24 resultados para Chromia loaded sulfated titania


Relevância:

20.00% 20.00%

Publicador:

Resumo:

To maintain a tumour vasculature in proportion of the tumour growth, the endothelial cells proliferate and up-regulate the expression of the VEGF receptor 2 (VEGFR-2), whose expression is restricted to this cell type. This specificity implies that one therapeutically target the tumour endothelium. We investigated the use of immunoliposomes (IL), containing conjugated Fab' fragments of the monoclonal rat anti-VEGFR-2 antibody DC101 (DC101-IL) to cargo doxorubicin to the tumour endothelium. In vitro, fluorescein-labelled IL displayed a 7 fold better binding to VEGFR-2-positive 293T cells in comparison to unspecific liposomes. Balb/C mice were injected subcutaneously with syngeneic hepatocellular carcinoma cells. One set of animals was treated with DC101-IL filled with doxorubicin when the tumours were bigger than 400 mm3. A specific delivery of doxorubicin to endothelial cells of the tumour vessels could be demonstrated by the red fluorescence of doxorubicin with laser scanning microscopy, but neither a delay of tumour growth nor a shrinking of the tumour mass was observed. Yet necrosis in the tumours treated with doxorubicin containing vehicles was larger than in the tumours of the control groups. A second set of animals was treated with DC101-IL filled with doxorubicin when the tumours were smaller than 1 mm3. DC101-IL filled with doxorubicin led to a significant delay in tumour growth up to 7 weeks compared to empty DC101-IL, free doxorubicin, and HEPES/Glucose (HEPES/Glucose vs. DOX-DC101-IL, p = 0.001; unpaired, two-tailed Student's t-test) and to a higher amount of necrotic areas in the tumours (p = 0.053; 1 way ANOVA with 4 groups). These findings suggest that IL designed to bind specifically to VEGFR-2 can be used to deliver doxorubicin to the tumour endothelium and may impair the "angiogenic switch" of the tumours.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: One way to evaluate various implant restorations is to measure the amount of bone change that occurs at the crestal bone. The objective of this study was to histologically evaluate the alveolar bone change around a bone-level, non-matching implant-abutment diameter configuration that incorporated a horizontal offset and a Morse taper internal connection. METHODS: The study design included extraction of all mandibular premolars and first molars in five canines. After 3 months, 12 dental implants were placed at three levels in each dog: even with the alveolar crest, 1 mm above the alveolar crest, and 1 mm below the alveolar crest. The implants were submerged on one side of the mandible. On the other side, healing abutments were exposed to the oral cavity (non-submerged). Gold crowns were attached 2 months after implant placement. The dogs were sacrificed 6 months postloading, and specimens were processed for histologic and histometric analyses. RESULTS: Evaluation of the specimens indicated that the marginal bone remained near the top of the implants under submerged and non-submerged conditions. The amount of bone change for submerged implants placed even with, 1 mm below, and 1 mm above the alveolar crest was -0.34, -1.29, and 0.04 mm, respectively (negative values indicate bone loss). For non-submerged implants, the respective values were -0.38, -1.13, and 0.19 mm. For submerged and non-submerged implants, there were significant differences in the amount of bone change among the three groups (P <0.05). The percentage of bone-to-implant contact for submerged implants was 73.3%, 71.8%, and 71.5%. For non-submerged implants, the respective numbers were 73.2%, 74.5%, and 76%. No significant differences occurred with regard to the percentage of bone contact. CONCLUSIONS: Minimal histologic bone loss occurred when dental implants with non-matching implant-abutment diameters were placed at the bone crest and were loaded for 6 months in the canine. The bone loss was significantly less (five- to six-fold) than that reported for bone-level implants with matching implant-abutment diameters (butt-joint connections).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Indocyanine green (ICG) is a chemically labile compound which needs to be stabilized in aqueous media to be used in biomedical applications. In the present study, poly(ε-caprolactone) (PCL), a semi-crystalline polyester, was used to encapsulate and stabilize ICG in a hydrophobic environment. A hydrophobic and biocompatible nanocomposite was obtained by the process of encapsulating inorganic silica. ICG was embedded in the hydrophobic polymer coating by starting from a well-defined silica (Si) core of either 80 nm or 120 nm diameter, which served as a template for a ‘grafting from’ approach using ε-caprolactone. The obtained nanocomposite Si grafted PCL/ICG was based on silica nanoparticles grafted with PCL, in which ICG was adsorbed. The nanoparticles were characterized by IR spectroscopy, thermogravimetric analysis (TGA) and scanning electron microscopy (SEM). The change in the surface charge and the colloidal stability of the nanoparticles was followed by zeta potential measurements. This approach of synthesizing nanocomposite-based ICG demonstrates a new route to stabilize ICG. We synthesized biocompatible nanoparticles containing a high ICG concentration and exhibiting excellent stability to aqueous decomposition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Quantitative computer tomography (QCT)-based finite element (FE) models of vertebral body provide better prediction of vertebral strength than dual energy X-ray absorptiometry. However, most models were validated against compression of vertebral bodies with endplates embedded in polymethylmethalcrylate (PMMA). Yet, loading being as important as bone density, the absence of intervertebral disc (IVD) affects the strength. Accordingly, the aim was to assess the strength predictions of the classic FE models (vertebral body embedded) against the in vitro and in silico strengths of vertebral bodies loaded via IVDs. High resolution peripheral QCT (HR-pQCT) were performed on 13 segments (T11/T12/L1). T11 and L1 were augmented with PMMA and the samples were tested under a 4° wedge compression until failure of T12. Specimen-specific model was generated for each T12 from the HR-pQCT data. Two FE sets were created: FE-PMMA refers to the classical vertebral body embedded model under axial compression; FE-IVD to their loading via hyperelastic IVD model under the wedge compression as conducted experimentally. Results showed that FE-PMMA models overestimated the experimental strength and their strength prediction was satisfactory considering the different experimental set-up. On the other hand, the FE-IVD models did not prove significantly better (Exp/FE-PMMA: R²=0.68; Exp/FE-IVD: R²=0.71, p=0.84). In conclusion, FE-PMMA correlates well with in vitro strength of human vertebral bodies loaded via real IVDs and FE-IVD with hyperelastic IVDs do not significantly improve this correlation. Therefore, it seems not worth adding the IVDs to vertebral body models until fully validated patient-specific IVD models become available.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vertebral compression fracture is a common medical problem in osteoporotic individuals. The quantitative computed tomography (QCT)-based finite element (FE) method may be used to predict vertebral strength in vivo, but needs to be validated with experimental tests. The aim of this study was to validate a nonlinear anatomy specific QCT-based FE model by using a novel testing setup. Thirty-seven human thoracolumbar vertebral bone slices were prepared by removing cortical endplates and posterior elements. The slices were scanned with QCT and the volumetric bone mineral density (vBMD) was computed with the standard clinical approach. A novel experimental setup was designed to induce a realistic failure in the vertebral slices in vitro. Rotation of the loading plate was allowed by means of a ball joint. To minimize device compliance, the specimen deformation was measured directly on the loading plate with three sensors. A nonlinear FE model was generated from the calibrated QCT images and computed vertebral stiffness and strength were compared to those measured during the experiments. In agreement with clinical observations, most of the vertebrae underwent an anterior wedge-shape fracture. As expected, the FE method predicted both stiffness and strength better than vBMD (R2 improved from 0.27 to 0.49 and from 0.34 to 0.79, respectively). Despite the lack of fitting parameters, the linear regression of the FE prediction for strength was close to the 1:1 relation (slope and intercept close to one (0.86 kN) and to zero (0.72 kN), respectively). In conclusion, a nonlinear FE model was successfully validated through a novel experimental technique for generating wedge-shape fractures in human thoracolumbar vertebrae.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The microporous material Ionsiv is used for 137Cs removal from aqueous nuclear waste streams. In the UK, Cs-loaded Ionsiv is classed as an intermediate-level waste; no sentencing and disposal route is yet defined for this material and it is currently held in safe interim storage on several nuclear sites. In this study, the suitability of fly ash and blast furnace slag blended cements for encapsulation of Cs-Ionsiv in a monolithic wasteform was investigated. No evidence of reaction or dissolution of the Cs-Ionsiv in the cementitious environment was found by scanning electron microscopy and X-ray diffraction. However, a small fraction (<= 1.6 wt.%) of the Cs inventory was released from the encapsulated Ionsiv during leaching experiments carried out on hydrated samples. Furthermore, it was evident that K and Na present in the cementitious pore water exchanged with Cs and H in the Ionsiv. Therefore, cement systems lower in K and Na, such as slag based cements, showed lower Cs release than the fly ash based cements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES The aim of this study was to assess the safety of the concurrent administration of a clopidogrel and prasugrel loading dose in patients undergoing primary percutaneous coronary intervention. BACKGROUND Prasugrel is one of the preferred P2Y12 platelet receptor antagonists for ST-segment elevation myocardial infarction patients. The use of prasugrel was evaluated clinically in clopidogrel-naive patients. METHODS Between September 2009 and October 2012, a total of 2,023 STEMI patients were enrolled in the COMFORTABLE (Comparison of Biomatrix Versus Gazelle in ST-Elevation Myocardial Infarction [STEMI]) and the SPUM-ACS (Inflammation and Acute Coronary Syndromes) studies. Patients receiving a prasugrel loading dose were divided into 2 groups: 1) clopidogrel and a subsequent prasugrel loading dose; and 2) a prasugrel loading dose. The primary safety endpoint was Bleeding Academic Research Consortium types 3 to 5 bleeding in hospital at 30 days. RESULTS Of 2,023 patients undergoing primary percutaneous coronary intervention, 427 (21.1%) received clopidogrel and a subsequent prasugrel loading dose, 447 (22.1%) received a prasugrel loading dose alone, and the remaining received clopidogrel only. At 30 days, the primary safety endpoint was observed in 1.9% of those receiving clopidogrel and a subsequent prasugrel loading dose and 3.4% of those receiving a prasugrel loading dose alone (adjusted hazard ratio [HR]: 0.57; 95% confidence interval [CI]: 0.25 to 1.30, p = 0.18). The HAS-BLED (hypertension, abnormal renal/liver function, stroke, bleeding history or predisposition, labile international normalized ratio, elderly, drugs/alcohol concomitantly) bleeding score tended to be higher in prasugrel-treated patients (p = 0.076). The primary safety endpoint results, however, remained unchanged after adjustment for these differences (clopidogrel and a subsequent prasugrel loading dose vs. prasugrel only; HR: 0.54 [95% CI: 0.23 to 1.27], p = 0.16). No differences in the composite of cardiac death, myocardial infarction, or stroke were observed at 30 days (adjusted HR: 0.66, 95% CI: 0.27 to 1.62, p = 0.36). CONCLUSIONS This observational, nonrandomized study of ST-segment elevation myocardial infarction patients suggests that the administration of a loading dose of prasugrel in patients pre-treated with a loading dose of clopidogrel is not associated with an excess of major bleeding events. (Comparison of Biomatrix Versus Gazelle in ST-Elevation Myocardial Infarction [STEMI] [COMFORTABLE]; NCT00962416; and Inflammation and Acute Coronary Syndromes [SPUM-ACS]; NCT01000701).