76 resultados para Coluna vertebral - Anomalias


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Purpose—To compare potential risk factors, clinical symptoms, diagnostic delay, and 3-month outcome between spontaneous internal carotid artery dissection (sICAD) and spontaneous vertebral artery dissection (sVAD). Methods—We compared patients with sICAD (n=668) and sVAD (n=302) treated in 3 university hospitals. Results—Patients with sICAD were older (46.3±9.6 versus 42.0±10.2 years; P<0.001), more often men (62.7% versus 53.0%; P=0.004), and presented more frequently with tinnitus (10.9% versus 3.4%; P<0.001) and more severe ischemic strokes (median National Institutes of Health Stroke Scale, 10±7.1 versus 5±5.9; P<0.001). Patients with sVAD had more often bilateral dissections (15.2% versus 7.6%; P<0.001) and were more often smokers (36.0% versus 28.7%; P=0.007). Thunderclap headache (9.2% versus 3.6%; P=0.001) and neck pain were more common (65.8% versus 33.5%; P<0.001) in sVAD. Subarachnoid hemorrhage (6.0% versus 0.6%; P<0.001) and ischemic stroke (69.5% versus 52.2%; P<0.001) were more frequent in sVAD. After multivariate analysis, sex difference lost its significance (P=0.21), and all other variables remained significant. Time to diagnosis was similar in sICAD and sVAD and improved between 2001 and 2012 compared with the previous 10-year period (8.0±10.5 days versus 10.7±13.2 days; P=0.004). In sVAD, favorable outcome 3 months after ischemic stroke (modified Rankin Scale, 0–2: 88.8% versus 58.4%; P<0.001), recurrent transient ischemic attack (4.8% versus 1.1%; P=0.001), and recurrent ischemic stroke (2.8% versus 0.7%; P=0.02) within 3 months were more frequent. Conclusions—sICAD and sVAD patients differ in many aspects. Future studies should perform separate analyses of these 2 entities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Few data exist about clinical, radiologic findings, clinical outcome, and its predictors in patients with spontaneous vertebral artery dissection (sVAD). METHODS: Clinical characteristics, imaging findings, 3-month outcomes, and its predictors were investigated in consecutive patients with sVAD. RESULTS: One hundred sixty-nine patients with 195 sVAD were identified. Brain ischemia occurred in 131 patients (77%; ischemic stroke, n=114, 67%; transient ischemic attack, n=17, 10%). Three patients with ischemic stroke showed also signs of subarachnoid hemorrhage (SAH); 3 (2%) had SAH without ischemia. The 134 patients with brain ischemia or SAH had head and/or neck pain in 118 (88%) and pulsatile tinnitus in seven (5%) patients. The remaining 35 patients (21%) had isolated head and/or neck pain in 21 (12%) cases, asymptomatic sVAD in 13 (8%), and cervical radiculopathy in one case (1%). Location of sVAD was more often in the pars transversaria (V2; 35%) or atlas loop (V3; 34%) than in the prevertebral (V1; 20%) or intracranial (V4; 11%) segment (P=0.0001). Outcome was favorable (modified Rankin scale score 0 or 1) in 88 (82%) of 107 ischemic stroke patients with follow up. Two (2%) patients died. Low baseline National Institutes of Health Stroke Scale score (P<0.0001) and younger age (P=0.007) were independent predictors of favorable outcome. CONCLUSIONS: sVAD is predominantly located in the pars transversaria (V2) or the atlas loop (V3). Most patients show posterior circulation ischemia. Favorable outcome is observed in most ischemic strokes and independently predicted by low National Institutes of Health Stroke Scale score and younger age.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cement augmentation using PMMA cement is known as an efficient treatment for osteoporotic vertebral compression fractures with a rapid release of pain in most patients and prevention of an ongoing kyphotic deformity of the vertebrae treated. However, after a vertebroplasty there is no chance to restore vertebral height. Using the technique of kyphoplasty a certain restoration of vertebral body height can be achieved. But there is a limitation of recovery due to loss of correction when deflating the kyphoplastic ballon and before injecting the cement. In addition, the instruments used are quite expensive. Lordoplasty is another technique to restore kyphosis by indirect fracture reduction as it is used with an internal fixateur. The fractured and the adjacent vertebrae are instrumented with bone cannulas bipediculary and the adjacent vertebrae are augmentated with cement. After curing of the cement the fractured vertebra is reduced by applying a lordotic moment via the cannulas. While maintaining the pretension the fractured vertebra is reinforced. We performed a prospective trial of 26 patients with a lordoplastic procedure. There was a pain relief of about 87% and a significant decrease in VAS value from 7.3 to 1.9. Due to lordoplasty there was a significant and permanent correction in vertebral and segmental kyphotic angle about 15.2 degrees and 10.0 degrees , respectively and also a significant restoration in anterior and mid vertebral height. Lordoplasty is a minimal invasive technique to restore vertebral body height. An immediate relief of pain is achieved in most patients. The procedure is safe and cost effective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine the association between the 3-dimensional (3-D) motion pattern of the caudal lumbar and lumbosacral portions of the canine vertebral column and the morphology of vertebrae, facet joints, and intervertebral disks. SAMPLE POPULATION: Vertebral columns of 9 German Shepherd Dogs and 16 dogs of other breeds with similar body weights and body conditions. PROCEDURE: Different morphometric parameters of the vertebral column were assessed by computed tomography (CT) and magnetic resonance imaging. Anatomic conformation and the 3-D motion pattern were compared, and correlation coefficients were calculated. RESULTS: Total range of motion for flexion and extension was mainly associated with the facet joint angle, the facet joint angle difference between levels of the vertebral column in the transverse plane on CT images, disk height, and lever arm length. CONCLUSIONS AND CLINICAL RELEVANCE: Motion is a complex process that is influenced by the entire 3-D conformation of the lumbar portion of the vertebral column. In vivo dynamic measurements of the 3-D motion pattern of the lumbar and lumbosacral portions of the vertebral column will be necessary to further assess biomechanics that could lead to disk degeneration in dogs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Autogenous iliac crest has long served as the gold standard for anterior lumbar arthrodesis although added morbidity results from the bone graft harvest. Therefore, femoral ring allograft, or cages, have been used to decrease the morbidity of iliac crest bone harvesting. More recently, an experimental study in the animal showed that harvesting local bone from the anterior vertebral body and replacing the void by a radio-opaque beta-tricalcium phosphate plug was a valid concept. However, such a concept precludes theoretically the use of posterior pedicle screw fixation. At one institution a consecutive series of 21 patients underwent single- or multiple-level circumferential lumbar fusion with anterior cages and posterior pedicle screws. All cages were filled with cancellous bone harvested from the adjacent vertebral body, and the vertebral body defect was filled with a beta-tricalcium phosphate plug. The indications for surgery were failed conservative treatment of a lumbar degenerative disc disease or spondylolisthesis. The purpose of this study, therefore, was to report on the surgical technique, operative feasibility, safety, benefits, and drawbacks of this technique with our primary clinical experience. An independent researcher reviewed all data that had been collected prospectively from the onset of the study. The average age of the patients was 39.9 (26-57) years. Bone grafts were successfully harvested from 28 vertebral bodies in all but one patient whose anterior procedure was aborted due to difficulty in freeing the left common iliac vein. This case was converted to a transforaminal interbody fusion (TLIF). There was no major vascular injury. Blood loss of the anterior procedure averaged 250 ml (50-350 ml). One tricalcium phosphate bone plug was broken during its insertion, and one endplate was broken because of wrong surgical technique, which did not affect the final outcome. One patient had a right lumbar plexopathy that was not related to this special technique. There was no retrograde ejaculation, infection or pseudoarthrosis. One patient experienced a deep venous thrombosis. At the last follow up (mean 28 months) all patients had a solid lumbar spine fusion. At the 6-month follow up, the pain as assessed on the visual analog scale (VAS) decreased from 6.9 to 4.5 (33% decrease), and the Oswestry disability index (ODI) reduced from 48.0 to 31.7 with a 34% reduction. However, at 2 years follow up there was a trend for increase in the ODI (35) and VAS (5). The data in this study suggest that harvesting a cylinder of autograft from the adjacent vertebral body is safe and efficient. Filling of the void defect with a beta-tricalcium phosphate plug does not preclude the use of posterior pedicle screw stabilization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PMMA is the most common bone substitute used for vertebroplasty. An increased fracture rate of the adjacent vertebrae has been observed after vertebroplasty. Decreased failure strength has been noted in a laboratory study of augmented functional spine units (FSUs), where the adjacent, non-augmented vertebral body always failed. This may provide evidence that rigid cement augmentation may facilitate the subsequent collapse of the adjacent vertebrae. The purpose of this study was to evaluate whether the decrease in failure strength of augmented FSUs can be avoided using low-modulus PMMA bone cement. In cadaveric FSUs, overall stiffness, failure strength and stiffness of the two vertebral bodies were determined under compression for both the treated and untreated specimens. Augmentation was performed on the caudal vertebrae with either regular or low-modulus PMMA. Endplate and wedge-shaped fractures occurred in the cranial and caudal vertebrae in the ratios endplate:wedge (cranial:caudal): 3:8 (5:6), 4:7 (7:4) and 10:1 (10:1) for control, low-modulus and regular cement group, respectively. The mean failure strength was 3.3 +/- 1 MPa with low-modulus cement, 2.9 +/- 1.2 MPa with regular cement and 3.6 +/- 1.3 MPa for the control group. Differences between the groups were not significant (p = 0.754 and p = 0.375, respectively, for low-modulus cement vs. control and regular cement vs. control). Overall FSU stiffness was not significantly affected by augmentation. Significant differences were observed for the stiffness differences of the cranial to the caudal vertebral body for the regular PMMA group to the other groups (p < 0.003). The individual vertebral stiffness values clearly showed the stiffening effect of the regular cement and the lesser alteration of the stiffness of the augmented vertebrae using the low-modulus PMMA compared to the control group (p = 0.999). In vitro biomechanical study and biomechanical evaluation of the hypothesis state that the failure strength of augmented functional spine units could be better preserved using low-modulus PMMA in comparison to regular PMMA cement.