allow for imaging of the entire aorta and its branches. The first part of this review article describes the imaging principles of CT and MRI with regard to aortic disease, shows how both technologies can be applied in every day clinical practice, offering exciting perspectives. Recent CT scanner generations deliver excellent image quality with a high spatial and temporal resolution. Technical developments have resulted in CT scan performed within a few seconds for the entire aorta. Therefore, CT angiography (CTA) is the imaging technology of choice for evaluating acute aortic syndromes, for diagnosis of most aortic pathologies, preoperative planning and postoperative follow-up after endovascular aortic repair. However, radiation dose and the risk of contrast induced nephropathy are major downsides of CTA. Optimisation of scan protocols and contrast media administration can help to reduce the required radiation dose and contrast media. MR angiography (MRA) is an excellent alternative to CTA for both diagnosis of aortic pathologies and postoperative follow-up. The lack of radiation is particularly beneficial for younger patients. A potential side effect of gadolinium contrast agents is nephrogenic systemic fibrosis (NSF). In patients with high risk of NSF unenhanced MRA can be performed with both ECG- and breath-gating techniques. Additionally, MRI provides the possibility to visualise and measure both dynamic and flow information.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We analyze the market for online and offline media in a model of two-dimensional spatial competition where media outlets sell content and advertising space. Consumer preferences are distributed along the style and type of news coverage where the distance costs may vary across dimensions. For integrated provision of online and offline platforms we show that entering the online market reduces average profits and may even constitute a prisoner's dilemma. Specialized provision may yield polarization in the style and type dimensions. This is in contrast to the maximum–minimum differentiation result previously established in the literature on multidimensional horizontal competition. We show that maximal differentiation in both dimensions occurs due to the discrete nature of the type dimension and asymmetric advertising markets.