63 resultados para CLOCK


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite antibiotic therapy and supportive intensive medical care, bacterial meningitis remains a disease with high mortality and morbidity. Rapid recognition of symptoms is crucial to direct physicians quickly towards appropriate diagnostic measures and, initially, empiric antibiotic therapy. It has become evident that time from arrival at the hospital to application of the first dose of antibiotics is a crucial independent factor that influences outcome. Here, we review the clinical and laboratory presentation of community-acquired bacterial meningitis and the antibiotic regiments that are currently recommended for its treatment; future therapeutic options are also discussed. Finally, suggestions for the approach to a patient with suspected bacterial meningitis are presented.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Besides the master clock located in the suprachiasmatic nucleus (SCN) of the brain, additional clocks are distributed across the central nervous system and the body. The role of these 'secondary' clocks remains unclear. A new study shows that the lack of an internal clock in histamine neurons profoundly perturbs sleep.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Multi-GNSS Experiment (MGEX) of the International GNSS Service (IGS) aims at the data collection and analysis of all available satellite navigation systems. In particular the new global and regional satellite navigation systems are of interest, i.e., the European Galileo, the Chinese BeiDou, the Japanese QZSS as well as satellite based augmentation systems. This article analyzes the orbit and clock quality of the Galileo products of four MGEX analysis centers for a common time period of 20 weeks. Orbit comparisons of the individual analysis centers have a consistency at the 5–30 cm level. Day boundary discontinuities range from 4 to 28 cm whereas 2-day orbit fit RMS values vary between 1 and 7 cm. The accuracy evaluated by satellite laser ranging residuals is on the one decimeter level with a systematic bias of about −5 cm for all analysis centers. In addition, systematic errors on the decimeter level related to solar radiation pressure mismodeling are present in all orbit products. Due to the correlation of radial orbit errors with the clock parameters, these errors are also visible as a bump in the Allan deviation of the Galileo satellite clocks at the orbital frequency.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Performance on interval timing is often explained by the assumption of an internal clock based on neural counting. According to this account, a neural pacemaker generates pulses, and the number of pulses relating to a physical time interval is recorded by a counter. Thus, the number of accumulated pulses is the internal representation of this interval. Several studies demonstrated that large visual stimuli are perceived to last longer than smaller ones presented for the same duration. The present study was designed to investigate whether nontemporal visual stimulus size directly affects the internal clock. For this purpose, a temporal reproduction task was applied. Sixty participants were randomly assigned to one of two experimental conditions with stimulus size being experimentally varied within either the target or the reproduction interval. A direct effect of nontemporal stimulus size on the pacemaker-counter system should become evident irrespective of whether stimulus size was experimentally varied within the target or the reproduction interval. An effect of nontemporal stimulus size on reproduced duration only occurred when stimulus size was varied during the target interval. This finding clearly argues against the notion that nontemporal visual stimulus size directly affects the internal clock. Furthermore, our findings ruled out a decisional bias as a possible cause of the observed differential effect of stimulus size on reproduced duration. Rather the effect of stimulus size appeared to originate from the memory stage of temporal information processing at which the timing signal from the pacemaker-counter component is encoded in reference memory.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Center for Orbit Determination in Europe (CODE) is contributing as a global Analysis center to the International GNSS Service (IGS) since many years. The processing of GPS and GLONASS data is well established in CODE’s ultra-rapid, rapid, and final product lines. With the introduction of new signals for the established and new GNSS, new challenges and opportunities are arising for the GNSS data management and processing. The IGS started the Multi-GNSS-EXperiment (MGEX) in 2012 in order to gain first experience with the new data formats and to develop new strategies for making optimal use of these additional measurements. CODE has started to contribute to IGS MGEX with a consistent, rigorously combined triple-system orbit solution (GPS, GLONASS, and Galileo). SLR residuals for the computed Galileo satellite orbits are of the order of 10 cm. Furthermore CODE established a GPS and Galileo clock solution. A quality assessment shows that these experimental orbit and clock products allow even a Galileo-only precise point positioning (PPP) with accuracies on the decimeter- (static PPP) to meter-level (kinematic PPP) for selected stations.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Melatonin is an important endocrine signal for darkness in mammals. Transcriptional activation of the arylalkylamine-N-acetyltransferase gene encoding for the penultimate enzyme in melatonin synthesis drives the daily rhythm of the hormone in the pineal gland of rodents. Rhythmic arylalkylamine-N-acetyltransferase expression is controlled by the cAMP-signal transduction pathway and involves the activation of ?-adrenergic receptors and the inducible cAMP early repressor. In addition, the rat arylalkylamine-N-acetyltransferase promoter contains an E-box element which can interact with clock proteins. Moreover, the pineal gland of mice shows a circadian rhythm in clock proteins such as the transcriptional repressor Period1, which has been shown to control rhythmic gene expression in a variety of tissues. However, the role of Period1 in the regulation of pineal melatonin synthesis is still unknown. Therefore, circadian rhythms in arylalkylamine-N-acetyltransferase, ?-adrenergic receptor, and inducible cAMP early repressor mRNA levels (real time PCR), arylalkylamine-N-acetyltransferase enzyme activity (radiometric assay) and melatonin concentration radio immuno assay (RIA) were analyzed in the pineal gland of mice with a targeted deletion of the Period1 gene (Per1-/-) and the corresponding wildtype. In Per1-/- the amplitude in arylalkylamine-N-acetyltransferase expression was significantly elevated as compared to wildtype. In contrast, ?-adrenergic receptor and inducible cAMP early repressor mRNA levels were not affected by the Period1-deficiency. This indicates that the molecular clockwork alters the amplitude of arylalkylamine-N-acetyltransferase expression. In vitro, pineal glands of Per1-/- mice showed a day night difference in arylalkylamine-N-acetyltransferase expression with high levels at night. This suggests that a deficient in Period1 elicits similar effects as the activation of the cAMP-signal transduction pathway in wildtype mice.