45 resultados para Brasil [Lei n. 11.107, de 6 de abril de 2005]
Resumo:
Ultrasound is an emerging new imaging and guiding technique for diagnostic or therapeutic interventional pain procedures. Advantages are the real time monitoring of the targeted structures, the placement of the instruments and the visualization of local anaesthetic spread without exposing patients and personal to radiation. Pain specialists need a large anatomical knowledge and training to use the new method safely and distinctively. The increasing published data available and the personal experience of the authors suggest a potential usefulness in interventional pain therapy, but also limitations.
Resumo:
CONTEXT: Determination of arginine vasopressin (AVP) concentrations may be helpful to guide therapy in critically ill patients. A new assay analyzing copeptin, a stable peptide derived from the AVP precursor, has been introduced. OBJECTIVE: Our objective was to determine plasma copeptin concentrations. DESIGN: We conducted a post hoc analysis of plasma samples and data from a prospective study. SETTING: The setting was a 12-bed general and surgical intensive care unit (ICU) in a tertiary university teaching hospital. PATIENTS: Our subjects were 70 healthy volunteers and 157 ICU patients with sepsis, with systemic inflammatory response syndrome (SIRS), and after cardiac surgery. INTERVENTIONS: There were no interventions. MAIN OUTCOME MEASURES: Copeptin plasma concentrations, demographic data, AVP plasma concentrations, and a multiple organ dysfunction syndrome score were documented 24 h after ICU admission. RESULTS: AVP (P < 0.001) and copeptin (P < 0.001) concentrations were significantly higher in ICU patients than in controls. Patients after cardiac surgery had higher AVP (P = 0.003) and copeptin (P = 0.003) concentrations than patients with sepsis or SIRS. Independent of critical illness, copeptin and AVP correlated highly significantly with each other. Critically ill patients with sepsis and SIRS exhibited a significantly higher ratio of copeptin/AVP plasma concentrations than patients after cardiac surgery (P = 0.012). The American Society of Anesthesiologists' classification (P = 0.046) and C-reactive protein concentrations (P = 0.006) were significantly correlated with the copeptin/AVP ratio. CONCLUSIONS: Plasma concentrations of copeptin and AVP in healthy volunteers and critically ill patients correlate significantly with each other. The ratio of copeptin/AVP plasma concentrations is increased in patients with sepsis and SIRS, suggesting that copeptin may overestimate AVP plasma concentrations in these patients.
Resumo:
The clinical impact and outcome of a rare radiographic finding of hepatic portal venous gas (HPVG) as well as the effectiveness of computed tomography (CT), CT scanogram, and conventional radiography in the detection of HPVG were retrospectively analyzed. CT scans, CT scanogram, and plain film radiographs of 11 patients with HPVG were reviewed and compared with their medical records and surgical and pathology reports. Eight of the 11 patients underwent plain film radiographs 1 day before or after the CT scan. HPVG was detected at CT in all 11 patients, on CT scanogram in three (3 of 11, 27.3%), and on plain films in one (one of eight, 12.5%). In nine of 11 patients (81.8%), CT revealed an associated pneumatosis intestinalis. In six of the 11 patients (54.6%), acute mesenteric ischemia was the underlying disease for HPVG. Seven patients (63.6%) underwent emergency exploratory laparotomy. The mortality rate for HPVG alone was 27.3% (3 of 11) and for HPVG related to mesenteric bowel disease 50% (three of six). Acute mesenteric ischemia is the most common cause of HPVG, which continues to have a predictably higher mortality. CT is superior to CT scanograms and radiographs in the detection of HPVG and its underlying diseases and, therefore, should be used as the primary diagnostic tool.
Resumo:
A novel computer-assisted injection device for the delivery of highly viscous bone cements in vertebroplasty is presented. It addresses the shortcomings of manual injection systems ranging from low-pressure and poor level of control to device failure. The presented instrument is capable of generating a maximum pressure of 5000 kPa in traditional 6-ml syringes and provides an advanced control interface for precise cement delivery from outside radiation fields emitted by intraoperative imaging systems. The integrated real-time monitoring of injection parameters, such as flow-rate, volume, pressure, and viscosity, simplifies consistent documentation of interventions and establishes a basis for the identification of safe injection protocols on the longer term. Control algorithms prevent device failure due to overloading and provide means to immediately stop cement flow to avoid leakage into adjacent tissues.
Resumo:
Different types of titanium-alloys instead of CoCr-alloys have been tested as material for the framework of removable partial dentures (RPD). Adequate casting and processing techniques have been developed which enable to fabricate frameworks of complex designs and the problem limits porosity. This opened new possibilities for the use of titanium-alloys with improved properties (E-module). The aim of this study was to summarise the use of titanium in removable prosthodontics and to evaluate prospectively the use of the Ti6A17Nb-alloy for RPDs in a small group of patients. Two identically designed RPDs from CoCr-alloy (remanium GM 800+) and Ti6A17Nb-alloy (girotan L) were produced for ten patients. They had to wear each RPD during six months, first the CoCr-RPD and then the Ti6A17Nb-RPD. A questionnaire (visual analogue scale = VAS) was completed by the patients after one, three and six months of function for each RPD. Prosthetic complications and service needed were recorded. After the end of the entire observation period of twelve months, the patients remained with the Ti6A17Nb-RPD and answered the questionnaire after another six months. All parameters regarding the design of the RPDs were positively estimated by the dentist. Minimal, not significant differences were noted by the patients concerning comfort, stability and retention (VAS). Clinically, no differences in technical aspects or regarding biological complications were observed after six-months periods. The Ti6A17Nb-alloy (girotan L) for the framework of RPDs was judged by patients and professionals to be equivalent to RPDs made from CoCr-alloy. No differences in material aspects could objectively be observed. The Ti6A17Nb-alloy can be beneficial for patients with allergies or incompatibility with one or several components of the CoCr-alloy.
Resumo:
AIMS: Recent studies of drug-eluting stents for unprotected left main coronary artery (LMCA) disease have been encouraging. We examined the performance of sirolimus-eluting stents (SES) for this indication. METHODS AND RESULTS: This retrospective study included 228 consecutive patients (mean age = 68 +/- 11 years, 80.6% men, 26.3% diabetics) who underwent implantation of SES for de novo LMCA stenoses. The mean additive and logistic EuroSCOREs were 5.2 +/- 3.9 and 8.2 +/- 13.2, respectively. The main objective of this study was to measure the rate of major adverse cardiac events (MACE), including death, myocardial infarction and target lesion revascularisation (TLR) at 12 months. Other objectives were to measure the rates of in-hospital MACE and 12-month TLR. Outcomes in 143 patients with (BIF+ group), versus 84 patients without (BIF-group) involvement of the bifurcation were compared. The pre-procedural percent diameter stenosis (%DS) was 60.1 +/- 11.2 in the BIF+ versus 54.7 +/- 12.2% in the BIF- group (p=0.008), and decreased to 18.0 +/- 9.7 and 13.9 +/- 11.3%, respectively (ns), after SES implant. The overall in-hospital MACE rate was 3.5%, and similar in both subgroups. The 1-year MACE rate was 14.5% overall, 16.8% in the BIF+ and 10.7% in the BIF- subgroup (ns). CONCLUSIONS: SES implants in high-risk patients with LMCA stenoses were associated with a low 1-year MACE rate. Stenting of the bifurcation was associated with significant increases in neither mortality nor 1-year MACE rate.
Resumo:
OBJECTIVE: To clarify the role of the pulmonary artery catheter in the intensive care unit. DATA SOURCES: Recent and relevant literature from MEDLINE and authors' personal databases. STUDY SELECTION: Studies on pulmonary artery catheter use and use of other monitoring devices in critically ill patients. DATA EXTRACTION: Based largely on clinical experience and assessment of the relevant published literature and in response to recent articles attacking the pulmonary artery catheter, we propose that the pulmonary artery catheter is still a valuable tool for the hemodynamic monitoring of patients with complex disease processes in whom the information obtained from the pulmonary artery catheter may influence management. We suggest that there is a need to revisit the basics of hemodynamic management and reassess the way in which the pulmonary artery catheter is used, applying three key principles: correct measurement, correct data interpretation, and correct application. CONCLUSION: The pulmonary artery catheter is still a valuable tool for hemodynamic monitoring when used in selected patients and by physicians adequately trained to correctly interpret and apply the data provided.
Resumo:
BACKGROUND: This study analyzed the impact of weight reduction method, preoperative, and intraoperative variables on the outcome of reconstructive body contouring surgery following massive weight reduction. METHODS: All patients presenting with a maximal BMI >/=35 kg/m(2) before weight reduction who underwent body contouring surgery of the trunk following massive weight loss (excess body mass index loss (EBMIL) >/= 30%) between January 2002 and June 2007 were retrospectively analyzed. Incomplete records or follow-up led to exclusion. Statistical analysis focused on weight reduction method and pre-, intra-, and postoperative risk factors. The outcome was compared to current literature results. RESULTS: A total of 104 patients were included (87 female and 17 male; mean age 47.9 years). Massive weight reduction was achieved through bariatric surgery in 62 patients (59.6%) and dietetically in 42 patients (40.4%). Dietetically achieved excess body mass index loss (EBMIL) was 94.20% and in this cohort higher than surgically induced reduction EBMIL 80.80% (p < 0.01). Bariatric surgery did not present increased risks for complications for the secondary body contouring procedures. The observed complications (26.9%) were analyzed for risk factors. Total tissue resection weight was a significant risk factor (p < 0.05). Preoperative BMI had an impact on infections (p < 0.05). No impact on the postoperative outcome was detected in EBMIL, maximal BMI, smoking, hemoglobin, blood loss, body contouring technique or operation time. Corrective procedures were performed in 11 patients (10.6%). The results were compared to recent data. CONCLUSION: Bariatric surgery does not increase risks for complications in subsequent body contouring procedures when compared to massive dietetic weight reduction.
Resumo:
Renal dysfunction represents a frequent comorbidity in patients with in chronic heart failure and is not only a strong predictor of mortality, but also causally linked to the development and progression of CHF. Mechanisms involved in the cross-talk between the kidney and the heart include the up-regulated sympathetic nerve system, activation of the renin-angiotensin-aldosterone system, vasopressin release and decreased activity of arterial baroreceptors and natriuretic peptides resulting in abnormal salt and water retention. The main therapeutic goals for patients with the so-called cardiorenal syndrome is the normalization of volume status while avoiding overdiuresis and renal dysfunction as well as the implementation of an evidence-based pharmacologic treatment to improve patient outcome. If these two goals are not achieved with conventional therapy, renal replacement therapy should be discussed in an interdisciplinary approach. All current renal replacement techniques have proved to be useful in controlling hypervolemia and ameliorating functional cardiac parameters and quality of life in patients with heart failure. Nevertheless, the influence of renal replacement therapy on long-term survival of affected patients has not been addressed in large controlled studies.