24 resultados para Box girder bridges Design and construction Evaluation Data processing


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Short-acting agents for neuromuscular block (NMB) require frequent dosing adjustments for individual patient's needs. In this study, we verified a new closed-loop controller for mivacurium dosing in clinical trials. METHODS: Fifteen patients were studied. T1% measured with electromyography was used as input signal for the model-based controller. After induction of propofol/opiate anaesthesia, stabilization of baseline electromyography signal was awaited and a bolus of 0.3 mg kg-1 mivacurium was then administered to facilitate endotracheal intubation. Closed-loop infusion was started thereafter, targeting a neuromuscular block of 90%. Setpoint deviation, the number of manual interventions and surgeon's complaints were recorded. Drug use and its variability between and within patients were evaluated. RESULTS: Median time of closed-loop control for the 11 patients included in the data processing was 135 [89-336] min (median [range]). Four patients had to be excluded because of sensor problems. Mean absolute deviation from setpoint was 1.8 +/- 0.9 T1%. Neither manual interventions nor complaints from the surgeons were recorded. Mean necessary mivacurium infusion rate was 7.0 +/- 2.2 microg kg-1 min-1. Intrapatient variability of mean infusion rates over 30-min interval showed high differences up to a factor of 1.8 between highest and lowest requirement in the same patient. CONCLUSIONS: Neuromuscular block can precisely be controlled with mivacurium using our model-based controller. The amount of mivacurium needed to maintain T1% at defined constant levels differed largely between and within patients. Closed-loop control seems therefore advantageous to automatically maintain neuromuscular block at constant levels.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To develop and evaluate a short form of the 24-item Geriatric Pain Measure (GPM) for use in community-dwelling older adults. DESIGN: Derivation and validation of a 12-item version of the GPM in a European and an independent U.S. sample of community-dwelling older adults. SETTING: Three community-dwelling sites in London, United Kingdom; Hamburg, Germany; Solothurn, Switzerland; and two ambulatory geriatrics clinics in Los Angeles, California. PARTICIPANTS: European sample: 1,059 community-dwelling older persons from three sites (London, UK; Hamburg, Germany; Solothurn, Switzerland); validation sample: 50 persons from Los Angeles, California, ambulatory geriatric clinics. MEASUREMENTS: Multidimensional questionnaire including self-reported demographic and clinical information. RESULTS: Based on item-to-total scale correlations in the European sample, 11 of 24 GPM items were selected for inclusion in the short form. One additional item (pain-related sleep problems) was included based on clinical relevance. In the validation sample, the Cronbach alpha of GPM-12 was 0.92 (individual subscale range 0.77-0.92), and the Pearson correlation coefficient (r) between GPM-12 and the original GPM was 0.98. The correlation between the GPM-12 and the McGill Pain Questionnaire was 0.63 (P<.001), similar to the correlation between the original GPM and the McGill Pain Questionnaire (Pearson r=0.63; P<.001). Exploratory factor analysis indicated that the GPM-12 covers three subfactors (pain intensity, pain with ambulation, disengagement because of pain). CONCLUSION: The GPM-12 demonstrated good validity and reliability in these European and U.S. populations of older adults. Despite its brevity, the GPM-12 captures the multidimensional nature of pain in three subscales. The self-administered GPM-12 may be useful in the clinical assessment process and management of pain and in pain-related research in older persons.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES Optical scanners combined with computer-aided design and computer-aided manufacturing (CAD/CAM) technology provide high accuracy in the fabrication of titanium (TIT) and zirconium dioxide (ZrO) bars. The aim of this study was to compare the precision of fit of CAD/CAM TIT bars produced with a photogrammetric and a laser scanner. METHODS Twenty rigid CAD/CAM bars were fabricated on one single edentulous master cast with 6 implants in the positions of the second premolars, canines and central incisors. A photogrammetric scanner (P) provided digitized data for TIT-P (n=5) while a laser scanner (L) was used for TIT-L (n=5). The control groups consisted of soldered gold bars (gold, n=5) and ZrO-P with similar bar design. Median vertical distance between implant and bar platforms from non-tightened implants (one-screw test) was calculated from mesial, buccal and distal scanning electron microscope measurements. RESULTS Vertical microgaps were not significantly different between TIT-P (median 16μm; 95% CI 10-27μm) and TIT-L (25μm; 13-32μm). Gold (49μm; 12-69μm) had higher values than TIT-P (p=0.001) and TIT-L (p=0.008), while ZrO-P (35μm; 17-55μm) exhibited higher values than TIT-P (p=0.023). Misfit values increased in all groups from implant position 23 (3 units) to 15 (10 units), while in gold and TIT-P values decreased from implant 11 toward the most distal implant 15. SIGNIFICANCE CAD/CAM titanium bars showed high precision of fit using photogrammetric and laser scanners. In comparison, the misfit of ZrO bars (CAM/CAM, photogrammetric scanner) and soldered gold bars was statistically higher but values were clinically acceptable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Contour augmentation around early-placed implants (Type 2 placement) using autogenous bone chips combined with deproteinized bovine bone mineral (DBBM) and a collagen barrier membrane has been documented to predictably provide esthetically satisfactory clinical outcomes. In addition, recent data from cone beam computed tomography studies have shown the augmented volume to be stable long-term. However, no human histologic data are available to document the tissue reactions to this bone augmentation procedure. METHODS Over an 8-year period, 12 biopsies were harvested 14 to 80 months after implant placement with simultaneous contour augmentation in 10 patients. The biopsies were subjected to histologic and histomorphometric analysis. RESULTS The biopsies consisted of 32.0% ± 9.6% DBBM particles and 40.6% ± 14.6% mature bone. 70.3% ± 14.5% of the DBBM particle surfaces were covered with bone. On the remaining surface, multinucleated giant cells with varying intensity of tartrate-resistant acid phosphatase staining were regularly present. No signs of inflammation were visible, and no tendency toward a decreasing volume fraction of DBBM over time was observed. CONCLUSIONS The present study confirms previous findings that osseointegrated DBBM particles do not tend to undergo substitution over time. This low substitution rate may be the reason behind the clinically and radiographically documented long-term stability of contour augmentation using a combination of autogenous bone chips, DBBM particles, and a collagen membrane.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to harness the unique properties of nanoparticles for novel clinical applications and to modulate their uptake into specific immune cells we designed a new library of homo- and hetero-functional fluorescence-encoded gold nanoparticles (Au-NPs) using different poly(vinyl alcohol) and poly(ethylene glycol)-based polymers for particle coating and stabilization. The encoded particles were fully characterized by UV-Vis and fluorescence spectroscopy, zeta potential and dynamic light scattering. The uptake by human monocyte derived dendritic cells in vitro was studied by confocal laser scanning microscopy and quantified by fluorescence-activated cell sorting and inductively coupled plasma atomic emission spectroscopy. We show how the chemical modification of particle surfaces, for instance by attaching fluorescent dyes, can conceal fundamental particle properties and modulate cellular uptake. In order to mask the influence of fluorescent dyes on cellular uptake while still exploiting its fluorescence for detection, we have created hetero-functionalized Au-NPs, which again show typical particle dependent cellular interactions. Our study clearly prove that the thorough characterization of nanoparticles at each modification step in the engineering process is absolutely essential and that it can be necessary to make substantial adjustments of the particles in order to obtain reliable cellular uptake data, which truly reflects particle properties.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis consists of four essays on the design and disclosure of compensation contracts. Essays 1, 2 and 3 focus on behavioral aspects of mandatory compensation disclosure rules and of contract negotiations in agency relationships. The three experimental studies develop psychology- based theory and present results that deviate from standard economic predictions. Furthermore, the results of Essay 1 and 2 also have implications for firms’ discretion in how to communicate their top management’s incentives to the capital market. Essay 4 analyzes the role of fairness perceptions for the evaluation of executive compensation. For this purpose, two surveys targeting representative eligible voters as well as investment professionals were conducted. Essay 1 investigates the role of the detailed ‘Compensation Discussion and Analysis’, which is part of the Security and Exchange Commission’s 2006 regulation, on investors’ evaluations of executive performance. Compensation disclosure complying with this regulation clarifies the relationship between realized reported compensation and the underlying performance measures and their target achievement levels. The experimental findings suggest that the salient presentation of executives’ incentives inherent in the ‘Compensation Discussion and Analysis’ makes investors’ performance evaluations less outcome dependent. Therefore, investors’ judgment and investment decisions might be less affected by noisy environmental factors that drive financial performance. The results also suggest that fairness perceptions of compensation contracts are essential for investors’ performance evaluations in that more transparent disclosure increases the perceived fairness of compensation and the performance evaluation of managers who are not responsible for a bad financial performance. These results have important practical implications as firms might choose to communicate their top management’s incentive compensation more transparently in order to benefit from less volatile expectations about their future performance. Similar to the first experiment, the experiment described in Essay 2 addresses the question of more transparent compensation disclosure. However, other than the first experiment, the second experiment does not analyze the effect of a more salient presentation of contract information but the informational effect of contract information itself. For this purpose, the experiment tests two conditions in which the assessment of the compensation contracts’ incentive compatibility, which determines executive effort, is either possible or not. On the one hand, the results suggest that the quality of investors’ expectations about executive effort is improved, but on the other hand investors might over-adjust their prior expectations about executive effort if being confronted with an unexpected financial performance and under-adjust if the financial performance confirms their prior expectations. Therefore, in the experiment, more transparent compensation disclosure does not lead to more correct overall judgments of executive effort and to even lower processing quality of outcome information. These results add to the literature on disclosure which predominantly advocates more transparency. The findings of the experiment however, identify decreased information processing quality as a relevant disclosure cost category. Firms might therefore carefully evaluate the additional costs and benefits of more transparent compensation disclosure. Together with the results from the experiment in Essay 1, the two experiments on compensation disclosure imply that firms should rather focus on their discretion how to present their compensation disclosure to benefit from investors’ improved fairness perceptions and their spill-over on performance evaluation. Essay 3 studies the behavioral effects of contextual factors in recruitment processes that do not affect the employer’s or the applicant’s bargaining power from a standard economic perspective. In particular, the experiment studies two common characteristics of recruitment processes: Pre-contractual competition among job applicants and job applicants’ non-binding effort announcements as they might be made during job interviews. Despite the standard economic irrelevance of these factors, the experiment develops theory regarding the behavioral effects on employees’ subsequent effort provision and the employers’ contract design choices. The experimental findings largely support the predictions. More specifically, the results suggest that firms can benefit from increased effort and, therefore, may generate higher profits. Further, firms may seize a larger share of the employment relationship’s profit by highlighting the competitive aspects of the recruitment process and by requiring applicants to make announcements about their future effort. Finally, Essay 4 studies the role of fairness perceptions for the public evaluation of executive compensation. Although economic criteria for the design of incentive compensation generally do not make restrictive recommendations with regard to the amount of compensation, fairness perceptions might be relevant from the perspective of firms and standard setters. This is because behavioral theory has identified fairness as an important determinant of individuals’ judgment and decisions. However, although fairness concerns about executive compensation are often stated in the popular media and even in the literature, evidence on the meaning of fairness in the context of executive compensation is scarce and ambiguous. In order to inform practitioners and standard setters whether fairness concerns are exclusive to non-professionals or relevant for investment professionals as well, the two surveys presented in Essay 4 aim to find commonalities in the opinions of representative eligible voters and investments professionals. The results suggest that fairness is an important criterion for both groups. Especially, exposure to risk in the form of the variable compensation share is an important criterion shared by both groups. The higher the assumed variable share, the higher is the compensation amount to be perceived as fair. However, to a large extent, opinions on executive compensation depend on personality characteristics, and to some extent, investment professionals’ perceptions deviate systematically from those of non-professionals. The findings imply that firms might benefit from emphasizing the riskiness of their managers’ variable pay components and, therefore, the findings are also in line with those of Essay 1.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

XENON is a dark matter direct detection project, consisting of a time projection chamber (TPC) filled with liquid xenon as detection medium. The construction of the next generation detector, XENON1T, is presently taking place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a sensitivity to spin-independent cross sections of 2 10-47 c 2 for WIMP masses around 50 GeV2, which requires a background reduction by two orders of magnitude compared to XENON100, the current generation detector. An active system that is able to tag muons and muon-induced backgrounds is critical for this goal. A water Cherenkov detector of ~ 10 m height and diameter has been therefore developed, equipped with 8 inch photomultipliers and cladded by a reflective foil. We present the design and optimization study for this detector, which has been carried out with a series of Monte Carlo simulations. The muon veto will reach very high detection efficiencies for muons (>99.5%) and showers of secondary particles from muon interactions in the rock (>70%). Similar efficiencies will be obtained for XENONnT, the upgrade of XENON1T, which will later improve the WIMP sensitivity by another order of magnitude. With the Cherenkov water shield studied here, the background from muon-induced neutrons in XENON1T is negligible.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cleverly designed molecular building blocks provide chemists with the tools of a powerful molecular-scale construction set. They enable them to engineer materials having a predictable order and useful solid-state properties. Hence, it is in the realm of supramolecular chemistry to follow a strategy for synthesizing materials which combine a selected set of properties, for instance from the areas of magnetism, photophysics and electronics. As a successful approach, host/guest solids which are based on extended anionic, homo- and bimetallic oxalato-bridged transition-metal compounds with two-and three-dimensional connectivities have been investigated. In this report, a brief review is given on the structural aspects of this class of compounds followed by a presentation of a thermal and magnetic study for two distinct, heterometallic oxalato-bridged layer compounds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Sutureless aortic valve replacement (SU-AVR) is an innovative approach which shortens cardiopulmonary bypass and cross-clamp durations and may facilitate minimally invasive approach. Evidence outlining its safety, efficacy, hemodynamic profile and potential complications is replete with small-volume observational studies and few comparative publications. METHODS Minimally invasive aortic valve surgery and high-volume SU-AVR replacement centers were contacted for recruitment into a global collaborative coalition dedicated to sutureless valve research. A Research Steering Committee was formulated to direct research and support the mission of providing registry evidence warranted for SU-AVR. RESULTS The International Valvular Surgery Study Group (IVSSG) was formed under the auspices of the Research Steering Committee, comprised of 36 expert valvular surgeons from 27 major centers across the globe. IVSSG Sutureless Projects currently proceeding include the Retrospective and Prospective Phases of the SU-AVR International Registry (SU-AVR-IR). CONCLUSIONS The global pooling of data by the IVSSG Sutureless Projects will provide required robust clinical evidence on the safety, efficacy and hemodynamic outcomes of SU-AVR.