23 resultados para Body image, form perception
Resumo:
The aim of this study was to investigate how oculomotor behaviour depends on the availability of colour information in pictorial stimuli. Forty study participants viewed complex images in colour or grey-scale, while their eye movements were recorded. We found two major effects of colour. First, although colour increases the complexity of an image, fixations on colour images were shorter than on their grey-scale versions. This suggests that colour enhances discriminability and thus affects low-level perceptual processing. Second, colour decreases the similarity of spatial fixation patterns between participants. The role of colour on visual attention seems to be more important than previously assumed, in theoretical as well as methodological terms.
Resumo:
The objective of this retrospective study was to assess image quality with pulmonary CT angiography (CTA) using 80 kVp and to find anthropomorphic parameters other than body weight (BW) to serve as selection criteria for low-dose CTA. Attenuation in the pulmonary arteries, anteroposterior and lateral diameters, cross-sectional area and soft-tissue thickness of the chest were measured in 100 consecutive patients weighing less than 100 kg with 80 kVp pulmonary CTA. Body surface area (BSA) and contrast-to-noise ratios (CNR) were calculated. Three radiologists analyzed arterial enhancement, noise, and image quality. Image parameters between patients grouped by BW (group 1: 0-50 kg; groups 2-6: 51-100 kg, decadally increasing) were compared. CNR was higher in patients weighing less than 60 kg than in the BW groups 71-99 kg (P between 0.025 and <0.001). Subjective ranking of enhancement (P = 0.165-0.605), noise (P = 0.063), and image quality (P = 0.079) did not differ significantly across all patient groups. CNR correlated moderately strongly with weight (R = -0.585), BSA (R = -0.582), cross-sectional area (R = -0.544), and anteroposterior diameter of the chest (R = -0.457; P < 0.001 all parameters). We conclude that 80 kVp pulmonary CTA permits diagnostic image quality in patients weighing up to 100 kg. Body weight is a suitable criterion to select patients for low-dose pulmonary CTA.
Resumo:
Gender-fair language, including women and men, such as word pairs has a substantial impact on the mental representation, as a large body of studies have shown. When using exclusively the masculine form as a generic, women are mentally significantly less represented than men. Word pairs, however, lead to a higher cognitive inclusion of women. Surprisingly little research has been conducted to understand how the perception of professional groups is affected by gender-fair language. Providing evidence from an Italian-Austrian cross-cultural study with over 400 participants, we argue that gender-fair language impacts the perception of professional groups, in terms of perceived gender-typicality, number of women and men assumed for a profession, social status and average income. Results hint at a pervasive pay-off: on the one hand, gender-fair language seems to boost the mental representations in favor of women and professions are perceived as being rather gender-neutral. On the other hand professional groups are assigned lower salary and social status with word pairs. Implications of results are discussed.
Resumo:
Life expectancy continuously increases but our society faces age-related conditions. Among musculoskeletal diseases, osteoporosis associated with risk of vertebral fracture and degenerative intervertebral disc (IVD) are painful pathologies responsible for tremendous healthcare costs. Hence, reliable diagnostic tools are necessary to plan a treatment or follow up its efficacy. Yet, radiographic and MRI techniques, respectively clinical standards for evaluation of bone strength and IVD degeneration, are unspecific and not objective. Increasingly used in biomedical engineering, CT-based finite element (FE) models constitute the state-of-art for vertebral strength prediction. However, as non-invasive biomechanical evaluation and personalised FE models of the IVD are not available, rigid boundary conditions (BCs) are applied on the FE models to avoid uncertainties of disc degeneration that might bias the predictions. Moreover, considering the impact of low back pain, the biomechanical status of the IVD is needed as a criterion for early disc degeneration. Thus, the first FE study focuses on two rigid BCs applied on the vertebral bodies during compression test of cadaver vertebral bodies, vertebral sections and PMMA embedding. The second FE study highlights the large influence of the intervertebral disc’s compliance on the vertebral strength, damage distribution and its initiation. The third study introduces a new protocol for normalisation of the IVD stiffness in compression, torsion and bending using MRI-based data to account for its morphology. In the last study, a new criterion (Otsu threshold) for disc degeneration based on quantitative MRI data (axial T2 map) is proposed. The results show that vertebral strength and damage distribution computed with rigid BCs are identical. Yet, large discrepancies in strength and damage localisation were observed when the vertebral bodies were loaded via IVDs. The normalisation protocol attenuated the effect of geometry on the IVD stiffnesses without complete suppression. Finally, the Otsu threshold computed in the posterior part of annulus fibrosus was related to the disc biomechanics and meet objectivity and simplicity required for a clinical application. In conclusion, the stiffness normalisation protocol necessary for consistent IVD comparisons and the relation found between degeneration, mechanical response of the IVD and Otsu threshold lead the way for non-invasive evaluation biomechanical status of the IVD. As the FE prediction of vertebral strength is largely influenced by the IVD conditions, this data could also improve the future FE models of osteoporotic vertebra.
Resumo:
In many languages, masculine generics are the traditional way of referring to women and men. However, gender-fair forms (e.g., feminine-masculine word pairs) can enhance gender equality: for instance, they counteract male biases in mental associations (Stahlberg et al., 2007) and evoke more neutral perceptions of gender-stereotypical professions (Merkel et al., 2013). Compared to masculine forms, use of gender-fair language in advertisements for leadership positions also helps to achieve gender equality in hiring decisions (e.g., use of German Geschäftsführerin/Geschäftsführer 'CEO fem/masc' instead of Geschäftsführer 'CEO masc', cf. Horvath & Sczesny, 2012). The present research investigates how potential applicants react to the use of gender-fair vs. masculine forms in German job ads for leadership positions (Study 1) and how the respective organization is perceived in response to these forms (Study 2). In Study 1, 251 participants showed higher intentions to apply for a leadership position when it was advertised with a feminine-masculine word pair instead of a masculine form; this was mediated by job appeal and organizational attraction. In Study 2, 154 participants perceived the organization as more discriminatory when masculine forms were used. This was mediated by the organizational image of gender equality. Thus, gender-fair language affects the social perception of a job and the respective organization and can impact social behavior in an organizational context.
Resumo:
OBJECTIVES To find a threshold body weight (BW) below 100 kg above which computed tomography pulmonary angiography (CTPA) using reduced radiation and a reduced contrast material (CM) dose provides significantly impaired quality and diagnostic confidence compared with standard-dose CTPA. METHODS In this prospectively randomised study of 501 patients with suspected pulmonary embolism and BW <100 kg, 246 were allocated into the low-dose group (80 kVp, 75 ml CM) and 255 into the normal-dose group (100 kVp, 100 ml CM). Contrast-to-noise ratio (CNR) in the pulmonary trunk was calculated. Two blinded chest radiologists independently evaluated subjective image quality and diagnostic confidence. Data were compared between the normal-dose and low-dose groups in five BW subgroups. RESULTS Vessel attenuation did not differ between the normal-dose and low-dose groups within each BW subgroup (P = 1.0). The CNR was higher with the normal-dose compared with the low-dose protocol (P < 0.006) in all BW subgroups except for the 90-99 kg subgroup (P = 0.812). Subjective image quality and diagnostic confidence did not differ between CT protocols in all subgroups (P between 0.960 and 1.0). CONCLUSIONS Subjective image quality and diagnostic confidence with 80 kVp CTPA is not different from normal-dose protocol in any BW group up to 100 kg. KEY POINTS • 80 kVp CTPA is safe in patients weighing <100 kg • Reduced radiation and iodine dose still provide high vessel attenuation • Image quality and diagnostic confidence with low-dose CTPA is good • Diagnostic confidence does not deteriorate in obese patients weighing <100 kg.